• Title/Summary/Keyword: bone cement

Search Result 234, Processing Time 0.024 seconds

Recurrence Analysis of Giant Cell Tumor after Curettage and Cementation (거대 세포종에서 골 소파술 및 시멘트 충전술 후의 재발 분석)

  • Hahn, Soo-Bong;Lee, Won-Jun;Shin, Kyoo-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.71-78
    • /
    • 2004
  • Purpose: The purpose of this study is to investigate the characteristic of recurred giant cell tumor after bony curettage and cementation, and to review a way to prevent the recurrence. Materials and Methods : Thirty seven cases were analyzed, which were pathologically diagnosed giant cell tumor after diagnostic biopsy or surgical excision, followed by curative curettage, burring and cementation. Location, character, and time interval to recurrence were reviewed. Results: Thirteen out of thirty seven analyzed cases(35%) showed recurrence after primary curettage and cementation. The mean interval to recurrence was sixteen months(5 months to 43 months). Most of recurrence happened within the first two years except two cases. Among the recurred cases, eleven showed recurrence in the vicinity of window area. Two cases recurred in the depth of bone marrow, where cementation was made. The advantage of curettage and cementation is the immediate stability of the operation site, early rehabilitation, and early detection of recurrence. Furthermore, cementation is beneficial in that the cement-producing heat can eradicate the residual tumor burden. In this study, 85% of cases with insufficient curettage (for example, in cases where too small surgical window was made, or where there were anatomical difficulty in approaching the target tumor burden) showed recurrence. Conclusion: Bony curettage, burring and cementation is widely used as the primary curative modality for giant cell tumor. A few other modalities such as chemical cautery using phenol and $H_2O_2$; cryotherapy; and anhydroalcohol have also been introduced, but the benefit of these are still questionable. For some cases that relatively small surgical window was made due to anatomically complicated structures (such as ligament insertion or origin site) over the target tumor burden, unsatisfactory curettage and burring was made. This study showed high chance of recurrence after unsatisfactory curettage, and 85% of recurrence developed in the vicinity of the small window area. Most of the recurrence occurred within the first two years. It is concluded that sufficient window opening, extensive curettage and eradicative burring are key factors to prevent recurrence. Also, it should be reminded that careful and close observation should be made for at least the first two years after initial treatment for early detection of recurrence.

  • PDF

Surgical Treatment of Osteoporotic Vertebral Compression Fractures at Thoraco-Lumbar Levels: Only Pedicle Screw Constructs with Polymethylmethacrylate Augmentation (흉요추부 골다공증성 척추 압박 골절의 수술적 치료: 골시멘트 보강술을 이용한 척추경 나사 고정)

  • Jun, Deuk Soo;Baik, Jong-Min;Park, Ji Hyeon
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.327-335
    • /
    • 2019
  • Purpose: To investigate the radiological efficacy of polymethylmethacrylate (PMMA) augmentation of pedicle screw operation in osteoporotic vertebral compression fractures (OVCF) patients. Materials and Methods: Twenty OVCF patients, who underwent only posterior fusion using pedicle screws with PMMA augmentation, were included in the study. The mean follow-up period was 15.6 months. The demographic data, bone mineral density (BMD), fusion segments, number of pedicle screws, and amount of PMMA were reviewed as medical records. To analyze the radiological outcomes, the radiologic parameters were measured as the time serial follow-up (preoperation, immediately postoperation, postoperation 6 weeks, 3, 6 months, and 1 year follow-up). Results: A total of 20 patients were examined (16 females [80.0%]; mean age, 69.1±8.9 years). The average BMD was -2.5±0.9 g/cm2. The average cement volume per vertebral body was 6.3 ml. The mean preoperative Cobb angle of focal kyphosis was 32.7°±7.0° and was improved significantly to 8.7°±6.9° postoperatively (p<0.001), with maintenance of the correction at the serial follow-up, postoperatively. The Cobb angle of instrumented kyphosis, wedge angle, and sagittal index showed similar patterns. In addition, the anterior part of fractured vertebral body height averaged 11.0±5.0 mm and was improved to 18.5±5.7 mm postoperatively (p=0.006), with maintenance of the improvement at the 3-month, 6-month, and 1-year follow-up. Conclusion: The reinforcement of pedicle screws using PMMA augmentation may be a feasible surgical technique for OVCF. Moreover, it appears to be appropriate for improving the focal thoracolumbar/lumbar kyphosis and is maintained well after surgery.

Clinical evaluation of the removable partial dentures with implant fixed prostheses (임플란트 고정성 보철물을 이용한 가철성 국소의치의 합병증에 관한 임상적 평가)

  • Kang, Soo-Hyun;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.239-245
    • /
    • 2016
  • Purpose: The purpose of this study was to identify clinical complications in removable partial denture (RPD) with implant-supported surveyed prostheses, and to analyze the factors associated with the complications such as location of the implant, splinting adjacent prostheses, the type of retentive clasps, Kennedy classification, and opposing dentition. Materials and Methods: A retrospective clinical study was carried out for 11 patients (7 male, 4 female), mean age of 67.5, who received RPD with Implant-supported surveyed prostheses between 2000 and 2016. The mechanical complications of 11 RPDs and 37 supporting implant prostheses and the state of natural teeth and peripheral soft tissue were examined. Then the factors associated with the complications were analyzed. Results: The average of 3.4 implant-supported prostheses were used for each RPD. Complications found during the follow-up period of an average of 42.1 months were in order of dislodgement of temporary cement-retained prostheses, opposing tooth fracture/mobility, screw fracture/loosening, clasp loosening, veneer porcelain fracture, marginal bone resorption and mobility of implant, artificial tooth fracture. Complications occurred more frequently in anterior region compared to posterior region, non-splinted prostheses compared to splinted prostheses, surveyed prostheses applied by wrought wire clasp compared to other clasps, and natural dentition compared to other removable prostheses as opposing dentition. There were no significant differences in complications according to the Kennedy classification. Conclusion: All implant-assisted RPD functioned successfully throughout the follow-up. However, further clinical studies are necessary because the clinical evidences are still not enough to guarantee the satisfactory prognosis of implant-assisted RPD for long-term result.

A Three-dimensional Photoelastic Analysis of Stress Distributions Around Osseointegrated Implants and Abutment Teeth According to Bridge Connecting Type (골유착성(骨癒着性) 임플란트와 치아간(齒牙間)의 보철물(補綴物) 연결(連結) 형태(形態)에 따른 주위(周圍) 골조직(骨組織)의 응력분산(應力分散)에 관한 3차원적(次元的) 광탄성(光彈成) 분석(分析))

  • Lee, Moo-Geon;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.120-147
    • /
    • 1994
  • This study was performed for the purpose of evaluating the stress distribution around threaded type implants, cylindrical type implants and teeth connected with rigid or non-rigid connector. The stress distribution around the surrounding bone was analyzed by three-dimensional photoelastic method. Twelve mandibular photoelastic epoxy resin models and a circular polariscope were used to record the isochromatic fringes. After the stress distribution around the implant and tooth was observed, the results were as follows ; 1. In threaded type implants, stress concentrated patterns were observed at the neck either vertical or 25 degree lateral force. 2. The stress concentrated patterns were observed at the tooth apical portion and neck portions of the implant and tooth when a threaded implant was connected with the tooth by either a rigid or non-rigid connector. More force was generated at the tooth neck portion by a rigid connector and more force at the implant neck portion by a non-rigid connector. 3. The stress concentrated patterns were observed at the apical portion of the implant and tooth when a cylindrical type ,implant was connected with the tooth either by a rigid or non-rigid connector. More force was generated at the tooth apical portion by a rigid connector and more force at the neck portion of the tooth and implant by a non-rigid connector. 4. The stress around the tooth was more equally distributed in a threaded type implant than in a cylindrical implant when the tooth was connected with either a rigid or non-rigid connector. 5. The stress around a threaded type implant was progressively more equally distributed in the following order : 1) when used a single implant, 2) a non-rigid connection with the implant and tooth, 3) a rigid connection with the implant and tooth, 4) a rigid connection with two implant fixtures.

  • PDF