• Title/Summary/Keyword: bond-strength, deformed bar

Search Result 35, Processing Time 0.019 seconds

A Study on the Basic Development Length of GFRP Rebar With Ribs (이형 GFRP 보강근의 기본정착길이에 대한 연구)

  • Moon, Do Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.5A
    • /
    • pp.485-493
    • /
    • 2010
  • GFRP rebar with ribs resemble those of deformed steel rebar was developed in 2005. It was reported that ribs of the GFRP rebar were sheared off due to the lower shear strength of polymer. In this study, the basic development length of the GFRP rebar was investigated through pull-out tests, models specified in ACI440.1R-03 and -06, and empirical model derived by Cosenza et al. (2002). As a results of pull-out tests, the critical embeddment length, which is defined as the length when failure mode is changed from pull-out to bar fracture, was 20 times of bar diameter for GFRP rebar and was 15 times for steel rebar. It is believed that the basic development of the GFRP rebar is 21 times of bar diameter, which is determined from the application of average bond strength into the model equation specified in ACI440.1R-03. Compared to the model equation in ACI440.1R-06, that in ACI440.1R-03 is recommendable for design purpose. The Cosenza et al.'s model underestimates the basic development length of the GFRP rebar.

The Bond Characteristics of Deformed Bars in High Flowing Self-Compacting Concrete (고유동 자기충전 콘크리트와 이형철근의 부착특성)

  • Choi, Yun Wang;Jung, Jea Gwone;Kim, Kyung Hwan;An, Tae Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.511-518
    • /
    • 2009
  • This study was intended to compare and evaluate the adhesion of High flowing Self-compacting Concrete (HSCC), Conventional Concrete (CC) and deformed bar based on concrete strength 3 (30, 50 and 70 MPa), among the factors affecting the bond strength between concrete and rebar, after fabricating the specimen by modifying the rebar position at Horizontal reinforcement at bottom position (HB), horizontal reinforcement at top position (HT) and vertical reinforcement type (V). As a result of measuring bond strength of HB/HT rebar to evaluate the factor of the rebar at top position, the bond strength of HB/HT rebar at 50 and 70 MPa was 1.3 or less and at 30 MPa, HSCC and CC appeared to be 1.2 and 2,1, respectively. Thus, when designing the anchorage length according to the concrete structure design standard (2007) at HSCC 30, 50 and 70 MPa, it would be desirable to reduce the correction factor of anchorage length of the horizontal reinforcement at top position, which is suggested for the reinforcement at top position, to less than 1.3 of CC.

An Analytical Study on the Anchorage Design in Exterior R/C Beam-Column Connections (R/C조 외측 보-기둥 접합부의 정착설계에 대한 해석적 연구)

  • 최기봉
    • Computational Structural Engineering
    • /
    • v.5 no.4
    • /
    • pp.133-142
    • /
    • 1992
  • An analytical model was developed for predicting the pullout behavior of straight beam longitudinal bars anchored at exterior beam-column connections. The model incorporates a local bond constitutive simulation capable of considering the effects of anchored bar diameter, yield strength and the spacing, concrete compressive strength, and column pressure on the bond characteristics of deformed bars in confined conditions of exterior joints. The analytical techniques adopted in this study were shown to satisfactorily predict the results of pullout tests on straight bars embedded in confined concrete specimens. An evaluation of the ACI-ASCE Committee 352 development length requirements in exterior joint conditions was made using the developed analytical approach. The results of this analytical evaluation are indicative of the conservatism of the current development length requirements in the confined conditions of exterior joints.

  • PDF

An Estimation of Wedge Type Removable Soil Nailing System Using by Laboratory Tests (실내역학 실험을 통한 쐐기형 제거식 쏘일네일링 공법의 적용성 평가)

  • Park, Si-Sam;Han, Yeon-Jin;Heo, Seong-Jun;Yoon, Myung-June;Kim, Hong-Taek;Park, Ju-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1330-1333
    • /
    • 2009
  • The soil nailing method had used in variable construction field because of construction convenience and reinforcement effect. Especially, the removal soil nailing method is useful support system in vertical excavation. In this study, to develop the wedge type removable soil nailing method for improvement of the removal soil nailing method. Because of the reinforcement materials is most important in soil nailing method, to evaluate the mechanical characteristics during laboratory strength test in this study. To conduct bond strength test of deformed bar combined with a wedged screw inside plastic fixed socket for evaluate the strength characteristics of wedge type removable soil nailing method and evaluate the strength characteristics of fixed socket based on laboratory tests.

  • PDF

The Estimation and Comparison of Flexural Crack Width Considering Bonding Characteristics in Reinforced Concrete Members (부착특성을 고려한 철근콘크리트 부재의 휨 균열폭 산정 및 비교)

  • Ko, Won-Jun;Min, Byung-Chul;Park, Sun-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.579-588
    • /
    • 2006
  • In recent years, the availability of high-strength reinforcing and prestressing steels leads us to build economically and efficiently designed concrete structural members. One of critical problems faced to the structural engineers dealing with these types of structural member is controls of crack width that is used as a criterion for the serviceability in the limit state design. Especially, flexural cracking must be controlled to secure the structural safety and to improve the durability as well as serviceability of the load carving members. The proposed method utilizes the results of pure tension test in which tensile loads are applied both side of specimen, done by Ikki. The bond characteristics of deformed reinforcing bar under pure tension is considered by the area of concrete and rib area. The results of proposed method are compared with the test data and the results show that the proposed method can take into account the dimensions, variation of sectional properties, and direction of reinforcing and gives more accurate maximum bond stress and corresponding relative slip than the existing methods. the characteristics of bonding is considered by using dimensionless slip magnitude and effective reinforcement ratio. The validity of the proposed equation is verified by test experimental data.