• 제목/요약/키워드: bond deterioration

검색결과 78건 처리시간 0.026초

순환골재의 강제 탄산화 개질 기술 개발을 위한 기초적 연구 (A Study on the Development of Forced Carbonation Reforming Technology for Recycled Aggregates)

  • 임명관;박원준;이혁;김도윤
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.207-208
    • /
    • 2016
  • The most important things for the production of recycled aggregates are saving energy, suppressing the generation of by-product fine particles and sustaining the performance of concrete. As solutions, this study proposes this technology of improving the performance of recycled aggregates through forced carbonation.1) It is to stimulate and carbonate the bond paste part that causes the deterioration of recycled aggregates. Particularly, the purpose of this technology is to fill and chemically stabilize pores inside the bond paste, further improving the quality of recycled aggregates with a decreased absorption rate and an enhanced aggregate strength. Ultimately, it is possible to obtain a carbonation model, depending on the paste ratio and particle-size distribution of recycled aggregates. Moreover, by calculating the optimum carbonation period through the verification of this carbonation model, it is possible to examine how much the strength is improved by the reformation of recycled aggregated.

  • PDF

탄소섬유로 휨보강된 RC 보의 부착 손실에 대한 거동 특성 (Structural Capacity of RC Beam Retrofitted by CFS with Bond Loss)

  • 서수연;윤현도;최기봉
    • 콘크리트학회논문집
    • /
    • 제19권6호
    • /
    • pp.795-802
    • /
    • 2007
  • 최근 탄소섬유를 보강재로 사용한 구조 부재의 휨 거동에 관한 많은 연구가 진행되어 왔으나, 대부분의 연구는 FRP를 이용한 설계법의 개발과 구조 성능 평가에 초점이 맞추어져 있기 때문에 장기적으로 보강재 또는 부착 상태의 변화에 따른 구조 성능 변화 등과 같은 현상을 반영하기에는 아직까지 부족한 점이 있다. 이에 따라 현재까지 보강된 FRP의 성능 저하에 따른 구조물의 구조 내력 저하에 대하여 구체적인 방안이 제시되기 위해서는 많은 사례 조사와 물성 변화를 고려한 구조물의 거동 특성 변화에 대한 지속적인 연구가 요망된다. 본 연구에서는 시간에 따라 저하되는 부착률의 변화에 따른 구조 성능의 변화를 관찰하고자, CFS의 부착률 변화와 부착 형태의 차이에 의한 거동 차이를 실험을 통해 밝히고, 기존 제안식을 이용하여 부착률과 부착 형태 차이에 따른 구조 성능 변화를 예측함으로써 CFS로 보강된 이후 부착률이 저하된 경우에 대한 거동 특성 평가방안을 제시하였다. 또한, 비선형 단면 해석을 통하여 실험 결과와 비교 검토하여 적정 해석 방법을 제시하였다.

하이브리드 콘크리트 보수재료의 휨부착 성능평가 (Evaluation of Flexural Bond Performance of Hybrid Concrete Repair Materials)

  • 김경태;김상준;박홍기;최영철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.176-181
    • /
    • 2018
  • 콘크리트 구조물은 시공 후 다양한 원인에 의해 물리적, 화학적 변형을 통해 물리적인 성능이 저하된다. 이러한 콘크리트 구조물의 성능저하는 사용수명을 감소하기 때문에 합리적인 보수보강이 필요하다. 최근 콘크리트 구조물의 효율적인 보수을 위해, 부착성능을 향상시킨 하이브리드 보수재료에 대한 연구가 활발히 수행되어오고 있다. 본 연구에서는 기존콘크리트와의 부착성능 및 수밀성을 향상시키기 위해 초속경 시멘트에 PVA 분말수지, 나일론 섬유, 라텍스를 혼입 한 하이브리드 보수재를 개발하였다. 보수재료의 성능평가를 위해 압축강도, 건조수축, 부착강도 실험을 수행하였다. 또한 미리 손상이 발생한 시험체를 제작한 후 보수 전후의 휨부착 성능평가를 수행하였다. 휨강도 평가결과, 기존의 초속경시멘트만 혼입한 시험체를 제외한 모든 실험체에서 110%~150%정도 휨강도가 크게 나타났고, 휨강도에 의해 발생된 균열패턴은 모든 실험체가 기존 콘크리트와 일체 거동하는 것으로 나타났다.

아스팔트 콘크리트 포장용 균열실링재의 부착특성 평가 (Evaluation of Adhesion Characteristics of Crack Sealants Used in Asphalt Concrete Pavement)

  • 이재준;김승훈;백종은;임재규;김용주
    • 한국도로학회논문집
    • /
    • 제17권2호
    • /
    • pp.55-62
    • /
    • 2015
  • Cracking is an inevitable fact of asphalt concrete pavements and plays a major role in pavement deterioration. Pavement cracking is one of the main factors determining the frequency and method of repair. Cracks can be treated with a number of preventative maintenance actions, including overlay surface treatments such as slurry sealing, crack sealing, or crack filling. Pavement cracks can show up as one or all of the following types: transverse, longitudinal, fatigue, block, reflective, edge, and slippage. Crack sealing is a frequently used pavement maintenance treatment because it significantly extends the pavement service life. However, crack sealant often fails prematurely due to a loss of adhesion. Because current test methods are mostly empirical and only provide a qualitative measure of the bond strength, they cannot accurately predict the adhesive failure of the sealant. This study introduces a laboratory test aimed at assessing the bonding of hot-poured crack sealant to the walls of pavement cracks. A pneumatic adhesion tensile testing instrument (PATTI) was adopted to measure the bonding strength of the hot-poured crack sealant as a function of the curing time and temperature. Based on a limited number of test results, the hot-poured crack sealants have very different bonding performances. Therefore, this test method can be proposed as part of a newly developed performance-based standard specification for hot-poured crack sealants for use in the future. PURPOSES : The purpose of this study was to evaluate both the adhesion and failure performance of a crack sealant as a function of its curing time and curing temperature. METHODS: A pneumatic adhesion tensile testing instrument (PATTI) was adopted to measure the adhesion performance of a crack sealant as a function of the curing time and curing temperature. RESULTS: With changes in the curing time, curing temperature, and sealant type, the bond strengths were found to be significantly different. Also, higher bond strengths were measured at lower temperatures. Different sealant types produced completely different bond strengths and failure behaviors. CONCLUSIONS: The bonding strength of an evaluated crack sealant was shown to differ depending on various factors. Two sealant types, which were composed of different raw materials, were shown to perform differently. The newly proposed test offers the possibility of evaluating and differentiating between different crack sealants. Based on alimited number of test results, this test method can be proposed as part of a newly developed performance-based standard specification for crack sealants or as part of a guideline for the selection of hot-poured crack sealant in the future.

GFRP 보강 내염성 콘크리트 보의 해양구조부재로서의 적용성 검토 (Study of Application of Salt Resistance Concrete Beam Reinforced with Glass Fiber Reinforced Polymer-Ribbed Bar as a Member of Marine Structure)

  • 김충호;황윤희
    • 한국해양공학회지
    • /
    • 제22권5호
    • /
    • pp.94-99
    • /
    • 2008
  • Three types of salt resistant concrete beams reinforced with glass fiber reinforced polymer-ribbed bars (GFRP-ribbed bars) were selected, and their applicable properties were investigated with the goal of improving the problem of capacity deterioration in marine structures due to sea water corrosion. In this study, the structural behaviors were similar to RC beams in relation to the development of the strength and stiffness up to the generation of the initial crack. After the growth of this initial crack, the structural properties decreased owing to a sudden loss of bond strength. Also these beams showed the trends of brittle failure. As a result, it was confirmed that a GFS beam replaced with Fly Ash (20%) and Silica Fume (5%) has the best application as a marine structural element.

횡방향 구속이 교각의 겹침이음에 미치는 영향에 대한 고찰 (Circumferential Confinement Effect on Lap-Spliced Reinforcements of Circular Bridge Pier)

  • 최영민;황윤국;권태규;박경훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.339-342
    • /
    • 2003
  • The bridge columns with lap-splice reinforcements in earthquake suffered a brittle bond-slip failure due to deterioration of the lap-spliced longitudinal reinforcements without developing its flexural capacity or ductility. In this case, such a brittle failure can be controlled by the seismic retrofit using FRP wrapping. The retrofitted columns using FRP wrapping showed significant improvement in seismic performance due to FRP's confinement effect. This paper presents the circumferential confinement effect of existing circular bridge pier strengthened with FRP wrapping for poor lap-splice details. The effects on the confinement of FRP wrapping, such as gap lengths between footing and FRP, fiber orientations, and thicknesses of FRP, were investigated by quasi-static experiments.

  • PDF

신ㆍ구 콘크리트의 접합면 조건에 다른 부착특성 (Bond characteristics by joint condition between old and. new concrete)

  • 주봉철;김영진;김병석;박성룡;김덕진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.859-864
    • /
    • 2003
  • In these days, the deterioration of bridges make it necessary for decks to be replaced and it is inevitable to apply the precast decks to minimize the traffic control induced from the deck placement. This precast deck construction makes the physically discontinuous interface between old and new concrete. Usually, the adhesive force at this interface are ignored. However, for crack behavior and reliable long term behavior, it is required to evaluate the exact value of the cohesive force at the interface. This research investigates the cohesive characteristics at the interface. Four different interface surface conditions are tested and three different methods are used to measure the cohesive strength at the interface. In addition, cohesive characteristic at the surface between precast panels are investigated with different interface surface conditions.

  • PDF

건축 복합방수공법의 최적성능에 관한 기초연구 (A Fundamental study on the Optimum Performance of the Architectural Hybrid Water-proofing Systems)

  • 임석호;임병훈
    • 한국건축시공학회지
    • /
    • 제5권2호
    • /
    • pp.123-130
    • /
    • 2005
  • The purpose of this study is to present the optimum performance of hybrid waterproofing technology, which is including material and construction method. Recently, Hybrid waterproofing technology is developed little by little in KOREA. But there is not any other criterion of performance and evaluation of this technology. So, It is needed that appropriate performance items is are settled urgently. This paper were obtained by the SPSS analysis. In this study the safety factor are more important performance of building waterproofing materials than durability comfortability and productivity. And results of this analysis showed that (1) safety performance consists of Fatigue resistance, Crack Control performance deterioration Processing of tensile performance, Compressive Strength test (2) comfortability performance consists of watertightness, bond performance (3) persistency performance consists of abrasion resistance, tensile performance, flexural strength (4) productivity performance consists of dimension, unit space weight.

Rebar corrosion effects on structural behavior of buildings

  • Yuksel, Isa
    • Structural Engineering and Mechanics
    • /
    • 제54권6호
    • /
    • pp.1111-1133
    • /
    • 2015
  • Rebar corrosion in concrete is one of the main causes of reduction of service life of reinforced concrete buildings. This paper presents the influence of rebar corrosion on the structural behavior of reinforced concrete (RC) buildings subjected to strong earthquake ground motion. Different levels of rebar corrosion scenarios were applied on a typical four story RC frame. The deteriorated conditions as a result of these scenarios include loss in cross-sectional area and loss of mechanical properties of the reinforcement bars, loss in bond strength, and loss in concrete strength and its modulus of elasticity. Dynamic analyses of the frame with different corrosion scenarios are performed with selected strong earthquake ground motion records. The influences of degradation in both concrete and reinforcement on structural behavior are investigated by comparing the various parameters of the frame under different corrosion scenarios with respect to each other. The results show that the progressive deterioration of the frame due to rebar corrosion causes serious structural behavior changes such as change in failure mode. The intensity, propagation time, and extensity of rebar corrosion have very important effects on the level of degradation of steel and concrete, as well as on the earthquake behavior of the structure.

지진발생시 FRP 보강이 횡방향 구속에 미치는 효과 (Circumferential Confinement Effect of Circular Bridge Pier with FRP Wrapping in Earthquake)

  • 최영민;황윤국;권태규;윤순종
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.280-287
    • /
    • 2003
  • The bridge columns with lap-splice reinforcements in earthquake suffered a brittle bond-slip failure due to the deterioration of lap-spliced longitudinal reinforcement without developing its flexural capacity or ductility. In this case, such a brittle failure can be controlled by the seismic retrofit using FRP wrapping. The retrofitted columns using FRP laminated circular tube showed significant improvement in seismic performance due to FRP's confinement effect. This paper presents the circumferential confinement effect of existing circular bridge pier strengthened with FRP wrapping for poor lap-splice details. The effects on the confinement of FRP wrapping, such as gap lengths between footing and FRP, fiber orientations, and thicknesses of FRP, were investigated by Quasi-static experiments.

  • PDF