• 제목/요약/키워드: bond adhesion

검색결과 248건 처리시간 0.023초

The effect of different adhesive system applications on push-out bond strengths of glass fiber posts

  • Kivanc, Bagdagul Helvacioglu;Arisu, Hacer Deniz;Uctasli, Mine Betul;Okay, Tufan Can
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.305-311
    • /
    • 2013
  • PURPOSE. Over the past years, the adhesion of fiber posts luted with simplified adhesive systems has been a matter of great interest. The aim of this study was to assess the post retentive potential of a self-adhesive resin cement using different adhesive systems to compare the push-out bond strengths of fiber posts. MATERIALS AND METHODS. The post spaces of 56 mandibular premolar roots were prepared and divided into 4 experimental groups and further divided into 2 subgroups according to testing time (n=7). The fiber posts (Rely X Fiber Post) were luted with a self-adhesive resin cement (RelyX Unicem) and one of the following adhesive systems: no adhesive, a total-etch adhesive resin (Single Bond), a two-step self-etch adhesive resin (Clearfil SE Bond) and a one-step self-etch adhesive resin (Clearfil S3 Bond). Each root was cut horizontally, and 1.5 mm thick six root segments were prepared. Push-out tests were performed after one week or three months (0.5 mm/min). Statistical analysis were performed with three-way ANOVA (${\alpha}$=.05). RESULTS. Cervical root segments showed higher bond strength values than middle segments. Adhesive application increased the bond strength. For one week group, the total-etch adhesive resin Single Bond showed higher bond strength than the self-adhesive resin cement RelyX Unicem applied without adhesive resin at middle region. For 3 months group, the two-step self-etch adhesive resin Clearfil SE Bond showed the highest bond strength for both regions. Regarding the time considered, Clearfil SE Bond 3 months group showed higher bond strength values than one week group. CONCLUSION. Using the adhesive resins in combination with the self-adhesive resin cement improves the bond strengths. The bond strength values of two-step self-etch adhesive resin Clearfil SE Bond improved as time passes.

Enhanced adhesion properties of conductive super-hydrophobic surfaces by using zirco-aluminate coupling agent

  • Park, Myung-Hyun;Ha, Ji-Hwan;Song, Hyeonjun;Bae, Joonwon;Park, Sung-Hoon
    • Journal of Industrial and Engineering Chemistry
    • /
    • 제68권
    • /
    • pp.387-392
    • /
    • 2018
  • Various technical approaches and concepts have been proposed to develop conductive super-hydrophobic (SH) surfaces. However, most of these approaches are not usable in practical applications because of insufficient adhesion and cost issues. Additionally, durability and uniformity issues are still in need of improvement. The goal of this research is to produce a large-area conductive SH surface with improved adhesion performance and uniformity. To this end, carbon nanotubes (CNT) with a high aspect ratio and elastomeric polymer were utilized as a conductive filler and matrix, respectively, to form a coating layer. Additionally, nanoscale silica particles were utilized for stable implementation of the conductive SH surface. To improve the adhesion properties between the SH coating layer and substrate, pretreatment of the substrate was conducted by utilizing both wet and dry etching processes to create specific organic functional groups on the substrate. Following pretreatment of the surface, a zirco-aluminate coupling agent was utilized to enhance adhesion properties between the substrate and the SH coating layer. Raman spectroscopy revealed that adhesion was greatly improved by the formation of a chemical bond between the substrate and the SH coating layer at an optimal coupling agent concentration. The developed conductive SH coating attained a high electromagnetic interference (EMI) shielding effectiveness, which is advantageous in self-cleaning EMI shielding applications.

핫멜트 점착제 및 아크릴 점착제에 대한 접촉속도(pretest speed)가 택에 미치는 영향 (The Effect of Pretest Speed on Probe Tack in SIS-based Hotmelt PSA and Water-borne Acrylic PSA)

  • 임동혁;김성은;김범준;도현성;김현중
    • 접착 및 계면
    • /
    • 제4권4호
    • /
    • pp.7-14
    • /
    • 2003
  • 택(tack)은 아주 가벼운 힘으로 단시간에 피착체와 점착하는 능력이다. 택의 측정기기 중 프로브택(probe tack)은 실험적인 영향인자를 설정할 수 있기에 택의 이론적 고찰이 유리하다. SIS계 핫멜트형 점착제(SIS-based hotmelt PSA)와 수분산성 아크릴 점착제(Water-borne acrylic PSA)를 사용하여 probe가 점착제 표면에 다가가는 속도가 택에 미치는 영향을 살펴보았다.

  • PDF

Low Temperature Cure Film Adhesive

  • Liang, Bin;Zhao, Shenglong
    • 접착 및 계면
    • /
    • 제5권2호
    • /
    • pp.1-7
    • /
    • 2004
  • A novel carboxyl terminated butadiene-acrylonitrile (CTBN) modified, low temperature cure epoxy film adhesive was developed in this paper. It can be cured at as low as $75^{\circ}C$ for 4 hours with a pressure of 0.1MPa. After post cure at $120^{\circ}C$ for 2 hours, the bonding strengths of Phosphoric Acid Anodizing(PAA) surface treated aluminum adherend were similar to those of structural film adhesives curing at $120^{\circ}C$. It is suitable to bond both metal/composite laminate-to-laminate and laminate to honeycomb structure.

  • PDF

Cu-Cr 합금박막의 필 접착력과 소성변형 (Peel Adhesion Strength and Plastic Deformation of Cu-Cr Alloy Thin Films)

  • 이태곤;임준홍;김영호
    • 한국표면공학회지
    • /
    • 제28권4호
    • /
    • pp.219-224
    • /
    • 1995
  • The peel adhesion and plastic deformation in Cu-Cr alloy films, sputter-deposited onto polyimide films, have been studied as a function of Cr content in the film. The adhesion strength has been measured by T-peel test and the amount of plastic deformation in the peeled metal strip was determined qualitatively by XRD technique. Peel adhesion strength has a maximum in the film containing 22-33wt.% Cr and the peel strength of pure Cr film is lower than the maximum. The film having the highest peel strength is deformed most heavily. The effect of Cr content on the peel strength is discussed in terms of the interfacial bond strength and mechanical properties of Cu-Cr alloy film.

  • PDF

Effect of Synthesis Method and Melamine Content of Melamine-Urea-Formaldehyde Resins on Bond-Line Features in Plywood

  • LUBIS, Muhammad Adly Rahandi;JEONG, Bora;PARK, Byung-Dae;LEE, Sang-Min;KANG, Eun-Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • 제47권5호
    • /
    • pp.579-586
    • /
    • 2019
  • This work examined effects of the synthesis method and melamine content of melamine-urea-formaldehyde (MUF) resins on the bond-line features (i.e. resin penetration and bond-line thickness) in plywood. Two synthesis methods (MUF-A and MUF-B) and three melamine contents (5, 10, and 20%) were employed to prepare MUF resins. The MUF-A resins at three melamine contents were prepared by a simultaneous reaction of melamine, urea, and formaldehyde, while the MFU-B resins were prepared by reacting melamine at the same levels with formaldehyde followed by urea. The results showed that higher melamine content increased the viscosity of MUF-A and MUF-B resins. The resin penetration of MUF-A resins decreased by 48% while those of MUF-B resins increased by 16% at 20% melamine content. As a result, the MUF-A resins had greater bond-line thickness than those of MUF-B resins as the melamine content increased. The MUF-B resins resulted in thinner bond-line and greater resin penetration compared to those of MUF-A resins. The results suggested that MUF-B resins prepared with 20% melamine content had a proper combination of resin penetration and bond-line thickness that could produce plywood panel with a better adhesion performance.

발포 폴리우레탄과 탄소강과의 접착 강도 측정 및 수증기 흡착의 영향 (Measurement of Adhesion Strength of Polyurethane Foam to Surface-Treated Carbon Steel and Effect of Water Vapor Absorption)

  • 김장순;조재동;임연수
    • 폴리머
    • /
    • 제27권4호
    • /
    • pp.340-348
    • /
    • 2003
  • 변형된 Stud-pull 시험 방법을 통해 탄소강 기재 위에 발포된 폴리우레탄의 접착 강도를 측정하였다. 아연인산으로 처리한 표면이 거친 탄소강 위에서 발포시킨 폴리우레탄의 접착 강도는 0.95 kN으로서 표면이 매끈한 양극산화된 탄소강 위에서 발포된 폴리우레탄의 접착 강도인 0.38 kN 보다 높게 나타남으로서 그 타당성이 입증되었다. 이 시험법을 여러 온도로 미리 가열된 탄소강 기재 위에서 폴리우레탄을 발포 접합시킨 시료들에 적용한 결과, 6$0^{\circ}C$ 이상으로 미리 가열된 금속 기재 위에서 발포된 폴리우레탄은 높은 접착 강도를 나타내었다. 또한 위의 시료를 수증기를 흡착하는 용기에 노출시켜 접착 강도를 측정하였는데 4$0^{\circ}C$ 보다 낮거나 7$0^{\circ}C$의 높은 온도로 유지된 금속 기재 위에서 발포된 폴리우레탄의 접착 강도는 많이 감소하였다. HCFC-141b와 HFC-245fa로 발포된 폴리우레탄의 접착력을 비교하였는데 HFC-245fa로 발포된 시료의 접착력이 0.03 kN 만큼 낮았으며 두 시료를 수증기에 노출시 HFC-245fa로 발포된 시료는 계면 근처에 존재하는 가스로 채워진 빈공간 영역의 적은 면적 비율로 인해 접착력이 거의 그대로 유지되었다. 이런 현상들은 기재의 온도, 기재의 표면 처리 방법, 발포제의 종류에 따라 금속 기재와 고분자와의 계면 근처에서의 미세조직학적인 차이에 의한 결과로 판단된다.

수종의 교정용 브라켓 접착 레진의 전단 강도 평가 (Evaluation of Shear Bond Strength of Various Orthodontic Bracket Bonding Agents)

  • 함영준;한미란
    • 대한소아치과학회지
    • /
    • 제49권3호
    • /
    • pp.264-273
    • /
    • 2022
  • 치과에서 사용하는 재료들의 물성의 발달로 인하여 브라켓과 치아 사이의 결합 능력도 크게 향상되었다. 그러나 소아치과 영역에서와 같이 환자의 협조를 기대하기 어렵거나, 수분 격리가 제대로 이루어지지 않을 경우 기대하는 효과에 미치지 못하는 결합강도를 보여 줄 수 있다. 본 연구의 목적은 세 가지의 접착 술식을 비교하여 브라켓의 전단 접착 강도를 평가하고, 임상적으로 유의한 차이가 존재하는지 비교하는 것이다. 우식증이나 수복물이 없는 상, 하악 소구치 60개 치아를 대상으로 하였다. Group I은 대조군으로서 기존의 3 step 접착 방식에 따라 브라켓을 부착하였고, Group II는 self-etching primer system을 이용하여 부착하였다. Group III는 self-priming adhesive를 이용하여 브라켓을 부착하였다. 각 group의 전단 결합 강도를 측정하고 접착제 잔류지수(ARI)를 기록하였다. 각 group I, II, III의 평균 전단 결합 강도는 14.69 MPa, 11.21 MPa 그리고 12.21 MPa로 측정되었다. Group I과 II, group I과 III에서만 유의한 차이가 존재하였으며(p < 0.05), ARI 값은 모든 group에서 유의한 차이가 존재하지 않았다.

수종의 영구 탄성 이장재와 의치상용 레진간의 인장 결합 강도 (COMPARISON ON TENSILE BOND STRENGTH OF PERMANENT SOFT DENTURE LINERS BONDED TO THE DENTURE BASE RESIN)

  • 김래규;정문규;임순호
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.200-211
    • /
    • 1999
  • For many years permanent soft denture liners has been widely used in dental practice directly or indirectly because of its function in absorbing and distributing the impact force. However, it reveals problems such as lack of permanency and decreased bond strength in long term use. The purpose of this study is to measure the bond strength and failure between denture base resin and several permanent liners. Lucitone 199 was used as denture base resin with soft acrylic liners (Triad, Tokuso Rebase) and silicone elastomers (Tokuyama, Ufi Gel C) bonded to measure the tensile strength before and after thermocycling. The thermocycling was done in 2000 cycles at $5^{\circ}C,\;26^{\circ}C\;and\;55^{\circ}C$ and the measured tensile strength values before and after thermocycling were compared. The mode of failure was investigated in the separated specimens. The results are as follows. 1. As to tensile strength, the strongest material is Tokuso Rebase followed by Triad, Tokuyama, Ufi Gel C in before thermocycling and the order of Triad, Tokuso Rebase, Tokuyama, Ufi Gel C in after thermocycling state. There was significant difference between the values of Triad, Tokuso Rebase and Tokuyama, Ufi Gel C(p<0.05). 2. As to degree of displacement, Ufi Gel C showed most displacement with or without thermo-cycling treatment and also the difference was significant with the other materials(p<0.05). 3. As to comparisons before and after thermocycling, Tokuso Rebase and Tokuyama showed significant difference in bond strength, whereas Triad and Tokuso Rebase showed significant difference in the degree of displacement(p<0.05). 4. In debonded specimens, Triad and Ufi Gel C showed adhesion failure and Tokuyama showed cohesion failure. Both failures were observed in Tokuso Rebase with adhesion failure up to 70%. The results of this study showed that degree of bond strength between permanent soft denture liner and denture base resin were variable. There was a significant difference between soft acrylics and silicone elastomers with regard to bond strength. Further research in improving bond strength of widely used silicone elastomers and in developing the method of measuring bond strength between denture base resin and the lining materials is needed.

  • PDF

Hot AC Anodising as a Cr(VI)-free Pre-treatment for Structural Bonding of Aluminium

  • Lapique, Fabrice;Bjorgum, Astrid;Johnsen, Bernt;Walmsley, John
    • 접착 및 계면
    • /
    • 제4권2호
    • /
    • pp.21-29
    • /
    • 2003
  • Hot AC anodising has been evaluated us pre-treatment for aluminium prior to structural adhesive bonding. Phosphoric and sulphuric acid hot AC anodising showed very promising adhesion promoter capabilities with durability comparable with the best standard DC anodising procedures. AC anodising does not required etching prior to anodising and offers u pre-treatment time down to 20 seconds. The interface/interphase between the aluminium substrate and the adhesive was investigated in order to get a better understanding of the involved adhesion mechanisms and to explain the long-tenn properties. The alkaline medium formed at the oxide layer/adhesive interface has been shown to induce a partial dissolution of the oxide layer leading to the formation of metallic ions which diffuse in the adhesive (EPMA measurements). The effect of diffusion of the Al ions on adhesion and joint durability is still uncertain but studies showed that pre-bond moisture affected the joints durability and to some extent the diffusion length. specially for DC anodised samples. So far no direct correlation could be established between the diffusion length d and the joints durability but new trials with better control over the elapsed time between bonding and adhesive curing are expected to help getting a better understanding of the involved mechanisms.

  • PDF