• Title/Summary/Keyword: bolus

Search Result 439, Processing Time 0.028 seconds

A Study on $Na^+$ and Water Reabsorption in the Nephron Segment Beyond Proximal Tubule Measured by Lithium Clearance

  • Han, O-Soo;Goo, Yong-Sook;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.25 no.2
    • /
    • pp.189-200
    • /
    • 1991
  • During the past few years it has been proposed that lithium clearance can be used as a reliable measure for the outflow of tubular fluid from the proximal tubule. This study was aimed to characterize the inflow dependent reabsorption of Na in renal tubule beyond the proximal tubule. For this purpose, lithium clearance was used as a measure for the inflow from the proximal tubule and the changes in reabsorption fraction of Na and water were determined in rabbits. Rabbits were pretreated with hypotonic saline solutions for an hour (50 mM/L NaCl, 20 ml/hr/kg). And then a hypertonic solution of 500 mM/L NaCl (20 ml/kg) was administered intraperitoneally in conjunction with a bolus of LiCl solution (2 mM/kg, i.v.) for conditioning the $C_{Li}$ and urine flow rate. To rule out the effect of $Li^+$ on tubular functions, a bolus of NaCl solution (2 mM/kg, i.v.) was administered. Fifteen, thirty, and sixty minutes after injection of hypertonic saline arterial blood and urine samples were taken. Urinary and plasma concentrations as well as urinary output of $Li^+,\;Na^+\;and\;K^+$ were measured. From these $C_{Li},\;C_{Na}$ and the reabsorption fraction of Na and water $(Fr_{Na}\;&\;FrH_2O)$ were calculated. These results were compared with those from control groups in which the same amount of isotonic saline (145 mM/L NaCl) and of 15% dextran solution were administered in the same way as that in experimental group. Followings are the results obtained. 1) The plasma concentration of $Na^+$ in rabbits injected with hypertonic saline reached the peak value after 15 min and thereafter no significant change was observed. Hematocrit values did not show any change, while urinary excretion of $Na^+$ increased markedly during the first 15 min and decreased thereafter. These results were not affected by an injection of a small amount of LiCl. 2) The clearances of $Li^+,\;Na^+\;and\;K^+$ in rabbits injected with hypertonic saline and LiCl solution decreased. 3) In spite of the variation in $C_{Li},\;Fr_{Na}$ did not show any significant change while $FrH_2O$ increased gradually. 4) $C_{Li}$ decreased also in rabbits received isotonic saline. $Fr_{Na}$ tended to be higher than that in hypertonic saline group, while $FrH_2O\;and\;Fr_{Na}$ did not associated with the decrease in $C_{Li}$. 5) $C_{Li}$ of the rabbits received dextran solution fluctuated persistently and $Fr_{Na}\;and\;FrH_2O$ did not change in along with $C_{Li}$ although $Fr_{Na}$ had a tendency to be higher than that in hypertonic saline group. 6) From the above results it was concluded that: (a) In rabbits with normal body store of $Na^+$, the $Fr_{Na}$ of renal tubule beyond proximal tubule. calculated from $C_{Li}$ as a measure of inflow from proximal tubule is constant in spite of variations in $C_{Li}$. (b) The $FrH_2O$ calculated from $C_{Li}$ is dependent largely upon ADH rather than inflow from proximal tubule. (c) When there is a decrease in plasma $Na^+$ concentration or ineffective body fluid. $Li^+$ reabsorption may occur in the thick segnent of Henle's loop and hence the determination of $Fr_{Na}$ and $FrH_2O$ will not be easy one, but $Fr_{Na}$ is constant under the same experimental conditions.

  • PDF

Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit (안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가)

  • Kwak, Yong Kuk;Hong, Sun Gi;Ha, Min Yong;Park, Jang Pil;Yoo, Sook Hyun;Cho, Woong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.87-95
    • /
    • 2015
  • Purpose : This study presents the usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit. Materials and Methods : We accomplished IMRT treatment plan similar with a real one through the computed treatment planning system after CT simulation using human phantom. For the secondary shield, we used Pb plate (thickness 3mm, diameter 25mm) and 3 mm tungsten eye-shield block. And we compared lens dose using OSLD between on TPS and on simulation. Also, we irradiated 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$) on a 5cm acrylic phantom using the secondary shielding material of same condition, 3mm Pb and tungsten eye-shield block. And we carried out the same experiment using 8cm Pb block to limit effect of leakage & transmitted radiation out of irradiation field. We attached OSLD with a 1cm away from the field at the side of phantom and applied a 3mm bolus equivalent to the thickness of eyelid. Results : Using human phantom, the Lens dose on IMRT treatment plan is 315.9cGy and the real measurement value is 216.7cGy. And after secondary shield using 3mm Pb plate and tungsten eye-shield block, each lens dose is 234.3, 224.1 cGy. The result of a experiment using acrylic phantom, each value is 5.24, 5.42 and 5.39 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Applying O.S.B out of the field, each value is 1.79, 2.00 and 2.02 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Conclusion : When secondary shielding material is used to protect critical organ while irradiating photon, high atomic number material (like metal) that is near by critical organ can be cause of dose increase according to treatment region and beam direction because head leakage and collimator & MLC transmitted radiation are exist even if it's out of the field. The attempt of secondary shield for the decrease of exposure dose was meaningful, but untested attempt can have a reverse effect. So, a preliminary inspection through Q.A must be necessary.

  • PDF

The Variation of Surface Dose by Beam Spoiler in 10 MV Photon Beam from Linear Accelerator (선형가속기 10 MV 광자선에서 산란판(Beam Spoiler) 사용 시 표면선량 변화)

  • Bae, Seong-Cheol;Kim, Jun-Ho;Lee, Choul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • Purpose: The purpose of this study is to find a optimal beam spoiler condition on the dose distribution near the surface, when treating a squamous cell carcinoma of the head and neck and a lymphatic region with 10 MV photon beam. The use of a optimal spoiler allows elivering high dose to a superficial tumor volume, while maintaining the skin-sparing effect in the area between the surface to the depth of 0.4 cm. Materials and Methods: The lucite beam spoiler, which were a tissue equivalent, were made and placed between the surface and the photon collimators of linear accelerator. The surface-dose, the dose at the depth of 0.4 cm, and the maximum dose at the dmax were measured with a parallel-plate ionization chamber for $5{\times}5cm\;to\;30{\times}30cm^2$ field sizes using lucite spoilers with different thicknesses at varying skin-to-spoiler separation (SSS). In the same condition, the dose was measured with bolus and compared with beam spoiler. Results: The spoiler increased the surface and build-up dose and shifted the depth of maximum dose toward the surface. With a 10 MV x-ray beam and a optimal beam spoiler when treating a patient, a similer build-up dose with a 6 MV photon beam could be achieved, while maintaining a certain amount of skin spring. But it was provided higher surface dose under SSS of less than 5 cm, the spoiler thickness of more than 1.8 cm or more, and larger field size than $20{\times}20cm^2$ provided higher surface dose like bolus and obliterated the spin-sparing effect. the effects of the beam spoiler on beam profile was reduced with increasing depths. Conclusion: The lucite spoiler allowed using of a 10 MV photon beam for the radiation treatment of head and neck caner by yielding secondary scattered electron on the surface. The dose at superficial depth was increased and the depth of maximum dose was moved to near the skin surface. Spoiling the 10 MV x-ray beam resulted in treatment plans that maintained dose homogeneity without the consequence of increased skin reaction or treat volume underdose for regions near the skin surface. In this, the optimal spoiler thickeness of 1.2 cm and 1.8 cm were found at SSS of 7 cm for $10{\times}10cm^2$ field. The surface doses were measured 60% and 64% respectively. In addition, It showed so optimal that 94% and 94% at the depth of 0.4 cm and dmax respectively.

  • PDF

The Influence of 5-Fluorouracil Administration Mode on the Expression of Phospholipase C and Ras Oncoprotein Associated with Regeneration of Rat Intestinal Mucosa Following Radiation (방사선 조사후 백서 공장 점막의 재생과정에서 5-fluorouracil 투여가 phospholipsse C 와 ras 암유전자단백의 발현에 미치는 영향)

  • Park Kyung Ran;Lee Chung Sik;Kim Sung Sook;Lee Young Han;Ryu Sung Ho;Suh Pann-Ghill
    • Radiation Oncology Journal
    • /
    • v.12 no.3
    • /
    • pp.271-284
    • /
    • 1994
  • Purpose : Phospholipase C(PLC) isozymes play significant roles in transmembrane signal transduction. PLC-${\gamma}1$ acts as the intracellular effector in signal transduction for cellular proliferation and differentiation. Ras oncoprotein is also involved in cell growth. We determined the biological significance of PLC and ras oncoprotein in regeneration following radiation and the effect of different modes of administration of 5-FU. Materials and Methods : To determine the effect of the administration mode of 5-FU on the regeneration of intestinal mucosa of rats following radiation, we compared the expression of PLC and ras oncoprotein in six groups. Group I had no treatment. Group II received radiation(8 Gy) only. Group III received radiation(8 Gy) and 5-FU(150mg/kg) continuous intravenous (iv) infusion for 12 hours. Group IV received radiation(8 Gy) and 5-FU(750mg/kg) iv bolus injection. Group V received only 5-FU(150mg/kg) continuous iv infusion for 12 hours, Group VI received only 5-FU (150mg/kg) iv bolus injection. Through immunoblotting and immunohistochemistry, we examined the expression of PLC and ras oncoprotein in rat jejunum at 96 hours after radiation or 5-FU administration and at 120 hours after radiation and 5-FU adminstration. We also investigated the histological findings using hematoxylin and eosin stain. Results : In the immunohistochemistry study, PLC-${\gamma}1$ expression was the highest in group III followed by groups II and VI in that order and was weakly positive in groups V and VI. PLC-${\gamma}1$ was hardly detected in the control group. The expression of ras oncoprotein was the same as the PLC-${\gamma}1$ expression for all groups. These results were confirmed by the histological findings regarding the mucosal regeneration. In the immunoblotting analysis, PLC-${\gamma}1$ expression was the highest in group III followed by group IV and II in that order. This difference between the immunoblotting and immunohistochemistry study was due to the high expression of PLC-${\gamma}1$ on the damaged surface epithelium rather than to its expression in the regeneration region as observed in the immunohistochemistry study for group IV. The expression of PLC-${\delta}1$ was positive only in group V and VI, which received both radiation and 5-FU, and the expression of PLC-${\beta}1$ was negligible for all groups. Conclusion : These results suggest that PLC-${\gamma}1$ mediated signal transduetion and ras oncoprotein may have a significant role in mucosal regeneration after radiation, and that continuous iv infusion of 5-FU may induce active regeneration in intestinal mucosa following radiation. In addition, the expression of PLC-${\delta}1$ in combined group of radiation and 5-FU implies that PLC-${\delta}1$ may be involved in signal transduction mediated by concerted action between radiation and 5-FU.

  • PDF

Evaluation after Applicated a Mold to a Paraneoplastic Autoimmune Multiorgan Syndrome Patient with Hypervascular Ulcer in the Oral Cavity during Treatment with Mold Brachytherapy (Paraneoplastic Autoimmune Multiorgan Syndrome으로 인하여 구강 내 국소적으로 발생한 과다혈관성 궤양의 방사선 근접치료 시 자체 제작한 Mold의 유용성 평가)

  • Park, Ju-Kyeong;Lee, Sun-Young;Lim, Seok-Geon;Kwak, Geun-Tak;Lee, Seung-Hun;Kim, Yang-Su;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • Purpose: Evaluate the mold we have made to improve the reproducibility of the patient position and make homogeneous dose distribution to the treatment volume effectively when treating the patient who has hypervascular ulcer on her tongue caused by paraneoplastic autoimmune multiorgan syndrome by mold brachytherapy. Materials and Methods: The mold is consisted of upper and lower parts. We inserted 2 mm of lead sheet on the gums toward the oral cavity to protect them from unnecessary irradiation during the treatment. We had planned on orthogonal images obtained the patient. 200 cGy was delivered in every fraction with a total dose of 3000 cGy. To evaluate the effect of the lead sheet, we made a measurement with a phantom that has gums and tongue made of tissue with an equivalent material (bolus). Five of TLDs were placed on the interesting points of gums to measure the dose during irradiation with lead sheet and without lead sheet for three times respectively. Results: The result of the measurement without lead sheet are A: 33.9 cGy, B: 30.1 cGy, C: 31.8 cGy, D: 23.3 cGy, E: 24.1 cGy. The results of measurement with lead sheet are A: 20.6 cGy, B: 18.8 cGy, C: 19.6 cGy, D: 14.7 cGy, E: 15.1 cGy. Conclusion: Since we are using the mold made in our department during the treatment of the patient with hypervascular ulcer on tongue, we could deliver a proper dose to the treatment volume. In addition, the mold provided highly accurate and reproducible treatment and reduced the dose to the gums and teeth. Therefore, the possibility of side effects could be decreased significantly.

  • PDF

The Effect of Doxapram on Cardiopulmonary Function in Dogs under Total Intravenous Anesthesia with Remifentanil and Propofol (개에서 Remifentanil과 Propofol에 의한 완전 정맥 내 마취 시 Doxapram 투여가 심폐기능에 미치는 효과)

  • Yun, Sungho;Kwon, Youngsam
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.491-498
    • /
    • 2015
  • We investigated the effect of constant rate infusion (CRI) with doxapram on cardiopulmonary function during total intravenous anesthesia (TIVA) with remifentanil and propofol CRI in dogs. Fifteen male Beagle dogs were randomly divided into 3 groups. All groups were premedicated with medetomidine ($20{\mu}g/kg$, IV) and anesthetized by remifentanil/propofol CRI for one and half hour. At the initiating of the anesthesia, different doses of doxapram for each group were administrated as the followings; D1 group - doxapram 0.25 mg/kg bolus followed by doxapram $8.33{\mu}g/kg/min$, D2 group - doxapram 2 mg/kg bolus followed by doxapram $66.66{\mu}g/kg/min$, control group - normal saline. The anesthetic depth for surgery was well maintained in all groups throughout the anesthetic periods. The respiratory rate was significantly higher in D2 group than that of control group (p < 0.05). The values of $PaO_2$ and $SaO_2$ were significantly increased in both D1 and D2 groups compared with control group (p < 0.05). High dose of doxapram (D2 group) significantly decreased the level of $PaCO_2$ compared with control group (p < 0.05). The values of systolic, mean and diastolic arterial pressure were significantly increased in doxapram 2 group (p < 0.05). There were no significant differences in the values of heart rate and pH of arterial blood. Therefore, doxapram CRI may be useful to alleviate the suppression of cardiopulmonary function including hypoxia and hypotension during TIVA with remifentanil and propofol in dogs.

Concurrent Chemoradiation in Patients with Cancer of the Esophagus (식도암에서의 동시화학방사선요법)

  • Lee Kang Kyoo;Park Kyung Ran;Lee Jong Young;Shin Hyun Soo;Lee Chong In;Chang Woo Ick;Shim Young Hak
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.7-16
    • /
    • 1998
  • Purpose : To evaluate survival rate and prognostic factors affecting survival of patients with esophageal cancer treated with concurrent chemoradiation. Materials and Methods : Eligibility included biopsy proven invasive carcinoma of the cervical or thoracic esophagus, confined to esophagus and mediastinum with or without regional lymph node and supraclavicular lymph node, and ECOG Performance status $H_0-H_2$. Patients received radiation therapy with 5940cGy over 7 weeks and chemotherapy, consisted of 5-FU(1000 $mg/m^2/day$ in continuous infusion for 5 days, days 1 to 5 and days 29 to 33) and mitomycin C($8mg/m^2$ intravenous bolus at day 1). After concurrent chemoradiation, maintenance chemotherapy was followed with 5-FU(1000 $mg/m^2/day$ in continuous infusion for 5 days at 9th, 13th, and 17th weeks) and cisplatin($80mg/m^2$ intravenous bolus at the first day of each cycle). Results : From November 1989 to November 1995, 44 patients were entered in this study. After treatment, complete response rate and partial response rate were $59\%$ and $41\%$. Overall 1, 2, and 5-year survivals were $59\%$, $38\%$, and $9.6\%$(median 17 months), Prognostic factors affecting survival were response to treatment and T-stage. Among 26 complete responders, there were 6 local recurrences, 3 distant recurrences, 1 local and distant recurrence, and 2 unknown site recurrences Acute and chronic complication rates with grade 3 or more were $20\%$ and $13.0\%$ and there was no treatment-related mortality. Conclusion : Concurrent chemoradiation, compared with historical control groups that treated with radiation alone, improved median survival and did not significantly increase treatment-related complications. Complete responders had longer survival duration than partial responders. Predominant failure pattern was local failure. So, efforts to improve local control should be proposed.

  • PDF

A Study on Superficial Dose of 6MV-FFF in HalcyonTM LINAC: Phantom Study (HalcyonTM 선형가속기 6MV-FFF 에너지의 표재 선량에 대한 고찰: Phantom Study)

  • Choi, Seong Hoon;Um, Ki Cheon;Yoo, Soon Mi;Park, Je Wan;Song, Heung Kwon;Yoon, In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.31-39
    • /
    • 2020
  • Purpose: The aims of this study were to compare the superficial dose with Optically Stimulated Luminescence Dosimeter(OSLD) measurement and Treatment Planning System(TPS) calculation for 6MV-Flattening Filter Free(FFF) energy using HalcyonTM and TrueBeamTM. Materials and methods: Phantom study was performed using the CT images of human phantom. In the treatment planning system, the Planning Target Volume(PTV) was contoured which is similar to Glottic cancer. Furthermore, Point(M), Point(R), and Point(L) were contoured at the iso-center of head and neck region and 5mm bolus was applied to the body contour. Each treatment plans using 6MV-FFF energy from HalcyonTM and TrueBeamTM with static Intensity Modulated Radiation Therapy(IMRT) and Volumetric Modulated Arc Therapy(VMAT) were established with eclipse. To reproduce the same position as the TPS, OSLDs were placed at the iso-center point and 5mm bolus was applied to compare the error rate after the dose delivery. Result: The results of the study using human phantom are as follows. In case of HalcyonTM, the mean absolute error rates of the point dose using the treatment planning system and the dose measured by OSLD were 1.7%±1.2% for VMAT and 4.0±2.8% for IMRT. Also TrueBeamTM was identified as 2.4±0.4% and 8.6±1.8% respectively for VMAT and IMRT. Conclusion: Through the results of this study, TrueBeamTM confirmed that the average error rate was 2.4 times higher for VMAT and 3.6 times higher for IMRT than HalcyonTM. Therefore, based on the results of this study, If we need a more accurate dose assessment for the superficial dose, It is expected that using HalcyonTM would be better than TrueBeamTM.

Preoperative Concurrent Radio-chemotherapy for Rectal Cancer: Report of Early Results (직장암에 대한 수술 전 동시병용 방사선-항암 화학요법: 초기 치료결과 보고)

  • Shin, Seong-Soo;Ahn, Yong-Chan;Chun, Ho-Kyung;Lee, Woo-Yong;Kang, Won-Ki;Park, Young-Suk;Park, Joon-Oh;Song, Sang-Yong;Lim-Do-Hoon;Park, Won;Lee, Jung, Eun;Kang, Min-Kyu;Park, Yung-Je
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.125-134
    • /
    • 2003
  • Purpose: To report the early results of preopeartive concurrent radio-chemotherapy (CRCT) for treating rectal cancer. Materials and Methods: From June 1999 to April 2002, 40 rectal cancer patients who either had lesions with a questionable resectability or were candidates for sphincter-sacrificing surgery received preoperative CRCT. Thirty-seven patients completed the planned CRCT course. 45 Gy by 1.8 Gy daily fraction over 5 weeks was delivered to the whole pelvis in the prone position. The chemotherapy regimens were oral UFT plus oral leucovorin (LV) in 12 patients, intravenous bolus 5-FU plus LV in 10 patients, and intravenous 5-FU alone in 15 patients (bolus infusion in 10, continuous infusion in 5). Surgery was planned in 4$\~$6 weeks of the completion of the preoperative CRCT course, and surgery was attempted in 35 patients. Results: The compliance to the current preoperative CRCT protocol was excellent, where 92.5$\%$ (37/40) completed the planned treatment. Among 35 patients, in whom surgery was attempted after excluding two patients with new metastatic lesions in the liver and the lung, sphincter-preservation was achieved in 22 patients (62.9$\%$), while resection was abandoned during laparotomy in two patients (5.7$\%$). Gross complete resection was peformed in 30 patients, gross incomplete resection was peformed in one patient, and no detailed information on the extent of surgery was available in two patients. Based on the surgical and pathological findings, the down-staging rate was 45.5$\%$ (15/33), and the complete resection rate with the negative resection margin 78.8$\%$ (26/33). During the CRCT course, grade 3 $\~$4 neutropenia developed in four patients (10.8$\%$). Local recurrence after surgical resection developed in 12.1$\%$ (4/33), and distant metastases after the preoperative CRCT start developed in 21.6$\%$ (8/37). The overall 3-years survival rate was 87$\%$. Conclusion: Preoperative CRCT in locally advanced rectal cancer is well tolerated and can lead to high resection rate, down-staging rate, sphincter preservation rate, however, longer term follow-up will be necessary to confirm these results.

The Clinical Usefulness Evaluation of Normal Saline Injection in Coronary Artery Computed Tomography Angiography(Coronary CTA) (관상동맥 전산화단층촬영 조영검사에서 생리식염수 투여를 통한 임상 유용성 평가)

  • Jung, Kang-Kyo;Lee, Mi-Hwa;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.307-313
    • /
    • 2014
  • The purpose of this study is that in coronary artery angiography computed tomography (coronary CTA), to gain high quality of image and to use low dose radiation by administrating normal saline and converting the mode of scanning heart rate (HR) characteristics before infusing contrast media. All patients data (total specimens: 200, male: 108, female: 92) were measured by using appropriate mode of scanning the heart rate (HR) after injection of saline. in addition we measured radiation dose (CTDIvol, effective dose) in all examinations. CT number and noise, and blurring of coronary artery (proximal RCA, middle RCA, proximal LCA) were measured and compared. The result of this study after injection of saline, mean heart rate was decreased about $4.8{\pm}0.3bpm$ (beats per minute). 33 patients (13%) got converting scan mode due to reducing heart rate (HR). In prospective gating mode, radiation dose were measured less $6.0{\pm}1.0mSv$ (54.1%) than retrospective gating mode. Also showed a significant difference in heart rate decrease in image evaluation.