• Title/Summary/Keyword: body temperature measuring

Search Result 145, Processing Time 0.032 seconds

Effects of grain-based pecking blocks on productivity and welfare indicators in commercial broiler chickens

  • Byung-Yeon Kwon;Hyun-Gwan Lee;Yong-Sung Jeon;Ju-Yong Song;Jina Park;Sang-Ho Kim;Dong-Wook Kim;Kyung-Woo Lee
    • Animal Bioscience
    • /
    • v.37 no.3
    • /
    • pp.536-546
    • /
    • 2024
  • Objective: This experiment was conducted to investigate the effect of grain-based pecking blocks on productivity and welfare status at two commercial broiler welfare-certified farms. Methods: Production and welfare indicators were assessed at two farms (designated Farm A and B). Both farms had two windowless houses with forced tunnel-type ventilation and housed broilers at stocking densities of approximately 16.7 birds/m2 (Farm A) and 16.8 birds/m2 (Farm B). Each house was divided into two or three equal sections and was provided with or without pecking blocks. Grain-based pecking blocks, measuring 25 × 25 × 25 cm, were given to broilers in both farms at 1 block per 1,000 birds. Various parameters including productivity (body weight and flock uniformity), corticosterone levels (in fecal droppings and feathers), footpad dermatitis, hock burn, feather dirtiness, gait score, litter quality, body surface temperature, and volatile fatty acids in fecal samples were assessed at 26 days of age, whereas litter quality was analyzed at 13 and 26 days of age. Results: There were no significant effects of providing pecking blocks on productivity (body weight and uniformity), fecal and feather corticosterone, welfare indicators (i.e., footpad dermatitis, hock burn, feather cleanliness, and gait score), and litter quality (i.e., moisture, nitrogen, and pH). No differences in body surface temperature between the control and enrichment treatments were noted in Farm B, but body surface temperatures of the head (p = 0.029) and legs (p = 0.011) in the enrichment vs. control group were elevated in Farm A. Butyrate concentration in the enrichment vs control group was higher in Farm B (p = 0.023), but this effect was not detected in Farm A. Conclusion: It is concluded that grain-based pecking blocks did not affect performance and welfare indicators. Further studies are warranted to elucidate the potential impact of grain-based pecking blocks on gut health indicators.

A comparison study of measured values and subjective experience of mercury thermometer and tympanic thermometer (수은체온계와 고막체온계의 측정치와 측정시 경험에 관한 비교연구)

  • Min Soon
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.4 no.1
    • /
    • pp.95-106
    • /
    • 1998
  • This study aims to provide a better nursing service in the dimension of economizing time and human efforts. This is to present some basic knowledge necessary to improving a nursing quality in measuring body temperature by analyzing the contents that the objects experienced at the time of measure with tympanic thermometer and mercury thermometer Subjects of the survey consisted of 71 college students, 47 adult patients and 40 pediatric patients. The results were as follows : 1. The oral temperature by mercury thermometer and tympanic thermometer with oral mode was : $36.83^{\circ}C$ by mercury thermometer and $37.02^{\circ}C$ by tympanic thermometer in college students : it showed an significant difference statistically. 2. Comparsion between oral mode and rectal mode by tympanic thermometer in college students : $37.03^{\circ}C$ by oral mode and $37.55^{\circ}C$ by rectal mode and this defference was significant statistically 3. Comparision between rectal temperature by mercury thermometer and rectal mode of tympanic thermometer : $37.54^{\circ}C$ by mercury thermometer and $37.73^{\circ}C$ by tympanic thermometer, it showed a significant difference statistically. 4. Comparision between oral temperature by mercury thermometer and oral mode of tympanic thermometer of the pediatric patients : $36.51^{\circ}C$ by mercury temperature and $36.94^{\circ}C$ by tympanic thermometer, it showed a significant difference statistically. 5. Comparision between oral body temperature by mercury thermometer and oral mode of tympanic thermometer of the adult patients : $36.56^{\circ}C$ by mercury thermometer and $36.90^{\circ}C$ by tympanic thermometer, it did not show statistically any difference. 6. At the measure by mercury thermometer this data can classified In three main categorise : their feeling to a thermometer, thermometer itself and aspect physical of the clients. It is considered that an subjective experience to tympanic thermometer was more positive.

  • PDF

A Work-related Musculoskeletal Disorder Risk Assessment Platform using Smart Sensor (스마트센서를 활용한 근골격계 질환 위험 평가 플랫폼)

  • Loh, Byoung Gook
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.93-99
    • /
    • 2015
  • Economic burden of work-related musculoskeletal disorder(WMDs) is increasing. Known causes of WMDs include improper posture, repetition, load, and temperature of workplace. Among them, improper postures play an important role. A smart sensor called SensorTag is employed to estimate the trunk postures including flexion-extension, lateral bend, and the trunk rotational speeds. Measuring gravitational acceleration vector in the smart sensor along the tri-orthogonal axes offers an orientation of the object with the smart sensor attached to. The smart sensor is light in weight and has small form factor, making it an ideal wearable sensor for body posture measurement. Measured data from the smart senor is wirelessly transferred for analysis to a smartphone which has enough computing power, data storage and internet-connectivity, removing need for additional hardware for data post-processing. Based on the estimated body postures, WMDs risks can be conviently gauged by using existing WMDs risk assesment methods such as OWAS, RULA, REBA, etc.

Development of Multichannel On-line Thermometry System (다 채널 직결 온도측정 시스템의 설계 및 제작)

  • Shin, Sei-One;Shin, Hyun-Jin;Kim, Myung-Se;Kim, Sung-Kyu
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.193-199
    • /
    • 1999
  • Background: Measurement of body temperature is an important parameter in patient management in many clinical conditions. Failure to reach minimal acceptable body temperature standards has been associated with physiological derangements and has necessitated the application of additional therapy. The authors developed a new, simple, accurate thermometry system, which could be used to undertake precise temperature measurement for various clinical conditions. Materials and Methods: A new thermometry system using a specially designed temperature detecting and display system was developed. This system contains a temperature detecting sensor(LM 35CZ), which enables multiple serial checking of heat, data collection and processing computer, and 3-dimensional display system. It provides real time volumetric visualization of temperature distribution of a defined volume and stores and prints the data. Results: With this system, temperature can be measured at multiple interesting sites simultaneously, demonstrated as a 3-dimensional temperature distribution and stored. In well-controlled, systematic experiments a significant correlation has been observed between standard temperature and temperature using this system at various measuring points. Conclusion: This thermometry system is a real-time measurement system, which can demonstrate 3-dimensional heat distribution in experimental phantom and human body and can be used for diagnosing abnormal clinical conditions. In addition, this system reduces the nursing staff work load, providing them more time for long term care to patients.

  • PDF

Axillary temperature measurements based on smart wearable thermometers in South Korean children: comparison with tympanic temperature measurements

  • Choi, Younglee;Ahn, Hye Young
    • Child Health Nursing Research
    • /
    • v.28 no.1
    • /
    • pp.62-69
    • /
    • 2022
  • Purpose: This study explored the validity of a new type of thermometer and parent satisfaction with the new device. This 24-hour continuous monitoring smart wearable wireless thermometer (TempTraq®) uses a very small semiconductor sensor with a thin patch-like shape. Methods: We obtained 397 sets of TempTraq® axillary temperatures and tympanic temperatures from 44 pediatric patients. Agreement between the axillary and tympanic measurements, as well as the validity of the TempTraq® axillary temperatures, were evaluated. Satisfaction surveys were completed by 41 caregivers after the measurements. Results: The TempTraq® axillary temperatures demonstrated a strong positive correlation with the tympanic temperatures. The Bland-Altman plot and analysis of TempTraq® axillary temperatures and tympanic temperatures showed that the mean difference was +0.45 ℃, the 95% limits of agreement were -0.57 to +1.46 ℃. Based on a tympanic temperature of 38 ℃, the results of validity of fever detection were sensitivity 0.85 and specificity 0.86. Satisfaction scores for TempTraq® temperature measurement were all > 4 points (satisfactory). Conclusion: TempTraq® smart axillary temperature measurement is an appropriate method for measuring children's temperatures since it was highly correlated to tympanic temperatures, had a reliable level of sensitivity and specificity, and could be used safely and conveniently.

A Study on the Wear Fitness of Brassiere (Brassiere의 적합성에 관한 연구)

  • Yoon Hae Gyung;Choi Suk Chul
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.14 no.2
    • /
    • pp.117-128
    • /
    • 1990
  • The purpose of this study is to find fitness of brassiere by means of body measuring value, its variation volume, the evaluation of perceptive image, and the evaluation of the sense of wearing. The results were as follows; 1) According to comparison for body measuring value before and after wearing brassiere, bust point (B.P.) height, lower bust height, upper chest circumference, chest circumference, and bust depth are increased, and lower chest circumference, bust point breadth, shoulder middle point - B.P., B.P. -under bust, and cup horizontal girth are decreased. 2) The difference of variation volume by material is not accepted. The part above $20\%$ at variation rate is under the region of the armpit, that is, the region connected arm from the back. 3) The subjects replied that they wore the brassiere in order to compensate the breast and needed to wear it regardless of thiness and obesity. They wore the brassiere in order to dress themselves in good shape, and felt that it put pressure upon the body, while it had nothing to do with adjusting bodily temperature and gave the sense of security. 4) The estimate of the sense of wearing by material is recognized as the difference of the attention at attentive level $1\%$. The multiple factor analysis of each item in the sense of wearing showed that the items which are explained over $90\%$ by common factors are '1. Unpreasant in touch', '2. The part of edge is haggard', '15. Not to be fit'.

  • PDF

Development of Medical Infrared Imaging System (의료용 적외선 영상장치의 구현)

  • Lee, Soo-Yeol;Woo, Eung-Je;Cho, Min-Hyung;Song, Hyung-Bin
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.17-20
    • /
    • 1993
  • With proper designs of infrared optic system and two dimensional scanning mechanism, a medical infrared imaging system has been developed. The infrared imaging system can be used for two dimensional imaging of surface temperature of human body by measuring the amount of infrared lights radiating from it. It hag been experimentally proven that the degree of temperature measurement accuracy of the developed system is under $0.1^{\circ}C$ with spatial resolution of 1 mrad, image matrix size of $256{\times}240$, and imaging time of 4 seconds.

  • PDF

Measurement of electron density of atmospheric pressure Ar plasma jet by using Michelson interferometer

  • Lim, Jun-Sup;Hong, Young June;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.195.1-195.1
    • /
    • 2016
  • Currently, as Plasma application is expanded to the industrial and medical industrial, low temperature plasma applications became important. Especially in medical and biology, many researchers have studied about generated radical species in atmospheric pressure low temperature plasma directly adapted to human body. Therefore, so measurement their plasma parameter is very important work and is widely studied all around world. One of the plasma parameters is electron density and it is closely relative to radical production through the plasma source. some kinds of method to measuring the electron density are Thomson scattering spectroscopy and Millimeter-wave transmission measurement. But most methods have very expensive cost and complex configuration to composed of experiment system. We selected Michelson interferometer system which is very cheap and simple to setting up, so we tried to measuring electron density by laser interferometer with laser beam chopping module for measurement of temporal phase difference in plasma jet. To measuring electron density at atmospheric pressure Ar plasma jet, we obtained the temporal phase shift signal of interferometer. Phase difference of interferometer can occur because of change by refractive index of electron density in plasma jet. The electron density was able to estimate with this phase difference values by using physical formula about refractive index change of external electromagnetic wave in plasma. Our guiding laser used Helium-Neon laser of the centered wavelength of 632 nm. We installed chopper module which can make a 4kHz pulse laser signal at the laser front side. In this experiment, we obtained more exact synchronized phase difference between with and without plasma jet than reported data at last year. Especially, we found the phase difference between time range of discharge current. Electron density is changed from Townsend discharge's electron bombardment, so we observed the phase difference phenomenon and calculated the temporal electron density by using phase shift. In our result, we suggest that the electron density have approximately range between 1014~ 1015 cm-3 in atmospheric pressure Ar plasma jet.

  • PDF

A Study on the Skin Characteristics of Qi Deficiency and Blood Deficiency Animal Model (기허(氣虛), 혈허(血虛) 동물모형(動物模型)의 일반(一般) 특성(特性) 및 피부(皮膚) 특성(特性) 연구(硏究))

  • Shin, Yoon-Jin;Kim, Yoon-Bum
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.22 no.1
    • /
    • pp.76-88
    • /
    • 2009
  • Back ground and Objective : There is a need for objectification and scientific verification of Pattern identification in Oriental medicine. The purpose of this study was to investigate the skin characteristics of Qi deficiency and Blood deficiency animal models. Material and Methods : Sprague-Dawley rats were divided into three groups: normal group, Qi deficiency group and Blood deficiency group. The Qi deficiency animal model was induced through restriction of food (75g/kg/day) for 20 days. Blood deficiency animal model was induced by bleeding from tail vein(0.3 ml/time) 8 times. The normal animal model was kept without any intervention. The general condition was observed by measuring body weight, body temperature, blood pressure, pulse rate, and hematological and biochemical parameters. The skin characteristics were observed by measuring the erythema index(EI), melanin index(Ml), transepidermal water loss(TEWL) and dermal microcirculation. Results : 1. In the Qi deficiency group, body weight was lower than the other groups. In the Qi deficiency group, blood pressure was lower than in the Normal group. There was no difference in body temperature and pulse rate between the three groups. 2. In the Qi deficiency group, blood sugar was lower than in the Blood deficiency group. There was no difference in triacylglycerol between the three groups. In the Qi deficiency group, the WBC count was lower than in the Blood deficiency group. RBC count was highest in the Qi deficiency group, Normal group and Blood deficiency group respectively. In the Qi deficiency group, Hb and Hct were higher than the other groups. 3. EI and MI were decreased in the Qi deficiency group, and EI showed a significant decrease. 4. EI and MI were increased in the Blood deficiency group, and MI showed a significant increase. 5. TEWL was significantly increased in the Qi deficiency group, while it was decreased in the Blood deficiency group, TEWL was highest in the Qi deficiency group, Normal group and Blood deficiency group respectively and all three groups showed significant difference. 6. In the Qi deficiency group, dermal microcirculation was lower than the other groups. Conclusion : The above results show that the erythema index decreases in the Qi deficiency model, and the melanin index increases in the Blood deficiency model. The Qi deficiency animal model shows an increase in transepidermal water loss, while the Blood deficiency animal model shows a decrease. Further studies should develop new models of Pattern Identification that are more specific.

  • PDF

The Electric and Thermal Properties of Spark Plasma Sintered Bi0.5Sb1.5Te3 (방전플라즈마 소결된 Bi0.5Sb1.5Te3의 열/전기적 특성)

  • Lee, Gil-Geun;Choi, Young-Hoon;Ha, Gook-Hyun
    • Journal of Powder Materials
    • /
    • v.19 no.4
    • /
    • pp.285-290
    • /
    • 2012
  • The present study was focused on the analysis of the electric and thermal properties of spark plasma sintered $Bi_{0.5}Sb_{1.5}Te_3$ thermoelectric material. The crystal structure, microstructure, electric and thermal properties of the sintered body were evaluated by measuring XRD, SEM, electric resistivity, Hall effect and thermal conductivity. The $Bi_{0.5}Sb_{1.5}Te_3$ sintered body showed anisotropic crystal structure. The c-axis of the $Bi_{0.5}Sb_{1.5}Te_3$ crystal aligned in a parallel direction with applied pressure during spark plasma sintering. The degree of the crystal alignment increased with increasing sintering temperature and sintering time. The electric resistivity and thermal conductivity of the $Bi_{0.5}Sb_{1.5}Te_3$ sintered body showed anisotropic characteristics result from crystal alignment.