• Title/Summary/Keyword: body shaper

Search Result 4, Processing Time 0.017 seconds

Evaluation of Efficacy of Body Shaper for Senior Women Using 3D Scanned Data (3차원 데이터를 활용하여 시니어를 대상으로 한 바디쉐이퍼의 보정기능성 평가)

  • Kim, Soyoung;Hong, Kyunghi;Lee, Heeran
    • Fashion & Textile Research Journal
    • /
    • v.21 no.2
    • /
    • pp.220-230
    • /
    • 2019
  • The Fourth Industrial Revolution has increased studies on observing the cross section by overlapping the clothing worn using 3D human body data. However, there is a lack of studies on the effect of pressure clothing that contracts the shape of the human body. Therefore, this study objectively evaluated the shaping functionality of body shapers using 3D scan and 3D data. Two types of commercial body shapers were selected for this study. The nude body and body wearing body shapers were then scanned. A 3D program evaluated the shaping functionality by overlapping the nude state with the body wearing body shaper A and B respectively. As a result, it was found that the effect of body shapers could be adequately observed according to body parts. The smaller body shaper was shown to have superior shaping capability with the abdomen more affected. Analysis of the horizontal cross section indicated that the waist circumference decreased by 6 cm when wearing body shaper A and decreased by 12cm when wearing body shaper B. The volume of the waist part decreased by 8.6% when wearing body shaper A and by 20.4% when wearing body shaper B. Therefore, it is more effective to compare the objective shaping functionality by body parts using the overlapped 3D scanned data rather than using exterior evaluation or length measurement when wearing clothing that contracts the body shape.

Analysis of Clothing Pressure of Commercial Body Shapers using 3D Printed Torso Dummy for Middle-aged Women (중년 여성용 3D 프린팅 토르소 더미를 사용한 시판 바디쉐이퍼 제품의 의복압 분석)

  • Do, Wolhee;Lee, Jeongeun
    • Fashion & Textile Research Journal
    • /
    • v.23 no.6
    • /
    • pp.810-825
    • /
    • 2021
  • This study measured and analyzed clothing pressure at each measurement part of commercial body shapers to provide basic information for product design and clothing pressure standard and level. This study used five body shaper. Clothing pressure measurements were taken at 18points: Anterior area 8points, lateral area 5points, posterior area 5points. The findings of this study were as follows. As a result of measuring the clothing pressure, the body shaper 1 showed the highest pressure, and body shaper 5 showed the lowest pressure at almost of the measurement points of the three body types. In some cases, body shapers 2, 3, and 4 showed different orders of pressure depending on the measurement point. The highest measured values in most body shapers were the P1 shoulder area and the P2 bust area. The lowest measurement area differed by body type, but mainly P3 underbust area, P4 thorax area and P9 axillary area, P11 waist lateral area, P13 hip lateral area. These body shapers showed different results depending on the the manufacturers and body type of middle-aged women, and because there was no standard for the pressure value. Therefore, it is necessary to design a body shaper sizing system after accurately setting the clothing pressure value for each body part of the consumer.

A Suppression of Residual Vibration on the Flexible Structures by Input Shaping (입력설계기법에 의한 유연구조물의 잔류진동제어)

  • Park, Myoungho;Han, Myoungseok;Park, Sungjong
    • 대한공업교육학회지
    • /
    • v.31 no.2
    • /
    • pp.364-380
    • /
    • 2006
  • This paper presents a procedure for designing command to maneuver flexible structure with very little residual vibration, even in the presence of modeling errors. For the open loop maneuver, the various shaped profiles using multiple step inputs delayed in time are considered for robustness and compared with the responses of rigid body and flexible body in virtue of simulations and experiments. Input shaping generates vibration-reducing shaped commands through convolution of an impulse sequence with the desired command. A flexible model with a cylindrical hub and four symmetric appendages is considered to examine the responses to real plant, and to illustrate the effectiveness of the proposed shapers. The appendages are long and flexible, leading to low frequency vibration under any control action. It is shown by a series of simulation that a properly designed feedback controller with input shaper performs well, as compared with open loop controller with input shaper. The control objective is to achieve a fast settling time of residual vibration to flexible structure and robustness (insensitivity)to plant uncertainty, to eliminate residual vibration.

Comparison of shaping ability using various Nickel-Titanium rotary files and hybrid technique (다양한 전동 니켈 티타늄 파일과 혼합사용법에 의한 근관 성형 효율 비교)

  • Kim, Jung-Won;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.530-541
    • /
    • 2007
  • Currently, various Nickel-Titanium rotary files are used in endodontic treatment, but there is no one perfect system that can be applied to any clinical situation. Therefore, the combined uses of various file systems which can emphasize the advantages of each system are introduced as hybrid instrumentation. The ProTaper system is efficient in body shaping and apical pre-enlargement but is reported to have more possibility of transportation and produce more aberrations and deformation in more or less severe curved canals. Recently, new ProTaper system(ProTaper Universal) with different configuration and cross-sectional design to overcome the week points of ProTaper have been marketed. The purpose of this study was to compare and evaluate the shaping abilities of ProTaper, ProTaper Universal system, and two hybrid methods using S-series of ProTaper Universal and Hero Shaper or ProFile. The time lapses for instrumentation were measured and the used files were inspected for distortion. The pre- and post-instrumented root canals were scanned and superimposed to evaluate the aberrations and reduction of root canal curvature and change of radius of canal curvature. The increased canal width and apical centering ratio were calculated at 1, 2, 3, 4 and 5 mm levels from apical foramen. Under the conditions of this study, the ProTaper Universal seems to have better shaping ability than ProTaper in terms of instrumented width and instrumentation time. It may be suggested that the ProTaper Universal system is efficient as much as hybrid instrumentation using ProTaper and other constant-tapered NiTi file systems in highly experienced operators.