• 제목/요약/키워드: body measurement

Search Result 2,429, Processing Time 0.035 seconds

Body Shape Measurement Using Stereo Photo (입체사진을 위용한 인체형상계측)

  • Choe, Hyeok-Ju;Seong, Gyeong-Hwa;Lee, Hyeon-Jik
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.5
    • /
    • pp.664-675
    • /
    • 1998
  • The purpose of this study was to isolate the observational error included in plane photogrammetric data and suggest more accurate and suitable method for body shape measurement. Three experiments were carried out in this study. First of all, the variables which can be obtained from photogrammetric method were selected among the data which can be measured improperly by direct measurement or showing large deviations between the samples. Secondly, the height, the width and the depth of 50 subjects were measured by plane photogrammetry. The result showed that plane photogrammetric data contain significant observational error even for the same variables, as the angle of which photos had been taken changes. Therefore, in order to reduce the observational error and to measure the human body accurately, three-dimensional measurement, stereo photogrammetry was employed in the last experiment. As it is important to isolateonly the observational error by plane photogrammetry and to exclude the accidental error caused by movement of human body subject, body shape model(manikin) was used as subject. The result showed that the average observational error by plane photogrammetry was more than 4 cm in the height, 0.85-1.29cm in the width and 0.49cm in the depth. In conclusion, it is not adequate to use the height obtained from plane photogrammetric data as human body measurement data. And the width and the depth should be used cautiously, even though they are relatively less significant, the error still can make some difference on clothing construction.

  • PDF

A Study for Quality Improvement of Three-dimensional Body Measurement Data (3차원 인체치수 조사 자료의 품질 개선을 위한 연구)

  • Park, Sun-Mi;Nam, Yun-Ja;Park, Jin-Woo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.117-124
    • /
    • 2009
  • To inspect the quality of data collected from a large-scale body measurement and investigation project, it is necessary to establish a proper data editing process. The three-dimensional body measurement may have measuring errors caused from measurer's proficiency or changes in the subject's posture. And it may also have errors caused in the process of algorithm expressing the information obtained from the three-dimensional scanner into numerical values, and in the course of data-processing dealing with numerous data for individuals. When those errors are found, the quality of the measured data is deteriorated, and they consequently reduce the quality of statistics which was conducted on the basis of it. Therefore this study intends to suggest a new way to improve the quality of the data collected from the three-dimensional body measurement by proposing a working procedure identifying data errors and correcting them from the whole data processing procedure-collecting, processing, and analyzing- of the 2004 Size Korea Three-dimensional Body Measurement Project. This study was carried out into three stages: Firstly, we detected erroneous data by examining of logical relations among variables under each edit rule. Secondly, we detected suspicious data through independent examination of individual variable value by sex and age. Finally, we examined scatter-plot matrix of many variables to consider the relationships among them. This simple graphical tool helps us to find out whether some suspicious data exist in the data set or not. As a result of this study, we detected some erroneous data included in the raw data. We figured out that the main errors are not because of the system errors that the three-dimensional body measurement system has but because of the subject's original three-dimensional shape data. Therefore by correcting some erroneous data, we have enhanced data quality.

Diagnosis Accuracy Rate Comparative Study of Each Sasang Constitutions and Sex Distinction by Body Measurement Method between 3D Body Measuring Instrument and Hand-operating (3D체형측정기와 수동측정 방법간의 사상체질별 ${\cdot}$ 성별 진단정확률 비교연구)

  • Kwon, Suk-Dong;Sul, Yu-Kyung;Lee, Eui-Ju;Kim, Kyu-Kon;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.1
    • /
    • pp.60-77
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method and Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated Width 5 Places and hand-operated circumference 8 place,Automatic Width 5 and automatic circumference 8 place by 3D body measuring instrument) and analyzed the anthropometric data divding into sex&age. 362 patient's data are used in the analysis. 3. Results and Conclusions 1) 1th circumference variable which standing was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement was 50-80%. 3) Diagnostic accuracy rate of man is higher than Diagnostic accuracy rate of women 4) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

Comparison of Caliper and Ultrasound Measurement for the Estimation of Body Fat (체지방량 추정을 위한 초음파피지후계와 Caliper의 비교)

  • 정진욱
    • Journal of Nutrition and Health
    • /
    • v.28 no.4
    • /
    • pp.282-290
    • /
    • 1995
  • Subcutaneous fat thickness of 74 young male was measured at six sites(biceps, triceps, subscapula, suprailiac, abdomen, thigh). The present study compared caliper with ultrasound measurements for the estimation of body fat. Caliper measurements subcutaneous at six sites had higher coefficient variation than did the ultrasound measures. Caliper measurements subcutaneous at six sites had higher ratio (caliper/ultrasound) than did the ultrasound measures. Compared to other body sites, the correlations between caliper and ultrasound measurements were high for the subscapula(r=0.7327), abdomen(r=0.7355) and thigh (r=0.7207) sites. the correlations between caliper and ultrasound measurements were high for the suprailiac(r=0.6616) site by lean group. the correlations between caliper and ultrasound measurements were high for the abdomen(r=0.7636) site by normal group. The correlations between caliper and ultrasound measurements were high for the subscapula (r=0.8959) and abdomen(r=0.8237) sites by obese group. Ultrasound measurement of biceps(r=-0.4459), abdomen9r=-0.4469), thigh(r=-0.4348) had the highest correlation with body density. Caliper measurement of triceps(r=-0.4017), subscapula(r=-0.4454), abdomen(r=-0.4293) had the highest correlation with body density. Ultasound measurements subcutaneous fat at lean group, obese group had higher coefficients of correlation with body density than did the caliper measurement. Caliper measurements subcutaneous fat at normal group had higher coefficients of correlation with body density than did the ultrasound measures. Ultrasound showed to be superior to the caliper technique in measuring subcutaneous fat of obese persons.

  • PDF

The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner - (3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 -)

  • Park, Sun-Mi;Nam, Yun-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.1
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

A Study on the Measurement of the Breast Shape on Living Body by Using a PMP Moire Method (가슴형상 측정을 위한 PMP Moire 방법 활용)

  • Lee, Ga-Na;Yuk, Keun-Cheol;Kim, Byeong-Mee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.11 no.2
    • /
    • pp.11-21
    • /
    • 2009
  • Recently, as custom-made demand about female underwear is increased, securing of a various dimension system is urgent, and satisfaction of each customer cannot be heightened with established dimensions. If we could measure shape of a living body with a fast and simple method, the custom-made demand of customers could be satisfied in the underwear as well as a clothing industry by using the method. One of the alternatives is shape measurement of the living body by a Moire fringe method. If we put a grating in front of an object to be measured and illuminate light, a Moire fringe with contour line shape is generated in the object, so we can conveniently measure object shape without touching directly by using the pattern. The Moire fringe and three-dimensional shape of the breast of the living body was acquired by a PMP method using a polygon mirror, and height and bottom width of the breast of the living body were measured by using obtained data in this study. Data of breast shape measurement through a mannequin was collected in a previous step as basic material for measuring the breast shape measurement of the living body. Three women in the twenties were selected as one of methods for measuring breast shape of a woman. As a result of the breast shape measurement of a living body A, it was measured that height of the breast was about 67.24mm and the bottom width was $13781.60mm^2$. This study is expected to contribute for collecting basic data of a female underwear industry and establishing a specification of a dimension system.

  • PDF

Analysis of Clothing Pressure of Commercial Body Shapers using 3D Printed Torso Dummy for Middle-aged Women (중년 여성용 3D 프린팅 토르소 더미를 사용한 시판 바디쉐이퍼 제품의 의복압 분석)

  • Do, Wolhee;Lee, Jeongeun
    • Fashion & Textile Research Journal
    • /
    • v.23 no.6
    • /
    • pp.810-825
    • /
    • 2021
  • This study measured and analyzed clothing pressure at each measurement part of commercial body shapers to provide basic information for product design and clothing pressure standard and level. This study used five body shaper. Clothing pressure measurements were taken at 18points: Anterior area 8points, lateral area 5points, posterior area 5points. The findings of this study were as follows. As a result of measuring the clothing pressure, the body shaper 1 showed the highest pressure, and body shaper 5 showed the lowest pressure at almost of the measurement points of the three body types. In some cases, body shapers 2, 3, and 4 showed different orders of pressure depending on the measurement point. The highest measured values in most body shapers were the P1 shoulder area and the P2 bust area. The lowest measurement area differed by body type, but mainly P3 underbust area, P4 thorax area and P9 axillary area, P11 waist lateral area, P13 hip lateral area. These body shapers showed different results depending on the the manufacturers and body type of middle-aged women, and because there was no standard for the pressure value. Therefore, it is necessary to design a body shaper sizing system after accurately setting the clothing pressure value for each body part of the consumer.

A Study on Target Ages and Sizes of Korean Women′s Ready-made Clothes (한국 성인여자 기성복 브랜드의 타깃 연령 및 생산사이즈에 관한 실태조사 연구)

  • 조영아
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.4
    • /
    • pp.549-561
    • /
    • 2000
  • The purpose of this study was to survey and analyze the age classification of women customers as a target market and sizes on a label that were actually produced by each brand in Korean national brands ; they were classified into size for bodice and bottom, and compared with the distribution of national data of women's body measurement. They were analyzed and classified by brand groups of 'miss', 'missy', 'Mrs.'and 'madam', The results were ; 1) It was found that recent products for ready-made for women's clothes tend to be designed with target to the measured ages classified by the range of five or ten years. The main practice was that for 'miss'brand group the age range was of five years, and for 'missy'brand group, ten years. And for 'Mrs'and 'madam'brand groups, it was of 15 or 20 years. So that, it is necessary to design their clothes based on their features of body considering the intervals of age. 2) 'Mrs'and 'madam'groups were most remarkable for their distribution into a vast range of sizes for three control dimensions and waist girth size when compared to 'miss'and 'missy'groups. The distribution of brand size had no relation with that of body measurement, and in particular, none was produced for short height size between 145 and 150 ㎝. For tall height size between 175 and 180 ㎝, many brand sizes were distributed while body measurement was few. It means that distribution of brand size was different from real distribution of body measurement was few. It means that distribution of brand size was different from real distribution of body measurement as a result that the larger the bust girth in such cases over 160 ㎝, the larger the size of hip girth. Even as for the height 155 and 160 ㎝ in which body measurement is concentrated, there were many problems because while sizes of 'large'bust girth and 'small'hip girth had a large distribution, their clothes were not produced.

  • PDF

A Study on Weld Bead Profile Measurement System for Use in Automatic Weld Bead Removal System

  • Lee, Jeong-Woo;Lee, Eun-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.194-197
    • /
    • 1999
  • Automatic weld bead removal system is consisted of bead removal tool, bead profile measurement system and tool motion control system. In this paper, design of weld bead profile measurement system which is used for automatic weld bead removal system is described. The system measures the weld bead position, normal vector of the auto-body and weld bead profile. The optical sensor with structured laser beam is used as a sensor and comparison of the sensor that can be used for this purpose is discussed in detail. The measurement process and the related software developed for this purpose are also described. A median filter, average filter and long line filters are used and their effects in bead profile measurement are discussed. The measurement system is integrated into automatic bead removal system and is used to remove weld bead in rear pillar of automotive body. The whole system operates well in automotive body assembly line and thus the system is proved to be good for this purpose.

  • PDF

Validity of Bioelectrical Impedance Analysis(BIA) in Measurement of Human Body Composition (소아 체지방 평가를 위한 생체 저항분석법의 타당성 연구 : 이중 에너지 방사선 흡수법과의 비교)

  • Kim, Hyung-Suck;Kim, Su-Yung
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.7
    • /
    • pp.696-700
    • /
    • 2005
  • Propose : Body composition by bioelectrical impedance analysis(BIA) is a very useful method of analysing body composition. BIA is non-invasive, inexpensive, nonhazaedous and reproducible technique. The aim of this study was to determine the level of agreement between body composition measurement by BIA and dual-energy X-ray absorptiometry(DEXA). Methods : Data was examined in 100 children(male 58; female 42), who visited Pusan National Hospital. Weight(kg) and height(cm) were measured, and body compositions were analyzed with fat mass, lean body mass, body fat percent by BIA and DEXA methods. Results : Comparison of the DEXA and BIA methods showed highly statistically significant correlations in measurement of human body composition(fat mass, lean body mass, body fat percent). Conclusion : BIA should be considered as the method of choice in measurement of human body composition, since it's non-invasive, reliable, rapid, nonhazaedous and inexpensive, using portable equipment.