A Theoretical Analysis on Somatotyping of Elderly Women (노년기 여성의 체형 연구에 대한 이론적 분석)

  • Lee, Eun-Jung
    • Journal of the Korean Society of Fashion and Beauty
    • /
    • v.4 no.1 s.7
    • /
    • pp.35-41
    • /
    • 2006
  • From 1995 to 2005 the information related to clothing and textiles publicized by 6 journals regarding Elder Women's body type was collected and analyzed. The results are as follows. 1. It has been investigated into the elder woman's body type since 1995, and this subject needs a detailed study. in audition, investigation into woman's body type has been studied parts of the body for clothing construction. 2. Analysis result for measure area preponderance(Seoul area and local metropolitan city) of area, measure subject number mainly to large scale group more than 300 people that measure is consisting most know can. 3. Where the way of measurement is concerned, there are direct measurements more than indirect measurements. In case of using just direct measurement, the study often mentions necessity of indirect measurements. Therefore it is thought simultaneous measurement is the most desirable. 4. A Body type characteristic of elder woman shows a size of every part diminishes as growing older. Owing mainly to obesity of waist and abdomen, they have a changed body a measure of around the abdomen is bigger than around the hips. hips drop and the upper half of the body down, and besides, feet are changed into the flat.

  • PDF

Body Size Measurement Method Using a Elastic Band and Digital Camera (엘라스틱 밴드와 디지털 카메라를 이용한 신체 치수 측정 방법)

  • Choi, Gi-Rak;Kim, Hyeon-seok;Lee, Jong-Hyeok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.553-556
    • /
    • 2015
  • In almost all of the Hand-made suit plants, while garment cutters are hard to measure the body size by their own, they are not quick. And each of the individual's standard is vague, so it is hard to get a consistency. So it will give the customers some displeasure with the body contact. To improve this kind of problems, in this paper proposes a efficient way that is hard to measure by the general image processing technology to measure when you manufacture a Hand-made suit and measure a body size by wearing a elastic band that has a printed mark that has some information of length and taking a picture of the body by a digital camera.

  • PDF

A Study on the Production of Made-to-measure Clothes for Middle-aged Women - Focused on Ready-to-wear Manufacturers - (중년여성복(中年女性服)의 맞춤생산(生産)에 대(對)한 실태연구(實態硏究) - 기성복업체(旣成服業體)를 중심(中心)으로 -)

  • Kim, So-Ra
    • Journal of Fashion Business
    • /
    • v.5 no.4
    • /
    • pp.1-13
    • /
    • 2001
  • The purpose of this study was to research production situation of made-to-measure clothes of ready-towear manufacturers for middle-aged women. This study will be the basis of developing production model of mass customized clothing for middle-aged women. For the questionnaire, 18 ready-to-wear manufacturers, which were producing made-to-measure clothes and in higher ranking of sales, were selected and the pattern makers of the manufacturers were questioned about 29 items for this research. The results of the questionnaire were as follows: 1. The production ratio of made-to-measure clothes was increasing and most manufacturers have problems making fitted clothes for each customer. 2. The most common reason to order made-to-measure clothes was the sizes according to the various somatotypes and the proportion difference of a body. 3. The common somatotypes of upper body for made-to-measure clothes were obesity, large bust, bent forward posture, and leaning back posture. 4. The common somatotypes of lower body for made-to-measure clothes were obesity, prominent abdomen, prominent abdomen-prominent hip, and prominent hip. 5. Pattern making for made-to-measure clothes was to use production patterns or make new patterns.

  • PDF

A Study on The Fat Measurement at Subcutaneous Adipose by Optical and Electrical Method (광전 방식에 의한 피하 지방층의 비만도 측정에 관한 연구)

  • Oh, Se-Yong;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.405-407
    • /
    • 2008
  • Body fat measures a large number places body because error is oversized that measure in single specification region to measure body whole body fat degree by non-invasive optical method and bio-electrical impedance method. Use LED source of light that center wavelength is 660nm wavelength and measure at same time by BIA(Bio-electrical Impedance Analysis) method And then photo-electricity method calculate fat correlation formula.

  • PDF

Effective Body Signal Measurement with the Bioelectric Impedance Analysis (효율적인 생체 임피던스 신호 측정에 관한 연구)

  • Oh, Se-Yong;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.689-692
    • /
    • 2005
  • Bioelectrical Impedance Analysis(BIA) can measure body water amount and then body fat mass. Locate 4 electrode in palm to measure efficiently and flow current(50kHz, 800uA) in body for measuring voltage and capacitance. And proposed method to measure body fat with hight, weight, age and distinction of sex.

  • PDF

A Study of Body Surface Area Calculation -Centering around 40 Ages- (체표면적 산출식에 관한 연구 -40대 여성을 중심으로-)

  • Im, Soon
    • The Research Journal of the Costume Culture
    • /
    • v.2 no.2
    • /
    • pp.385-394
    • /
    • 1994
  • Data of the body surface is a necessary unit for the measuring of metabolism energy and activity energy. And also, these data are referring to check the degree of retaining warmth of clothes, to find the effect of heat insulation according to body surface, to calculate an average temperature of skin, and to study the several fields of clothing. In measuring of body surface, it si actually impossible to measure a subject's body surface in each experiment. As the experimental method, both gypsum method, by which the shape of body an be copied as it is, and the weighting method from which planed body surface area can be measured with consistent thickness of polyprophylene film as used. In fact, every female subject feels uncomfortable to measure her body surface as a naked body. There, it is providing a simple, accurate regressive equation with weight & height as variable factors in this study. This equation is as=117.02W+77.31H-3344.94 with average error : 0.1%, absolute average error : 2.07%.

  • PDF

A study on body cathexis and clothing satisfaction of married women. (기혼 여성들의 신체만족도와 의복만족도에 관하여)

  • 김용숙
    • Journal of the Korean Home Economics Association
    • /
    • v.24 no.3
    • /
    • pp.1-9
    • /
    • 1986
  • The purpose of this study was to measure the body cathexis and clothing satisfaction sccording to the level of age, job, and total monthly income and to investigate the relationship between body cathexis and clothing satisfaction of married women. 43 items of body parts and body functions were selected to measure body cathexis from Secord and jourard body Cathexis scale. A nd 56 items of Mclean's Clothing Satisfac tion scale were used for clothing satisfaction. The questionnaires were administered to 384 mothers in Jeonbug province. 3-way ANOVA and Newman-Keuls test were used for group difference. Pearson's Correlation Coefficients, Partial Correlation Coefficients, Standard Deviation, and Mean were calculated. RESULTS : 1. Body cathexis of married women showed asignificant difference according to age. 2. Clothing satisfaction of married women showed a significant difference to the interaction of age, job, and total monthly income. The elder and higher income group without job had the highest clothing satisfaction scores than any other group. 3. Positive correlations were found among body cathexis, clothing satisfaction, and 6 subscales of clothing satisfaction.

  • PDF

A Study on Body Temperature Measurement of Woven Textile Electrode Using Lock-In-Amp based on Microprocessor (마이크로 프로세서 기반 Lock-In-Amp를 이용한 텍스타일 직물전극의 체온 측정에 관한 연구)

  • Lee, Kang-Hwi;Lee, Sung-Su;Lee, Jeong-Whan;Song, Ha-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1141-1148
    • /
    • 2017
  • Generally, a thermistor made by sintering a metal oxide is widely used to measure the ambient temperature. This thermistor is widely used not only for industrial use but also for medical use because of its excellent sensitivity, durability, temperature change characteristics and low cost. In particular, the normal body temperature is 36.9 degrees relative to the armpit temperature, and it is most closely related to the circulating blood flow. Previous studies have shown that body temperature changes during biomechanical changes and body temperature changes by anomalous signs or illnesses. Therefore, in this study, we propose a Lock-In-Amp design to detect minute temperature changes of clothing and thermistor wired by a preacher as a method to regularly measure body temperature in daily life. Especially, it is designed to measure the minute resistance change of the thermistor according to body temperature change even in a low-cost microprocessor environment by using a micro-processor-based Lock-In-Amp, and a jacquard and the thermistor is arranged so as to be close to the side, so that the reference body temperature can be easily measured. The temperature was measured and stored in real time using short-range wireless communication for non - restraint temperature monitoring. A baby vest was made to verify its performance through temperature experiments for infants. The measurement of infant body temperature through the existing skin sensor or thermometer has limitations in monitoring infant body temperature for a long time without restriction. However, it can be overcome by using the embroidery fabric based micro temperature monitoring wireless monitoring device proposed in this study.

Clinical efficacy of Gyeongshingangjeehwan16 according to obeisty related to measurement variables. (신체부위별 측정변인에 따른 경신강지환16의 비만 개선효과 평가)

  • Jung, Yang-Sam;Yoon, Ki-Hyeon;Choi, Seung-Bae;Yoon, Mi-Chung;Shin, Soon-Shik
    • Herbal Formula Science
    • /
    • v.16 no.1
    • /
    • pp.169-183
    • /
    • 2008
  • In this study, we measured body mass index, visceral fat ratio and 6 parts of body, neck circumference, circumference of upper arm, chest circumference, abdomen circumference, hip circumference, and thigh circumference by bioimpedence analysis system, after taking Gyeongshingangjeehwan16 (GGEx16) in five months except the first period before taking GGEx16 on 49 women who are obesity or high-level obesity. In order to examine the significance test for the effect of obesity improvement of GGEx16, we practices repeated measure ANOVA with values of measurement variables in 6 monthly times. As a result of all measurement variables, there were significant difference (P-value=0.001). Therefore, we can say that GGEx16 is effective about obesity improvement. As it dramatically decreased between second measure period and first measure period for all measure variables, we can see that there were the most effect of GGEx16 in the first time after taking GGEx16. It is known that a important measurement variable to have a effect for obesity improvement about two variable which are body mass index and visceral fat ratio is waist circumference through correlation analysis. The result of whether there are differences to effect of obesity improvement for GGEx16 around the climacteric, there were significant difference for the effect of obesity improvement for GGEx16 around the climacteric about all parts of body (P-value=0.001). There were also powerfully difference in effect of obesity improvement for GGEx16 around the climacteric about all parts of body (P-value=0.001). Especially, the climacteric before is more effective than the climacteric after in the aspect of the effect of GGEx16.

  • PDF

Upper Body Measurement of Men using 3D Body Scanner -Compared to Anthropometry- (3차원 바디 스캐너를 이용한 남성 상반신 인체측정 -직접측정과의 비교-)

  • Paek, Kyung-Ja;Lee, Jeong-Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.1
    • /
    • pp.24-34
    • /
    • 2008
  • Three dimensional body scan technology is being targeted for utilization in the apparel industry. The purpose of this study was to test reliability of the body scan data targeting from 20 to 24 year old men by comparing 3DM, 3D body-scanning semi-auto measurement extraction method, Scanworx, 3D body-scanning auto measurement extraction method, and traditional anthropometric method. We found significant differences in 9 out of 25 items in upper body measurements using 3DM and 16 out of 25 items using Scanworx. In the range of difference value of scan measures, it showed 1 item in the absolute value of more than 40mm between two measuring methods, 3 items in 20 up to 40mm, and less than 20mm in other items. Overall, in height items, the numerical value of traditional measure was higher and in girth, width, depth items, 3D scan measure was higher. We found out that reliability of 3D measurements taken from whole body scans was different according to scanners, scanning softwares, programs, and subjects.