• 제목/요약/키워드: body fluid

검색결과 1,320건 처리시간 0.027초

건망(健忘)의 변증분형(辨證分型)에 대(對)한 연구(硏究) (A Bibliographic Study on the Types of Differential Diagnosis of Amnesia)

  • 최용준;성강경;문병순
    • 대한한의학회지
    • /
    • 제17권1호
    • /
    • pp.374-406
    • /
    • 1996
  • This study has been carried out to investigate the types of differential diagnosis of amnesia. The results are as follows; 1. Amnesia has various types of differential diagnosis(辨證分型) ; deficiency of both the heart and spleen(心脾兩虛型), deficiency of the heart(心虛型), deficiency of the kidney(腎虛型), breakdown of the coordination between the heart and the kidney(心腎不交型), mental confusion due to phlegm(痰迷心竅型), accumulation of stagnant blood(蓄血型), internal injury by seven emotion (七情所傷型). 2. The type of deficiency of both the heart and spleen(心脾兩虛型) occurs when the heart and spleen is injured by overthinking(思慮過度), The symptoms are heart palpitation(心悸), continuous palpitation(??), insomnia(少寐), hypochondric discomfort(心煩), dream disturbed sleep(多夢), being easy to be scared(易驚), dizziness(眩暈), these are caused by blood deficiency of the heart(心血不足), poor appetite(飮食不振), loss of appetite(納?), short breath(氣短), sense of turgid abdormen(腹部膨滿感), loose stool(泥狀便), these are caused by deficiency of the spleen(脾虛), lassitude and weakness (身倦乏力), lassitude of the extremities (四肢無力), dim complexion (面色少華), pale lips(舌質淡), thready and feeble(脈細弱無力), these are caused by deficiency of both qi and the blood(氣血虛損). The remedy is nourishing the heart-blood(養心血) and regulating the spleen(理脾土). I can prescribe the recipes such as Guibitang(歸脾湯), Gagambosimtang(加減補心湯), Seongbitang(醒脾湯), Insin-guisadan(引神歸舍丹), Insamyangyoungtang(人蔘養榮湯), Sojungjihwan(小定志丸), Yungjigo(寧志膏), Palmijungjihwan(八味定志丸), etc., 3. The type of deficiency of the heart(心虛型) occurs when the heart-blood is injured by the mental tiredness(神勞) and so blood cannot nourish the heart. The symptoms are amnesia(健忘), short breath(氣短), heart palpitation(心悸), perspire spontaneously(自汗), facial pallidness(顔面蒼白), pale lips (舌質淡白), feeble pulse and lassitude(脈虛無力), intermittent pulse(結代脈). The remedy is nourishing the hart and blood and allaying restlessness(補心益血安神). I can prescribe the recipes such as Chenwangbosimdan(天王補心丹), Jeongji-hwan(定志丸), Gaesimhwan(開心丸), Youngjigo(寧志膏), Chilseonghwan(七聖丸), Baegseogyoungtang(白石英湯), Oseohwan(烏犀丸), Yangsinhwan(養神丸), Guisindan(歸神丹), Bogsinsan(茯神散), Jinsamyohyangsan(辰砂妙香散), Cheongeumboksinsan(千金茯神散), Samjotang(蔘棗湯), jangwonhwan(壯元丸), Sa gunjatang(四君子湯) minus rhizoma atractylodis macrocephalae(白朮) plus rhizoma acori graminei(石菖蒲), radix polygalae(遠志), cinnabaris(朱砂), etc. 4. The type of deficiency of the kidney(腎虛型) occurs when the kidney-qi and kidney-essence is deficient(腎氣腎精不足) and so it cannot nourish the brain. The symptoms arc amnesia(健忘), ache at the waist and lassitude in the lower extremities(腰산腿軟), dizziness and tinnitus(頭暈耳嗚), emmission and premature ejaculation(遺精早泄), burning sensation of the five centres(五心煩熱), flushed tongue(舌紅), rapid and small palse(脈細數). The remedy is nourishing the kidney and strengthen the essence(補腎益精). I can prescribe the recipes such as Gagamgobonhwan(加減固本丸), Jeongjihwan(定志丸), Gongseongchlmjungdan(孔聖枕中丹), Yugmigihwanghwan(六味地黃丸) plus ra-dix polygalae(遠志), fructus schizandrae(五味子), Yugmigihwanghwan(六味地黃丸) plus radix polygalae(遠志), fructus schizandrae(五味子), rhizoma acori graminei(石菖蒲), semen zizyphi spinosae(酸棗仁), Palmihwan(八味丸) plus fructus schizandrae(五味子), semen zizyphi spinosae(酸棗仁). etc., 5. The type of breakdown of the coordination between the heart and the kidney (心腎不交型) occurs when the heart-fire(心火) and kidney-fluid(腎水) are imbalanced. The symptoms are amnesia(健忘), hypochondric discomfort(心煩), insomnia(失眠), dizziness and tinnitus(頭最耳嗚), feverish sensation m the palms and soles(手足心熱), emmision(遺精), ache at the waist and lassitude in the lower extremities(腰?腿軟), flushed tongue(舌紅), rapid pulse(脈數). The remedy is coordinating each other(交通心腎). I can prescribe the recipes such as Gangsimdan(降心丹), Jujaghwan(朱雀丸), Singyotang(神交湯), Simsinyang- gyotang(心腎兩交湯), Yugmihwan(六味丸) plus fructus schizandrae(五味子), radix polygalae(遠志), Yugmihwan(六味丸) plus fructus schizandrae(五味子), radix polygalae(遠志), rhizoma acari graminei(石菖蒲), semen zizyphi spinosae(酸棗仁), etc., 6. The type of mental confusion due to phlegm(痰迷心竅型) occurs when the depressed vital energy(氣鬱) create phlegm retention(痰飮) and phlegm stagnancy(痰濁) put the heart and sprit(心神) out of order. The symptoms arc amnesia(健忘), dizziness(頭暈), chest distress(胸悶), nausea(惡心), dull(神思欠敏), dull and slow facial expression(表情遲鈍), tongue with yellow and greasy fur(舌苔黃?), sliperry pulse(脈滑). The remedy is removing heat from the heart to restore consciousness and dispersing phlegm(淸心化痰開竅) I can prescribe the recipes such as Gamibogryeongtang(加味茯?湯), Goa-rujisiltang(瓜蔞枳實湯), Jusaansinhwan(朱砂安神丸), Dodamtang(導痰湯) plus radix saussurea(木香), Yijintang(二陳湯) plus succus phyllostachyos(竹瀝), rhizoma zingiberis(生薑) Ondamtang(溫膽湯) plus rhizoma acori graminei(石菖蒲), rhizoma curcumae aromaticae(鬱金), etc., 7. The type of accumulation of stagnant blood(蓄血型) occurs when the blood is accumulated in the lower part of body. The symptoms are amnesia(健忘), chest distress(胸悶), icteric skin(身黃), rinsing the mouth but don't wanting eat(漱水不欲燕), madness(發狂), black stool(屎黑), pain in the lower abdomen(小腹硬痛). The remedy is dispersing phlegm and absorb clots (化痰化瘀), I can prescribe the recipes such as Jeodangtang(抵當湯), Daejeodanghwan(代抵當丸), Hyeolbuchugeotang (血府逐瘀湯) plus rhizoma acori graminei (石菖蒲), rhizoma curcumae aromaticae(鬱金), Jusaansinhwan(朱砂安神丸) plus rhizoma curcumae aromaticae(鬱金), radix polygalae(遠志), semen persicae(桃仁), cortex moutan radicis(收丹皮), etc., 8. The type of internal injury by seven emotion(七情所傷型) occurs when the anger injures the will stored in the kidney(腎志). The symptoms are amnesia(健忘), heart palpitation(心悸). hot temper(易怒), being easy to be scared(善驚), panic(易恐). The remedy is relieving the depressed liver and regulating the circulation of qi(疏肝解鬱). I can prescribe the recipes such as Tongultang(通鬱湯), Sihosogantang(柴胡疏肝湯) plus rhizoma acari graminei(石菖蒲), rhizoma curcumae aromaticae(鬱金), etc.

  • PDF

단풍나무류 8종의 초식에 대한 방어전략 탐색 (A Study of the Defense Mechanism against Herbivores of 8 Species of the Genus Acer)

  • 김갑태;류동표;김회진
    • 한국환경생태학회지
    • /
    • 제23권5호
    • /
    • pp.411-417
    • /
    • 2009
  • 목본식물의 초식에 대한 방어 전략을 알아보고자 8종의 단풍나무속 수종의 잎에 대하여 형태적 특성, domatia 구조와 수, 초식곤충과 응애 서식 여부 등을 관찰 조사하였다. 조사대상 수목들은 강원도 치악산, 청태산, 방태산, 태백산과 윈주시에 생육 중인 8수종에서 엽시료를 채취하여 2009년 4월부터 7월까지 관찰, 조사하였다. 얻어진 결과는 다음과 같다. 당단풍, 고로쇠 및 복장나무의 domatia는 tuft type, 단풍나무, 신나무, 복자기와 시닥나무는 pocket+tuft type, 산겨릅나무는 pocket type 임이 밝혀졌다. 엽당 domatia 평균 갯수는 산겨릅나무에서 20.2개/엽으로 가장 많았고, 신나무에서 4.2개/엽으로 가장 적었다. 엽표면의 털은 단풍나무, 당단풍, 신나무 및 복장나무는 응모(villous), 고로쇠나무와 복자기는 연모(pilose), 시닥나무는 강모(strigose)였다. 일반적으로 털의 밀도는 잎 뒷면이 앞면보다 높았다. 단풍나무, 당단풍, 산겨릅나무 및 시닥나무에서만 엽맥의 말단부에 소량의 단물이 분비됨을 확인하였다. 엽당 응애의 개체수는 수종간 고도의 통계적 유의성이 인정되었으며, 엽당 응애 개체수 평균은 시닥나무가 9.2마리로 가장 많았으며, 다음으로 복장나무, 당단풍, 복자기가 순이었다. 단풍나무류 잎을 가해하는 미소절지동물류는 진사진딧물, 단풍알락진딧물, 나무이, 혹응애, 매미충 등이었으며, 총개체수는 혹응애, 진사진딧물, 나무이, 단풍알락진딧물, 매미충 순이었다. 이들의 천적으로는 육식성 응애, 말벌, 그 약충, 광대노린재 약충, 등이 확인되었으며, 고동털개미와 곰개미는 진딧물과 상리공생을 하여 단풍나무류의 초식피해를 가중시킴을 확인하였다. 육식성 응애가 진사진딧물을 공격하여 체액을 빨아먹는 것을 확인하였으면, 이는 domatia가 중재하는 응애와 식물의 상리공생의 증거라 판단된다. 이러한 결과는 온대 활엽수종에서 이러한 응애와의 상리공생이 보편화되어 있음을 암시하는 것이라 사료된다.

소아 개심술에 있어서 변형초여과법의 효과 (Effects of Modified Ultrafiltration in Pediatric Open Heart Surgery)

  • 전태국;박표원
    • Journal of Chest Surgery
    • /
    • 제30권6호
    • /
    • pp.591-597
    • /
    • 1997
  • 개심술시 사용되는 체외순환에 따른 혈액희석, 염증성반응 등으로 인하여 개심술후 혈관외용적 증가 및 조직내 수분증가로 인하며 심장 및 폐기능 저하는 잘 알려진 사실이며 특히 소아에서는 심한 경우에는 장 기부전이 초래 될 수 있다. 본 연구는 여러가지 장점을 갖고 있는 변형초여과법을 임상적용하여 개심술 직 후 심폐기능에 미치는 영향을 평가하고자 하였다. 연구 A): 1996년 4월부터 1996년 8월 까지 삼성의료원 흉부외과에서 변형초여과법을 실시한 총 71명의 환자중 전향적연구을 실시한 소아환자 26명을 대상으로 하여 변형초여과법전후의 혈역학적 수치를 비교하 였다. 변형초여과법 전후의 .적혈구 용적량은 28.3$\pm$3.6%에서 33.8$\pm$4.0%로 증가 (P<0.001), 중심정맥압은 7.8 k3.7mmHg에서 6.9$\pm$2.gmmHg로 감소하였으며(PfO.001), 수축기 혈압은 66.7$\pm$11.2mmH프에서 76.2 11.8 mmHg로 증가하였다( p < 0.02). 연구 B): 변형초여과법이 폐에 미치는영향을 평가하기 위하여 2세 미만의 심실중격결손 환자중 변형초여 과법군(12명)과 초여과법을 적용하지 않은 대조군(14명)으로 하여 수술직후 최대호기압, 폐포-모세혈관 산소 분압차, 기관지 삽관기\ulcorner 등을 비교하였다. 최대호기압은 각각 20.0$\pm$2.4cm1120,22.4$\pm$2.3cm1120로 변형초여 과법군이 의미 있게 낮았으며(p<0.03), 폐포-모세혈관 산소분압차 및 기관지 상관기간은 변형초여과법 적용 군에서 낮았으나, 통계적으로 유의한 차이는 없었다. 상기연구를 통하여 변형초여과법을 사용함으써 효과적으로 혈액을 농축시킬수 있으며, 더 낮은 중심정맥 암에서 더 높은 수축기 혈압 등의 혈역학적 이득이 있으며, 술후 폐포-모세혈관 산소분압차 및 최대호기압 의 감소 등, 폐기능 향상의 효과가 있음을 알 수 있었다. 본 연구팀은 향후 계속적으로 소아 개심술후 변 형초여과법을 적용하여 이에 대한 효과.및 기전에 대한 연구를 계속시행할 예정이다.

  • PDF

소아 개심술에 있어서 변형 초여과법(Modified Ultrafiltration)이 술후 상태에 미치는 영향 (Effect of Modified Ultrafiltration on the Postoperative State after Pediatric Open Heart Surgery.)

  • 방종경;천종록;김규태
    • Journal of Chest Surgery
    • /
    • 제31권5호
    • /
    • pp.456-465
    • /
    • 1998
  • 개심술후에 영아나 작은 소아에서는 수분의 체내 저류현상이 더욱 심하게 나타난다. 이에 대한 치료법의 하나로 개심술시 변형 초여과법을 적용함으로써 술후 상태에 미치는 영향을 알아 보고자 하였다. 개심술을 받았던 5세이하의 소아를 대상으로 개심술후 변형 초여과법을 적용하였던 환아(초여과군) 10명과 초여과법을 실시하지 않았던 대조군 10명의 2군으로 나누어서 개심술에 따른 조기 성적을 비교 분석하였다. 환아의 연령, 체중, 심폐기 충진액의 총량과 이에 첨가한 혈액의 양, 그리고 체외순환시간과 대동맥차단시간 등의 값들은 모두 양군간에 유의한 차이가 없었다. 변형 초여과법을 적용함에 있어서 관류속도는 평균 171.4ml/min, 관류시간은 평균 18.9분이 소요되었고, 이 동안에 걸러진 수액의 총량은 평균 38.4ml/kg, 심폐기의 혈액을 환자에게 재수혈한 양은 평균 32.1ml/kg였다. 술후 24시간동안의 출혈량은 초여과군에서 평균 14.5ml/kg/24hr, 대조군에서 13.7ml/kg/24hr였고, 같은 기간에 수혈한 양은 초여과군에서 전혈 6.6ml/kg/24hr, 혈장 65.7ml/kg/24hr, 대조군에서는 전혈 15.2ml/kg/24hr, 혈장 59.6ml/kg/24hr이었다. 이는 임상적으로는 초여과군에서 전혈의 수혈량이 대조군에 비하여 훨씬 적어 보였지만 통계학적으로 유의한 차이는 없었다. 술전후 적혈구용적률의 변화는, 초여과군에서는 체외순환 시작후 10분에 평균값이 26.5%로 떨어졌다가 초여과법 종료 5분후에는 37.1%로 급격히 상승하였고, 대조군에서는 체외순환중의 24.7%에서 체외순환이 끝나고 20분이 경과한 후에도 30.5% 수준으로밖에 상승하지 못하였다. 그러므로 적혈구용적률의 변화를 체외순환중의 수치에 대한 상승률(%)로 나타냈을 때, 초여과군은 40%, 대조군은 23%로써 양군간에 통계학적으로 유의한 차이를 보였다(p=0.002). 초여과법 시행에 따른 수축기 및 이완기동맥압의 변화에 있어서는 양군간에 유의한 차이가 없었으며, 평균동맥압의 변화는 양군간에 통계학적으로 유의한 차이는 없었으나(p=0.086), 임상적으로는 상당한 차이를 보였다. 결론적으로, 소아환자에서 개심술후에 변형 초여과법을 적용했을 때, 거의 일률적으로 적혈구용적률과 동맥혈압이 상승함을 볼 수 있었고, 이는 환아를 중환자실로 옮긴 후에도 지속됨으로써 개심술직후 환아관리에 긍정적인 효과를 발휘하는 것으로 평가된다. 따라서 향후 영아나 작은 소아의 개심술에 있어서 변형 초여과법은 보다 많은 빈도로 이용될 것으로 전망된다.

  • PDF

괭생이 모자반 추출물의 비장세포 면역활성 증강 효과 (Splenocyte-mediated immune enhancing activity of Sargassum horneri extracts)

  • 김동섭;성낙윤;한인준;이병수;박상윤;노은영;엄지;김건;김경아
    • Journal of Nutrition and Health
    • /
    • 제52권6호
    • /
    • pp.515-528
    • /
    • 2019
  • 본 연구는 괭생이 모자반 추출물의 추출방법에 따른 면역증강활성에 관하여 비교 관찰하였고, 추출물간의 혼합비율을 다르게 혼합하여 제조한 괭생이 모자반 추출물의 최적 면역활성을 갖는 혼합비를 평가하였다. 비장세포에 괭생이 모자반 열수 (HWE), 주정 (EE), 초임계 (SFE) 추출물을 각각 처리하였을 때 HWE 및 SFE 처리구에서 비장세포 증식능 및 사이토카인 (IL-2, IFN-γ) 분비능이 높게 나타나는 것으로 관찰되었고, 각각의 추출물을 50, 100 mg/kg BW의 농도로 2주간 마우스에 투여하고 비장을 적출하여 비장세포 활성능에 관하여 관찰한 결과, HWE 및 SFE 투여구에서 비장세포 증식능 및 사이토카인 분비능이 높게 나타나는 것으로 관찰되었다. 동물실험에서 높은 활성을 보인 HWE와 SFE의 추출물의 혼합 최적비를 평가하기 위하여 HWE에 SFE를 5, 10, 15 및 20%로 혼합하여 대식세포에 처리하여 NO 및 사이토카인 분비능에 관하여 관찰한 결과, SFE를 5%, 10% 혼합한 추출물 처리구에서 활성이 높게 나타나는 것으로 관찰되었으며 혼합추출물을 100 mg/kg BW으로 14일간 투여한 마우스의 비장세포 활성에 관하여 관찰한 결과, SFE를 5%의 비율로 혼합한 추출물 처리구 비장세포 활성이 높게 나타나는 것으로 관찰되어 HWE와 SFE의 최적 혼합 비율을 HWE에 SFE를 5% 첨가하는 것으로 결정하였다. 결정된 최적혼합비로 100 mg/kg BW의 농도로 14일간 투여한 마우스의 비장세포에서 NK 세포를 분리하여 NK 세포의 활성능을 평가한 결과, 대조구 대비 높게 증가하는 것으로 나타났다. 따라서 괭생이 모자반 추출물을 최적비율로 혼합하여 제조한 혼합추출물은 비장세포, 대식세포 및 NK 세포에 대한 높은 활성능을 나타내어 면역증진에 기여하는 것으로 판단된다.

중국 호남성 시죽원 광상의 W-Sn-Bi-Mo광화작용 (W-Sn-Bi-Mo Mineralization of Shizhuyuan deposit, Hunan Province, China)

  • 윤경무;김상중;이현구;이찬희
    • 자원환경지질
    • /
    • 제35권3호
    • /
    • pp.179-189
    • /
    • 2002
  • 중국 호남성 침주시에서 북동 16 km지점에 위치하는 시죽원 다금속 광상의 지질은 원생대의 변성퇴적암류, 데본기탄산염암, 쥬라기 화강암류, 백악기 반암류 및 초염기성맥암으로 구성된다. 시죽일 다금속 광상은 중-조립질 흑운모화강암과 관련되어 있다. 광체의 산출상태, 광물의 산출상태 및 공생관계를 토대로 광화시기는 스카른, 그라이젠 및 열수시기로 나뉜다. 스카른 시기의 광체는 주로 Ca-스카른으로 천리산 화강암체 주변에 발달되며, 석류석, 휘석, 베수비아나이트, 규회석, 각섬석, 형석, 녹염석, 방해석, 회중석, 철망간중석, 휘창연석, 휘수연석, 석석, 자연창연, 미확인 Bi-Te-S계 광물, 자철석 및 적철석 등이 산출된다. 그라이젠 시기는 중-조립질 흑운모화강암의 잔류용액과 관련되며, 광체는 판상 및 맥상으로 구분된다. 이 시기는 주로 석영, 장석, 백운모, 녹니석, 전기석, 황옥, 녹주석, 인회석, 회중석, 철망간중석, 휘수연석, 휘창연석, 석석, 자연창연, 미확인 우라늄광물, 미확인 희토류광물로 구성되고, 소량의 황철석, 자철석, 황동석, 적철석 등이 산출된다. 회중석은 누대조직을 보이며, 중심부에서 MoO$_3$ 함량이 9.17%로 외곽보다 높게 나타난다. 철망간중석의 화학조성은 WO$_3$; 71.20~77.37 wt.%, FeO; 9.37~18.4 wt.%, MnO; 8.17~15.31 wt.% 및 CaO; 0.01~4.82 wt.% 이다. 석석의 FeO 함량은 1.30~4.75 wt.%이고, 스카른 시기가 높은 함량을 보인다. 자연창연의 Te 및 Se 함량은 각각 0.00~1.06 wt.%와 0.00~0.57 wt.%이다. 미확인 Bi-Te-S 계 광물은 Bl: 78.62~80.75 wt.%, Te: 12.26~14.76 wt.%, Cu; 0.00~0.42 wt.%, S; 5.68~6.84 wt.%, Se; 0.44~0.78 wt.%.이다.

복분자와 클로렐라 혼합물의 젖산발효 최적조건 및 품질 특성 (Optimal Lactic Acid Fermentation Conditions and Quality Properties for Rubus coreanus Miquel (Bokbunja) and Chlorella Mixtures)

  • 김재영;이상욱;김나형;문광현;백승화
    • 한국식품영양과학회지
    • /
    • 제45권3호
    • /
    • pp.386-395
    • /
    • 2016
  • 본 연구는 복분자와 클로렐라 혼합물의 기능성 발효제품을 개발하고자 품질 특성을 최대화할 수 있는 최적 발효조건을 확립하고, 확립된 방법으로 제조한 혼합 발효물의 일반성분, 유리당, 유기산, 항균 활성 등 화학적 특성에 대한 품질 특성을 조사하였다. 먼저 복분자와 클로렐라 젖산발효 혼합물의 최적 발효균주를 확인한 결과 젖산 생성이 Lactobacillus plantarum에서 가장 우수한 것으로 평가되었고, 최적 발효 온도는 $37^{\circ}C$였다. 이와 같은 조건으로 복분자와 클로렐라 젖산발효 혼합물을 제조하여 관능평가를 한 결과 종합적 기호도 측면에서 클로렐라 분말 5% 첨가구가 가장 우수한 것으로 평가되었다. 따라서 시판 복분자 착즙액(Rubus coreanus Miquel juice; RCM)과 복분자와 클로렐라 5% 첨가 젖산발효 혼합물(RCM-C5)을 제조하여 일반성분, 유리당, 유기산, 항균 활성 등 품질 특성을 조사하였다. RCM과 비교하여 RCM-C5는 수분의 경우 4.90%, 건량 기준 총당은 14.15%, 건량 기준 조섬유는 0.32% 감소하였다. 한편 건량 기준으로 조단백질, 조지방, 조회분은 각각 13.75%, 0.18%, 0.73% 증가하였다. 색도는 두 시료 모두 밝고 약간의 황색을 띠는 적색이었지만 RCM-C5가 RCM보다 황색을 더 띠었다. RCM과 비교하여 RCM-C5의 유리당 함량은 0.97%, 유기산 함량은 616.30 mg%, 항균 활성은 그람양성균인 Staphylococcus aureus가 5.83%, 그람음성균인 Escherichia coil와 Salmonella Typhimurium은 각각 2.94%, 4.67% 증가하였다. 이상의 결과로 미루어본바 일반 복분자 시제품보다 복분자와 클로렐라 젖산발효 혼합물의 품질 특성이 향상되는 결과를 나타내어, 이를 실제 제품으로 제조한다면 영양 기능성이 풍부한 기능성 발효식품으로 활용이 가능할 것으로 판단된다.

유육종증 전국실태조사 (National Survey of Sarcoidosis in Korea)

  • 대한결핵 및 호흡기학회 학술위원회
    • Tuberculosis and Respiratory Diseases
    • /
    • 제39권6호
    • /
    • pp.453-473
    • /
    • 1992
  • 연구배경 : 전국 실태조사를 통하여 현재까지 확진된 전국의 유육종증 발생현황을 파악하고 이를 분석하고 외국의 보고와 비교하여 일반 개업의 및 내과 전문개업의 진료활동에 도움이 되도록 하고자 하였다. 방법 : 조사와 분석기간은 1991년 1월부터 1992년 12월까지 2년간으로 정하였으며 자료수집방법은 후향적 방법으로 입원실이 100병상 이상인 213개 종합병원의 내과, 안과, 피부과, 신경내과에 서신을 통한 경험증례를 수집 하였으며 확진예나 의심예가 있었던 경우에 유육종증 증례 기록지를 보내어 정확한 임상 및 검사정보를 수집하여 분석하였다. 결과 : 1) 제 1 차 설문엽서 발송은 입원실이 100병상 이상인 213개 종합병원의 내과, 안과, 피부과, 신경내과의 523개과 과장 및 호흡기 내과를 담당하는 전문의에게 발송하였다. 내과가 213개과로 41%, 피부과가 1087개과로 20%, 안과가 104개과로 20%, 신경과가 100개과로 19%를 차지하였다. 2) 제 1 차 설문조사에 대한 답신은 241개과에서 연락이 있었다(48% 회신율). 3) 확진예 및 의심예는 총 50개과 113예 및 10예가 있다고 보고되었으며 내과가 92예로 81%, 피부과 15예로 13%, 안과, 신경과가 각 3예로 3%를 차지하였다. 자료분석은 총 78예에서 시행되었고 내과 72예로 92%, 피부과 4예로 5%, 신경과 2예로 3%를 차지하였다. 4) 1980년 1에보고 이후 증례가 많은 수로 증가하여 1989년 13예, 19901건 17예, 1991년 18예가 보고되었다. 5) 진단 당시의 연령은 20대, 30대, 40대가 84.4%로 대부분을 차지하고 있었다. 6) 남녀비는 1 : 1.5의 비율로 여자 환자가 많았다. 7) 진단을 받게된 동기로 주소의 빈도로는 호흡기 증상이 48%로 가장 많았고, 피부의 병변, 전신증상, 시각장애, 관절통, 복통, 연하곤란의 순서이었고 무증상이 12예(16%)이었다. 8) 초증상에서 확진을 받을때까지 중앙치는 2개월이었다. 9) 증상의 반도로는 호흡기 증상, 전신증상, 피부증상, 눈 증상, 말초림프구 종창, 신경계증상, 심장증상의 순이었다. 10) 말초혈액검사 소견상 혈색소, 혈구용적치 및 혈소판수는 대부분 정상범위를 나타냈다. 58%의 증례에서 30%미만의 림프구 감소증을 나타냈으며, 임파구 아형으로 T4/T8비는 1.73{\pm}1.16$(0.43~4.62)였다. 43%에서 혈침속도가 상승하였다. 11) 혈청 생화학검사는 대부분 정상범위를 이었다. 혈청 ACE 농도의 평균치는 $66.8{\pm}58.6$(8.8~265) U/L로서 46.2%에서 증가되었다. 42.9%에서 하루 150 mg 이상의 단백뇨 소견을 나타냈고, 36.8%가 하루 300 mg이상의 단백뇨 소견을 나타냈다. 12) 면역학적 검사상 혈청 IgG는 43.5%, IgA는 45.5%, lgM은 59.1%, IgE는 46.7%에서 상승되었고, C3 및 C4는 대부분 정상범위 였으며, ANA는 11%에서 양성을 보였다. Kveim test는 시행된 3예에서 모두 양성을 나타냈다. 13) 폐기능검사중 FVC는 80% 미만인 경우가 17.3%, FEV1은 70% 미만인 경우가 11.5% FEV1/FVC는 70% 미만인 경우가 10%, TLC는 80% 미만인 경우가 15.2%, DLCO는 100% 미만인 경우가 64.7%이었다. 14) 동맥혈가스 분석소견은 PaO2가 90mmHg 미만인 경우가 48.6%, PaCO2는 평균 45mmHg보다 증가된 경우보다 5.7%이었다. 15) 기관지 폐포세척액 검사상 대식세포의 평균 백분율은 $51.4{\pm}19.2%$였고, 임파구의 평균 백분율은 $44.4{\pm}21.1$이였다. 임파구아형은 T4/T8 ratio는 $3.41{\pm}2.07$이였다. 16) 전 검사항목에 대한 남녀 성별간의 유의한 차이는 없었다. 17) 흉부방사선의 분석에서 폐문 임파절 비대를 보인례는 87.9%였고, 78.8%에서는 양측성병변을 9.1%에 일측성 병변을 보였다. 18) Siltzbach의 분류에 의한 병기 구분시 stage 0 : 5%, stage 1 : 58.3%, stage 2 : 28.3%, stage 3 : 8.3%의 분포를 보였다. 19) 흉부 CT를 시행한 54예에서 폐문임파절비대는 50예(92.6%)에서 보였고 이들 중 47예는 양측성 비대였다. 20) 고해상도 CT는 16예에서 시행하였는데, 2예에서는 병변이 없었으며, 폐실질의 병변은 결정성 병변, 소엽간 중격비후, 반점상 국소 폐음영의 순으로 나타났다. 21) 부수적으로 시행한 방사선학적 검사에서 골병변은 1예에서 수근골의 병변을 보였고, 초음파검사에서 2에에서 비장비대의 소견을 보였다. 22) 갈륨스캔은 12에에서 시행하여 폐문 및 종격동 임파절의 흡수증가 소견이 8예에서 보였고, 폐장의 흡수증가는 2예에서 보였다. 23) 조직검사상 가장 많이 시행한 진단방법은 경기관지 폐생검 47.3%이었고, 피부와 종격동 임파절 생검은 각각 34.5%, 말초임파절생검 23.6%, 개흉 폐생검 18.2%, 기관지생검이 16.2%이었다. 2가지 이상의 부위에서 조직검사를 시행한 경우는 52.7%이었다. 한 부위에서만 조직검사를 시행한 26예중 종격동 임파절 생검은 10예, 피부생검 6예, 말초임파절 생검 5예, 개흉폐생검 3예 그리고 경기관지 폐생검 2예이었다. 24) 병리소견상 비건락성 육아종은 100% 모두에서 관찰되었며, 다핵거대 세포는 47.3%, 봉입체는 10.9%, 초자질 섬유화는 34.5%, 괴사 9.1%, reticulin fibrils network 20%, lymphangitic distribution of granuloma 1.8%에서 관찰되었다. 결론 : 유육종 전국 실태조사에 따른 영상소견, 검사실소견, 방사선소견, 병리소견을 분석해 본 결과, 우리나라 유육종 환자들도 다소 차이는 있었지만 외국의 보고들과 유사한 소견들을 나타냈으며, 향후로는 이들에 대한 결과들을 추가분석하여, 유육종 진단에 도움을 줄 수 있고, 임상적 지표로 이용될 수 있는 검사항목을 찾아내는 것이 과제라 할 수 있겠다. 유육종증에 대한 자료는 대한 결핵 맺 호흡기학회에 보관이 되어 있음을 알려드립니다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF