• Title/Summary/Keyword: body cooling method

Search Result 57, Processing Time 0.022 seconds

Numerical study for performance analysis and design of a counterflow type cooling tower (대향류형 냉각탑에 대한 설계 및 성능해석을 위한 수치해석적 연구)

  • 이상윤;이정희;최영기;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.535-549
    • /
    • 1998
  • A numerical study for performance analysis of a counterflow type forced draft tower and natural draft cooling tower has been performed based on the method using the finite volume method with non-orthogonal body fitted and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy balance, moisture fraction balance, water enthalpy balance, and water mass balance equations are solved with Navier-Stoke’s equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study, The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also peformed.

  • PDF

Numerical Study for the Performance Analysis and Design of a Crossflow- Type Forced Draft Cooling Tower

  • Choi, Young-Ki;Kim, Byung-Jo;Lee, Sang-Yun;Lee, Jung-Hee
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.1
    • /
    • pp.1-13
    • /
    • 2000
  • A numerical study for performance analysis of a crossflow-type forced draft cooling tower has been performed based on the finite volume method with non-orthogonal body fitted, and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy, moisture fraction, water enthalpy, and water mass balance equations are solved with Navier-Stoke's equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study. The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also performed.

  • PDF

$SF_6$ Gas Insulated Transformer ($SF_6$가스절연 변압기)

  • Cho, G.J.;Cho, K.D.;Ha, Y.S.;Cho, K.B.;Noh, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.304-309
    • /
    • 1991
  • We introduce the trend, of several countries, to the gas insulated transformer recently coming into the spot light by the advantages of less weight, GIS-lization, low noise level and easiness to decrease environmental pollutions, and the insulating gases. the cooling media and the insulating materials used for transformer. Hereinafter, additively the design of proto type $SF_6$ gas insulated transformer (insulation, cooling), which was developed by us(HICO) from 1987. 2 through 1990. 3, the manufacturing processes(leak protection, pressure, drying of main body), the accessories, the protective system, the cooling system, the method and the results of test and the evaluation of economics compared with conventional oil-filled transformer are represented.

  • PDF

Whole-body Management System using Ultra-Low Temperature Cyclical Cooling Method Combined with IT Technology (IT 기술을 접목한 초저온 순환 냉각 방식의 전신 관리 시스템)

  • Kim, Joo-Ho;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.673-676
    • /
    • 2020
  • In this paper, we propose a whole-body management system using ultra-low temperature cyclical cooling method combined with IT technology. The proposed system has the following characteristics. First, it minimizes maintenance costs by circulating nitrogen gas cooled by ultra-low temperature inside the controller. Secondly, based on the information measured by the temperature sensor and oxygen concentration sensor, nitrogen gas is supplied to provide safe ultra-low temperature whole-body management. Thirdly, after entering the user's height, it provides convenient, ultra-low temperature whole-body care that can be controlled using an automatic lift. Fourth, it provides an easy-to-access, easy-to-manage GUI and a manager-only web program for whole-body management system operation. The results tested by the authorized testing agency to assess the performance of the proposed system were measured in the range of ±5%, the world's highest temperature sensor accuracy, and a range of -110℃ to -150℃ greater than the world's highest whole-body management temperature range(-110℃ ~ -140℃). In addition, humidity was measured at less than 40%, the world's highest, and oxygen concentration was more than 18%, the world's highest. Therefore, the effectiveness of the methods proposed in this paper was demonstrated because they produced the same results as the world's highest levels.

Surface Ageing Property of Polymer Insulator for Transmission line with Forest Fire Test (H종 주상용 몰드 변압기의 덕크구조에 따른 열해석 특성)

  • Cho, Han-Goo;Kim, Kyang-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.111-111
    • /
    • 2010
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. In this paper, the temperature distribution and thermal stress analysis of H class 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

Clinical application of cryolipolysis in Asian patients for subcutaneous fat reduction and body contouring

  • Oh, Chang Hyun;Shim, Jeong Su;Bae, Kwang Il;Chang, Jae Hoon
    • Archives of Plastic Surgery
    • /
    • v.47 no.1
    • /
    • pp.62-69
    • /
    • 2020
  • Background Cryolipolysis, a preferred method for minimally invasive body contouring, involves the noninvasive cooling of adipocytes to induce lipolysis without damaging other tissues. This study aimed to evaluate the safety and efficacy of cryolipolysis for the treatment of excessive fat tissue. Methods Between May 2014 and December 2017, 231 patients with 448 areas of interest were enrolled and their records were retrospectively reviewed. We used five different vacuum applicators, and the best-fitting applicator was used for each area. One cycle of cryolipolysis was applied at a cooling intensity factor of 41.6. The efficacy was evaluated 12 weeks after treatment via review of clinical photographs, the pinch test, and ultrasonographic measurements of fat thickness. The occurrence of any complications was also assessed. Results The volume was reduced in all of the areas to which cryolipolysis was applied. The rate of reduction of the fat layer as measured via the pinch test was 19.2%, and the rate of the decrease in fat layer thickness as measured via ultrasonography was 22.8%. Fat reduction of the upper arm differed significantly from that of the abdomen and flank, but no significant difference was found between sexes. The side effects were limited to erythema, edema, bruising, and numbness at the treatment site and resolved without treatment. Conclusions Cryolipolysis, with new and better-fitting applicators, is safe, fast, and effective for the reduction of excessive fat tissue on the abdomen, back, flank, and extremities. It is a good option for treating excess adipose tissue in Asian patients.

EFFECTS OF DIFFERENT COOLING TECHNIQUES ON DRAUGHT CAPACITY OF BUFFALO

  • Bunyavejchewin, P.;Kaewsomprasong, K.;Chotemethepirom, S.;Tanta-ngai, B.;Tajima, A.;Chikamune, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.4 no.2
    • /
    • pp.131-136
    • /
    • 1991
  • Four male swamp buffaloes weighing $460.5{\pm}44.6kg$ were used to study the effects of different cooling techniques on draught capacity. Each animal carted an 882 kg load on the same asphalt road for one hour during four different time periods: 9:00-10:00 A.M., 10:30-11:30 A.M., 2:00-3:00 P.M. and 3:30-4:30 P.M. Simultaneously, all animals were subjected to five different treatments on five days of similar environmental conditions. In Treatment 1, animals were put stationary in a field and did no work; in Treatment 2, animals were worked without any cooling method; in Treatment 3, fifteen-minute wallow was allowed to animals prior to working; in Treatment 4, animals were covered with wetted jute bags while working, and in Treatment 5, two buckets of water were poured over the buffaloes' trunks just prior to working. The experiment was conducted from April to July 1989, when the weather was very hot. It was found that cooling methods and working times did not affect the draught efficiency of buffaloes during the one hour, but did affect physiological traits. The work load had a larger partial effect on physiological responses of buffalo other than respiration rate than did climatic variables except on the respiration rate of the buffaloes. One cooling technique that seemed to slow the increase of body temperature while working was covering the buffalo's back with wetted jute bags. Animals working at different times had significant differences in the increase of physiological traits except pulse rate.

Noise Radiation Analysis of the Cooling Fan in a Heavy Equipment (중장비 팬의 엔진룸을 통한 소음방사 해석)

  • 정기훈;전완호;이덕주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.954-960
    • /
    • 2001
  • Axial fans are widely used in heavy machines due to their ability to produce high cooling of engines. At the same time. the noise generated by these fans causes or serious problems. This work is concerned with the low noise technique of discrete. The prediction model. which allowed the calculation of acoustic pressure at the frequency and it's harmonics, has been developed by Farrasat and the Helmholtz-Kir. The newly developed Helmholtz-Kirchhoff BEM for thin body is used to calculate the sound field of the fan that is located in a engine room. To calculate the unsteady resultant force over blade. Time-Marching Free-Wake Method are used. The fan noise of fan sys unsymmetric engine-room is predicted. In this paper. the discussion is confined to and discrete noise of axial fan and front Part of engine room in heavy equipments.

  • PDF

A Study on the Chattering Phenomena of a Check Valve (역지밸브 채터링 현상 해소방안 연구)

  • 유기완;이준신;김태룡
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.1
    • /
    • pp.36-41
    • /
    • 2002
  • The cause and the elimination method for the chattering phenomena were investigated in a check valve attached to the exit of an auxiliary cooling water pump in a Korean nuclear powerplant. From the site experiment and the numerical calculation, the incident angle of the disk was so small that it was not able to produce the sufficient lifting force to overcome the gravitational component of the disk weight. Moreover, it turned out that the installation position was not symmetric for the secondary vortical flow generated inside the elbow so that the flow structure had strongly unstable flow characteristics. From this study, the tapping noise and the chattering phenomena were eliminated exactly by changing the incidence angle of the valve disk and the installation position of the calve body.

Front Tracking Finite Element Analysis of Heat Transfer in Spray Forming Process (경계추적 유한요소법을 이용한 분무성형공정에서의 열전달 해석)

  • 장동훈;강신일
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.148-152
    • /
    • 1997
  • A numerical method is presented to predict and analyze the shape and the temperature history of a growing billet produced form the "spray forming" which is a fairly new near net-shape manufacturing process. It is important to understand the mechanism of billet growing and the cooling history of the spray deposited body, because one can obtain a billet with the desired final shape without secondary operations by accurate control of the billet shape and, moreover, growing velocity together with the cooling rate define the microstructure of the final formed product. In the present study, a theoretical model is first established to predict the shape of the billet and next the transient axisymmetric heat conduction problem with growing domain is solved using the so called "front tracking finite element technique".ent technique".uot;.

  • PDF