• Title/Summary/Keyword: body change

Search Result 3,990, Processing Time 0.03 seconds

Effect of Perch Type and Height on the Growth Performance, Behavioral Characteristics, and Meat Quality of Broilers (홰 종류 및 높이 설정에 따른 육계 생산성, 행동특성, 계육품질에 미치는 영향)

  • Kim, Hyunsoo;Kim, Hee-Jin;Jeon, Jin-Joo;Son, Jiseon;You, Are-Sun;Kang, Bo-Seok;Hong, Eui-Chul;Kang, Hwan-Ku
    • Korean Journal of Poultry Science
    • /
    • v.48 no.4
    • /
    • pp.227-238
    • /
    • 2021
  • This study investigates the effect of perch type and height on the growth performance, footpad dermatitis (FPD), blood parameters, behavioral characteristics, and meat quality of broilers. A total of 912 one-day-old male Ross 308 broilers (48.23±0.264 g) were subjected to a three x two factorial design of three types of perch (wood, steel, plastic) and two levels of perch height (10→30 cm change, 10 cm fixed) over a five-week experiment. Growth performance, perch availability, litter quality, FPD incidence, serum biochemical parameters, and meat quality of the broilers were evaluated. There were no significant differences in the body weight, feed conversion ratio, and biochemical parameters (except for aspartate aminotransferase), pH, color, and water holding capacity. The incidence of FPD was significantly higher in the plastic perch group than in the wood and steel perch groups (P<0.05) at five weeks of age. Perch use was high in the order of wood, steel, and plastic groups in the daytime and nighttime at one, three, and five weeks of age (P<0.05). Perch use was higher in the 10 cm fixed group than the 10→30 cm group (P<0.05). The shear force of the breast significantly increased in the order of wood, steel, and plastic groups (P<0.05). In conclusion, the group with a fixed perch height of 10 cm had high perch usage. Additionally, the use of wooden perches was higher than that of other materials, and it lowered the incidence of FPD in broilers.

The Radioprotection Effect of Dioscorea Quinqueloba Extracts on the Prostate and Heart in Male Rats (수컷 쥐 전립선과 심장에 대한 단풍마 추출물의 방사선 방호효과 연구)

  • Jae-Gyeong, Choi;Chang-Ju, Kim;Geun-Woo, Jeong;Sang-Hyun, Jeong;Sung-Hyun, Joo;Byung-In, Min
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.779-786
    • /
    • 2022
  • This study is designed to examine the effects of Dioscorea Quinqueloba extract as a natural radiation protection agent on the prostate and heart of male rats. Dioscorea Quinqueloba extract is well known to prevent the male-specific disease and heart disease. In this study, the Gamma-ray 10 Gy was irradiated in whole body of male rat to identify radioprotective effect by Dioscorea Quinqueloba extract. After irradiation, tissue change, SOD (Superoxide Dismutase) activity changes and hematological changes were observed. DQ+IR group showed higher lymphocyte, white blood cell, platelet levels than the IR group. In the NC and DQ groups, the number of prostate gland cells and the gap between cells were relatively narrow. But in the IR group, the cells died significantly and the gap widened. In the DQ+IR group, the gap between cells increased similarly to the IR group, but the number of dead cells was noticeably smaller. In the NC and DQ groups, the cardiovascular and myocardium are clearly separated, and cell nuclei are in good condition. But in the IR group, the cardiovascular and myocardium boundaries were disrupted, and the number of dead cell nuclei was high. In the DQ+IR group, although the boundaries were widened, but not disrupted and the number of dead cell nuclei was high. Therefore, Dioscorea Quinqueloba extract is judged to have radioprotective properties for the prostate and cardiovascular.

Development and Assessment of a Non-face-to-face Obesity-Management Program During the Pandemic (팬데믹 시기 비대면 비만관리 프로그램의 개발 및 평가)

  • Park, Eun Jin;Hwang, Tae-Yoon;Lee, Jung Jeung;Kim, Keonyeop
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.3
    • /
    • pp.166-180
    • /
    • 2022
  • Objective: This study evaluated the effects of a non-face-to-face obesity management program, implemented during the pandemic. Methods: The non-face-to-face obesity management program used the Intervention mapping protocol (IMP). The program was put into effect over the course of eight weeks, from September 14 to November 13, 2020 in 48 overweight and obese adults, who applied to participate through the Daegu Citizen Health Support Center. Results: IMP was first a needs assessment was conducted; second, goal setting for behavior change was established; third, evidence-based selection of arbitration method and performance strategy was performed; fourth, program design and validation; fifth, the program was run; and sixth, the results were evaluated. The average weight after participation in the program was reduced by 1.2kg, average WC decreased by 3cm, and average BMI decreased by 0.8kg/m2 (p<0.05). The results of the health behavior survey showed a positive improvement in lifestyle factors, including average daily intake calories, fruit intake, and time spent in walking exercise before and after participation in the program. A statistically significant difference was seen (p<0.05). The satisfaction level for program process evaluation was high, at 4.57±0.63 point. Conclusion: The non-face-to-face obesity management program was useful for obesity management for adults in communities, as it enables individual counseling by experts and active participation through self-body measurement and recording without restriction by time and place. However, the program had some restrictions on participation that may relate to the age of the subject, such as skill and comfort in using a mobile app.

Effect of Prepubertal Exposure to Di(2-ethylhexyl)phthalate on the Maturation of Rat Seminal Vesicles and Prostate Glands (사춘기 전 수컷 흰쥐의 저정낭과 전립선의 성숙에 미치는 Di(2-ethylhexyl) phthalate(DEHP)의 영향)

  • Heo, Hyun-Jin;Lee, Won-Yong;Yoon, Yong-Dal;Choi, Donchan;Lee, Sung-Ho
    • Development and Reproduction
    • /
    • v.12 no.3
    • /
    • pp.251-259
    • /
    • 2008
  • The plasticizer di(2-ethylhexyl)phthalate(DEHP) is one of the most well known endocrine disrupting chemicals (EDCs) because of its strong anti-androgenic effects on the reproductive and developmental process in male rodents and human. The present study was performed to examine whether prepubertal exposure to DEHP can make any alteration during the maturation of accessory sex organs in male rats. As a result, there was no significant change in body weights, serum T levels and tissue weights except of seminal vesicle and ventral prostate in DEHP-treated animals compared to vehicle-treated ones. The seminal vesicle weights in high-dose group (200 mg/kg) were significantly lower than those from the control group (p<0.05), and ventral prostate weights were significantly lower than those from the control group (p<0.05) in both low-dose (20 mg/kg) and high-dose group. Histological studies revealed that the seminal vesicles from DEHP-treated groups showed reduced areas of mucosal folds. Pseudostratified columnar epithelia were observed in the ventral prostates of DEHP-treated samples while cuboidal epithelia were found in the control group. The transcriptional activities of ER-$\alpha$ in seminal vesicle from high-dose group (p<0.05) were significantly higher than those from the control group, and ER-$\beta$ expression was significantly decreased in low-dose group (p<0.05) compared to the control. In ventral prostate, ER-$\beta$ mRNA levels from low-dose group (p<0.05) were significantly lower than those from the control group, and significantly increased in high-dose group (p<0.01). AR expressions, however, were not significantly different in all experimental groups of both seminal vesicle and ventral prostate. In conclusion, the present study demonstrated that (i) adverse effect (s) of DEHP on sexual maturation during prepubertal period could be limited, (ii) seminal vesicle and prostate gland were sensitive targets to DEHP in prepubertal rats and (iii) the deleterious effects of DEHP might be mediated through ER-associated mechanism.

  • PDF

Method of Reducing Separation Membrane Fouling Using Microbubbles (마이크로버블을 이용한 분리막 파울링 저감방법)

  • Kyung-Hwan Ku;Younghee Kim
    • Clean Technology
    • /
    • v.29 no.1
    • /
    • pp.31-38
    • /
    • 2023
  • Due to water shortages caused by water pollution and climate change, total organic carbon (TOC) standards have been implemented for wastewater discharged from public sewage treatment facilities. Furthermore, there is a growing interest and body of research pertaining to the reuse of sewage treatment water as a secure alternative water resource. The membrane bio-reactor (MBR) method is commonly used for advanced wastewater treatment because it can remove organic and inorganic ions and it does not require or emit any chemicals. However, the MBR process uses a separation membrane (MF), which requires frequent film cleaning due to fouling caused by a high concentration of mixed liquor suspended solid (MLSS). In this study, process improvement and microbubble cleaning efficiency were evaluated to improve the differential pressure, water flow, and MF fouling, which are the biggest disadvantages of operating the MF. The existing MBR method was improved by installing a precipitation tank between the air tank and the MBR tank in which raw water was introduced. Microbubbles were injected into a separation membrane tank into which the supernatant water from the precipitation tank was introduced. The microbubble generator was operated with a 15 day on, 15 day off cycle for 5 months to collect discharged water samples (4L) and measure TOC. As the supernatant water from the precipitation tank flowed into the separation membrane tank, about 95% of the supernatant water MLSS was removed so the MF fouling from biological contamination was prevented. Due to the application of microbubbles to supernatant water from the precipitation tank, the differential pressure of the separation membrane tank decreased by 1.6 to 2.3 times and the water flow increased by 1.4 times. Applying microbubbles increased the TOC removal rate by more than 58%. This study showed that separately operating the air tank and the separation membrane tank can reduce fouling, and suggested that applying additional microbubbles could improve the differential pressure, water flow, and fouling to provide a more efficient advanced treatment method.

Development of control system for complex microbial incubator (복합 미생물 배양기의 제어시스템 개발)

  • Hong-Jik Kim;Won-Bog Lee;Seung-Ho Lee
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.122-126
    • /
    • 2023
  • In this paper, a control system for a complex microbial incubator was proposed. The proposed control system consists of a control unit, a communication unit, a power supply unit, and a control system of the complex microbial incubator. The controller of the complex microbial incubator is designed and manufactured to convert analog signals and digital signals, and control signals of sensors such as displays using LCD panels, water level sensors, temperature sensors, and pH concentration sensors. The water level sensor used is designed and manufactured to enable accurate water level measurement by using the IR laser method with excellent linearity in order to solve the problem that existing water level sensors are difficult to measure due to foreign substances such as bubbles. The temperature sensor is designed and used so that it has high accuracy and no cumulative resistance error by measuring using the thermal resistance principle. The communication unit consists of two LAN ports and one RS-232 port, and is designed and manufactured to transmit signals such as LCD panel, PCT panel, and load cell controller used in the complex microbial incubator to the control unit. The power supply unit is designed and manufactured to supply power by configuring it with three voltage supply terminals such as 24V, 12V and 5V so that the control unit and communication unit can operate smoothly. The control system of the complex microbial incubator uses PLC to control sensor values such as pH concentration sensor, temperature sensor, and water level sensor, and the operation of circulation pump, circulation valve, rotary pump, and inverter load cell used for cultivation. In order to evaluate the performance of the control system of the proposed complex microbial incubator, the result of the experiment conducted by the accredited certification body showed that the range of water level measurement sensitivity was -0.41mm~1.59mm, and the range of change in water temperature was ±0.41℃, which is currently commercially available. It was confirmed that the product operates with better performance than the performance of the products. Therefore, the effectiveness of the control system of the complex microbial incubator proposed in this paper was demonstrated.

Research on Radiation Shielding Film for Replacement of Lead(Pb) through Roll-to-Roll Sputtering Deposition (롤투롤 스퍼터링 증착을 통한 납(Pb) 대체용 방사선 차폐필름 개발)

  • Sung-Hun Kim;Jung-Sup Byun;Young-Bin Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.441-447
    • /
    • 2023
  • Lead(Pb), which is currently mainly used for shielding purposes in the medical radiation, has excellent radiation shielding functions, but is continuously exposed to radiation directly or indirectly due to the harmfulness of lead itself to the human body and the inconvenience caused by its heavy weight. Research on shielding materials that are human-friendly, lightweight, and convenient to use that can block risks and replace lead is continuously being conducted. In this study, based on the commonly used polyethylene terephthalate (PET) film and the fabric material used in actual radiation protective clothing, a multi-layer thin film was realized through sputtering and vacuum deposition of bismuth, tungsten, and tin, which are metal materials that can shield radiation. Thus, a shielding film was produced and its applicability as a radiation shielding material was evaluated. The radiation shielding film was manufactured by establishing the optimized conditions for each shielding material while controlling the applied voltage, roll driving speed, and gas supply amount to manufacture the shielding film. The adhesion between the parent material and the shielding metal thin film was confirmed by Cross-cut 100/100, and the stability of the thin film was confirmed through a hot water test for 1 hour to measure the change of the thin film over time. The shielding performance of the finally realized shielding film was measured by the Korea association for radiation application (KARA), and the test conditions (inverse wide beam, tube voltage 50 kV, half layer 1.828 mmAl) were set to obtain an attenuation ratio of 16.4 (initial value 0.300 mGy/s, measured value 0.018 mGy/s) and damping ratio 4.31 (initial value 0.300 mGy/s, measured value 0.069 mGy/s) were obtained. by securing process efficiency for future commercialization, light and shielding films and fabrics were used to lay the foundation for the application of films to radiation protective clothing or construction materials with shielding functions.

Comparative study of flood detection methodologies using Sentinel-1 satellite imagery (Sentinel-1 위성 영상을 활용한 침수 탐지 기법 방법론 비교 연구)

  • Lee, Sungwoo;Kim, Wanyub;Lee, Seulchan;Jeong, Hagyu;Park, Jongsoo;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.57 no.3
    • /
    • pp.181-193
    • /
    • 2024
  • The increasing atmospheric imbalance caused by climate change leads to an elevation in precipitation, resulting in a heightened frequency of flooding. Consequently, there is a growing need for technology to detect and monitor these occurrences, especially as the frequency of flooding events rises. To minimize flood damage, continuous monitoring is essential, and flood areas can be detected by the Synthetic Aperture Radar (SAR) imagery, which is not affected by climate conditions. The observed data undergoes a preprocessing step, utilizing a median filter to reduce noise. Classification techniques were employed to classify water bodies and non-water bodies, with the aim of evaluating the effectiveness of each method in flood detection. In this study, the Otsu method and Support Vector Machine (SVM) technique were utilized for the classification of water bodies and non-water bodies. The overall performance of the models was assessed using a Confusion Matrix. The suitability of flood detection was evaluated by comparing the Otsu method, an optimal threshold-based classifier, with SVM, a machine learning technique that minimizes misclassifications through training. The Otsu method demonstrated suitability in delineating boundaries between water and non-water bodies but exhibited a higher rate of misclassifications due to the influence of mixed substances. Conversely, the use of SVM resulted in a lower false positive rate and proved less sensitive to mixed substances. Consequently, SVM exhibited higher accuracy under conditions excluding flooding. While the Otsu method showed slightly higher accuracy in flood conditions compared to SVM, the difference in accuracy was less than 5% (Otsu: 0.93, SVM: 0.90). However, in pre-flooding and post-flooding conditions, the accuracy difference was more than 15%, indicating that SVM is more suitable for water body and flood detection (Otsu: 0.77, SVM: 0.92). Based on the findings of this study, it is anticipated that more accurate detection of water bodies and floods could contribute to minimizing flood-related damages and losses.

Effect of Acute Ethanol Intoxication on the Pulmonary Compliance and Surfactant in Rats (급성(急性) Ethyl 알콜 중독(中毒) 흰쥐의 폐용압률(肺容壓率)과 폐포활성물질(肺胞活性物質)의 변화(變化))

  • Lee, Seung-Jung;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.15 no.1
    • /
    • pp.27-36
    • /
    • 1981
  • Relatively little has been done on the metabolic changes of the lung produced by the excessive alcohol ingestion to the point of the acute alcohol intoxication. In the present study, an effort was made to clarify the possible changes of the pulmonary surfactant system by the acute alcohol ingestion. The dynamic pulmonary compliance and the levels of protein and inorganic phosphorus (Pi) of both lung lavage and extract were chosen as the parameters of the pulmonary surfactant activities. The albino rats of both sexes were used, and 1.5 ml of 50% ethanol per 100 g body weight was given by oral intubation, and the experiment was performed at 1, 3, 6, 12, and 24 hours after the alcohol ingestion. The rat was sacrificed by cutting the carotid arteries, and blood sample for the determination of hematocrit(Hct) and the blood alcohol concentration was obtained. Both lungs were completely removed without dammage to the lung tissue, and the pulmonary compliance was measured by the changes of pressure-volume(P-V) curves by inflating or deflating the lung with air. Immediately after the P-V curves were recorded, the lung lavage was obtained by washing the lobes with 15ml of isotonic saline 3 times with a syringe. Next, total lungs were homogenized and filtered to obtain the lung extract. The protein and Pi levels were measured using the lung lavage and extract as the samples, and the lung/body weight ratio(L/B ratio) was also calculated. The results thus obtained were compared with the normal values and summarized as follows. The blood alcohol concentration reached the highest level of $0.71{\pm}0.02\;g\;%$ at 1 hr and gradually decreased until 24 hrs$(0.36{\pm}0.02\;g%)$ after the alcohol ingestion, but all the experimental groups showed significant increase comparing with the normal. The highest Hct value was obtained at 1hr$(64.86{\pm}2.45%)$ and significantly elevated value was continued throughout the experiment. The L/B ratio was significantly lowered from 3hrs until 24hrs after the alcohol ingestion but from 6 th hr on, a generally elevated value was observed with a significant value at 12 hrs and gradual recovery to the normal value at 24 hrs after the alcohol ingestion. The pulmonary compliance at inflation and deflation did not change appreciablly from the normal until 3 hrs after the alcohol ingestion but from 6 th hr on, a generally elevated value was observed with a significant value at 12 hrs and gradual recovery to the normal value at 24 hrs after the alcohol ingestion. The protein level of the lung lavage stowed a significantly increased value of $12.36{\pm}0.35\;mg/gm(3rd hr)$, $12.70{\pm}0.74\;mg/gm(12 th hr)$, and $12.65{\pm}0.88\;mg/gm(24 th hr)$, respectively, comparing with the normal value of $10.65{\pm}0.62\;mg/gm$, and the Pi level also showed a similar tendency of significant increase at 12th hr $(7.65{\pm}0.63\;{\mu}mol/gm)$ and 24 th hr$(6.70{\pm}0.36\;{\mu}mol/gm)$ comparing with the normal value of $5.32{\pm}0.20\;{\mu}mol/gm$. The protein level of the lung extract in the alcohol group was generally similar to the normal value with a slight decrease at 1st and 3 rd hr, tut the Pi level of the lung extract was generally increased in the alcohol group, and a significant increase was observed at 6 th hr$(17.77{\pm}1.54\;{\mu}mol/gm)$, 12 th hr$(13.92{\pm}0.78\;{\mu}mol/gm)$ and 24 th hr$(14.57{\pm}0.53\;{\mu}mol/gm)$ of the alcohol ingestion comparing with the normal value of $10.34{\pm}0.37\;{\mu}mol/gm$. From the above, it may be concluded that the acute alcohol intoxication produces the metabolic changes of the lungs by the increased surfactant activities and elevated pulmonary compliance.

  • PDF

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF