• Title/Summary/Keyword: blood velocity

Search Result 393, Processing Time 0.024 seconds

Acoustic Levitation and Rotation Produced by Ultrasonic Flexural Vibration (초음파 굽힘 진동에 의한 음향 부상 및 회전)

  • Loh, Byoung-Gook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.5
    • /
    • pp.432-438
    • /
    • 2004
  • Acoustic levitation induced by ultrasonic flexural vibration at 28.4 KHz with a vibration amplitude of 10 micrometers is presented. Levitation of multiple objects along the length of the beam in a gap of 8.3 mm which is the half of acoustic wavelength is experimentally demonstrated. Analytical analysis predicts that levitated objects for the gap of half-the wavelength converges to the center of the gap, which is experimentally verified. It is observed that levitated objects with well-balanced mass distribution are set into rotation due to acoustic streaming. For cylinder-shaped Styrofoam with a diameter of 1.8 mm and a length of 3 mm, measured rotational velocity is 2400 revolution per minute. Applications of standing wave field levitation (SWFL) include manipulation of biological cells and blood constituents in biotechnology, and fine powder in material engineering.

Dioscorea Extract (DA-9801) Modulates Markers of Peripheral Neuropathy in Type 2 Diabetic db/db Mice

  • Moon, Eunjung;Lee, Sung Ok;Kang, Tong Ho;Kim, Hye Ju;Choi, Sang Zin;Son, Mi-Won;Kim, Sun Yeou
    • Biomolecules & Therapeutics
    • /
    • v.22 no.5
    • /
    • pp.445-452
    • /
    • 2014
  • The purpose of this study was to investigate the therapeutic effects of DA-9801, an optimized extract of Dioscorea species, on diabetic peripheral neuropathy in a type 2 diabetic animal model. In this study, db/db mice were treated with DA-9801 (30 and 100 mg/kg, daily, p.o.) for 12 weeks. DA-9801 reduced the blood glucose levels and increased the withdrawal latencies in hot plate tests. Moreover, it prevented nerve damage based on increased nerve conduction velocity and ultrastructural changes. Decrease of nerve growth factor (NGF) may have a detrimental effect on diabetic neuropathy. We previously reported NGF regulatory properties of the Dioscorea genus. In this study, DA-9801 induced NGF production in rat primary astrocytes. In addition, it increased NGF levels in the sciatic nerve and the plasma of type 2 diabetic animals. DA-9801 also increased neurite outgrowth and mRNA expression of Tieg1/Klf10, an NGF target gene, in PC12 cells. These results demonstrated the attenuation of diabetic peripheral neuropathy by oral treatment with DA-9801 via NGF regulation. DA-9801 is currently being evaluated in a phase II clinical study.

A Case of Churg-Strauss Syndrome with Diffuse Alveolar Hemorrhage Presenting as Acute Acalculous Cholecystitis (미만성 폐포 출혈을 동반한 급성 담낭염으로 발현한 Churg-Strauss 증후군 1예)

  • Kim, Ji Eun;Kim, Ki Uk;Park, Hye-Kyung;Jeon, Doo Soo;Kim, Yun Sung;Lee, Min Ki;Park, Soon Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.3
    • /
    • pp.225-229
    • /
    • 2009
  • Churg-Strauss syndrome (CSS) is a disorder that is characterized by asthma, hypereosinophilia and systemic vasculitis affecting a number of organs. The manifestations of acute cholecystitis and diffuse alveolar hemorrhage are rarely reported in CSS. A 22-year-old woman with bronchial asthma visited our hospital complaining of right upper quadrant pain with a sudden onset. The abdominal computed tomography (CT) scan revealed gall bladder edema consistent with acute cholecystitis. On the initial evaluation, marked hypereosinophilia was observed in the peripheral blood smear. The nerve conduction velocity measurements and a skin biopsy performed to confirm the organ involvement of disease indicated typical mononeuritis multiplex and necrotizing vasculitis, respectively, which was complicated with CSS. On the 12th hospital day, ground glass opacity and consolidations were newly developed on both lung fields. The bronchoalveolar lavage (BAL) fluid showed increasing bloody return in sequential aliquots that were characteristic of a diffuse alveolar hemorrhage. We report a case of CSS with acute cholecystitis and diffuse alveolar hemorrhage.

Three-Dimensional Digital Subtraction Angiography (디지털 혈관 조영술 영상의 3차원적 해석)

  • 이승지;김희찬
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.1
    • /
    • pp.63-71
    • /
    • 1983
  • A dye-edge tracking algorithm was used to determine the corresponding points in the two images(anterior-posterior and lateral) of the digital subtraction biplane angiography. This correspondence was used to reconstruct three dimensional images of cerebral artery in a dog experiment. The method was tested by comparing the measured image of oblique view with the computed reconstructed image. For the present study, we have developed three new algorithms. The first algorithm is to determine the corresponding dye-edge points using the fact the dye density at the moving edge avows the same changing pattern in the two projection views. This moving pattern of dye-edge density is computed using a matching method of cross-correlation for the two sequential frames' dye density. The second algorithm is for simplified perspective transformation, and the third one is to identify the specific corresponding points on the small vessels. The present method can be applied to compute the blood velocity using the dye-edge displacement and the three- dimensional distance data.

  • PDF

The Effect of Microcurrent Electrical Stimulation on the Articular Cartilage Recovery in Osteoarthritis (비침습식 미세전류자극이 실험적으로 유발된 흰쥐의 골관절염 회복에 미치는 영향)

  • Bang, Hyun-Soo;Kang, Jong-Ho;Cheon, Song-Hee;Kim, Min-Hee;Park, Soo-Jin;Kim, Jin-Sang;Park, Rae-Joon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.2
    • /
    • pp.151-159
    • /
    • 2007
  • Purpose : The purpose of the study was to investigate the effect of cold application on knee joint in rats induced by osteoarthritis. Methods : Osteoarthritis was induced in female Sprague-Dowley rats by injecting into articular cavity of knee joint with 4% Kaolin, 2% carrageenan. Rats were divided randomly into the control and MES applicated group. The Experimental group was applicated MES in rat knee joint for 30 minutes. Results : Recovery of articular cartilage surface and thickness of articular cartilage increased after MES application. And chondrocytes were distributed widely throughout the cartilage matrix. The physical effects of Microcurrent Electrical Stimulation. Decrease in blood flow. Delay of neurotransmitter velocity Decrease in metabolism activity and inhibit the progress of the infection. Decrease in pain and muscle rigidity, inhibition of circulation Conclusion : This study shows that MES application affects articular cartilage recovery in osteoarthritis.

  • PDF

A Study on the Optimal Clothing Weight in an Air Conditioned Office in Summer (여름철 냉방실내의 적정착의량에 관한 연구)

  • Kim Sun Young;Lee Soon Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.9 no.3
    • /
    • pp.45-51
    • /
    • 1985
  • The purpose of this study is to research into the thermal condition and the weight of clothes suitable for the officers engagged in light works in an air-conditioned room in summer. The Major findings are as follows: 1. Thermal conditions of the working environment are $24.5^{\circ}C$ (Dry bulb temp.), $68\%$ (Relative humidity) and 2.6m/sec (Air Velocity). 2. Total clothing weights are 416.6 g/$m^2$ (male) and 340.9 g/$m^2$ (female). Underwear weights are 96.8g/$m^2$ (male) and 85.1g/$m^2$ (female). The latter turned out to be statistically significant in Sexual difference. 3. Means of the thermal sensation are 3.0 (comfortable; male) 2.7 ('Slightly cool' -'Comfortable'; female) and the relationship between clothing weights and thermal sensation proves to be significantly correlated in the case of female. 4. $66.7\%$ of the women and $37.1\%$ of the men feel sensation of coldness at the body's specific area and $79.5\%$ of the women and $54.3\%$ of the men reveals air-conditioning disturbance. 5. As the thermal sensation is close to 'cool-cold', sensation of coldness or air conditioning disturbance are showed up more frequently which is reversely related with weight of under-wear. It is also proved that air conditioning disturbances are influenced by sexual difference in addition to sensation of coldness and thermal sensation. 6. According to the result of experiment, we can have the idea that at condition $X_1$, the drop of limbs' skin temp. is remarkable. At condition $X_2$ skin temp. for distal limbs and mean skin temp. are raised and the falling degree is similar. At condition $X_3$, mean skin temp. and distal skin temp. are remarkably raised, and the falling degree decreases and the beats of pulse rate increase and diastoric blood pressure is lowered.

  • PDF

의료용재료의 최근 개발현황

  • 김영하
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.117-124
    • /
    • 1989
  • The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan`s method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements.

  • PDF

Intraarterial Nimodipine Infusion to Treat Symptomatic Cerebral Vasospasm after Aneurysmal Subarachnoid Hemorrhage

  • Kim, Jong-Hoon;Park, In-Sung;Park, Kyung-Bum;Kang, Dong-Ho;Hwang, Soo-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.3
    • /
    • pp.239-244
    • /
    • 2009
  • Objective : Cerebral vasospasm leading to cerebral ischemic infarction is a major cause of morbidity and mortality in the patients who suffer with aneurysmal subarachnoid hemorrhage. Despite adequate treatment, some patients deteriorate and they develop symptomatic vasospasm. The objective of the present study was to investigate the efficacy and clinical outcome of intraarterial nimodipine infusion on symptomatic vasospasm that is refractory to hemodynamic therapy. Methods : We retrospectively reviewed the procedure reports, the clinical charts and the transcranial doppler, computed tomography and digital subtraction angiography results for the patients who underwent endovascular treatment for symptomatic cerebral vasospasm due to aneurysmal SAH. During the 36 months between Jan. 2005 and Dec. 2007, 19 patients were identified who had undergone a total of 53 procedures. We assessed the difference in the arterial vessel diameter, the blood flow velocity and the clinical outcome before and after these procedures. Results : Vascular dilatation was observed in 42 of 53 procedures. The velocities of the affected vessels before and after procedures were available in 33 of 53 procedures. Twenty-nine procedures exhibited a mean decrease of 84.1 cm/s. We observed clinical improvement and an improved level of consciousness with an improved GCS score after 23 procedures. Conclusion : Based on our results, the use of intraarterial nimodipine is effective and safe in selected cases of vasospasm following aneurysmal SAH. Prospective, randomized studies are needed to confirm these results.

Effect of Number and Condition of Reflection Site on Pulse Wave (반사 지점의 개수와 조건이 맥파에 미치는 영향)

  • Lee, Min-Woo;Jang, Min;Shin, Sang-Hoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.8-13
    • /
    • 2020
  • To develop cardiovascular simulator capable of implementing pulse waves similar to the human body, accurate information about reflection wave is required. However, the conclusion is still not clear and various discussions are underway. In this study, the pulse wave velocity of the tube used in the experiment was first determined by measuring the pressure waves at two points in a single tube system with the experimental device to implement the pulse wave transmission of blood vessels, and the superposition time and characteristics of the reflection wave were confirmed. After that, an air chamber was set at the reflection site, and the effect of the change of air volume on the reflection wave was investigated. Finally, the effect of the number of branches connected to a single tube on the reflection wave was investigated. The superposition time of the reflection wave can be controlled by the air volume of the air chamber, and the magnitude of the reflection wave is influenced by the number of reflection sites that generate the reflection wave. The results of this study may be of practical assistance to simulator researchers who want to implement pulse wave similar to clinical data. It is expected that the more results similar to clinical are provided, the greater the scope of the simulator's contribution to clinical cardiovascular research.

Estimation of Stroke Volume Based on Air Pressure in Air Tube with Pneumatic Pulsatile Ventricular Assist Device (공압식 박동형 심실보조장치에서 공압관 내 공기압에 따른 박출량 추정)

  • Kang, Yu Min;Lee, Jin Hong;Her, Keun;Choi, Seong Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.971-974
    • /
    • 2014
  • A ventricular assist device (VAD) is used for bridge to heart transplantation and heart diseases. Knowing the status of a pneumatic pulsatile VAD when implanting it into the body is important: when the velocity of blood flow through the VAD is slow, a thrombus may occur, and thrombosis can be fatal to a patient. In order to determine the state of a VAD, various sensors need to be implanted. Because this introduces the risk of infection and difficulties with sensor management, we developed a method for estimating the state of a VAD indirectly via the pressure in an air tube that can be measured in vitro. We compared the measured values to in vitro experimental results. The estimated and measured values showed some errors, but the accuracy can be improved by refining the estimation process to minimize the risk of infection.