• Title/Summary/Keyword: blood pressure monitor

Search Result 105, Processing Time 0.026 seconds

Changes of Postprandial Blood Pressure of Elderly in Nursing Homes by Position (시설 거주 노인의 식사 후 체위에 따른 혈압의 변화양상)

  • Son, Jung Tae;Lee, Eunjoo;Park, Ji Hyun
    • 한국노년학
    • /
    • v.32 no.3
    • /
    • pp.689-701
    • /
    • 2012
  • The purposes of this study were to identify the changes of postprandial blood pressure and pulse rates of elderly living in nursing homes by time and position after a meal. Blood pressure and pulse rates of 141 elderly aged over 65 years were measured at before the meal to 90 minutes after the meal by 15 min. interval. Data were analyzed by descriptive statistics, repeated measures of ANOVA, ANCOVA, and t-test using the SPSS program. There were no significant differences in change of systolic blood pressure and pulse rates by time between sitting group and lying group after meal. The biggest drops in systolic pressure in sitting and lying position were occurred at 30 min and 45min respectively after the meal. There were no significant change in pulse rates except for the immediately after meal in lying position. To prevent complications of postprandial blood pressure reduction, nurses should carefully monitor blood pressure of elderly in lying position at least from 30 min. till to 90 min. after the meal.

Evaluation of u-Healthcare Demonstration Project in Sungnam (성남 u-헬스 시범사업의 평가)

  • Lee, Won-Jae;Kim, Hye-Jung
    • Journal of Information Technology Services
    • /
    • v.7 no.2
    • /
    • pp.113-125
    • /
    • 2008
  • To test if the developed ubiquitous health care devices working well and vital information could be collected and monitored systematically through internet and to test if the devices and services could be used further. Kyungwon University, KT Co., Gil Medical Center, LIG Nex1 Co., and Sujeong Health Center conducted an ubiquitous health care demonstration project in Sujeong-Gu, Sungnam, Korea from Mar. 5 to May 16. We developed and applied several medical devices to monitor health of the elderly in their houses through internet. The devices were sphygmomanometer, glucometer, body fat scale, Health Pad, and activity sensor. We distributed the devices to 20 recipients of home care and 7 diabetes patients. After received the devices and were explained how to use them, they used the devices in their houses. The vital signs of the residents were monitored through internet. A nurse monitored and consulted their vital signs in the monitoring center in Kyungwon University during the demonstration period. The consultant called them and consulted on their blood pressure, blood sugar level, and body fat after a few seconds they used the devices as well as provision of recommended contents such as diets and activities through Health Pad. To investigate cognition and satisfaction of the participants for the devices, we surveyed the participants at the end of the demonstration period. For the change in blood pressure, blood sugar level, and activities, we conducted statistical test. After the demonstration period. cognition and satisfaction for the devices and change in blood pressure, blood sugar level, and activities were evaluated. Most of the participants were acknowledged how to use the device and satisfied with the use of the devices. The internet monitoring and services are considered to be promising because most of the participants were satisfied especially because somebody was monitoring their health status. However some weaknesses such as short battery life of the activity sensor, lack of connection of consultations with hospitals, and low understanding on usage of some of the devices need to be complemented.

Development and Estimation of a Wireless Controlled Implantable Electric-stimulator for the Blood Pressure Regulation (혈압조절을 위한 모선 제어되는 체내 이식형 전기 자극기의 개발 및 체외 성능 평가)

  • Kim, Yoo-Seok;Park, Seong-Min;Shim, Eun-Bo;Choi, Seong-Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.395-400
    • /
    • 2010
  • Hypertension is the chronic disease that the 16% of total population are suffering, and it needs to be studied to find alternative treatment because of the tolerance and side effect of medications that may bother some patients. in this paper, we verified practicality of implantable electrical stimulator that can readily change stimulus magnitude and frequency. And this device is possible to stimulate baroreflex or parasympathetic nerve. Therefore we performed in vitro tests and animal experiment for device's operating conditions. This device consist of implantable electrical stimulator and extracorporeal control/monitoring system. Stimulator was designed to make 1Hz~100Hz pulses and it can change continuous or periodic pulse train type. And this device can control stimulator's function and monitor stimulator's status and patients' blood pressure at exterior of body using ZigBee module as wireless telecommunication. We verified that stimulator have error rate under 5% at 50mm depth of organs and, stimulator makes high-efficiency energy with closer position of two electrodes. Also we can confirm the performance of device that decreasing blood pressure and heart rate of a rat by electrical stimulation.

Effect of the respiratory rate on the pulse pressure variation induced by hemorrhage in anesthetized dogs

  • Dalhae, Kim;Won-Gyun, Son;Donghwi, Shin;Jiyoung, Kim;Inhyung, Lee
    • Journal of Veterinary Science
    • /
    • v.23 no.6
    • /
    • pp.68.1-68.8
    • /
    • 2022
  • Background: Studies on anesthetized dogs regarding pulse pressure variation (PPV) are increasing. The influence of respiratory rate (RR) on PPV, in mechanically ventilated dogs, has not been clearly identified. Objectives: This study evaluated the influence of RR on PPV in mechanically ventilated healthy dogs after hemorrhage. Methods: Five healthy adult Beagle dogs were premedicated with intravenous (IV) acepromazine (0.01 mg/kg). Anesthesia was induced with alfaxalone (3 mg/kg IV) and maintained with isoflurane in 100% oxygen. The right dorsal pedal artery was cannulated with a 22-gauge catheter for blood removal, and the left dorsal pedal artery was cannulated and connected to a transducer system for arterial blood pressure monitoring. The PPV was automatically calculated using a multi-parameter monitor and recorded. Hemorrhage was induced by withdrawing 30% of blood (24 mL/kg) over 30 min. Mechanical ventilation was provided with a tidal volume of 10 mL/kg and a 1:2 inspiration-to-expiration ratio at an initial RR of 15 breaths/min (baseline). Thereafter, RR was changed to 20, 30, and 40 breaths/min according to the casting lots, and the PPV was recorded at each RR. After data collection, the blood was transfused at a rate of 10 mL/kg/h, and the PPV was recorded at the baseline ventilator setting. Results: The data of PPV were analyzed using the Friedman test followed by the Wilcoxon signed-rank test (p < 0.05). Hemorrhage significantly increased PPV from 11% to 25% at 15 breaths/min. An increase in RR significantly decreased PPV from 25 (baseline) to 17%, 10%, and 10% at 20, 30, and 40 breaths/min, respectively (all p < 0.05). Conclusions: The PPV is a dynamic parameter that can predict a dog's hemorrhagic condition, but PPV can be decreased in dogs under high RR. Therefore, careful interpretation may be required when using the PPV parameter particularly in the dogs with hyperventilation.

The Effect of EEG And Physiological Changes To Participation in Progressive Relaxation Technique Of The University Archery players (호흡을 통한 신체적 이완이 대학 양궁선수의 뇌파 및 생리적 변인에 미치는 영향)

  • Nam, Sang-Nam;Park, Soo-Woong
    • Journal of Digital Convergence
    • /
    • v.12 no.1
    • /
    • pp.467-473
    • /
    • 2014
  • The purpose of this study is to monitor the physiological changes by measuring EEG, blood pressure, heart rate, etc after applying progressive relaxation technique to university archery players in order to verify the effect of progressive relaxation through respiration, and, ultimately, improve an athlete's archery performance. This study chose 13 female archery athletes. The EEG, blood pressure, and heart rate of the athletes were measured before applying Jacobson's progressive relaxation technique for 12 weeks, during which the EEG, blood pressure, and heart rate were measured 3 times a week after 15 to 20 minutes of training before every measurement. We used the SPSS18.0 program for technical analysis to check the general features of the athletes and carried out the paired t-test to examine the changes made to the EEG, blood pressure, and heart rate of a single test group before and after the experiment. All statistical level of significance was maintained at ${\alpha}=0.5$. The results are as follows. First, after 12 weeks of appliance, between the targets' relative ${\alpha}$ wave and ${\beta}$ wave, the relative ${\alpha}$ wave showed a statistically significant increase while the relative ${\beta}$ wave showed no changes. Second, after 12 weeks of appliance, in terms of blood pressure, the systolic pressure showed no changes while the diastolic pressure showed a statistically significant change. Third, there was no statistically significant change to the heart rate. In conclusion, progressive relaxation through breathing has a positive effect on the archery athletes.

Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents

  • Lee, Chong-Guk;Park, Hyang-Mi;Shin, Hye-Jung;Moon, Jin-Soo;Hong, Young-Mi;Kim, Nam-Soo;Ha, Il-Soo;Chang, Myeong-Jin;Oh, Kyeong-Won
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.11
    • /
    • pp.463-469
    • /
    • 2011
  • Purpose: To validate the Dinamap ProCare 200 blood pressure (BP) monitor against a mercury sphygmomanometer in children 7 to 18 years old in accordance with the 2010 International Protocol of European Society of Hypertension (ESH-IP2) and the British Hypertension Society (BHS) protocol. Methods: Forty-five children were recruited for the study. A validation procedure was performed following the protocol based on the ESH-IP2 and BHS protocols for children and adolescents. Each subject underwent 7 sequential BP measurements alternatively with a mercury sphygmomanometer and the test device by trained nurses. The results were analyzed according to the validation criteria of ESH-IP2. Results: The mean (${\pm}SD$) difference in the absolute BP values between test device and mercury sphygmomanometer readings was $1.85{\pm}1.65$ mmHg for systolic BP (SBP) and $4.41{\pm}3.53$ mmHg for diastolic BP (DBP). These results fulfilled the Association for the Advancement of Medical Instrumentation criterion of a mean${\pm}$SD below $5{\pm}8$ mmHg for both SBP and DBP. The percentages of test device-observer mercury sphygmomanometer BP differences within 5, 10, and 15 mmHg were 96%, 100%, and 100% for SBP, and 69%, 92%, and 100% for DBP, respectively, in the part 1 analysis; both SBP and DBP passed the part 1 criteria. In the part 2 analysis, SBP passed the criteria but DBP failed. Conclusion: Although the Dinamap ProCare 200 BP monitor failed an adapted ESH-IP2, SBP passed. When comparing BP readings measured by oscillometers and mercury sphygmomanometers, one has to consider the differences between them, particularly in DBP, because DBP can be underestimated.

Implementation of the Intelligent System using RFID for HealthCare Self-Diagnosis (RFID를 이용한 헬스케어 자가진단 지능형시스템 구현)

  • Son, Hui-Bae;Kim, Min-Soo;Rhee, Young-Chul
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.1
    • /
    • pp.146-152
    • /
    • 2010
  • In this paper, we implemented the intelligent healthcare system self-diagnosis that can achieve self-diagnosis by measured bio-signal(blood pressure, blood sugar, body fat monitor) after the recognize a user to access using RFID. The implemented healthcare self-diagnosis intelligent system is consist of kiosk structure that is RFID reader, bio-signal measuring instrument(hemadynamometer, glucometer, body fat monitor), computer for a part of database server and printer for print the result of self-diagnosis. It can achieve self-diagnosis of a user after compare and analyze the measured data and information of a user from database. The implemented system can make simple self-diagnosis even if not take a physical examination at hospital and apply to company, school, etc.

Monitoring system of blood pressure change according to PTT based posture (PTT기반 자세에 따른 혈압변화 모니터링 시스템)

  • Kim, Mi-Seong;Noh, Yun-Hong;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.534-535
    • /
    • 2017
  • With the economic growth, the quality of life of the individual is improving and interest in health is increasing. However, it is not easy for self-care for the modern people who are busy and the elderly who are uncomfortable. The purpose of this study was to develop a healthcare system that can more easily monitor the health condition of the patients. The ECG and pulse wave including the important health information that can be conveniently measured by the general public can be measured and the PTT and to monitor the health status of the circulatory system. To evaluate the performance of the implemented system, we measured PTT according to posture change and evaluated the possibility of monitoring arterial blood flow during daily life.

  • PDF

Design of Head Blood Pressure(HBP) Measurement System and Correlativity Extraction of Blood Pressure(BP) and HBP (두부혈압 측정 시스템의 설계 및 두부혈압과 상완혈압과의 상관성 추출)

  • 이용흠;정석준;장근중;정동영
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.381-389
    • /
    • 2003
  • Various adult diseases (cerebral apoplexy, athymiait, etc.) result from hypertension, blood circulation disturbance and increment of HBP. In early diagnosis of these diseases, MRI, X-ray and PET have been used rather aim for treatment than for a prevention of disease. Since. cerebral apoplexy and athymiait could appear to the regular/irregular persons, it is very important to measure HBP which has connection with cerebral blood flow state. HBP has more diagnosis elements than that of BP. So, we can diagnose accurate hypertension by measuring of HBP. But, existing sphygmomanometers and automatic BP monitors can not measure HBP, and can not execute complex function(measuring of BP/HBP, blood flow improvement). Purpose of this paper is to develop a system and algorithm which can measure BP/HBP for accurate diagnosis. Also, we extracted diagnosis factors by correlativity analysis of BP/HBP. Maximum pressure of HBP corresponds to 62% that of BP, Minimum pressure of HBP corresponds to 46% that of BP. Therefore, we developed the multi-function automatic blood pressure monitor which can measure BP/HBP and improve cerebral blood flow state.

Pressure Regulation System for Optimal Operation of the Pneumatic VAD with Bellows-Type Closed Pneumatic Circuit (벨로우즈 방식의 폐회로를 가진 공압식 심실 보조장치의 최적 작동을 위한 압력 조절 시스템)

  • Kim, Bum-Soo;Lee, Jung-Joo;Nam, Kyung-Won;Jeong, Gi-Seok;Ahn, Chi-Bum;Sun, Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.569-576
    • /
    • 2007
  • Ventricular Assist Device(VAD) has switched its goal from a short-tenn use for bridge-to-transplantation to a long-tenn use for destination therapy, With this goal, the importance of long-tenn reliability gets more interests and importances, H-VAD is an portable extracorporeal biventricular assist device, and adopts an electro-pneumatic driving mechanism. The pneumatic pressure to pump out blood is generated with compression of bellows, and is transmitted in a closed pneumatic circuit through a pneumatic line. The existing pneumatic VAD adopts a air compressor which can generate stable pressures but has defects such as a noise and a size problem. Thus, it is not suitable for being used as a portable device, These problems are covered with adopting a closed pneumatic circuit mechanism with a bellows which has a small size and small noise generation, but it has defects that improper pneumatic setting causes a failure of adequate flow generation. In this study, the pneumatic pressure regulation system is developed to cover these defects of a bellows-type pneumatic VAD. The optimal pneumatic pressure conditions according to various afterload conditions for an optimal flow rate were investigated and the afterload estimation algorithm was developed, The final pneumatic regulation system estimates a current afterload and regulate the pneumatic pressure to the optimal point at a given afterload condition. The afterload estimation algorithm showed a sufficient performance that the standard deviation of error is 8.8 mmHg, The pneumatic pressure regulation system showed a sufficient performance that the flow rate was stably governed to various afterload conditions. In a further study, if a additional sensor such as ultrasonic sensor is developed to monitor the direct movement of diaphragm in a blood pump part, the reliability would be greatly increased. Moreover, if the afterload estimation algorithm gets more accuracy, it would be also helpful to monitor the hemodynamic condition of patients.