• 제목/요약/키워드: blockage

검색결과 551건 처리시간 0.027초

CFD analysis of the flow blockage in a rectangular fuel assembly of the IAEA 10 MW MTR research reactor

  • Xia, Shuang;Zhou, Xuhua;Hu, Gaojie;Cao, Xiaxin
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.2847-2858
    • /
    • 2021
  • When a nuclear reactor with rectangular fuel assemblies runs for a long time, impurities and debris may be taken into coolant channels, which may cause flow blockage, and the blocked fuel assemblies might be destroyed. Therefore, the purpose of this study is to perform a thermal-hydraulic analysis of a rectangular fuel assembly by STAR-CCM+, under the condition of one subchannel with 80% blockage ratio. A rectangular fuel assembly of the International Atomic Energy Agency (IAEA) 10 MW material test reactor (MTR) is chosen. In view of the gasket material taken into the coolant channel is close to the single side of the coolant channel, in the flow blockage accident of the Oak Ridge Research Reactor (ORRR), a new blockage category called single side blockage is attempted. The blockage positions include inlet, middle and outlet, and the blockage is set as a cuboid. It is found by simulations that the blockage redistributes the mass flow rate, and large vortices appear locally. The peak temperature of the cladding is maximum, when the blockage is located at the single side of the coolant channel inlet, and no boiling occurs in all blockage cases. Moreover, as the height of the blockage increases, the damage caused by the blockage increases slightly.

소형 수직축 풍력발전기 풍동실험시 폐쇄율의 영향 (Effect of Blockage Ratio on Wind Tunnel Testing of Small Vertical-Axis Wind Turbines)

  • 정회갑;이승호;권순덕
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.98-106
    • /
    • 2014
  • The effect of blockage ratio on wind tunnel testing of small vertical-axis wind turbine has been investigated in this study. Height and rotor diameter of the three blades Darrieus vertical axis wind turbine used in present test were 0.4m and 0.35m respectively. We measured the wind speeds and power coefficient at three different wind tunnels where blockage ratio were 3.5%, 13.4% and 24.7% respectively. The test results show that the measured powers have been strongly influenced by blockage ratio, generally increased as the blockage ratio increases. The maximum power at higher blockage ratio has been obtained at relatively high tip speed ratio compared with that at low blockage ratio. The measured power coefficients under high blockage ratio can be improved from proper correction using the simple correction equation based on blockage factor. In present study, the correction error for power coefficient can be less than 5%, however correction effectiveness reveals relatively poor at high blockage ratio and low wind speed.

액체금속원자로 핵연료집합체의 내부 유로폐쇄 열수력 해석 (Thermal-Hydraulic Analysis of Internal Flow Blockage within Fuel Assembly of Nuclear Liquid-Metal Fast Reactor)

  • 권영민;한도희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.47-50
    • /
    • 2002
  • The numerical simulation of a 271-rod fuel assembly of nuclear Liquid-Metal Fast Reactor (LMFR) with an infernal blockage has been carried out. Internal blockage within a subassembly is addressed in the safety assessment because it potentially has very serious consequences for the reactor as a whole. Three dimensional calculations were performed using the SABRE4 computer code for the range of blockage positions and sizes to investigate the seriousness and detectability of the internal blockage. The magnitude and location of the peak temperatures together with the temperature distribution at the subassembly exit were calculated in order to look at the potential for damage within the subassembly, and the possibility of blockage detection. The analysis result shows that the 6-subchannel blockage causes large temperature rise within a assembly with practically no change in mixed mean temperature at the assembly exit.

  • PDF

Wind tunnel blockage effects on aerodynamic behavior of bluff body

  • Choi, Chang-Koon;Kwon, Dae-Kun
    • Wind and Structures
    • /
    • 제1권4호
    • /
    • pp.351-364
    • /
    • 1998
  • In wind tunnel experiments, the blockage effect is a very important factor which affects the test results significantly. A number of investigations into this problem, especially on the blockage correction of drag coefficient, have been carried out in the past. However, only a limited number of works have been reported on the wind tunnel blockage effect on wind-induced vibration although it is considered to be fairly important. This paper discusses the aerodynamic characteristics of the square model and square model with corner cut based on a series of the wind tunnel tests with various blockage ratios and angles of attack. From the test results, the aerodynamic behavior of square models with up to 10% blockage ratio are almost the same and square models with up to 10% blockage ratio can be tested as a group which behaves similarly.

Study on the influence of flow blockage in severe accident scenario of CAP1400 reactor

  • Pengcheng Gao;Bin Zhang ;Jishen Li ;Fan Miao ;Shaowei Tang ;Sheng Cao;Hao Yang ;Jianqiang Shan
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.999-1008
    • /
    • 2023
  • Deformed fuel rods can cause a partial blockage of the flow area in a subchannel. Such flow blockage will influence the core coolant flow and further the core heat transfer during the reflooding phase and subsequent severe accidents. Nevertheless, most of the system analysis codes simulate the accident process based on the assumed flow blockage ratio, resulting in inconsistencies between simulated results and actual conditions. This paper aims to study the influence of flow blockage in severe accident scenario of the CAP1400 reactor. First, the flow blockage model of ISAA code is improved based on the FRTMB module. Then, the ISAA-FRTMB coupling system is adopted to model and calculate the QUENCH-LOCA-0 experiment. The correctness and validity of the flow blockage model are verified by comparing the peak cladding temperature. Finally, the DVI Line-SBLOCA accident is induced to analyze the influence of flow blockage on subsequent CAP1400 reactor core heat transfer and core degradation. From the results of the DVI Line-SBLOCA accident analysis, it can be concluded that the blockage ratio is in the range of 40%-60%, and the position of severe blockage is the same as that of cladding rupture. The blockage reduces the circulation area of the core coolant, which in turn impacts the heat exchange between the core and the coolant, leading to the early failure and collapse of some core assemblies and accelerating the core degradation process.

ESTABLISHMENT OF A NEURAL NETWORK MODEL FOR DETECTING A PARTIAL FLOW BLOCKAGE IN AN ASSEMBLY OF A LIQUID METAL REACTOR

  • Seong, Seung-Hwan;Jeong, Hae-Yong;Hur, Seop;Kim, Seong-O
    • Nuclear Engineering and Technology
    • /
    • 제39권1호
    • /
    • pp.43-50
    • /
    • 2007
  • A partial flow blockage in an assembly of a liquid metal reactor could result in a cooling deficiency of the core. To develop a partial blockage detection system, we have studied the changes of the temperature fluctuation characteristics in the upper plenum according to changes of the t10w blockage conditions in an assembly. We analyzed the temperature fluctuation in the upper plenum with the Large Eddy Simulation (LES) turbulence model in the CFX code and evaluated its statistical parameters. Based on the results of the statistical analyses, we developed a neural network model for detecting a partial flow blockage in an assembly. The neural network model can retrieve the size and the location of a flow blockage in an assembly from a change of the root mean square, the standard deviation, and the skewness in the temperature fluctuation data. The neural network model was found to be a possible alternative by which to identify a flow blockage in an assembly of a liquid metal reactor through learning and validating various flow blockage conditions.

Large eddy simulation of blockage effects in the assessment of wind effects on tall buildings

  • Gao, Yang;Gu, Ming;Quan, Yong;Feng, Chengdong
    • Wind and Structures
    • /
    • 제30권6호
    • /
    • pp.597-616
    • /
    • 2020
  • The blockage effect on the aerodynamic characteristics of tall buildings is a fundamental issue in wind tunnel test but has rarely been addressed. To evaluate the blockage effects on the aerodynamic forces on a square tall building and flow field peripherally, large eddy simulations (LES) were performed on a 3D square cylinder with an aspect ratio of 6:1 under the uniform smooth inflow and turbulent atmospheric boundary layer (ABL) inflow generated by the narrowband synthesis random flow generator (NSRFG). First, a basic case at a blockage ratio (BR) of 0.8% was conducted to validate the adopted numerical methodology. Subsequently, simulations were systematically performed at 6 different BRs. The simulation results were compared in detail to illustrate the differences induced by the blockage, and the mechanism of the blockage effects under turbulent inflow was emphatically analysed. The results reveal that the pressure coefficients, the aerodynamic forces, and the Strouhal number increase monotonically with BRs. Additionally, the increase of BR leads to more coherence of the turbulent structures and the higher intensity of the vortices in the vicinity of the building. Moreover, the blockage effects on the aerodynamic forces and flow field are more significant under smooth inflow than those under turbulent inflow.

폐쇄형 풍동 시험부내의 항공기 실속 흐름에 대한 Blockage 보정 기법 연구 (Blockage Correction Method for Separated Flows over an Aircraft in a Closed Test-Section Wind Tunnel)

  • 강승희;권오준;안승기
    • 한국항공우주학회지
    • /
    • 제33권8호
    • /
    • pp.42-49
    • /
    • 2005
  • 아음속풍동 폐쇄형 시험부의 벽면효과 보정을 위한 새로운 blockage 보정 기법을 개발하였다. 개발된 보정 기법은 실속항력계수와 separation blockage의 비선형 관계를 이용하여 선형 양력곡선 기울기 영역에서 후실속 영역까지 실시간으로 보정이 가능하게 하였다. 본 연구에서 제시한 방법은 bluff body 시험 결과를 사용하는 고전적 방법과 벽면압력측정 방법과 비교하여 그 타당성을 검증하였다. 그 결과 본 연구에서 제시한 보정 방법은 실속 및 후실속 영역에서 bluff body 방법보다 우수한 보정 결과를 보이며 벽면압력측정 방법과 같은 정확도로 보정됨을 확인할 수 있었다.

차기 군 위성통신체계 환경에서 이동형 위성단말의 채널 blockage 극복을 위한 확산기반 협업통신 기법의 성능 분석 (Performance Analysis of Cooperative Communication with Spread Spectrum to Overcome Channel Blockage for On-The-Move Terminal in Next Generation Satellite Communication Systems)

  • 박형원;이호섭;윤원식
    • 한국통신학회논문지
    • /
    • 제39C권9호
    • /
    • pp.757-766
    • /
    • 2014
  • 본 논문에서는 차기 군 위성통신체계 환경에서 OTM(On-The-Move) 위성단말의 채널 blockage 신호 손실 보상을 위한 협업통신 기법을 제안하였다. 제안하는 협업기법은 인접 OTM 위성단말과 지상 무전기 체계를 통해 데이터를 공유하고 직교확산코드를 이용하여 대역확산 후 동시에 전송한다. 중첩되어 전송된 확산열은 EGC(Equal Gain Combining) 방식으로 결합한다. 성능 분석을 위해 OTM 위성단말의 blockage 채널을 2-state Markov chain으로 모델링하였으며, 이를 기반으로 협업단말들의 blockage 채널 상태에 따른 비트오류율을 도출하였다. 성능분석 결과 채널 조건이 더 나은 인접 OTM 위성단말의 협업으로 비트오류율 성능이 향상됨을 확인할 수 있었다. 특히 blockage 확률이 높을수록 협업을 통해 더욱 우수한 성능을 확인할 수 있었다. 그러나 서로 다른 지연을 갖는 확산 열 간 중첩으로 인해 협업단말 수 증가 시 다중접속간섭으로 인한 성능상의 제약이 있음을 확인하였다.

차폐유형과 차폐도를 달리한 패럴랙스(Parallax) 공간의 시각 선호도 (An Analysis of the Visual Preference on Parallax Space by Blockage Pattern and Ratio)

  • 노재현
    • 한국조경학회지
    • /
    • 제35권2호통권121호
    • /
    • pp.55-63
    • /
    • 2007
  • The purpose of this study is to create a planting design for progressive realization. For this, visual preferences as measured via questionnaire were evaluated by the Scenic Beauty Estimation(SBE) and paired comparison methods. The results can be summarized as follows. Through photo observation, the average visual blockage ratio was 38% and the range of degree of the visual blockage ratio was $30{\sim}50%$. The sketch simulation and filtered pattern received the highest preference score and fumed out to be the most practical pattern out of all the patterns evaluated. Also, in the sketch simulation, the high preference values were observed for a distance of 9 to 12m from the view point to the blockage tree with a D/H ratio of 2. The preference score significantly decreased with the increase of the visual blockage ratio having a turning point at $30{\sim}35%$ of the visual blockage ratio, even though the distance parameters were more important than the visual blockage ratio in the scores. An outstanding view must be handled properly to be preserved or accentuated. Framed, open, enclosed, screened or filtered pattern views should be completely revealed only from their best vantage point, not given away at first glimpse. It this sense, parallax spatial beauty with trees could be improved through the visual aspects of plan arrangements and seems to be an effective design technique for landscape planning and planting design.