• Title/Summary/Keyword: block segment

Search Result 108, Processing Time 0.022 seconds

An Adaptation System based on Personalized Web Content Items for Mobile Devices

  • Kim, Su-Do;Park, Man-Gon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.3 no.6
    • /
    • pp.628-646
    • /
    • 2009
  • Users want to browse and search various web contents with mobile devices which can be used anywhere and anytime without limitations, in the same manner as desktop. But mobile devices have limited resources compared to desktop in terms of computing performance, network bandwidth, screen size for full browsing, and etc, so there are many difficulties in providing support for mobile devices to fully use desktop-based web contents. Recently, mobile network bandwidth has been greatly improved, however, since mobile devices cannot provide the same environment as desktop, users still feel inconvenienced. To provide web contents optimized for each user device, there have been studies about analyzing code to extract blocks for adaptation to a mobile environment. But since web contents are divided into several items such as menu, login, news, shopping, etc, if the block dividing basis is limited only to code or segment size, it will be difficult for users to recognize and find the items they need. Also it is necessary to resolve interface issues, which are the biggest inconvenience for users browsing in a mobile environment. In this paper, we suggest a personalized adaptation system that extracts item blocks from desktop-based web contents based on user interests, layers them, and adapts them for users so they can see preferred contents first.

A Study on the Segmentation for Adaptation of Web Contents in Smart Learning Environment (스마트 학습 환경에서 웹 콘텐츠 적응을 위한 부분화에 관한 연구)

  • Seo, Jin Ho;Kim, Myong Hee;Park, Man-Gon
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.325-333
    • /
    • 2016
  • The development of smart technology has brought the conversion of closed traditional e-learning contents into open flexible smart learning contents consisting of learner-centered modules, without the constraints of time and space by use of smart devices from the uniformed and passive classroom between teachers and learners. It has been demanded an open, personalized and customized teaching and learning contents of smart education and training systems according to wide supply of various smart devices. In this paper, we discuss about the status of the smart teaching and learning systems and analyze the characteristics and structure of the web contents for smart education and training systems by use of smart devices. And we propose a method how to block web contents, to extract them, and adapt personalized segments of web contents by adaptive algorithm into smart learning devices. We extract blocks from the web contents based on the smart device information and the preference information of the learners from existing web contents without the hassle of learners environment. After specifying a block priority from the extracted web contents by the adaptive segment algorithm, it can be displayed directly to the screen to fit the individual learning progress of the learners.

Facial Palsy Accompanied with Herpes Zoster on the Cervical Dermatome -A case report- (상 경부 대상포진에 병발한 안면신경 마비 -증례 보고-)

  • Yoon, Duck-Mi;Kim, Chang-Ho;Lee, Youn-Woo;Nam, Yong-Tack
    • The Korean Journal of Pain
    • /
    • v.10 no.1
    • /
    • pp.97-100
    • /
    • 1997
  • We treated a 56 year old male ailing of painful herpetic eruption on his 2nd, 3rd and 4th left cervical spinal segment. On the 18th day, patient also suffered an abrupt left facial palsy, accompanied with ongoing postherpetic neuralgia even though the skin eruption had been cured. This patient visited our pain clinic on his 46th day of illness and was teated with continuous cervical epidural block for 9 days, and stellate ganglion block plus oral analgesics and antidepressant for 12 days. The combination of treatments resulted in marked improvement of facial palsy and postherpetic neuralgia. A possible explanation of facial palsy accompanied with herpes zoster on cervical spinal segment could be related to Hunt's hypothesis that geniculate ganglion forms a chain connecting the high cervical ganglion below. Another possibility may be related to a compression injury of the facial nerve by long-term severe edema on the soft tissue of the face, the periauricular area and parotid gland around the facial nerve, and edema on the facial nerve itself emerging out from the cranium.

  • PDF

A Polymeric Micellar Carrier for the Solubilization of Biphenyl Dimethyl Dicarboxylate

  • Chi, Sang-Cheol;Yeom, Dae-Il;Kim, Sung-Chul;Park, Eun-Seok
    • Archives of Pharmacal Research
    • /
    • v.26 no.2
    • /
    • pp.173-181
    • /
    • 2003
  • A polymeric micelle drug delivery system was developed to enhance the solubility of poorly-water soluble drug, biphenyl dimethyl dicarboxylate, DDB. The block copolymers consisting of poly(D,L-lactide) (PLA) as the hydrophobic segment and methoxy poly(ethylene glycol) (mPEG) as the hydrophilic segment were synthesized and characterized by NMR, DSC and MALDI-TOF mass spectroscopy. The size of the polymeric micelles measured by dynamic light scattering showed a narrow monodisperse size distribution with the average diameter less than 50 nm. The MW of mPEG-PLA, 3000 (MW of mPEG, 2 K; MW of PLA, 1K), and the presence of hydrophilic and hydrophobic segments on the polymeric micelles were confirmed by MALDI-TOF mass spectroscopy and NMR, respectively. Polymeric micelle solutions of DDB were prepared by three different methods, i.e. the matrix method, emulsion method and dialysis method. In the matrix method, DDB solubility was reached to 13.29 mg/mL. The mPEG-PLA 2K-1K micelle system was compared with the poloxamer 407 micelle system for their critical micelle concentration, micelle size, solubilizing capacity, stability in dilution and physical state. DDB loaded-polymeric micelles prepared by the matrix method showed a significantly increased aqueous solubility (>5000 fold over intrinsic solubility) and were found to be superior to the poloxamer 407 micelles as a drug carrier.

A Design of a Register Insertion Backbone Ring Network (레이스터 인서션 Backbone 링 네트워크에 관한 연구)

  • 강철신
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.8
    • /
    • pp.796-804
    • /
    • 1992
  • This paper presents a design of a backbone network which uses a rigister-Insertion ring structure, The introduction of a high speed register in sertton backbone ring enables high performance inter-network 4ommunicatlons In a simple and modular structure at low cost and Its concurrent communications.. Two or more bridge nodes can be used to construct a register Insertion backbone ring network. The high bandwidth of the backbone ring sup ports heavy traffic for Inter-segment Eornrnunicatlons. The bridge node does both local address filtering to block data entering the ring and remote address filtering to block data entering the local LAN segment . Title local address greatly reduces the rate on the backbone ring and the remote address filterlng greatly reduces the traffic rate on each LAN segment. An feature makes the network the network reconflguratlon simpler and transparent to users. A throughput analysis Is used to deterrune the bandwidth of the backbone rlr)g transmission medium.

  • PDF

Separation of VOCs from nitrogen stream using segmented urethane block copolymer membranes with different soft segments

  • Lee, Young-Moo;Park, Ho-Bum
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.23-26
    • /
    • 1999
  • Urethane block copolymers, containing soft segments such as polydimethylsiloxane (PDMS), polytertramethylene glycol(PTMG) and PEO-PPO-PEO (Poloxamer) block copolymer, were synthesized and examined for th vapor- phase separation of toluene from nitrogen stream by using vapor permeation equipment. Generally permeabilities of PTMG and PDMS based urethane membranes were higher than those of Poloxamer based urethane membranes. Organic vapor permeability in the PDMS and PTMG soft segment urethane membranes were greater than those measured in the Poloxamer films, due to more polymer swelling. The membranes performed best with toluene, with toluene/dry N2 seletivities ranging from 120~200 and permeablilities as high as 23$\times$10-9 mol/m2sPa for saturated toluene feeds at 23$^{\circ}C$.

  • PDF

Comparison of Multilevel with Single Level Injection during Lumbar Sympathetic Ganglion Block: Efficacy of Sympatholysis and Incidence of Psoas Muscle Injection

  • Hong, Ji-Hee;Oh, Min-Ju
    • The Korean Journal of Pain
    • /
    • v.23 no.2
    • /
    • pp.131-136
    • /
    • 2010
  • Background: We prospectively evaluated the incidence and possible factors causing intramuscular injection during lumbar sympathetic ganglion block and compared the multiple needle technique to the single technique to obtain a profound and complete block effect. Methods: Among 83 patients, 58 patients (group A, n = 27, multiple needle technique and group B, n = 31, single needle technique) were reevaluated for the changes of skin temperature (Ts) and mean segment of longitudinal contrast spread. After injecting the contrast agent, the incidence of psoas muscle injection and the change of Ts was compared between two groups. Results: The incidence of psoas muscle injection was 21.3% (46/216) and it was associated with the level of injection (L2) significantly (${\chi}_2$ = 14.773, P = 0.001). $DT^{post}$ (postblock temperature difference between ipsilateral and contralateral great toe, $4.6{\pm}2.8^{\circ}C$, $1.8{\pm}1.6^{\circ}C$, P < 0.001 for group A and B) and $DT^{net}$ ($DT^{post}$ - $DT^{pre}$, $3.9{\pm}2.7^{\circ}C$, $1.5{\pm}1.5^{\circ}C$, P < 0.001 for group A and B) was significantly higher in group A. The mean segment of longitudinal contrast spread was $8.1{\pm}0.9$ for group A and $3.2{\pm}1.6$ for group B (P < 0.001). Conclusions: The LSGB at the L2 level showed the lowest incidence of psoas muscle injection of contrast. Multiple needle approach showed more significant increase of $DT^{net}$ and $DT^{post}$.

Deep Learning based Skin Lesion Segmentation Using Transformer Block and Edge Decoder (트랜스포머 블록과 윤곽선 디코더를 활용한 딥러닝 기반의 피부 병변 분할 방법)

  • Kim, Ji Hoon;Park, Kyung Ri;Kim, Hae Moon;Moon, Young Shik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.4
    • /
    • pp.533-540
    • /
    • 2022
  • Specialists diagnose skin cancer using a dermatoscopy to detect skin cancer as early as possible, but it is difficult to determine accurate skin lesions because skin lesions have various shapes. Recently, the skin lesion segmentation method using deep learning, which has shown high performance, has a problem in segmenting skin lesions because the boundary between healthy skin and skin lesions is not clear. To solve these issues, the proposed method constructs a transformer block to effectively segment the skin lesion, and constructs an edge decoder for each layer of the network to segment the skin lesion in detail. Experiment results have shown that the proposed method achieves a performance improvement of 0.041 ~ 0.071 for Dic Coefficient and 0.062 ~ 0.112 for Jaccard Index, compared with the previous method.

Review of GPS and Galileo Integrity Assurance Procedure (GPS와 Galileo의 무결성 보장 방법 조사)

  • Namkyu Woo;Gihun Nam;Heonho Choi;Jiyun Lee
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.13 no.1
    • /
    • pp.53-61
    • /
    • 2024
  • Global Navigation Satellite Systems are expected to meet system-defined integrity requirements when users utilize the system for safety critical applications. While the guaranteed integrity performance of GPS and Galileo is publicly available, their integrity assurance procedure and related methodology have not been released to the public in an official document format. This paper summarizes the integrity assurance procedures of Global Positioning System (GPS) and Galileo, which were utilized during their system development, through a literature survey of their integrity assurance methodology. GPS Block II assures system integrity using the following methods: continuous performance monitoring and maintenance on Space Segment (SS) and Control Segment (CS), through a cause and effect analysis of anomalies and a failure analysis. In GPS Block III, to achieve more stringent integrity performance, safety requirements are integrated into the system design and development from its starting phase to the final phase. Galileo's integrity performance is provided in the Integrity Support Message (ISM) format, as Galileo utilizes a Dual Frequency Multi Constellation (DFMC) Satellite Based Augmentation System (SBAS) and Advanced Receiver Autonomous Integrity Monitoring (ARAIM) to serve safety critical applications. The integrity performance of Galileo is ensured by using a methodology similar to GPS Block II (i.e. continuous performance monitoring and maintenance on the system). The integrity assurance procedures reviewed in this paper can be utilized for a new satellite navigation system that will be developed in the near future.