• Title/Summary/Keyword: blinking

Search Result 120, Processing Time 0.026 seconds

Highly Efficient, Flexible Thin Film Nanogenerator

  • Lee, Geon-Jae
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.10.1-10.1
    • /
    • 2011
  • Energy harvesting technologies converting external sources (such as thermal energy, vibration and mechanical energy from the nature sources of wind, waves or animal movements) into electrical energy is recently a highly demanding issue in the materials science community for making sustainable green environments. In particular, fabrication of usable nanogenerator attract the attention of many researchers because it can scavenge even the biomechanical energy inside the human body (such as heart beat, blood flow, muscle stretching, or eye blinking) by converging harvesting technology with implantable bio-devices. Herein, we describe procedure suitable for generating and printing a lead-free microstructured $BaTiO_3$ thin film nanogenerator on plastic substrates to overcome limitations appeared in conventional flexible ferroelectric devices. Flexible $BaTiO_3$ thin film nanogenerator was fabricated and the piezoelectric properties and mechanically stability of ferroelectric devices were characterized. From the results, we demonstrate the highly efficient and stable performance of $BaTiO_3$ thin film nanogenerator and the integration of bio-eco-compatible ferroelectric materials may enable innovative opportunities for artificial skin and energy harvesting system.

  • PDF

Clinical Observation on 3 Cases of Dry Eye Syndrome (안구 건조증 환자의 치험 3례)

  • Choi, Eun-Hee;Jeon, Ju-Hyun;Kim, Young-Il
    • Journal of Acupuncture Research
    • /
    • v.24 no.4
    • /
    • pp.237-245
    • /
    • 2007
  • Objective : The Dry Eye Syndrome is characterized by reduction of the stability of the tearfilm and a set of alterations of the eye surface which could relate to tear quality, normal makeup of tearfilm and alterations in blinking or regular closing of eyelids. We treated 3 patients who was suffering with severe Dry Eye Syndrome and assessed the effectiveness of Oriental Medicine in the treatment of Dry Eye Syndrome. Methods : The patients were treated by acupunture, Gi Guk Yang Hyeol-decoction(Qijuyangxie-decoction). The improvement of the symptom was judged the subjective symptoms by the change of Ocular Surface Disease Index. Result : We observed in 2 cases of the patient significant decrease in the frequency of subjective symptoms, 1 case was not treated. Conclusion: The Oriental Medicine had effective results in Dry Eye syndrome. We need to have more observation and examination of Dry Eye syndrome.

  • PDF

A clinical study of Tic-disorder child with insomnia (불면(不眠)을 동반(同伴)한 틱장애 환아(患兒) 1례(例)에 대한 증례보고(證例報告))

  • Kim, Yun-Hee;Yoon, Ji-Yeon
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.18 no.2
    • /
    • pp.251-261
    • /
    • 2004
  • Objective : The purpose of this study is to report a Tic-disorder child with insomnia. Methods : The patient suffered from Tic-disorder and insomnia and presenting symptom of Tic-disorder was eye blinking. We estimated by Yale Global Tic Severity Scale (YGTSS) and treated him with Yangsintangkamibang, acupuncture, auriculo-acupuncture and hand acupuncture. Result : After this treatment, symptoms of Tic-disorder and insomnia disappeared and The patient was emotionally stable. Conclusion : We had good effects in oriental medical treatments on Tic-disorder. And so this study requires further studies about Tic-disorders.

  • PDF

Initialization Problem of Indoor Mobile Robots with Artificial Stars (인공 별을 이용한 실내주행로봇의 초기화 문제)

  • Bang, Sung-Kee;Kim, Jin-Oh
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.8
    • /
    • pp.804-809
    • /
    • 2007
  • Initialization problem is defined for indoor mobile robot as a whole process from arrival to normal operation in a new environment. The unstructured environment make the process much more difficult compared to industrial robot in structured environments. We propose a simple and efficient initialization process based on artificial stars on ceiling. Important task points and paths connecting task points are defined based on the corresponding artificial stars. This approach can be used for all kinds of indoor mobile robots with landmarks used for indoor localization.

Eye Gaze toy Human Computer Interaction (눈동자의 움직임을 이용한 휴먼 컴퓨터 인터랙션)

  • 권기문;이정준;박강령;김재희
    • Proceedings of the IEEK Conference
    • /
    • 2003.11b
    • /
    • pp.83-86
    • /
    • 2003
  • This paper suggests user's interface with computer by means of detecting gaze under HMD, head mounted display, environment. System is derived as follows; firstly, calibrate a camera in HMD, which determines geometrical relationship between monitor and captured image. Second, detect the center of pupil using algorithm of the center of mass and represent a gazing position on the computer screen. If user blinks or stares at a certain position for a while, message is sent to computer. Experimental results show the center of mass is robust against glint effects, and detecting error was 7.1%. and 4.85% in vertical and horizontal direction, respectively. To adjust detailed movement of a mouse takes 0.8 sec more. The 98% of blinking is detected successfully and 94% of clicking detection is resulted.

  • PDF

LED신호등의 원형 배열을 이용한 새로운 신호 체계 설계구현

  • Park, Yong-Man;Kwon, Jong-Won;Odgere, Odgere;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.348-350
    • /
    • 2006
  • Currently the indication method of the traffic signal light which is established in our country displays each "red, yellow, green" using the brightness LED signal light. In this paper, one LED circular arrangement replaces the Current indication method of the traffic signal light using two color LED. Also the blinking signal function of present time uses the MCU of AVR series and it is embodied with magnification and abridgment of the circular arrangement for recognizing easily far away. The signal light indication method which is proposed will be able to substitute the signal light of 3 colors with 1 signal light with economic profit presented the reform measure of energy efficiency improvement together.

  • PDF

A Method to Identify the Identification Eye Status for Drowsiness Monitoring System (졸음 방지 시스템을 위한 눈 개폐 상태 판단 방법)

  • Lee, Juhyeon;Yoo, Hyoungsuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1667-1670
    • /
    • 2014
  • This paper describes a method for detecting the pupil region and identification of the eye status for driver drowsiness detection system. This program detects a driver's face and eyes using viola-jones face detection algorithm and extracts the pupil area by utilizing mean values of each row and column on the eye area. The proposed method uses binary images and the number of black pixels to identify the eye status. Experimental results showed that the accuracy of classification eye status(open/close) was above 90%.

A Electronic Starter for Fluorescent Lamps for use as Neon Signs (네온사인 기능을 수행하는 형광램프용 전자식 스타터)

  • 송상빈;곽재영;여인선;임건호
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.228-233
    • /
    • 1999
  • In this paper we develop an electronic starter circuit that is suitable for Neon sign operation of switch-start fluorescent lamps. The developed starter enable single pulse ignition of fluorescent lamp at the peak point of preheating current, irrespective of the position of the Tum-On signal. This is possible due to the sequential operation of two transistors different in their operation characteristics and a diode operation characteristic. The switching endurance test using this starter has been carried for more than 3000 hours for a single switch-start on a severe blinking condition of preheating of 0.1s and of successive lighting interval of 0.1s.

  • PDF

Time Series Evaluation of Visual Fatigue and Depth Sensation Using a Stereoscopic Display

  • Kim, Sang-Hyun;Kishi, Shinsuke;Kawai, Takashi;Hatada, Toyohiko
    • Journal of Information Display
    • /
    • v.10 no.4
    • /
    • pp.188-194
    • /
    • 2009
  • Conventional stereoscopic (3D) displays using binocular parallax generate unnatural conflicts between convergence and accommodation. These conflicts can affect the observer's ability to fuse binocular images and may cause visual fatigue. In this study, time series changes in visual fatigue and depth sensation when viewing stereoscopic images with changing parallax were examined. In particular, the physiological changes, including the subjective symptoms of visual fatigue, when viewing five parallax conditions, were examined. Then a comparative analysis of the 2D and 3D conditions was performed based on the visual function. To obtain data regarding the visual function, the time series changes in the spontaneous-blinking rate before and during the viewing of 3D images were measured. The time series change results suggest that 2D and 3D images cause significantly different types of visual fatigue over the range of binocular disparity.