• Title/Summary/Keyword: blinking

Search Result 120, Processing Time 0.026 seconds

Case Study of Miso Facial Rejuvenation Acupuncture on Intractable Facial Palsy (중증 안면마비에 대한 미소안면침 증례보고)

  • Lee, Soh-Young;Ko, Jung-Min;Kim, Joo-Hee;Kwon, Hyo-Jung;Chung, Jie-Youn;Song, Jeong-Hwa;Choi, Do-Young;Lee, Jae-Dong;Lee, Sang-Hoon
    • Journal of Acupuncture Research
    • /
    • v.26 no.1
    • /
    • pp.163-171
    • /
    • 2009
  • Objectives : This study was designed to evaluate the effect of Miso Facial rejuvenation Acupuncture on severe cases of facial palsy. Methods : Facial palsy patients over the age of 70 with House-Brackmann grading system(HBGS) above Grade V were treated with Miso Facial rejuvenation Acupuncture. The effects of the treatment were evaluated via scales and picture. Results : Before treatment with Miso Facial rejuvenation acupuncture, the three patients showed H-B Gr V. After treatment, they showed improvement to H-B Gr II, III, and II respectively. There also formed nasolabial folds on the palsied side, with better blinking of the eyes, and improved asymmetry of the left and right face. Conclusions : Miso Facial rejuvenation Acupuncture showed marked improvement in intractable facial palsy. Randomized-controlled trial for further evaluation will be needed in the future.

  • PDF

Evaluation of In-vehicle Warning Information Modalities by Kansei Engineering (감성공학을 이용한 차내 경고정보 제공방식 평가)

  • Park, Jun-Yeong;O, Cheol;Kim, Myeong-Ju;Jang, Myeong-Sun
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.3
    • /
    • pp.39-49
    • /
    • 2010
  • Provision of in-vehicle warning information is of keen interest since it can be effectively used to prevent traffic accident on the road. This study evaluates the effectiveness of information provision modalities based on kansei engineering. Various warning information scenarios using different modalities are devised for the evaluation. Statistical data analysis techniques including factor analysis, correlation analysis, and the general linear model are used to assess the user's affect for information modalities. The evaluation result shows that the provision of visual information consisted of 'text and pictogram' leads to higher understandability. The combination of beep sound and voice message' was identified as a more effective modality for auditory warning. In addition, the red color for the blinking warning signal was preferred by users.

Damped Oscill ations of the (Hard)Contact Lenses Posterior to the Blink (순목 후 콘택트(하드)렌즈의 감쇄 진동)

  • Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.173-184
    • /
    • 2005
  • A capillary action-induced tension develops in the tear layer between the contact lens and cornea, which leads to the restoring force due to difference in the layer thickness between either upper and lower or left and right side of the lens when it is displaced off the equilibrium position as a result of blinking. Suppose the lens was displaced a certain distance from the equilibrium position, lens starts to oscillate toward the equilibrium position with the decreasing amplitude due to the restoring force as well as the velocity dependent viscous damping force in the tear layer. A mathematical model which consists of the differential equations and their numerical solution was proposed to analyze the damped oscillations of lenses. The model predicts the time dependence of lenses after the blink varying the various parameters such as Be, diameters, masses and positions displaced from equilibrium. As the Be and mass of lens increases the rate of amplitude reduction decreases, which requires a more time for the lens to return to the equilibrium position. It seems that varying the lens' displacement and diameters affect the lens' motion very little.

  • PDF

The stability of tear film for Korean (한국인에 대한 누액 안정성 조사)

  • Lee, Seong-Wook;Sim, Hyun-Seog;Jang, Seong-Joo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.161-164
    • /
    • 2001
  • The purpose of our study was stability of tear film for Korean. In the 1970s, the major problem for the contact lens practitioner was the management of contact lens parameters. In the 1980s, oxygen permeability was the main problem in contact lens practice: now it is dry eyes. To appropriately fit the patient with contact lenses it is imperative to know in advance if the patient has a marginal dry eye. Based on the initial diagnosis appropriate care can be taken to minimize problems with the result that the patient can successfully wear contact lenses. A well known test for dry eyes is Schirmer test which has shown to be useful for diagnosing Sjogren syndrome. Biomicroscopy can often unmask numerous problems. The classical test for marginal dry eye is measuring the tear break up time(TBUT). A dry eye problem with contact lenses is often caused by the lid. If an incomplete blink is responsible for the dry eye it is possible to change the situation by blinking exercises. The result of these test, mean value of age was 22.8, mean value of blink rate was 19 times/min, mean value of Schirmer test was 25 mm/5 min, mean value of TBUT was 7.1 sec.

  • PDF

The Effects of Drugs, including Alcohol, on Ocular Health and Contact Lens Wear (약물과 알코올이 눈과 콘택트렌즈에 미치는 영향)

  • Kim, Jae-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.73-81
    • /
    • 2000
  • This review on ocular toxicology concentrates on the effects on ocular health and contact lens wear induced by systemically used drugs, including alcohol. Many systemically administered drugs produce ocular adverse effects. Fortunately, relatively few are capable of causing significant, irreversible visual impairment. The visual symptoms of acute intoxication are as follows : Drop in vision/visual acuity, diplopia, poor dark adaptation, increase in time for glare recovery, early cataract, decreased depth perception, blue-yellow or red-green colour defect and visual hallucinations. Blinking pattern, tear production, and discoloration of contact lenses can be affected by some systemic or local ocular medications. The cornea, conjunctiva, or eyelids may react to some systemic medications and to some preservatives used in contact lens solutions. The hydrogel contact lens act as a drug reservoir that emits the drug over time. I discuss management of contact lens-induced infectious and inflammatory conditions.

  • PDF

Restoration of Blink Function in the Paralyzed Rabbit Using Electroactive Polymer (안면신경마비 동물모델에서 전기활성고분자를 이용한 눈 깜박임 기능의 회복)

  • Kwon, Seong-Keun;Sung, Myung-Whun;Kim, Kwang-Hyun;Kim, Hee-Chan
    • Korean Journal of Bronchoesophagology
    • /
    • v.12 no.2
    • /
    • pp.19-25
    • /
    • 2006
  • There have been numerous modalities to recover blink function of orbicularis oculi muscle in patients with facial paralysis. However, there is still no optimal method for reanimation of eyelid. In this study, we tried to recover blink function of paralyzed rabbit's eyelid with the ion polymer metal composite (IPMC) which is one of the electroactive polymers that is spotlighted as artificial muscle. We manufactured IPMC by plating the platinum over perfluorosulphonic acid polymer ($Nafion^{(R)}$). IPMC was coated by Norland optical adhesive for the purpose of insulation and keeping it from dry. IPMC modifications by roughening the surface of Nafion, repetitive plating (maximum 4 times) with platinum, and lengthening the width of IPMC were done. The facial paralysis was induced in the rabbit by sectioning of facial nerve at the main trunk. After minimum period of 4 weeks, IPMC was inserted in the paralyzed rabbit's eyelid. By modification, the force generated by IPMC was enhanced. Restoration of blink function in paralyzed rabbit was achieved on electrical stimulation of the IPMC by 5 voltage direct current. IPMC can be promising option for facial reanimation, but further studies are needed to enhance the efficiency of IPMC.

  • PDF

Expression Technique of the Plurality IR LED Marker using OOK Method for Augmented Reality (증강현실에서 OOK 기법을 이용한 다수의 IR LED 마커 표현 기술)

  • Lee, Hye-Mi;Ryu, Nam-Hoon;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.2
    • /
    • pp.433-438
    • /
    • 2012
  • With technologies available now, there are only a few virtual objects that augmented reality content can create. So, wider application of it is limited. If people want to realize any augmented reality content, out of a vast amount of materials available as well as virtual objects, the number of virtual objects that markers can render should be made to go up along with the content. In a precedent study, IR LEDs markers render marker information following On-Off signals. The number of LEDs should be raised to render as much information as possible, subsequently leading to the problem of oversized markers. This problem can be solved by generating data signals through the blinking of LEDs. This research puts forward OOK Code algorithm that represents the mode of data transmission using the light of LEDs. The amount of information that can be rendered by a marker increases and the size of the marker gets smaller, which is a merit, when it receives data signals from light.

The Treatment of Sequela of Facial Nerve Palsy Using Facial Rejuvenation Acupuncture : Case Report (안면성형침을 이용한 안면신경마비 후유증의 치험례 보고)

  • Chu, Min-Gyu;Jo, Hee-Guen;Park, Soo-Gon;Kim, Sun-Jong;Yang, Mi-Sung;Choi, Jin-Bong;Jung, Min-Young;Lee, Hyoun
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.4
    • /
    • pp.175-187
    • /
    • 2009
  • Objectives : This study was performed to evaluate the effect of facial rejuvenation acupuncture on cases of sequela of facial nerve palsy. Methods : This study was carried out in respect of 5 cases of sequela of facial nerve palsy patients which had been treated in Dong-Shin university oriental hospital from 2009 year with House-Brackmann grading system(HBGS) above Grade IV. In this study the patients were treated by facial rejuvenation acupuncture. The effect of the treatment were evaluated via scales and picture. Results : After treatment with facial rejuvenation acupuncture, 5 patients improved H-B scale and symptoms of the sequela of facial nerve palsy. The average of H-B scale was increased from 3.2 to 6.4. There also formed forehead folds, better blinking of the eyes and improved asymmetry of the left and right face. Conclusions : In the study, facial rejuvenation acupuncture showed marked improvement in sequela of facial nerve palsy. Randomized-controlled trial for further evaluation will be needed in the future.

Voice signal transmission using VLC communication (VLC 통신을 이용한 음성신호 전송)

  • Kim, Byun-Gon;Kim, Myung-Soo;Jeong, Kyeong-Taek;kwon, Oh-Shin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.656-659
    • /
    • 2017
  • In this paper, we propose a digital method for transmitting audio signals using LED visible light communication system. In the proposed method, we compare the method for transmitting audio signal in analog signal and the method for transmitting by digital signal. When amplifying the audio sound and transmitting the analog signal using the LED visible light communication, attenuation corresponding to the transmission distance occurs, and there is a disadvantage that it is noisy. In order to overcome this, we propose a method for transmitting digital audio signals. The proposed method has the advantage of reducing the influence of noise, but it turned out that it is affected much by the LED blinking speed. Various methods to overcome this need to be continuously studied.

  • PDF

Auditory responses in neonates; a preliminary report (신생아에서 관찰할 수 있는 청성반응)

  • 황순재;노관택
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.4.1-4
    • /
    • 1977
  • A variety of diagnostic means for evaluating the hearing ability of neonates and infants have been studied so far, and some physical responses of neonates and infants to loud sound is still of much value. The author studied some normal responses of 100 neonates (male 54, female 46) in our neonatal room from Jan, 1977 to April, 1977. We took 90dB pure tone at 3, 000Hz by Beltone Audiometer model l0D (ANSI 1969) for a stimulus. The results are as follows: 1. The range of the examinees' age is between 2 and 3.5 hours (average 2.4 hours), and auropalpebral response is in 39% (eyelid blinking 10%, eyelid widening 29%), Moro reflex in 35%, sucking response in 14%, cessation of movement in 6%, head turning response in 2%, and no response in 4%. 2. The duration of response is between 2 and 5 Seconds (average 3.3 seconds).

  • PDF