유방엑스선검사 시 유방, 갑상샘, 안구 피폭선량 감소를 위한 차폐체 비교 (Comparison of Shield of Breast, Thyroid, Eyes for Exposure Dose Reduction in Mammography)

  • 안세정;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.189-194
    • /
    • 2021
  • This study was conducted to reduce the exposure dose to the breast and adjacent organs as the number of Mammography increased. Therefore, it has been designed a shield in lead, bismuth + tungsten, and bismuth that does not require to be equipped by the patient, in which each type of shield was compared and analyzed of radiation exposure dose to breast, thyroid, and eye. Using a mammography machine, optically stimulated luminescent dosimeter(OSLD) was inserted to bilateral breast, thyroid, and eye of a dosimetry phantom to measure dose radiated onto the phantom. Shielding device was made in different thickness of 2mm, 3mm, and 5mm and dose evaluation was performed by measuring the dose while using lead, bismuth, and bismuth + tungsten prosthesis. When each shields combined with shielding device, were compared of dose, all showed similar does reduction in the dose to breast, thyroid, and eye in both cranialcaudal and mediolateraloblique view. Based on the current study, bismuth and bismuth + tungsten can replace conventional lead shield and it is anticipated to safely and conveniently reduce radiation exposure to breast, thyroid, and eye with the shield that does not require to be equipped.

Comparison of the Breast Dose based on the Existence of the Bismuth Breast Protection Shield for Automatic Exposure Control and Manual Exposure Control with the Coronary Artery CT Angiography

  • Kim, Sang-Tae;Kang, Sang-Koo;Kim, Chong-Yeal
    • International Journal of Contents
    • /
    • 제7권4호
    • /
    • pp.103-107
    • /
    • 2011
  • The effective dose and the organ absorbed dose, which are given to a breast in the cases of using and not using the bismuth breast protection shield for the protection of a breast with the coronary artery CT angiography, have been measured and compared for the manual exposure control (MEC)and the automatic exposure control (AEC). In the cases of using and not using the bismuth breast protection shield, it has been found that the measured dose shows the reduction of about 23 to 26% for the MEC and about 22 to 25% for the AEC when the shield is used compared to the case of not using it. By comparing the shield and non-shield cases for the AEC and the MEC, it can be said that the value measured by carrying out the scanning process with the AEC mode has decreased by about 24 to 30% compared to the case of applying the MEC mode. Such a result shows that it is recommended to use the AEC mode for the reduction of the patient's exposure dose during the CT examination.

비스무스 차폐체의 유방 차폐율 분석 (Analysis of breast shielding rate of bismuth shield)

  • 김재석
    • 한국정보통신학회논문지
    • /
    • 제24권9호
    • /
    • pp.1132-1137
    • /
    • 2020
  • 유방 X선 촬영 장치를 이용한 유방 촬영을 실시할 때 발생되는 불필요한 피폭 선량을 경감시키기 위해 비스무스로 제작한 차폐체를 촬영 부위의 반대 측 유방에 적용했을 때 차폐율 분석을 실시하였다. 오른쪽, 왼쪽을 압박하였을 때 CC와 MLO 검사 시 압박되지 않는 유방의 산란 선량을 알아보기 위하여 비스무스를 차폐하지 않았을 때(Not used : NU그룹)와 차폐했을 때(Used : U그룹)로 구분하여 실험을 진행하였다. NU 그룹의 평균선량은 9.568μSv이었고, U그룹의 평균 선량은 1.038μSv이었다. 비스무스 차폐체 사용 전후의 평균 측정 선량은 89.15% 감소되었다. 유방 촬영용 비스무스 차폐체를 사용하면 산란 방사선을 차폐하여 방사선에 의한 노출을 최소한으로 유지할 수 있다.

비스무스 차폐체 개발을 통한 소아 방사선검사의 피폭에 관한 연구 (Pediatric Radiation Examination by Development of Bismuth Shield Research on Radiation Exposure)

  • 김훈;김용근;김준년;위승현;박은경;채명준;백부길;김은혜;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.205-211
    • /
    • 2024
  • Currently, with the development of technologies, X-ray examinations for medical examinations at hospital is increasing. This study was conducted to help reduce radiation exposure by measuring the exposure dose received by pediatric patients and the spatial dose of the X-ray room. Dosimeters were installed in the eyeball, thyroid gland, breast, gonads and 4 directions at a distance of 30 cm, 40 cm, 50 cm from the phantom. The dose was measured ten times each, before, and after the application of the bismuth shield under the examination conditions of the head, chest, and abdomen of pediatric patients. Under the condition of head examination, when a shielding was applied, the dose reduction rate was 68.58% for the eyeball, 72.88% for the thyroid, 84.2% for the breast, and 72.36% for the gonad. The chest examination showed reductions of 19.56% eyeball, 56.98% thyroid, 1.21% breast, and 0.68% gonad. The abdominal examination showed reduction rates of 2.6% eyeball, 10.67% thyroid, 19.85% breast, and 82.02% gonad. Spatial dose decreased by 62.25% at 30 cm, 61.16% at 40 cm, and 68.68% at 50 cm. When the bismuth shield was applied, there was a decrease in dose across all examinations, as well as a reduction in spatial dose. Continued research on the use of bismuth shields will help radiological technologists achieve their goal of dose reduction.

방사선 치료 시 차폐물질 사용에 따른 kV-CBCT 선량감소 효과 (Reduced Effect of kV-CBCT Dose by Use of Shielding Materials in Radiation Therapy)

  • 조현종;박은태;김정훈
    • 한국방사선학회논문지
    • /
    • 제12권4호
    • /
    • pp.467-474
    • /
    • 2018
  • CBCT는 치료부위의 정확도 향상에 유용하지만, 반복적인 사용으로 피폭선량이 높아지는 단점이 있다. 이에 본 연구에서는 차폐체를 사용한 모의실험과 선량감소 효과를 데이터화하여 CBCT 시행 시 선량 저감화를 위한 기초자료를 제공하고자 한다. 본 연구에서는 MCNPX를 통해 CBCT를 모사하여 광자선을 분석한 후, UF-revised 인체 모의 피폭체를 대상으로 흉복부 촬영 시 장기의 흡수선량을 계산하였다. 이 때, 차폐체(납, 안티몬, 황산바륨, 텅스텐, 비스무스) 유무와 차폐 재질에 따른 장기선량을 평가하였다. 차폐를 하지 않고 CBCT 촬영을 하였을 경우 유방 과 척추에서 선량이 높게 계산되었으며, 식도와 폐에서 선량이 낮게 계산되었다. 차폐체 재질에 따른 선량 은 황산바륨, 안티몬, 비스무스, 납, 텅스텐 순으로 선량이 높게 계산되었다. 차폐체 유무에 따른 선량 감소율을 평가해 보면 흉선(73.6%), 유방(59.9%)에서 가장 차폐율이 높고, 폐(2.1%), 척추(12.6%)에서 가장 낮은 차폐율을 보였다.

PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가 (The Usability Evaluation of the Usefulness of Bismuth Shields in PET/CT Examination)

  • 박훈희;이주영;김지현;남궁식;유광열;이태수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권1호
    • /
    • pp.49-56
    • /
    • 2014
  • 최근 PET/CT는 CT의 발전과 함께, 피폭선량의 저감화를 위한 다양한 연구가 진행되고 있다. 이러한 연구 중 비스무스(bismuth) 차폐체에 관한 연구가 활발하게 진행 중이지만 현재 PET/CT 검사에서의 적용은 활성화 되지 않았다. 그러므로 본 연구를 통하여 PET/CT 검사에서의 비스무스 차폐체의 적용에 따라 영상의 질과, 표준화섭취계수(SUV)에 미치는 영향을 확인하는데 목적을 두었다. 유방차폐의 적용을 위해 0.06 mm Pb 성분을 포함하고 있는 비스무스 차폐체(AttenuRad_F&L Medical Product Co, USA)를 사용하여 PET/CT 장비 GEMINI TF 64(Philips Healthcare, Cleveland, USA)에 적용하였다. 실험은 NEMA IEC Body Phantom을 사용하여 비스무스 차폐체 적용 유무에 따른 영상을 획득하였다. 또한 적용 시에는 0cm, 1cm, 2cm의 간격 변화를 주어 영상을 획득하였고, 각각의 영상을 EBW(Extended Brilliance Workstation)NM ver.1.0을 이용 팬텀의 Depth에 다른 관심영역을 설정하고 표준섭취계수를 각각 10회씩 측정, 분석하였다. 또한 SPSS ver.18을 통해 통계 분석하였다. PET의 방출(Emission)영상 획득 시 비스무스 차폐체의 적용으로 발생한 방사선 경화현상에 기인하여 표준섭취계수가 증가한 것을 확인하였으며(P<0.005), 깊이에 따른 차이는 팬텀의 심부에서 표면으로 갈수록 표준섭취계수가 증가하였다(P<0.005). 또한 차폐체 사용 시 간격이 줄어들수록 표준섭취계수가 증가하는 것을 확인하였다(P<0.005). 본 연구를 통해 피폭저감을 목적으로 사용하는 비스무스 차폐체의 PET/CT에서의 검사에 적용을 고려할 수 있다. 차폐체 적용에 따른 표준섭취계수의 차이가 존재하며 그 차이는 차폐체와 표면의 간격이 넓을수록 줄어든다. 그러므로 차폐체의 충분한 간격 설정이 고려되어야 할 것이며, 영상의 질과 표준섭취계수 편차의 감소를 고려한다면, 질환에 따라 표재성 질환보다는 심부나 타 장기의 적용이 우선시 되어야 할 것이다. 또 한 비스무스차폐체 사용에 따른 표준섭취계수를 감안한 임상 검사 적용 시, 불필요한 피폭감소 효과를 기대할 수 있을 것으로 사료된다.

PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가 (The Usability Evaluation According to the Application of Bismuth Shields in PET/CT Examination)

  • 남궁식;김지현;이주영;박훈희
    • 핵의학기술
    • /
    • 제17권1호
    • /
    • pp.36-42
    • /
    • 2013
  • 최근 PET/CT는 CT의 발전과 함께, 피폭선량의 저감화를 위한 다양한 연구가 진행되고 있다. 이러한 연구 중 비스무스(bismuth) 차폐체에 관한 연구가 활발하게 진행 중이지만 현재 PET/CT 검사에서의 적용은 활성화 되지 않았다. 그러므로 본 연구를 통하여 PET/CT 검사에서의 비스무스 차폐체의 적용에 따라 영상의 질과, 표준화섭취계수(SUV)에 미치는 영향을 확인하는데 목적을 두었다. 유방차폐의 적용을 위해 0.06 mmPb 성분을 포함하고 있는 비스무스 차폐체 (AttenuRad__F&L Medical Product Co, USA)를 사용하여 PET/CT 장비 GEMINI TF 64 (Philips Healthcare, Cleveland, USA)에 적용하였다. 실험은 NEMA IEC Body Phantom을 사용하여 비스무스 차폐체 적용 유무에 따른 영상을 획득하였다. 또한 적용 시에는 0cm, 1cm, 2cm의 간격 변화를 주어 영상을 획득하였고, 각각의 영상을 EBW (Extended Brilliance Workstation)NM ver.1.0을 이용 팬텀의 Depth에 다른 관심영역을 설정하고 표준섭취계수를 각각 10회씩 측정, 분석하였다. 또한 SPSS ver.18을 통해 통계 분석하였다. PET의 방출(Emission)영상 획득 시 비스무스 차폐체의 사용에 따라 표준섭취계수가 증가한 것을 확인하였으며 (P<0.005), 깊이에 따른 차이는 팬텀의 심부에서 표면으로 갈수록 표준섭취계수가 증가하였다(P<0.005). 또한 차폐체 사용 시 간격이 줄어들수록 표준섭취계수가 증가하는 것을 확인하였다(P<0.005). 본 연구를 통해 피폭저감을 목적으로 사용하는 비스무스차폐체의 PET/CT에서의 검사에 적용을 고려할 수 있다. 차폐체 적용에 따른 표준섭취계수의 차이가 존재하며 그 차이는 차폐체와 표면의 간격이 넓을수록 줄어든다. 그러므로 차폐체의 충분한 간격 설정이 고려되어야 할 것이며, 영상의 질과 표준섭취계수 편차의 감소를 고려한다면, 질환에 따라 표재성 질환보다는 심부나 타 장기의 적용이 우선시 되어야 할 것이다. 또한 비스무스차폐체 사용에 따른 표준섭취계수를 감안한 임상 검사 적용 시, 불필요한 피폭 감소 효과를 기대할 수 있을 것으로 사료된다.