Comparison of Shield of Breast, Thyroid, Eyes for Exposure Dose Reduction in Mammography (유방엑스선검사 시 유방, 갑상샘, 안구 피폭선량 감소를 위한 차폐체 비교)

  • An, Se-Jeong;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.189-194
    • /
    • 2021
  • This study was conducted to reduce the exposure dose to the breast and adjacent organs as the number of Mammography increased. Therefore, it has been designed a shield in lead, bismuth + tungsten, and bismuth that does not require to be equipped by the patient, in which each type of shield was compared and analyzed of radiation exposure dose to breast, thyroid, and eye. Using a mammography machine, optically stimulated luminescent dosimeter(OSLD) was inserted to bilateral breast, thyroid, and eye of a dosimetry phantom to measure dose radiated onto the phantom. Shielding device was made in different thickness of 2mm, 3mm, and 5mm and dose evaluation was performed by measuring the dose while using lead, bismuth, and bismuth + tungsten prosthesis. When each shields combined with shielding device, were compared of dose, all showed similar does reduction in the dose to breast, thyroid, and eye in both cranialcaudal and mediolateraloblique view. Based on the current study, bismuth and bismuth + tungsten can replace conventional lead shield and it is anticipated to safely and conveniently reduce radiation exposure to breast, thyroid, and eye with the shield that does not require to be equipped.

Comparison of the Breast Dose based on the Existence of the Bismuth Breast Protection Shield for Automatic Exposure Control and Manual Exposure Control with the Coronary Artery CT Angiography

  • Kim, Sang-Tae;Kang, Sang-Koo;Kim, Chong-Yeal
    • International Journal of Contents
    • /
    • v.7 no.4
    • /
    • pp.103-107
    • /
    • 2011
  • The effective dose and the organ absorbed dose, which are given to a breast in the cases of using and not using the bismuth breast protection shield for the protection of a breast with the coronary artery CT angiography, have been measured and compared for the manual exposure control (MEC)and the automatic exposure control (AEC). In the cases of using and not using the bismuth breast protection shield, it has been found that the measured dose shows the reduction of about 23 to 26% for the MEC and about 22 to 25% for the AEC when the shield is used compared to the case of not using it. By comparing the shield and non-shield cases for the AEC and the MEC, it can be said that the value measured by carrying out the scanning process with the AEC mode has decreased by about 24 to 30% compared to the case of applying the MEC mode. Such a result shows that it is recommended to use the AEC mode for the reduction of the patient's exposure dose during the CT examination.

Analysis of breast shielding rate of bismuth shield (비스무스 차폐체의 유방 차폐율 분석)

  • Kim, Jae Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1132-1137
    • /
    • 2020
  • In order to reduce unnecessary exposure doses generated when mammography is performed using a mammography device, a shielding ratio analysis was performed when a self-made shielding body made of bismuth was applied to the breast opposite to the imaging site. In order to determine the scattering dose of uncompressed breasts during CC and MLO tests when the right and left are compressed, the experiment is divided into when bismuth is not shielded (Not used: NU group) and when shielded (Used: U group). Proceeded. The average dose of the NU group was 9.568μSv, and the average dose of the U group was 1.038μSv. The average measured dose before and after the use of the bismuth shield was reduced by 89.15%. The use of a bismuth shield for mammography can shield scattered radiation and keep exposure to radiation to a minimum.

Pediatric Radiation Examination by Development of Bismuth Shield Research on Radiation Exposure (비스무스 차폐체 개발을 통한 소아 방사선검사의 피폭에 관한 연구)

  • Hoon Kim;Yong-Keun Kim;Joon-Nyeon Kim;Seung-Hyun Wi;Eun-Kyung Park;Myung-Jun Chae;Bu-Gil Baek;Eun-Hye Kim;Cheong-Hwan Lim
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.205-211
    • /
    • 2024
  • Currently, with the development of technologies, X-ray examinations for medical examinations at hospital is increasing. This study was conducted to help reduce radiation exposure by measuring the exposure dose received by pediatric patients and the spatial dose of the X-ray room. Dosimeters were installed in the eyeball, thyroid gland, breast, gonads and 4 directions at a distance of 30 cm, 40 cm, 50 cm from the phantom. The dose was measured ten times each, before, and after the application of the bismuth shield under the examination conditions of the head, chest, and abdomen of pediatric patients. Under the condition of head examination, when a shielding was applied, the dose reduction rate was 68.58% for the eyeball, 72.88% for the thyroid, 84.2% for the breast, and 72.36% for the gonad. The chest examination showed reductions of 19.56% eyeball, 56.98% thyroid, 1.21% breast, and 0.68% gonad. The abdominal examination showed reduction rates of 2.6% eyeball, 10.67% thyroid, 19.85% breast, and 82.02% gonad. Spatial dose decreased by 62.25% at 30 cm, 61.16% at 40 cm, and 68.68% at 50 cm. When the bismuth shield was applied, there was a decrease in dose across all examinations, as well as a reduction in spatial dose. Continued research on the use of bismuth shields will help radiological technologists achieve their goal of dose reduction.

Reduced Effect of kV-CBCT Dose by Use of Shielding Materials in Radiation Therapy (방사선 치료 시 차폐물질 사용에 따른 kV-CBCT 선량감소 효과)

  • Jo, Hyeonjong;Park, Euntae;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.467-474
    • /
    • 2018
  • CBCT is useful for improving the accuracy of the treatment site, but Repeated use increases the exposure dose. In this study, we aimed to provide basic data for dose reduction in CBCT implementation by dataization the simulating and dose reduction effect using shielding substance. Material in this study, Analyzation the photon beam by simulate the CBCT Through MCNPX and then calculate the absorption dose of body organ at shooting moment of thoracic abdominal position as target UF-Revise simulated body. At this time. Dose reduction effects at this time were evaluated according to the texture of materials and presence of shielding materials( lead, antimony, barium, sulfate, tungsten, bismuth). When CBCT was taken without shielding, the dose was calculated to be high in the breast and spine, and the dose in the esophagus and lung was calculated to be low. The doses according to the shield material were calculated as barium sulfate, antimony, bismuth, lead, and tungsten. The shielding rate was the highest in the thymus (73.6%) and the breast (59.9%) compared with the dose reduction according to presence or absence of the shield. However, it showed the lowest shielding rate in lung (2.1%) and spine (12.6%).

The Usability Evaluation of the Usefulness of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Ji-Hyeon;Nam, Kun-Sik;Lyu, Kwang-Yeul;Lee, Tae Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2014
  • Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we identify the quality of the image and the impact on the Standard Uptake Value (SUV). In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mm Pb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference when gab is decrease and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep organs should be a priority rather than superficial organ disease. Use of bismuth shielding factor considering the standard clinical examination, decrease unnecessary exposure can be expected to be considered.

The Usability Evaluation According to the Application of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Nam-Kung, Sik;Kim, Ji Hyeon;Lee, Ju young;Park, Hoon Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.36-42
    • /
    • 2013
  • Purpose: Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we want to identify the quality of the image and the impact on the SUV. Materials and Methods: In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mmPb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. Results: When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Conclusion: Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose be considered. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference is more decreased as gab of shields and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep or other organs should be a priority rather than superficial disease. Through this study, when applying identified to clinical examination, the reduction of unnecessary exposure is considered.

  • PDF