• Title/Summary/Keyword: bis(2-carboxyethylgermanium sesquioxide)

Search Result 2, Processing Time 0.013 seconds

Growth Characteristics and Germanium Absorption of Soybean Sprout Cultured with the Aqueous Solution of Organogermanium (유기게르마늄 수용액으로 재배된 콩나물의 생육특성과 게르마늄 흡수량)

  • Rim, Yo-Sup;Jeong, Jae-Hun;Han, Seong-Soo
    • Applied Biological Chemistry
    • /
    • v.39 no.1
    • /
    • pp.39-43
    • /
    • 1996
  • In order to cultivate the soybean sprout fortified with organogermanium, we observed growth characteristics and germanium content of soybean sprout watered with the aqueous organogermanium, Ge-132[bis(2-Carboxyethylgermanium sesquioxide)]. Soybean sprout did not show difference in growth when treated with different times and frequencies of organogermanium or different types of germanium. Growth of Orialtae soybean sprout was smaller in diameter of hypocotyledonary axis and longer in total length than that of Danyeob soybean sprout. Three hour's soaking was better in growth than half an boar's treatment. Germanium absorbed by soybean sprout was greater in content in Danyeob soybean sprout than in Orialtae soybean sprout and highest at 20 ppm in water. Prolonged period and increased frequency in treatments with organic germanium resulted in increase of germanium uptake. Germanium content in soybean sprout was greater with treatment of organic germanium than with inorganic germanium.

  • PDF

Analysis of organic germanium, Ge-132 (유기게르마늄 화합물인 Ge-132의 분석법)

  • Park, Man Ki;Park, Jeong Hill;Han, Sang Beom;Park, Il Ho
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.371-374
    • /
    • 1995
  • An organic germanium compound, Ge-132, was reported to have interferon inducer activity, anti-tumor activity and anti-viral activity. ICP, AA and colorimetry methods were used for the determination of germanium in Ge-132. However these methods have a problem that they only give an information on the total amount of germanium element, and consequently Ge-132 connot be distinguished form toxic inorganic Ge compounds. To overcome this problem, ion chromatography was used to analyze Ge-132. Ge-132 was separated on Ionpac AS4A column with 1.3mM $Na_2B_4O_7$ buffer(pH=9.2) solution as an eluent and detected by the conductivity detector. Correlation coefficient of the calibration curve was 0.999 and the detection limit measured at S/N ratio of 3 was 50pmol. This method was applicable to the analysis of Ge-132 raw material and Ge-132 preparations.

  • PDF