• Title/Summary/Keyword: biomedical monitoring

Search Result 456, Processing Time 0.027 seconds

A Rapid, Simple Determination of Sulfur-containing Compounds and Methylmalonic Acid on Plasma using GC-MS-SIM for the Diagnosis of Homocysteinemia (혈장 중 황함유 화합물과 메틸말론산의 신속 간편한 분석법 개발; GC-MS-SIM을 이용한 호모시스테인혈증의 진단)

  • Yoon, Hye-Ran;Thapa, Maheshwor
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.3
    • /
    • pp.138-146
    • /
    • 2015
  • Purpose: If early diagnosis is not made, patients with metabolic disorders as homocystinemia rapidly progress to physical defect or mental retardation resulted in storage of the toxic material into the brain. Therefore, it is necessary to develop an analytical method for a rapid screening and/or correct confirmation diagnosis. Methods: The standard solution of sulfur amino acids spiked plasma was subjected to protein precipitation with methanol, and then consecutively derivatized with trimethylsilyl (TMS) and trifluoroacyl (TFA) and determined by GC-MS. The formation of TMS derivative of the hydroxyl and TFA derivative of amino functional group was performed by BSTFA and MBTFA, respectively. Selective ion monitoring (SIM) mode was used for quantification with selected specific ions. Results: A calibration curve on standard spiked pooled plasma showed a linear relationship with correlation coefficient of 0.9936-0.9992 for all compounds over the range of 0.1-300 ng. The precision and accuracy were within S.D. of 1-15% and RSD of 1-15% for intra-day assay at 2 ng/mL, 15 ng/mL and 30 ng/mL. LOD and LOQ was 0.4 ng/mL and 4 ng/mL respectively. Conclusion: A rapid analytical method was developed to quantify sulfur amino acids and methyl malonic acid, after two-step derivatization procedure with good sensitivity and specificity on human plasma. Advantages of a new method are simplicity and rapidity. The method could be useful for routine analysis, diagnosis of homocysteinemia.

Molecular Characterization of Fluoroquinolone Resistant Escherichia coli Isolates from Chickens in Korea (닭에서 동정된 플르오르퀴놀론 내성 대장균 균주의 분자생물학적 성상에 관한 연구)

  • Sung, Ji-Youn;Oh, Ji-Eun
    • Journal of Digital Convergence
    • /
    • v.14 no.4
    • /
    • pp.371-378
    • /
    • 2016
  • An aim of current study was to investigate the prevalence and the mechanism of quinolone-resistance in E. coli isolates obtained from chicken cecum in Korea. In addition, multilocus sequence typing (MLST) was also performed for the molecular characterization of E. coli isolates. In an antimicrobial susceptibility test by the disk diffusion method, the 63.5% (54/85) of E. coli isolates showed the resistance to quinolone group of antimicrobial agents. All of the 54 E. coli isolates showing resistant to quinolone group had sense mutations in gyrA gene and point mutations at the $57^{th}$, $80^{th}$, or $84^{th}$ residues in parC gene were detected in 90.7% of the isolates. Interestingly, E. coli ST was closely related to amino acid substitutions in parE gene. Our results indicated that the long-term use of antimicrobial agents in food-producing animals was strongly associated with a prevalence of antimicrobial resistance in commensal Enterobacteriaceae, suggesting the need for continuous surveillance and monitoring of antimicrobial resistant determinants in bacterial isolates from food animals.

Quantitative Analysis of Lovastatin in Human Plasma and urine by Reversed-Phase High-Performance Liquid Chromatography (역상 고속액체크로마토그라프법을 이용한 혈장 및 뇨 중 로바스타틴의 정량)

  • Choi, Hye-Jin;Kim, Myoung-Min;Choi, Kyung-Eob
    • YAKHAK HOEJI
    • /
    • v.42 no.5
    • /
    • pp.473-479
    • /
    • 1998
  • Lovastatin (LOVA), a fungal metabolite isolated from cultures of Aspergillus terreus, is a competitive HMG-CoA reductase inhibitor used for the treatment of primary hyper cholesterolemia, and has also been shown to suppress growth in a variety of non-glioma tumor cell lines. A sensitive reversed-phase high-perfonnance liquid chromatographic method with ultraviolet (UV) absorbance detection has been developed to quantitate LOVA in human plasma and urine samples using liquid-liquid extraction procedure. Baseline separation of LOVA and internal standard, simvastatin was achieved on a Novapak $C_{18}$ analytical column with a mobile phase containing 0.025M $NaH_2PO_4$: CAN (35:65, v/v%), adjusted pH to 4.5. The flow rate was set at 1.5ml/min, and the column effluent was monitored by a UV detection at 238nm. The limit of quantification was determined to be 0.5${\mu}$g/ml while extraction efficiency of LOVA ranged from 73.4-82.9% at LOVA concentrations of 0.5 to 10${\mu}$g/ml. Good linearity with correlation coefficients greater than 0.999 was obtained in the range of LOVA concentrations from 0.5 to 10${\mu}$g/ml. The accuracy and the precision were proven excellent with relative standard deviation (RSD, %) and relative error (RE, %) of less than 4.2 and 4.0, respectively. Intraday precision, evaluated at five LOVA concentrations (0.5, 1, 2, 5, 10${\mu}$g/ml) and expressed as RSD ranged from 0-1.82% while the interday precision at the same concentrations ranged from 0.7-10.5%. The analytical method described was then successfully employed for the determination of LOVA concentrations in plasma samples obtained during a phase II clinical trial using high doses of LOVA (30-40mg/kg/day). This method could be further utilized for the ongoing pharmacolkinetic studies and therapeutic drug monitoring of the high-dose LOVA therapy in adenocarcinoma patients.

  • PDF

Effect of p-Phenylenediamine Application to Rat Skin on the Liver Oxygen Free Radical Systems

  • Park, Hye-Jung;Lee, Sang-Hee;Yoon, Chong-Guk
    • Biomedical Science Letters
    • /
    • v.9 no.2
    • /
    • pp.75-84
    • /
    • 2003
  • To evaluate the influence of hepatic oxygen free radical systems on liver injury by topical p-phenylenediamine (PPD) application on rat skin, PPD (25 mg/16.5 $\textrm{cm}^2$) was topically applied to the abdominal region 5 times every other day and sacrificed. By PPD treatment, increasing rate of liver weight/body weight (%), serum activities of alanine aminotransferase and aspartate aminotransferase and decreasing rate of microsomal glucose-6-phosphatase activity were higher in the rats fed tungstate supplemented diet than those fed a standard diet. These findings indicate that group fed tungstate supplemented diet have more severe liver injury compared with group fed standard diet on topical PPD application. However, the activities of oxygen free radical generating enzymes such as xanthine oxidase (XO) and cytochrome P450 dependent aniline hydroxylase and those of oxygen free radical scavenging enzymes were not found to be different between these two animal groups. In the present study, a novel monitoring method to detect the generating of oxygen free radicals in liver extract was devised. Throughout this method, the oxidized PPD produced by oxygen free radicals was determined colorimetrically. The increasing rate of PPD oxidation by liver homogenate was higher in tungstate fed animals than in standard diet fed ones. Among the fractionations of liver extract, the mitochondrial and postmitochondrial fractions in the liver extract of tungstate fed animals led to a higher availability of PPD oxidation by PPD treatment compared with standard diet fed ones. In conclusion, these results suggest that an enhanced liver injury in tungstate fed animals treated with PPD may be due to oxygen free radicals produced in other systems except oxygen free radicals generating from cytosolic XO system. Especially, oxidative availability by PPD can be used for oxygen free radical detection in some tissue.

  • PDF

Analysis of HR-HPV Prevalence among Unvaccinated Busan Women

  • Dong Hyeok Kim;Kyung Eun Lee
    • Biomedical Science Letters
    • /
    • v.28 no.4
    • /
    • pp.229-236
    • /
    • 2022
  • To prevent cervical cancer, human papillomavirus (HPV) bivalent and quadrivalent vaccinations are common, but there is a need for a vaccination system based on the high-risk human papillomavirus (HR-HPV) genotype that differs by region. This study aimed to investigate the prevalence of HPV and the distribution of HR-HPV genotypes in 2,014 women who were not vaccinated against HPV. In this study, HPV DNA testing was performed on 2,014 women not vaccinated against HPV and who visited the Busan Obstetrics and Gynecology Department from September 2020 to July 2021. In addition, liquid-based cytology (LBC) test was performed on 493 cases of HR- HPV genotype infection confirmed by HPV DNA test. The prevalence of HPV among women in Busan was positive in 609 (30.2%) out of 2,014 cases. Among the 609 HPV-positive cases, HR-HPV infection accounted for 493 cases (81.0%), which is a high proportion. Of the total 493 HR-HPV infection cases, liquid-based cytology (LBC) was within normal limits (WNL) in 266 cases (54.0%), atypical squamous cells of undetermined significance (ASCUS) in 97 cases (19.7%), low-grade squamous intraepithelial lesion (LGSIL) in 88 cases (17.8%), and high-grade squamous intraepithelial lesion (HGSIL) in 42 cases (8.5%). Single HR-HPV 52 and 16 accounted for the highest and second highest infection rates, respectively. The high infection rate among women aged 18~39 underscores the need for continuous monitoring. In addition, when there were abnormal findings in the cervical epithelium, HPV 52 was the most common, while in the case of HGSIL, HPV 16 was the most common. The HR-HPV genotypes related to cervical cancer should be continuously collected and monitored for use in health policies, including local and national vaccinations.

Development of an Automatic PCR System Combined with Magnetic Bead-based Viral RNA Concentration and Extraction

  • MinJi Choi;Won Chang Cho;Seung Wook Chung;Daehong Kim;Il-Hoon Cho
    • Biomedical Science Letters
    • /
    • v.29 no.4
    • /
    • pp.363-370
    • /
    • 2023
  • Human respiratory viral infections such as COVID-19 are highly contagious, so continuous management of airborne viruses is essential. In particular, indoor air monitoring is necessary because the risk of infection increases in poorly ventilated indoors. However, the current method of detecting airborne viruses requires a lot of time from sample collection to confirmation of results. In this study, we proposed a system that can monitor airborne viruses in real time to solve the deficiency of the present method. Air samples were collected in liquid form through a bio sampler, in which case the virus is present in low concentrations. To detect viruses from low-concentration samples, viral RNA was concentrated and extracted using silica-magnetic beads. RNA binds to silica under certain conditions, and by repeating this binding reaction, bulk samples collected from the air can be concentrated. After concentration and extraction, viral RNA is specifically detected through real-time qPCR (quantitative polymerase chain reaction). In addition, based on liquid handling technology, we have developed an automatic machine that automatically performs the entire testing process and can be easily used even by non-experts. To evaluate the system, we performed air sample collection and automated testing using bacteriophage MS2 as a model virus. As a result, the air-collected samples concentrated by 45 times then initial volume, and the detection sensitivity of PCR also confirmed a corresponding improvement.

Enhancement of preimplantation mouse embryo development with optimized in vitro culture dish via stabilization of medium osmolarity

  • Hyejin Yoon;Jongwoo Lee;Inyoung Kang;Kyoo Wan Choi;Jaewang Lee;Jin Hyun Jun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.50 no.4
    • /
    • pp.244-252
    • /
    • 2023
  • Objective: We evaluated the efficacy of the newly developed optimized in vitro culture (OIVC) dish for cultivating preimplantation mouse embryos. This dish minimizes the need for mineral oil and incorporates microwells, providing a stable culture environment and enabling independent monitoring of individual embryos. Methods: Mouse pronuclear (PN) zygotes and two-cell-stage embryos were collected at 18 and 46 hours after human chorionic gonadotropin injection, respectively. These were cultured for 120 hours using potassium simplex optimized medium (KSOM) to reach the blastocyst stage. The embryos were randomly allocated into three groups, each cultured in one of three dishes: a 60-mm culture dish, a microdrop dish, and an OIVC dish that we developed. Results: The OIVC dish effectively maintained the osmolarity of the KSOM culture medium over a 5-day period using only 2 mL of mineral oil. This contrasts with the significant osmolarity increase observed in the 60-mm culture dish. Additionally, the OIVC dish exhibited higher blastulation rates from two-cell embryos (100%) relative to the other dish types. Moreover, blastocysts derived from both PN zygotes and two-cell embryos in the OIVC dish group demonstrated significantly elevated mean cell numbers. Conclusion: Use of the OIVC dish markedly increased the number of cells in blastocysts derived from the in vitro culture of preimplantation mouse embryos. The capacity of this dish to maintain medium osmolarity with minimal mineral oil usage represents a breakthrough that may advance embryo culture techniques for various mammals, including human in vitro fertilization and embryo transfer programs.

Comparative analysis of fusion factors affecting the accuracy of injection amount of remote fluid monitoring system (원격 수액모니터링 시스템의 주입량의 정확도에 영향을 주는 융합인자의 비교 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.125-131
    • /
    • 2022
  • Recently, the prevalence of remotely managed patient care systems in medical institutions is increasing due to COVID-19. In particular, in the case of fluid monitoring, hospitals are considering introducing it as a system that can reduce patient safety and nurses' work. There are two products under development: a load cell method that measures weight and a method that detects drops of sap by infrared sensing. Although each product has differences in operation principle, sensor type, size, usage, and price, medical institutions are highly interested in the accuracy of the data obtained.In this study, two prototypes with different sensor methods were manufactured and the total amount of infusion per hour was measured to test the accuracy, which is the core of the infusion monitoring device. In addition, when there was an external movement, the change in the measured value of the sap was tested to evaluate the accuracy according to the measurement method. As a result of the experiment, there was a difference of less than 5% in the measurement value error of the two devices, and the load cell method showed a difference in the low-capacity measurement value and the infrared method in the high-capacity measurement value. As a result of this experiment, there was little difference in accuracy according to the sensor method of the infusion monitoring device, and it is considered that there is no problem in accuracy when used in a medical institution.

Application and Prospects of Molecular Imaging (분자영상의 적용분야 및 전망)

  • Choi, Guyrack;Lee, Sangbock
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.123-136
    • /
    • 2014
  • In this paper, we study to classify molecular imaging and applications to predict future. Molecular imaging in vivo at the cellular level and the molecular level changes taking place to be imaged, that is molecular cell biology and imaging technology combined with the development of the new field. Molecular imaging is used fluorescence, bioluminescence, SPECT, PET, MRI, Ultrasound and other imaging technologies. That is applied to monitoring of gene therapy, cell tracking and monitoring of cell therapy, antibody imaging, drug development, molecular interaction picture, the near-infrared fluorescence imaging of cancer using fluorescence, bacteria using tumor-targeting imaging, therapeutic early assessment, prediction and therapy. The future of molecular imaging would be developed through fused interdisciplinary research and mutual cooperation, which molecular cell biology, genetics, chemistry, physics, computer science, biomedical engineering, nuclear medicine, radiology, clinical medicine, etc. The advent of molecular imaging will be possible to early diagnosis and personalized treatment of disease in the future.

Implementation of a Fragmentation Method for Flow Control in Underwater Multi-media Communication (수중 다중 매체 통신의 흐름제어를 위한 단편화 기법 구현)

  • You, Dongsun;Shin, DongHyun;Lim, Seungsoo;Jeon, Seonghyun;Kim, Changhwa
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.7
    • /
    • pp.819-829
    • /
    • 2020
  • Underwater communication is necessarily useful for various application domains such as saving of human lives from underwater disasters, marine resource exploration, underwater military fields, underwater environment or ecosystem monitoring, fish farm monitoring and management, etc. Even though the acoustic wave has been the main underwater communication media until now, several media such as optical waves, VLF/ELF waves, magnetic fields, and infrared rays also began to be treated as possible media for underwater communication. If these underwater communicate-possible media are used mixing together, the underwater communication can be much more reliable and efficient through complementing the disadvantages of each communication media with advantages of other communication media. In fact, mixing and using multi-media for underwater communication requires the data flow control in the connection process of different media due to their communication speed gaps and bandwidth differences, and, specially, in the flow control, the appropriate message fragmentation technique is required inevitably. For this reason, this paper presents a fragmentation framework and technique necessary to the flow control in the underwater multi-media communication. In addition, through its implementation and experiments, this paper shows the feasibility on the realization of the multi-media based underwater communication.