• Title/Summary/Keyword: biomedical applications

Search Result 762, Processing Time 0.027 seconds

Hydrophobic Coating on Fish Feed Using Dielectric Barrier Discharge Plasma Polymerization (유전체장벽방전 플라즈마 중합을 이용한 양어 사료의 소수성 코팅)

  • Lee, Sang Baek;Hung, Trinhquang;Jo, Jin Oh;Jung, Jun Bum;Im, Tae Heon;Mok, Young Sun
    • Applied Chemistry for Engineering
    • /
    • v.25 no.2
    • /
    • pp.174-180
    • /
    • 2014
  • A plasma hydrophobic coating on commercial fish feed was conducted to prolong the floating time of feed, thereby enhancing the feed consumption rate and reducing the contamination of water in fish farms. The hydrophobic coating on the fish feed was prepared using an atmospheric-pressure dielectric barrier discharge (DBD) plasma with hexamethyldisiloxane (HMDSO), toluene and n-hexane as the precursors. The effect of the parameters such as input power, precursor type and coating time on the coating performance were examined. The physicochemical properties of the coating layer were analyzed using a Fourier transform infrared (FTIR) spectrometer and a contact angle (CA) analyzer. The water CA increased after the coating preparation, indicating that the surface changed from hydrophilic to hydrophobic. The FTIR characterization revealed that the hydrophobic layer was comprised of functional groups such as $CH_3$, Si-O-Si and Si-C. As a result of the hydrophobic coating, the floating time of the fish feed increased from several seconds to 3 minutes, which suggested that the plasma coating method could be a viable means for practical applications. Compared to the water CA measured as soon as the coating layer was prepared, the 6-day aged sample exhibited a substantial CA increase, confirming the aging effect on the improvement of the hydrophobicity.

Preparation and Characterization of Cellulose Nanocrystals Reinforced Poly (vinyl alcohol) Based Hydrogels for Drug Delivery System (약물 전달 시스템 적용을 위한 셀룰로오스 나노크리스탈(CNCs) 강화 Poly(vinyl alcohol) 기반 하이드로겔의 제조 및 특성)

  • CHO, Hyejung;YOO, Won-Jae;AHN, Jinsoo;CHUN, Sang-Jin;LEE, Sun-Young;GWON, Jaegyoung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.431-449
    • /
    • 2020
  • Structural property of most hydrogels is soft, resulting in low mechanical performance that limits their usage in the biomedical applications. For overcoming the drawback, cellulose nanocrystals (CNCs) were adopted in this study. Effects of CNCs on characteristics and drug delivery performance of poly (vinyl alcohol) based hydrogels were explored. FT-IR results showed that the fabricated hydrogels had semi-IPN (semi-interpenetrating polymer network) by formation of acetal and aldehyde bridge. Water absorption and swelling ratio decreased with increasing CNCs content, and the hydrogels with CNCs showed better viscoelastic performance than the without CNCs. Also, CNCs mostly improved the ability of the hydrogel to absorb the drug and the sustainability of the drug release. These results demonstrated that incorporating CNCs into the hydrogel systems can be a good alternative to improve drug delivery performance and mechanical property of the hydrogels.

Clinical Laboratory Aspect of Carbapenem-Resistant Enterobacteriaceae (카바페넴내성장내세균속균종의 임상검사 측면)

  • Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.1
    • /
    • pp.18-27
    • /
    • 2020
  • The correct distinction of carbapenem-resistant Enterobacteriaceae (CRE) and ccarbapenemase producing Enterobacteriaceae (CPE) and the rapid detection of CPE are important for instituting the correct treatment and management of clinical infections. Screening protocols are mainly based on cultures of rectal swab specimens on selective media followed by phenotypic tests to confirm a carbapenem-hydrolyzing activity, the rapid carbapenem inactivation method, lateral flow immunoassay, the matrix-assisted laser desorption ionization-time-of-flight test and molecular methods. The CPE is accurate for detection, and is essential for the clinical treatment and prevention of infections. A variety of phenotypic methods and gene-based methods are available for the rapid detection of carbapenemases, and these are expected to be routinely used in clinical microbiology laboratories. Therefore, to control the spread of carbapenemase, many laboratories around the world will need to use reliable, fast, high efficiency, simple and low cost methods. Optimal effects in patient applications would require rapid testing of CRE to provide reproducible support for antimicrobial management interventions or the treatment by various types of clinicians. For the optimal test method, it is necessary to combine complementary test methods to discriminate between various resistant bacterial species and to discover the genetic diversity of various types of carbapenemase for arriving at the best infection control strategy.

Improved Vapor Recognition in Electronic Nose (E-Nose) System by Using the Time-Profile of Sensor Array Response (센서 응답의 Time-Profile 을 이용한 전자 후각 (E-Nose) 시스템의 Vapor 인식 성능 향상)

  • Yoon Seok, Yang
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.329-334
    • /
    • 2004
  • The electronic nose (E-nose) recently finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. The odor recognition performance of E-nose can be improved by manipulating the sensor array responses of vapors in time-profile forms. The different chemical interactions between the sensor materials and the volatile organic compounds (VOC's) leave unique marks in the signal profiles giving more information than collection of the conventional piecemal features, i.e., maximum sensitivity, signal slopes, rising time. In this study, to use them in vapor recognition task conveniently, a novel time-profile method was proposed, which is adopted from digital image pattern matching. The degrees of matching between 8 different vapors were evaluated by using the proposed method. The test vapors are measured by the silicon-based gas sensor array with 16 CB-polymer composites installed in membrane structure. The results by the proposed method showed clear discrimination of vapor species than by the conventional method.

Surface Reaction Products of CP- Ti and Ti-25wt%Pd Castings Used for Dental Application (치과용 티타늄 및 Ti-25wt%Pd 주조체의 표면반응생성물)

  • 정준영;문수;이진형
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.383-389
    • /
    • 2004
  • A commercially pure Ti(CP-Ti) and Ti-25wt%Pd alloy for dental applications were cast into a phosphate-bonded Al$_2$ $O_3$/ $SiO_2$ investment mold and the surface of the casting specimens were investigated by means of SEM/EDS, XRD and XPS. The addition of 25wt%Pd in CP-Ti showed a moderate mold reaction owing to the considerable lowering of melting point. XRD analysis of the investment after burn-out treatment revealed that it consisted essentially of $SiO_2$, Al$_2$ $O_3$, P$_2$O$\_$5/, Mg$_3$(P $O_4$)$_2$, AlP $O_4$, Mg$_2$ $SiO_4$, MgAl$_2$ $O_4$ The mold reaction products were Ti$\_$5/Si$_3$ and Ti $O_2$ in case of CP-Ti casting and Ti $O_2$ and SiO$\_$x/ in case of Ti-25wt% Pd casting.

Synthesis of Homing Peptide-Immobilized Magnetite Nanoparticles through PEG Spacer and Their Biomedical Applications (PEG 스페이서를 통해 Homing 펩타이드를 고정화한 산화철 나노입자의 제조 및 생의학적 응용)

  • Lee, Sang-Min;Xing, Zhi-Cai;Shin, Yong-Suk;Gu, Tae-Hyung;Lee, Byung-Heon;Huh, Man-Woo;Kang, Inn-Kyu
    • Polymer(Korea)
    • /
    • v.36 no.5
    • /
    • pp.586-592
    • /
    • 2012
  • Iron oxides ($Fe_3O_4$) are metabolically secreted after endocytosed by cells, indicating no cytotoxicity. Therefore, they are widely used as a contrast agent before photographing of magnetic resonance imaging. In this study, iron oxide nanoparticles are synthesized by the co-precipitation method and subsequently immobilized with a homing peptide (AP), which specifically interacts with interleukin-4 receptor located on the membrane of endothelial and bladder cancer cells. The size of AP-immobilized iron oxide particle is about 39 nm. Intracellular uptake of the AP-immobilized iron oxide nanoparticles was investigated using bladder cancer cells and fibroblasts as the control. As the result, the nanoparticles are specificially uptaken by bladder cancer cells. However, the nanoparticles are not specificially uptaken by fibroblast. It could be said that the AP-immobilized iron oxide nanoparticles have a potential to be used as a contrast agent for early diagnosis of cancer.

Preparation of Chitosan-coated Magnetite Nanoparticles (키토산이 피복된 나노 크기의 자성체 분말 제조)

  • Cho, Jun-Hee;Ko, Sang-Gil;Ahn, Yang-Kyu;Song, Ki-Chang;Choi, Eun-Jung
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.1
    • /
    • pp.102-106
    • /
    • 2006
  • Magnetic nanoparticles can be used for a variety of biomedical applications. They can be used in the targeted delivery of therapeutic agents in vivo, in the hyperthermic treatment of cancers. in magnetic resonance (MR) imaging as contrast agents and in the biomagnetic separations of biomolecules. We have synthesized magnetite $(Fe_3O_4)$ nanoparticles using chemical coprecipitation technique with sodium oleate as surfactant. Nanoparticle size can be varied from 2 to 8nm by controlling the sodium oleate concentration. Magnetite phase nanoparticles could be observed from X-ray diffraction. Magnetic colloid suspensions containing particles with sodium oleate and chitosan have been prepared. Nanoparticles, both oleate-coated and chitosan-coated, have been characterized by several techniques. Atomic farce microscope (AFM) was used to image the coated nanoparticles. Magnetic hysteresis measurement were performed using a superconducting quantum interference device (SQUID) magnetometer at room temperature to investigate the magnetic properties of the magnetite nanoparticles. The SQUID measurements revealed superparamagnetism of nanoparticles.

Evaluation of MR-SENSE Reconstruction by Filtering Effect and Spatial Resolution of the Sensitivity Map for the Simulation-Based Linear Coil Array (선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가)

  • Lee, D.H.;Hong, C.P.;Han, B.S.;Kim, H.J.;Suh, J.J.;Kim, S.H.;Lee, C.H.;Lee, M.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.245-250
    • /
    • 2011
  • Parallel imaging technique can provide several advantages for a multitude of MRI applications. Especially, in SENSE technique, sensitivity maps were always required in order to determine the reconstruction matrix, therefore, a number of difference approaches using sensitivity information from coils have been demonstrated to improve of image quality. Moreover, many filtering methods were proposed such as adaptive matched filter and nonlinear diffusion technique to optimize the suppression of background noise and to improve of image quality. In this study, we performed SENSE reconstruction using computer simulations to confirm the most suitable method for the feasibility of filtering effect and according to changing order of polynomial fit that were applied on variation of spatial resolution of sensitivity map. The image was obtained at 0.32T(Magfinder II, Genpia, Korea) MRI system using spin-echo pulse sequence(TR/TE = 500/20 ms, FOV = 300 mm, matrix = $128{\times}128$, thickness = 8 mm). For the simulation, obtained image was multiplied with four linear-array coil sensitivities which were formed of 2D-gaussian distribution and the image was complex white gaussian noise was added. Image processing was separated to apply two methods which were polynomial fitting and filtering according to spatial resolution of sensitivity map and each coil image was subsampled corresponding to reduction factor(r-factor) of 2 and 4. The results were compared to mean value of geomety factor(g-factor) and artifact power(AP) according to r-factor 2 and 4. Our results were represented while changing of spatial resolution of sensitivity map and r-factor, polynomial fit methods were represented the better results compared with general filtering methods. Although our result had limitation of computer simulation study instead of applying to experiment and coil geometric array such as linear, our method may be useful for determination of optimal sensitivity map in a linear coil array.

Machine-Learning Based Biomedical Term Recognition (기계학습에 기반한 생의학분야 전문용어의 자동인식)

  • Oh Jong-Hoon;Choi Key-Sun
    • Journal of KIISE:Software and Applications
    • /
    • v.33 no.8
    • /
    • pp.718-729
    • /
    • 2006
  • There has been increasing interest in automatic term recognition (ATR), which recognizes technical terms for given domain specific texts. ATR is composed of 'term extraction', which extracts candidates of technical terms and 'term selection' which decides whether terms in a term list derived from 'term extraction' are technical terms or not. 'term selection' is a process to rank a term list depending on features of technical term and to find the boundary between technical term and general term. The previous works just use statistical features of terms for 'term selection'. However, there are limitations on effectively selecting technical terms among a term list using the statistical feature. The objective of this paper is to find effective features for 'term selection' by considering various aspects of technical terms. In order to solve the ranking problem, we derive various features of technical terms and combine the features using machine-learning algorithms. For solving the boundary finding problem, we define it as a binary classification problem which classifies a term in a term list into technical term and general term. Experiments show that our method records 78-86% precision and 87%-90% recall in boundary finding, and 89%-92% 11-point precision in ranking. Moreover, our method shows higher performance than the previous work's about 26% in maximum.

Analysis on Muscle Activities in the Upper Body of Caregivers according to Drive-Assisting Speeds of a Shower Carrier

  • Ko, Cheol Woong;Cho, Deok Yeon;Bae, Tae Soo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.5
    • /
    • pp.437-442
    • /
    • 2013
  • Objective: The objective of this study was to investigate the effects of drive-assisting system in a shower carrier on the upper body muscle activities of caregivers through drivability tests. Background: In care facilities, one of the major ADL (Activities of Daily Living) factors is bathing/showering. Recently, bath/shower-assisting equipment is actively being introduced in care facilities to reduce caregivers' muscle burden. In particular, it is desirable to utilize a shower carrier equipped with drive-assisting system to effectively care for the elderly. However, there were few systematic studies on the relationship between muscle activities and drive-assisting speeds. Method: For the drivability tests to study the effects on the muscle activities according to the drive-assisting speeds(corresponding drive-voltages: 0.0V, 2.0V, 2.1V, 2.3V), 6 females in their 40s($43{\pm}4yrs$, $157{\pm}5cm$, and $54.5{\pm}1.5kg$) were selected. To measure muscle activities of caregivers through drivability tests, 7 muscles in the upper body(TM/Trapezius Muscle, DM/Deltoid Muscle, BBM/Biceps Brachii Muscle, TBM/Triceps Brachii Muscle, ECRLM/Extensor Carpi Radialis Longus Muscle, FCUM/Flexor Carpi Ulnaris Muscle, and ESM/Erector Spinae Muscle) were selected. Results: In the TM, muscle activities were decreased as 21% compared to 0.0V, when drive-voltage 2.0V was applied, as 57% by 2.1V, and 62% by 2.3V(p<0.05), whereas 40%, 56%, and 69% of muscles activities were decreased respectively from the DM(p<0.05). Also, from the UL(BBM+TBM+ECRLM+FCUM), muscle activities were decreased by 17% with 2.0V as against 0.0V, by 47% with 2.1V, and 52% with 2.3V, whereas decreases in muscle activities from the ESM were found by 20%, 34%, and 42% respectively by 2.0V, 2.1V, and 2.3V(p<0.05). Conclusion: The muscle activities were decreased in the order of the DM, TM, ESM, and UL. As muscle activities were remarkably reduced as drive voltage were increased, it was expected to reduce the upper body muscle burden on the caregivers when using shower carriers equipped with driving-assist system. Applications: The results from this study can be applied for the development of a shower carrier including other equipment to possibly reduce the muscle burden of the caregivers.