• Title/Summary/Keyword: biomedical application

Search Result 862, Processing Time 0.03 seconds

Sequential Pituitary Hormone Responses to Electroconvulsive Therapy (전기경련요법후 뇌하수체 호르몬의 순차적인 분비 반응)

  • Kim, Doh Kwan;Kim, Soo Jeong;Choi, Do Sun;Bok, Hae-Sook;Kim, Seungtai Peter
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.288-294
    • /
    • 1996
  • Background : Most studies of the pituitary hormonal responses to electroconvulsive therapy(ECT) have used limited blood sampling schedules. Little is known about the precise sequence of neuroendocrine events immediately following en ECT application. or about the regulation of the hormonal responses. Methods : Blood was sampled at three minute intervals from eleven patients(two schizophrenics and nine affective disorder patients) undergoing ECT. Each sample was immunologically assayed for arginine vasopressin(AVP), adrenocorticotropic hormone(ACTH), prolactin(PRL), and cortisol. Baseline hormone concentrations and several measures of response were determined for each hormone. The temporal and quantitative relationships among the hormonal responses were determined. Correlations were calculated between seizure duration and secretory responses. Results : All four hormones demonstrated significant secretory responses to ECT, with AVP increasing from 1.2 to 33.3pg/ml(P<0.001), ACTH from 5.4 to 32.3fmol/ml(P<0001). PRL from 21.8 to 102.2ng/ml(P<0.005) and cortisol from 20.1 to 31.1ug/dl(P<0.001). The three pituitary hormones showed consistent time courses of secretion with onset of responses by three minutes but clearly differing peak times of 3, 6, and 12-15 minutes for AVP, ACTH, and PRL, respectively. Cortisol began to rise after 6minutes and pecked between 20-30minutes. There ware no significant correlations between seizure duration and any of the secretory response measures. Conclusions : 1) The pituitary hormone response to ECT is sequential rather than synchronous 2) The AVP response was extremely rapid and more massive than those of any other hormones. 3) The ACTH response of this study was more rapid and mare robust than thai revealed by the mast of past studies. 4) The results strongly suggest that the pituitary hormones are released as a result of the seizure rather tho, the electrical stimulus. 5) The sequential pattern of responses suggests that neuroendocine feedback-regulatory mechanisms determine the response profile.

  • PDF

Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images (CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The purpose of this study is to develop a practical method for determining accurate marker positions for prostate cancer radiotherapy using CT images and kV x-ray images obtained from the use of the on- board imager (OBI). $\underline{Materials\;and\;Methods}$: Three gold seed markers were implanted into the reference position inside a prostate gland by a urologist. Multiple digital image processing techniques were used to determine seed marker position and the center-of-mass (COM) technique was employed to determine a representative reference seed marker position. A setup discrepancy can be estimated by comparing a computed $COM_{OBI}$ with the reference $COM_{CT}$. A proposed algorithm was applied to a seed phantom and to four prostate cancer patients with seed implants treated in our clinic. $\underline{Results}$: In the phantom study, the calculated $COM_{CT}$ and $COM_{OBI}$ agreed with $COM_{actual}$ within a millimeter. The algorithm also could localize each seed marker correctly and calculated $COM_{CT}$ and $COM_{OBI}$ for all CT and kV x-ray image sets, respectively. Discrepancies of setup errors between 2D-2D matching results using the OBI application and results using the proposed algorithm were less than one millimeter for each axis. The setup error of each patient was in the range of $0.1{\pm}2.7{\sim}1.8{\pm}6.6\;mm$ in the AP direction, $0.8{\pm}1.6{\sim}2.0{\pm}2.7\;mm$ in the SI direction and $-0.9{\pm}1.5{\sim}2.8{\pm}3.0\;mm$ in the lateral direction, even though the setup error was quite patient dependent. $\underline{Conclusion}$: As it took less than 10 seconds to evaluate a setup discrepancy, it can be helpful to reduce the setup correction time while minimizing subjective factors that may be user dependent. However, the on-line correction process should be integrated into the treatment machine control system for a more reliable procedure.

Clinical Application of in Vivo Dosimetry System in Radiotherapy of Pelvis (골반부 방사선 치료 환자에서 in vivo 선량측정시스템의 임상적용)

  • Kim, Bo-Kyung;Chie, Eui-Kyu;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 2002
  • The accuracy of radiation dose delivery to target volume is one of the most important factors for good local control and less treatment complication. In vivo dosimetry is an essential QA procedure to confirm the radiation dose delivered to the patients. Transmission dose measurement is a useful method of in vivo dosimetry and it's advantages are non-invasiveness, simplicity and no additional efforts needed for dosimetry. In our department, in vivo dosimetry system using measurement of transmission dose was manufactured and algorithms for estimation of transmission dose were developed and tested with phantom in various conditions successfully. This system was applied in clinic to test stability, reproducibility and applicability to daily treatment and the accuracy of the algorithm. Transmission dose measurement was performed over three weeks. To test the reproducibility of this system, X-tay output was measured before daily treatment and then every hour during treatment time in reference condition(field size; $10 cm{\times} 10 cm$, 100 MU). Data of 11 patients whose pelvis were treated more than three times were analyzed. The reproducibility of the dosimetry system was acceptable with variations of measurement during each day and over 3 week period within ${\pm}2.0%$. On anterior- posterior and posterior fields, mean errors were between -5.20% and +2.20% without bone correction and between -0.62% and +3.32% with bone correction. On right and left lateral fields, mean errors were between -10.80% and +3.46% without bone correction and between -0.55% and +3.50% with bone correction. As the results, we could confirm the reproducibility and stability of our dosimetry system and its applicability in daily radiation treatment. We could also find that inhomogeneity correction for bone is essential and the estimated transmission doses are relatively accurate.

Tissue Engineered Cartilage Formation on Various PLGA Scaffolds (PLGA 종류와 담체의 형성 방법에 따른 인간의 조직공학적 연골형성)

  • 김유미;임종옥;정호윤;박태인;백운이
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.147-153
    • /
    • 2002
  • The purpose of this study was to evacuate the effect of different types of Poly(lactic-co-glycolic acid) (PLGA) scaffolds on the formation of human auricular and septal cartilages. All of the scaffolds were formed in a tubular shape for potential application for artificial trachea or esophagus with either 110,000 g/mol PLGA. 220,000 g/mol PLGA. or a combination of both. In order to maintain the tubular shape in vivo, two methods were used. One method was inserting polyethylene tube at the center of scaffolds made of 110,000 g/mol PLGA. The other method involved combination of the two different molecular weight PLGA's. The inner surface of tubular shaped scaffold made with 110,000 g/mol PLGA was coated with 220,000 9/mol PLGA to give more mechanical rigidity. Elastic cartilage was taken from the ear of a patient aged under 20 nears old and hyaline cartilage was taken from the nasal septum. The chondrocytes were then isolated. After second passage, the chondrocytes were seeded on the PLGA scaffolds followed by in vitro culture for one week. The cells-PLGA scaffold complex were implanted subcutaneously on the back of nude mice for 8 weeks. The tissue engineered cartilages were separated from nude mice and examined histologically after staining with the Hematoxylin Eosin. The morphology of the scaffolds were examined by scanning electron microscopy. The pores were well formed and uniformly distributed in the various PLGA scaffolds. After 8 weeks in vivo culture, cartilage was well formed with 110,000 g/mol PLGA. however lumen had collapsed. In contrast. a minimal amount of neocartilage was formed with 220,000 g/mol PLGA, while the architecture of scaffold and lumen were well preserved. Elastic cartilage formed more neocartilage than hyaline. Hyaline and elastic neocartilage were well formed on 110,000 g/mol PLGA with the polyethylene tube, exhibiting mature chondrocytes and preservation of the tubular shape. It was found that 110,000 g/mol PLGA was more appropriate for cartilage formation but higher molecular weight polymer was necessary to maintain the three dimensional shape of the scaffold.

Influence of Delayed Gastric Emptying in Radiotherapy after a Subtotal Gastrectomy (위부분절제술 후 방사선치료에서 음식물 배출지연에 따른 영향)

  • Kim, Dong-Hyun;Kim, Won-Taek;Lee, Mi-Ran;Ki, Yong-Gan;Nam, Ji-Ho;Park, Dal;Jeon, Ho-Sang;Jeon, Kye-Rok;Kim, Dong-Won
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.194-200
    • /
    • 2009
  • Purpose: This aim of this study was to evaluate changes in gastric volume and organ position as a result of delayed gastric emptying after a subtotal gastrectomy performed as part of the treatment of stomach cancer. Materials and Methods: The medical records of 32 patients who underwent concurrent chemoradiotherapy after a subtotal gastrectomy from March 2005 to December 2008 were reviewed. Of these, 5 patients that had more than 50 cc of residual gastric food detected at computed tomography (CT) simulation, were retrospectively enrolled in this study. Gastric volume and organ location was measured from CT images obtained before radiotherapy, twice weekly. In addition, authors evaluated the change of radiation dose distribution to planning the target volume and normal organ in a constant radiation therapy plan regardless of gastric volume variation. Results: A variation in the gastric volume was observed during the radiotherapy period (64.2~340.8 cc; mean, 188.2 cc). According to the change in gastric volume, the location of the left kidney was shifted up to 0.7 - 2.2 cm (mean, 1.2 cm) in the z-axis. Under-dose to planning target volume (V43, 79.5${\pm}$10.4%) and over-dose to left kidney (V20, 34.1${\pm}$12.1%; Mean dose, 23.5${\pm}$8.3 Gy) was expected, given that gastric volume change due to delayed gastric emptying wasn't taken into account. Conclusion: This study has shown that a great change in gastric volume and left kidney location may occur during the radiation therapy period following a subtotal gastrectomy, as a result of delayed gastric emptying. Detection of patients who experienced delayed gastric emptying and the application of gastric volume variation to radiation therapy planning will be very important.

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.

Fertilizing Effects of Swine Compost Fermented with Sawdust on Mixed Pastures (혼파초지에 대한 톱밥발효돈분의 시용효과)

  • Shin, J. Soon;Cho, Young-Mu;Lee, Hyo-Ho;Yoon, Sea-Hung;Park, Geun-Je;Choi, Ki-Chun
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.24 no.3
    • /
    • pp.245-252
    • /
    • 2004
  • Experiment was carried out to find the fertilizing effects of 8 different application rates of swine compost fermented with sawdust(SCS) including Chemical fertilizer(CF) on forage yield and soil chemical characteristics of mixed pastures sown in Sep. 1993 at National Livestock Research Institute, RDA., in Suwon during low years. It was arranged in a randomized complete block design with three replicates. Dry matter yield were shown at similar among treatments except Control and $50\%$ SCS of standard amount plot. In botanical composition, the legume and weeds percentages of each treatment were increased as advancing year. The final year's legume percentage were high in line with SCS fertilizing plots($39\%{\sim}43\%$), SCS + CF plots($30\%{\sim}41\%$) and CF plot($32\%$). In productions of TDN, NE and crude protein yield, SCS or SCS($75\%$) + CF($25\%$) were nearly same comparing those of CF, respectively. Phosphate, potassium, magnesium contents and K/(Ca + Mg) except calcium contents of those SCS fertilizing plots in plant were generally high with comparing CF. Those contents were proportional according to the fertilizing amount These result indicate the possibility to substitute chemical fertilizer for SCS($75\%$, 25ton/ha) + CF, $25\%$) as manure-N 210 kg/ha, but might be considered accumulation phosphate in the soil.

Effects of Coculture on Development of Biopsied Mouse Embryos as a Preclinical Model for Preimplantation Genetic Diagnosis of Human Embryos (생쥐 모델을 이용한 배아의 할구 생검법과 할구가 생검된 배아의 배양시 공배양 효과에 관한 연구: 인간에서의 착상 전 유전진단 기술 개발을 위한 동물실험 모델의 개발)

  • Kim, S.H.;Ryu, B.Y.;Jee, B.C.;Choi, S.M.;Kim, H.S.;Pang, M.G.;Oh, S.K.;Suh, C.S.;Choi, Y.M.;Kim, J.G.;Moon, S.Y.;Lee, J.Y.;Chae, H.D.;Kim, C.H.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.1
    • /
    • pp.9-20
    • /
    • 1999
  • The genetic defects in human gametes and embryos can cause adverse effects on overall reproductive events. Biopsy of embryos for preimplantation genetic diagnosis (PGD) offers a new possibility of having children free of the genetic disease. In addition, advanced embryo culture method may enhance the effectiveness of embryo biopsy for the practical application of PGD. This experimental study was undertaken to evaluate the effects of coculture on the development in vitro of biopsied mouse embryos as a preclinical model for PGD of human embryos. Embryos were obtained after in vitro fertilization (IVF) from F1 hybrid mice (C57BLfemale/CBAmale). Using micromanipulation, 1, 2, 3 or 4 blastomeres of 8-cell stage embryos were aspirated through a hole made in the zona pellucida by zona drilling (ZD) with acidic Tyrode's solution (ATS). After biopsy of blastomeres, embryos were cultured in vitro for 110 hours in Ham's F-10 supplemented with 0.4% BSA or cocultured on the monolayer of Vero cells in the same medium. The frequence of blastocyst formation were recorded, and the embryos beyond blastocyst stage were stained with 10% Giemsa to count the total number of nuclei in each embryo. There was no significant difference in the blastocyst formation between the zona intact control group and the zona drilling (ZD) only, or biopsied groups. The hatching rate of all the treatment groups except 4/8 group was significantly higher than that of control group. In all the treatment groups, there was a significant reduction in the mean cell number of embryos beyond blastocyst stage ($50.2{\pm}14.0$ in control group vs. $41.2{\pm}7.9$ in ZD, $39.3{\pm}8.8$ in 7/8, $29.7{\pm}6.4$ in 6/8, $25.1{\pm}5.7$ in 5/8, and $22.1{\pm}4.3$ in 4/8 groups, p<0.05). When the same treatments were followed by coculture with Vero cells, a similar pattern was seen in the blastocyst formation and the hatching rate. However, in all the treatment groups, there was a significant increase in the mean cell number of embryos beyond blastocyst stage with coculture, compared with the parallel groups without coculture. In the cleavage rate of biopsied blastomeres cultured for 110 hours after IVF, there was no significant difference between coculture and non-coculture groups (87.2% vs. 78.7%). However, the mean cell number of embryos developed from the biopsied blastomeres was significantly higher in coculture group ($11.5{\pm}4.7\;vs.\;5.9{\pm}1.9$, p<0.05). In conclusion, biopsy of mouse embryos after ZD with ATS is a safe and highly efficient method for PGD, and coculture with Vero cells showed a positive effect on the development in vitro of biopsied mouse embryos and blastomeres as a preclinical model for PGD of human embryos.

  • PDF

Preparation of Novel Natural Polymer-based Magnetic Hydrogels Reinforced with Hyperbranched Polyglycerol (HPG) Responsible for Enhanced Mechanical Properties (과분지 폴리글리세롤(HPG) 강화를 통해 기계적 물성이 향상된 새로운 천연 고분자 기반 자성 하이드로젤의 제조)

  • Eun-Hye Jang;Jisu Jang;Sehyun Kwon;Jeon-Hyun Park;Yujeong Jeong;Sungwook Chung
    • Clean Technology
    • /
    • v.29 no.1
    • /
    • pp.10-21
    • /
    • 2023
  • Hydrogels that are made of natural polymer-based double networks have excellent biocompatibility, low cytotoxicity, and high water content, assuring that the material has the properties required for a variety of biomedical applications. However, hydrogels also have limitations due to their relatively weak mechanical properties. In this study, hydrogels based on an alginate di-aldehyde (ADA) and gelatin (Gel) double network that is reinforced with additional hydrogen bonds formed between the hydroxyl (-OH) groups of the hyperbranched polymer (HPG) and the functional groups present inside of the hydrogels were successfully synthesized. The enhanced mechanical properties of these synthesized hydrogels were evaluated by varying the amount of HPG added during the hydrogel synthesis from 0 to 25%. In addition, magnetite nanoparticles (Fe3O4 NPs) were synthesized within the hydrogels and the structures and the magnetic properties of the hydrogels were also characterized. The hydrogels that contained 15% HPG and Fe3O4 NPs exhibited superparamagnetic behaviors with a saturation magnetization value of 3.8 emu g-1. These particular hydrogels also had strengthened mechanical properties with a maximum compressive stress of 1.1 MPa at a strain of 67.4%. Magnetic hydrogels made with natural polymer-based double networks provide improved mechanical properties and have a significant potential for drug delivery and biomaterial application.

Multi-classification of Osteoporosis Grading Stages Using Abdominal Computed Tomography with Clinical Variables : Application of Deep Learning with a Convolutional Neural Network (멀티 모달리티 데이터 활용을 통한 골다공증 단계 다중 분류 시스템 개발: 합성곱 신경망 기반의 딥러닝 적용)

  • Tae Jun Ha;Hee Sang Kim;Seong Uk Kang;DooHee Lee;Woo Jin Kim;Ki Won Moon;Hyun-Soo Choi;Jeong Hyun Kim;Yoon Kim;So Hyeon Bak;Sang Won Park
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.187-201
    • /
    • 2024
  • Osteoporosis is a major health issue globally, often remaining undetected until a fracture occurs. To facilitate early detection, deep learning (DL) models were developed to classify osteoporosis using abdominal computed tomography (CT) scans. This study was conducted using retrospectively collected data from 3,012 contrast-enhanced abdominal CT scans. The DL models developed in this study were constructed for using image data, demographic/clinical information, and multi-modality data, respectively. Patients were categorized into the normal, osteopenia, and osteoporosis groups based on their T-scores, obtained from dual-energy X-ray absorptiometry, into normal, osteopenia, and osteoporosis groups. The models showed high accuracy and effectiveness, with the combined data model performing the best, achieving an area under the receiver operating characteristic curve of 0.94 and an accuracy of 0.80. The image-based model also performed well, while the demographic data model had lower accuracy and effectiveness. In addition, the DL model was interpreted by gradient-weighted class activation mapping (Grad-CAM) to highlight clinically relevant features in the images, revealing the femoral neck as a common site for fractures. The study shows that DL can accurately identify osteoporosis stages from clinical data, indicating the potential of abdominal CT scans in early osteoporosis detection and reducing fracture risks with prompt treatment.