• 제목/요약/키워드: bi-directional current switch

검색결과 13건 처리시간 0.023초

ZVT 스위칭 되는 전류제어형 양방향 인버터의 구현 (An Implementation of a Current Controlled Bi-directional Inverter with ZVT Switching)

  • 이성룡;고성훈;김성우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.149-152
    • /
    • 2001
  • A Single-phase bi-directional inverter Using a diode bridge-type resonant circuit to implement ZVT(Zero Voltage Transition) switching is Presented. It is shown that the ZACE(Zero Average Current Error) algorithm based polarized ramptime current control can provide a suitable interface between diode bridge-type resonant circuit DC link and the inverter. The current control algorithm is analyzed about how to design the circuit with analyzed switch which m ZVT operation for the main power switch The simulation and experimental results would be shown to verify the proposed current algorithm, because the main power switch is turn on with ZVT and the bi-directional inverter is operated.

  • PDF

A New Current Controlled Inverter with ZVT Switching

  • Lee S. R.;Jeon C. H.;Ko S. H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.309-313
    • /
    • 2001
  • A single-phase bi-directional inverter with a diode bridge-type resonant circuit to implement ZVT(Zero Voltage Transition) switching is proposed. It is shown that the polarized ramptime current control algorithm, a method that belongs to the family of ZACE(Zero Average Current Error) methods, is a suitable technique to integrate with a typical single-phase ZVT inverter. The proposed current control algorithm is analyzed to design the circuit with auxiliary switch which can operate with ZVT for the main power switch. The simulation results would be shown to verify the proposed current algorithm to turn the main power switch on with ZVT and to operate the inverter bi-directionally

  • PDF

직류링크 전류를 이용한 인터리브드 양방향 컨버터의 상전류 불균형 보상 방법 (Compensation of Unbalanced Phase Currents in Interleaved Bi-directional Converter with DC Link Current Sensed)

  • 한정호;최유현;송중호
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.90-97
    • /
    • 2014
  • This paper presents a compensation method of unbalanced phase currents in interleaved bi-directional converters. Phase currents in interleaved bi-directional converter are apt to be unbalanced due to circuit parameter error and switch operation difference. This problem causes the switch element failure and the reduced efficiency of the converter. Therefore, it is necessary that a certain balance control algorithm is provided in interleaved bi-directional converter system. In this paper, a balance control algorithm based on the circular chain control method is proposed. Further, in order to reduce the number of phase current sensors, this paper shows a simple method in which phase currents can be extracted indirectly through a DC-link current sensor in both charging and discharging modes. The validity and the effectiveness of the proposed phase currents balance control algorithm are illustrated through the simulation results.

양방향 부분공진 소프트 스위칭을 적용한 AC-DC컨버터의 설계 (A Design of AC-DC Converter using Bi-directional Partial Resonant Soft-Switching)

  • 윤상훈;고강훈;서기영;권순걸;이현우;이철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1023-1025
    • /
    • 2001
  • This paper proposes a bi-directional current switch with snubber regeneration using Power MOSFETs and this paper proposes to use a loss-less snubber with switching device to perform soft-switching. It results in not only decreasing switching loss in the device drastically, but also improving input ac current waveform distortion. The computer simulation results show that the input current waveform and show the requirements necessary for the elimination of the 3rd harmonic component. We also show the procedure to design the parameters of the converter.

  • PDF

양방향 Buck 컨버터 DCM 구동을 위한 설계 및 전류링잉현상에 따른 스위치 및 다이오드 선정에 관한 연구 (A Study on the Design and Selection of Switch and Diode by Analyzing Current Ringing on DCM Bi-directional Buck Converter)

  • 이영달;최규영;신승민;이병국;이태원
    • 전력전자학회논문지
    • /
    • 제17권1호
    • /
    • pp.14-20
    • /
    • 2012
  • This paper presents a design and topology selection of bi-direcional buck converter based on PV PCS for managing the electric power. Futhermore, Current Ringing on DCM bi-directional buck converter for soft switching is analyzed in detail. PSIM Simulation and Experiments at the various operating points show the propriety of this paper. Building on the result of simulation and experiment, a comparative analysis is performed with the approximate estimate. By use of a study, the selecion of switch and diode which improve efficiency of the overall system is appiled to DCM bi-directional buck converter based on PV PCS.

양방향 부분공진 소프트 스위칭을 적용한 컨버터 회로 설계 (A Design of Converter using Bi-directional Partial Resonant Soft-Switching)

  • 윤상훈;김천식;서기영;이현우;김광태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.212-214
    • /
    • 2001
  • This paper proposes a hi-directional current switch with snubber regeneration using Power MOSFETs and to use a loss-less snubber with switching device to perform soft-switching. It results in not only decreasing switching loss in the device drastically, but also improving input ac current waveform distortion. The computer simulation results show that the input current waveform and show the requirements necessary for the elimination of the 3rd harmonic component. We also show the Procedure to design the parameters of the converter.

  • PDF

연료전지·이차전지 하이브리드 시스템을 위한 인터리빙 양방향 DC-DC 컨버터 설계 (The Design of Interleaved Bi-directional DC-DC Converter for Fuel Cell and Battery Hybrid System)

  • 김승민;최주엽;최익;송승호;이상철;이동하
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.45-53
    • /
    • 2013
  • Fuel cell power system is one of the most promising energy source for the alternative energy because it has unique advantages such as high energy density, no power drop during operation, and feasible to make compact size. However, due to very low response time, fuel cell is difficult to correspond to drastic load changes and start-up operation. For solving these problem, fuel cell power system must include energy storage device such as Li-Poly battery or super capacitor. Therefore, bi-directional DC-DC converter must be required for this storage device and fuel cell-PCS control. This paper presents a design and modeling of the bi-directional DC/DC converter. Firstly, we present modeling the boost and buck mode of the bi-directional converter through both PWM switch model and state space averaging technique. Secondly, in order to minimize output ripple and transient response overshoot, we have two identical DC-DC converters interleaved and adopt two-loop voltage-current controller. The proposed bi-directional DC-DC converter's modeling method and control design have been verified with computer simulation and experimentation.

ZVT 스위칭 되는 전류제어형 양방향 인버터의 구현 (An Implementation of a Current Controlled Bi-directional Inverter with ZVT Switching)

  • 李 星 龍;高 晟 勳;金 成 佑
    • 전력전자학회논문지
    • /
    • 제7권2호
    • /
    • pp.129-136
    • /
    • 2002
  • 최근에 전력계통의 안정 및 고품질화에 대한 요구가 증대되기 시작하였고, 이에 따라 향상된 전력변환기술과 대체에너지원을 이용한 계통연계형 시스템에 대한 연구가 활발히 진행되고 있다 이러한 시스템에서의 인버터의 효율은 매우 중요하다. 따라서 본 논문에서는 이러한 계통연계형 시스템을 고효율화 하기 위한 방법으로 소프트-스위칭 기법이 적용 가능한 전류제어형 인버터를 제안하였다. 또한, 소프트-스위칭 기법을 적용할 수 있는 전류제어 알고리즘과 ZVT 동작원리를 이론적으로 해석하였고 이의 유용성을 시뮬레이션과 실험을 통하여 입증하였다.

ZVT 스위칭 되는 새로운 전류제어형 인버터 (A New Current Controlled Inverter with ZVT Switching)

  • 이성룡;고성훈;김성우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.323-326
    • /
    • 2001
  • In this paper, the proposed current control algorithm is analized and discussed about how to design the auxiliary circuit with auxiliary switch which can apply ZVT operation for the main switch. The simulation results would be shown to verify the proposed current algorithm, because the main power switch is turn on with ZVT and the bi-directional Inverter is operated.

  • PDF

양방향 Buck 컨버터 DCM 구동 시 전류링잉현상 분석에 따른 스위치 및 다이오드 선정 (Selection of Switch and Diode by Analyzing Current Ringing on DCM Bi-directional Buck Converter)

  • 이영달;최규영;신승민;이병국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.169-170
    • /
    • 2011
  • 본 논문은 양방향 Buck 컨버터 DCM 구동 시 사용되는 스위치의 전류링잉현상을 상세히 분석하고 이에 따른 스위치 효율과 시스템 전력 효율 차이를 실험을 통해 검증한다. 분석을 통해 얻은 결과를 바탕으로 양방향 Buck 컨버터 설계 시 전력 효율을 높이는 스위치 및 다이오드를 선정하였다.

  • PDF