• Title/Summary/Keyword: best section

Search Result 361, Processing Time 0.026 seconds

A study of Developing Torso Master Pattern Using 3D body Measurement Data - Focusing on Women in their thirties proper Body Types - (3차원 인체형상자료를 활용한 토르소 마스터패턴 개발 - 30대 바른 체형 여성을 대상으로 -)

  • Shin, Ju-Young Annie;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.17 no.3
    • /
    • pp.447-461
    • /
    • 2015
  • The purpose of this study is to develop a torso pattern that is highly representative for the proper body shape of women in their thirties. Size data of the women with age of 30 through 39 from the database of Size Korea 2004 were used for the study. In order to develop a master pattern which will be used as the benchmark for grading of research group, 4 existing torso block drafting methods were compared based on the data gathered and the block with the highest evaluation score was utilized as a reference point. For the analysis, data was divided into four types, only the data of 138 subjects which were evaluated at least by four or more experts as valid were used for the study. The major results can be summarized as follow. The women of bust girth of 91cm and height of 160cm which was turned out to be representative type of research group were used as standard measurement for the purpose of reflecting not only curve length of the 3D analysis measurement but also the difference between front and back thickness to the pattern. Dart locations were set based on front and back torso ease, shoulder area revisions, front sagging length 1.5cm and cross section crevice length analysis. According to the experts' appearance evaluation of the pattern was found to be better than the control pattern which was regarded as the best among 4 patterns created based on existing torso block drafting methods.

A Study on the Improvement of the Condensation Heat Transfer Performance of the Helical Grooved and Plain Thermosyphons (나선 그루브와 평관형 열사이폰의 응축열전달 성능 향상에 관한 연구)

  • Han, K.I.;Park, J.U.;Cho, D.H.
    • Journal of Power System Engineering
    • /
    • v.10 no.2
    • /
    • pp.47-53
    • /
    • 2006
  • This study concerns the performance of condensation heat transfer in plain and grooved thermosyphons. Distilled water, methanol, ethanol have been used as the working fluids. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A study was carried out with the characteristics of heat transfer of the thermosyphon 50, 60, 70, 80, 90 helical grooves in which boiling and condensation occur. The liquid filling as the ratio of working fluid volume to total volume of thermosyphon, the kinds of working fluid, the inclination angle, grooves and operating temperature have been used as the experimental parameters. The experimental results show that the number of grooves, the amount of the working fluid, the kind of working fluid, angle of inclination angle are very important factors for the operation of thermosyphon. The maximum heat transfer was obtained when the liquid fill was about 20 to 25 % of the thermosyphon volume. The relatively high rates of heat transfer have been achieved in the thermosyphon with grooves. The helical grooved thermosyphon having 70 to 80 grooves in water, 60 to 70 grooves in methanol and 70 to 80 grooves in ethanol shows the best heat transfer coefficient in both condensation.

  • PDF

Evaporation Pressure Drop of Carbon Dioxide in Horizontal Tubes with Inner Diameter of 4.57 mm and 7.75 mm (내경 4.57과 7.75 mm인 수평관내 이산화탄소의 증발 압력강하)

  • Son, Chang-Hyo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.30-37
    • /
    • 2008
  • The evaporation pressure drop of $CO_2$ (R-744) in horizontal tubes was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 7.75 and 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The pressure drop measured during the evaporation process of $CO_2$ increases with increased mass flux, and decreases as the saturation temperature increased. The evaporation pressure drop of $CO_2$ is very lower than that of R-22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the correlation of Choi et al. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

Indications, Outcomes, and Complications of Pedicled Propeller Perforator Flaps for Upper Body Defects: A Systematic Review

  • Lazzeri, Davide;Huemer, Georg M.;Nicoli, Fabio;Larcher, Lorenz;Dashti, Talal;Grassetti, Luca;Li, Qingfeng;Zhang, Yixin;Spinelli, Giuseppe;Agostini, Tommaso
    • Archives of Plastic Surgery
    • /
    • v.40 no.1
    • /
    • pp.44-50
    • /
    • 2013
  • Background The aim of this investigation was to systematically review the current literature to provide the best data for indications, outcomes, survival, and complication rates of pedicled propeller perforator flaps for upper body defects. Methods A comprehensive literature review for articles published from January 1991 to December 2011 was performed using the PubMed, Medline, and Cochrane Databases. Articles without available full-text, single case reports or papers with excessive missing data were excluded. Papers reporting pedicle-perforator (propeller) flaps used for lower extremity reconstruction were excluded from meta-analysis. Results From the initial 1,736 studies our search yielded, 343 studies qualified for the second stage of selection. Of 117 full-text reports screened, 41 studies, met the definitive inclusion and exclusion criteria. Of the selected 41 articles, 26 were case series, original papers or retrospective reviews and were included, whereas 15 were case report papers and therefore were excluded. Two hundred ninety-five propeller flaps were reported to have been used in a total of 283 patients. Indications include repair of trauma-induced injuries, post-trauma revision surgery, cancer resection, chronic infection, pressure sores, and chronic ulcers with a major complication rate (3.3%) comparable to that of free flaps. No specific exclusion criteria for the procedure were presented in the studies reviewed. Conclusions Pedicled propeller flaps are a versatile and safe reconstructive option that are easy and quick to raise and that provide unlimited clinical solutions because of the theoretical possibility of harvesting them based on any perforator chosen among those classified in the body.

A Study on the Condensation Heat Transfer and Pressure Drop in Internally Grooved Tubes Used in Condenser (응축기용 낮은 핀관의 내부 나선 홈에 의한 응축 열전달 성능과 압력손실에 관한 연구)

  • Han, Kyuil;Cho, Dong-Hyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.2
    • /
    • pp.212-222
    • /
    • 1998
  • Heat transfer performance improvement by fin and groovs is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapczodially shaped integral-fins having fin density from 748 to 1654fpm(fin per meter) and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also used for comparison. R-11 condensates at saturation state of 32 $^{\circ}C$ on the outside tube surface coded by inside water flow. All of test data are taken at steady state. The heat transfer loop is used for testing singe long tubes and cooling is pumped from a storage tank through filters and folwmeters to the horizontal test section where it is heated by steam condensing on the outside of the tubes. The pressure drop across the test section is measured by menas pressure gauge and manometer. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, overall heat transfer coefficients of finned tube are enhanced up to 1.6 ~ 3.7 times that of a plain tube at a constant Reynolds number. 2. Friction factors are up to 1.6 ~ 2.1 times those of plain tubes. 3. The constant pumping power ratio for the low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio. 4. A tube having a fin density of 1299fpm and 30 grooves has the best heat transfer performance.

  • PDF

Optimum Quality Control of Seismic Data of Kunsan Basin in Offshore Korea (국내대륙붕 군산분지에 대한 탄성파 전산처리의 최적 매개 변수 결정)

  • Kim, Kun-Deuk
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.3
    • /
    • pp.161-169
    • /
    • 1998
  • The Kunsan basin is a pull-apart basin which was formed during Tertiary. The pre-Tertiary section consists of various rock types, such as meta-sediments, igneous rocks, carbonates, clastics, and volcanics. Tertiary sections are the main targets for the petroleum exploration. In order to determine the optimum processing parameters of the basin, about 12 kinds of test processings were performed. The first main steps for the quality control is to determine the noisy or bad traces by examining the near trace section and shot gathers. The true amplitude recovery was applied to account for the amplitude losses due to spherical divergence and inelastic attenuation. Source designature and predictive deconvolution test were conducted to determine the optimum wavelet parameters and to remove the multiples. Velocity analysis was performed at 1km intervals. The optimum mute function was picked by locating the range of offsets which gives the best stacking response for any particular reflections. Post-stack deconvolution was tested to see if the quality of stacked data improved. The stacked data was migrated using a finite difference algorithm. The migration velocity was obtained from the stacking velocities using the time varying percentages. The AGC sections were provided for the structural interpretation. The RAP sections were used for DHI analysis and for the detection of volcanics.

  • PDF

Hypospadias and Megacolon in a Persian Cat (페르시안 고양이에서 발생한 요도밑 열림증과 거대결증증)

  • Kim, Sung-Eon;Choi, Ran;Park, Jasil;Yang, Hye-Mi;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.31 no.5
    • /
    • pp.454-456
    • /
    • 2014
  • A 9-month-old intact male Persian cat (3.2 kg of body weight) was referred with primary complaint of constipation. Diagnostic studies found severe constipation and megacolon. After immediate medical treatment (e.g. enema), the physical examination was performed and revealed that the unusual urethral opening was found approximately 0.5 cm ventral to the tip of the penis where a 3.5 fr tomcat catheter was easily advanced into the bladder. The case was diagnosed as hypospadias. The cat was treated with castration and medical therapy for constipation. To our best knowledge, this case is the first case report for feline hypospadias complicated with chronic constipation in Korea.

A Study on the Deformation Behavior of Material by V-Ring in Fine Blanking Process (파인블랭킹 공정에서 V-링에 의한 재료의 변형 거동에 관한 연구)

  • Lee, Chun-Kyu;Min, Kyung-Ho
    • Design & Manufacturing
    • /
    • v.11 no.3
    • /
    • pp.46-50
    • /
    • 2017
  • Press processing is one of the best machining methods capable of mass production, satisfying dimensional, shape and quality among the methods of processing a metal plate. Among them, Fine blanking is a method of obtaining a precise cross-section such as machining of the shear surface shape. In this research, Using SCP-1 and SHP-1 materials. The deformation behaviors of the material flow affecting the die height of the shear section in accordance with the position of the V-ring in the Fine blanking were compared and analyzed. Result of interpretation, It was confirmed that the force acts on the position where the material flow direction accurately forms the die roll that the material of SCP-1 is at a position of 1.5 mm and the material of SHP-1 is at 2.0 mm. As a result, it was confirmed that the state of fo1111ing the shear surface by the V-ring was excellent. Using analysis results, In the experiment, the height of the die roll was considered by applying The position of the V-ring was 1.5 mm in SCP-1 and 2.0 mm in SHP-1. As a result of comparing the height of the die rolls, the height values of the die rolls were different from each other, It has been considered that the tendency of the die rolls to coincide with each other. It is considered that the difference of the die roll height is caused by the pressure input of the V-ring. In this study, the deformation behavior of the material(In addition to the position of the V-ring, the flow direction of the material depends on the shape of the V-ring and the Indentation amount) is considered to be an important factor in determining die roll height.

Evaporation Heat Transfer Characteristics of $CO_2$ in a Horizontal Tube

  • Lee Dong-Geon;Son Chang-Hyo;Oh Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.3
    • /
    • pp.297-305
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver. a variable-speed pump. a mass flow meter. a pre-heater and evaporator (test section). The test section consists of a smooth. horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500\;kg/m^{2}s$. saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$. and heat flux of 10 to $40\;kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has greatly effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality. heat flux and saturation temperature. The evaporation heat transfer coefficient of $CO_2$ is very larger than that of R-22 and R-134a. In making a comparison between test results and existing correlations. the present experimental data are the best fit for the correlation of Jung et al. But it was failed to predict the evaporation heat transfer coefficient of $CO_2$ using by the existing correlation. Therefore. it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

A Case of Thyroarytenoid Myectomy with Selective Recurrent Laryngeal Nerve Section in Intractable Spasmodic Dysphonia: A Long-Term Follow-Up (난치성 연축성 발성장애 환자에서 갑상피열근 절제술 및 선택적 반회후두신경 절제술 1예: 장기 추적 관찰)

  • Lee, Yun Ji;An, You Young;Park, Ki Nam;Lee, Seung Won
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.31 no.1
    • /
    • pp.35-38
    • /
    • 2020
  • Spasmodic dysphonia is a disease presumed to be a form of focal laryngeal dystonia. The widely used first-line treatment is botulinum toxin injection to the thyroarytenoid muscles. In spite of the effectiveness and safety of this method, it has a temporary effect that lasts only several months, resulting the patients' symptom fluctuating, called 'Botox rollercoaster.' Some surgical techniques had tried, but they had shown several limitations including high rate of recurrence. We tried thyroarytenoid myectomy with selective recurrent laryngeal nerve section in a patient with intractable spasmodic dysphonia. This procedure is an alternative treatment of spasmodic dysphonia to prevent recurrence and improve symptoms. During five years of follow-up, she has shown steady quality voice without any complication. To the best of our knowledgement, this is the longest follow-up case of this operation in South Korea.