• 제목/요약/키워드: bench scale unit

검색결과 25건 처리시간 0.027초

Development of a robust bench-scale testing unit for low-pressure membranes used in water treatment

  • Huang, Haiou;Schwab, Kellogg;Jacangelo, Joseph G.
    • Membrane and Water Treatment
    • /
    • 제2권2호
    • /
    • pp.121-136
    • /
    • 2011
  • A bench-scale test has recently been proposed as a predictive tool to minimize the scope of pilot-scale testing or to optimize the operation of full-scale membrane filtration systems. Consequently, a bench-scale testing unit was developed for this purpose and systematically evaluated in this study. This unit was capable of accommodating commercially available, low pressure, hollow fiber (LPHF) membranes with various configurations for testing under conditions comparable to real-world applications. Reproducibility of this unit in assessing membrane fouling and microbial removal efficiency of LPHF membranes was tested and statistically comparable results were obtained. This unit serves as a useful apparatus for academic researchers and utilities to evaluate the performance of LPHF membranes used for water treatment.

Bench급 석탄가스화 시스템 제어로직의 최적화 (Control Logic Optimization for the Bench Scale Coal Gasification System)

  • 김원배;조성수;유희종;윤용승
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2000년도 추계 학술발표회 논문집
    • /
    • pp.33-38
    • /
    • 2000
  • IGCC(Integrated Gasification Combined Cycle) BSU(Bench Scale Unit) 석탄 가스화공정은 정상상태 조업시 약 145$0^{\circ}C$, 25기압의 고온 및 고압의 조건하에서 운전되기 때문에 설정된 운전조건을 안정하게 유지하기 위해서 이러한 조건에 상응하는 안정된 제어로직의 구성은 매우 중요한 요소이다.(중략)

  • PDF

혼합냉매를 이용한 천연가스 액화공정의 제어변수 분석 (Analysis of the Control Variables for Natural Gas Liquefied Process Using Mixed Refrigerant)

  • 이재용;김문현;박찬국
    • 한국가스학회지
    • /
    • 제17권4호
    • /
    • pp.51-57
    • /
    • 2013
  • 천연가스 액화 공정은 상온의 천연가스를 상압 $-160^{\circ}C$ 이하로 냉각해서 액화시키는 공정으로, 안정된 LNG 생산을 위해서는 최적의 제어 전략이 필요하다. 제어 전략을 수립할 때 가장 중요한 작업 중 하나가 공정의 분석인데, 조절 변수의 변화에 따른 제어 변수의 변화를 파악하는 것이다. 본 논문에서는 C3MR(Propane Pre-cooled Mixed Refrigerant) 공정으로 BSU(Bench Scale Unit)를 제작하여 천연가스 액화 공정을 실험하였다. 각 조절변수의 조작에 따른 유량의 변화가 공정에 미치는 영향을 알아보기 위해서 냉매의 유량변화에 따른 냉매 온도 변화 및 천연가스의 온도 변화를 분석하였고, 천연가스 자체의 유량 변화에 따른 냉매의 온도 변화를 분석함으로써 3개의 조절 변수와 공정의 제어변수들과의 관계를 알아보았다. 각 제어변수들은 독립적인 요소들이 아닌 서로 연관되어 유기적인 움직임을 보였으나, 특정 조절 변수의 변화에 따라 큰 반응을 보이는 제어 변수를 확인 할 수 있었다.

SBR 및 MBR 복합공정을 적용한 Bench-scale Shipboard STP에서의 미생물 우점종에 관한 연구 (A Study on Microorganism Dominant Species in Bench-scale Shipboard STP Using Combined SBR and MBR Process)

  • 최영익;신대열;사나 만수르;권민지;정진희;정병길
    • 한국환경기술학회지
    • /
    • 제19권6호
    • /
    • pp.550-555
    • /
    • 2018
  • 국제 해사기구 (IMO)에서 MARPOL 73/78은 조문과 여섯 개의 부속서로 구성되어 있다. Annex IV는 선박의 하수를 규제한다. 2012년 제 64회 결의안에서 선박에서 배출되는 하수 중 영양염류를 제거하도록 규제하였다. 2014년 해양수산부의 지원으로 영양염류를 제거 할 수 있는 대용량 폐수처리 장치를 개발하였다. Sequence Batch Reactor (SBR)와 Membrane Bio Reactor (MBR)를 결합한 새로운 공정이 개발되었다. 현존하는 SBR 공정의 사이클에서는 침전을 제외하고 통기 및 교반만을 사용하였고, 상기 막은 처리 된 물을 배출 시키는데 사용하였다. 본 연구에서는 MACROGEN 사의 NGS 분석 기술을 이용하여 Bench 규모 폐수처리 설비를 이용한 하수처리장 원수를 처리하기 위한 최적 운전조건에서 폭기조 내 미생물의 우점종을 분석하였다. 그 결과 Bacteroidetes는 호기성 박테리아의 27.1 %를 차지했으며 Gammaproteobacteria는 혐기성 박테리아의 16.8 %를 차지하였다. Operational taxonomic unit ratio에 Others 항목이 차지하는 비율도 상당하다고 볼 수 있는데 기존의 오수처리를 위해 필요했던 미생물 외에 아직 NCBI (National center for Biotechnology Information)에 등록되지 않은 미생물일 가능성이 있어 추후 연구가 필요하다고 판단된다.

DEVELOPMENT OF PRECISION ATTITUDE DETERMINATION SYSTEM FOR KOMPSAT-2

  • Yoon Jae-Cheol;Shin Dongseok;Lee Hungu;Lee Young-Ran;Lee Hyunjae;Bang Hyo-Choong;Cheon Yee-Jin;Shin Jae-Min;Moon Hong-Youl;Lee Sang-Ryool;Jeun Gab-Ho
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권2호
    • /
    • pp.296-299
    • /
    • 2004
  • KARI precision attitude determination system has been developed for high accurate geo-coding of KOMPSAT-2 image. Sensor data from two star trackers and a IRU are used as measurement and dynamic data. Sensor data from star tracker are composed of QUEST and unit vector filter. Filter algorithms consists of extended Kalman filter, unscented Kalman filter, and least square batch filter. The type of sensor data and filter algorithm can be chosen by user options. Estimated parameters are Euler angle from 12000 frame to optical bench frame, gyro drift rate bias, gyro scale factor, misalignment angle of star tracker coordinate frame with respect to optical bench frame, and misalignment angle of gyro coordinate frame with respect to optical bench frame. In particular, ground control point data can be applied for estimating misalignment angle of star tracker coordinate frame. Through the simulation, KPADS is able to satisfy the KOMPSAT-2 mission requirement in which geo-location accuracy of image is 80 m (CE90) without ground control point.

  • PDF

전기집지기 집진특성 실험 및 유한차분해석에 관한 연구 (Experimental and Finite Difference Method(FDM) Analysis on Collection Characteristics of Electrostatic Precipitator)

  • 김용진;홍원석;최헌오;함병훈;민춘식;유기선
    • 한국대기환경학회지
    • /
    • 제10권1호
    • /
    • pp.49-56
    • /
    • 1994
  • Electrostatic Precipitators( EP ) are widely used in industry for controlling the emission of particulate pollutant Recently, a number of researches have been conducted to solve performance and reliability problems of EP, As a result of researches in the laboratory and of pilot scale, a technology of wide-pitch-spacing has been successfully applied to full scale units. It has been known that the wide-pitch-spacing can reduce the capital cost of newly installed precipitators, and the cost of rebuilding existing uints. In this paper, a systematic study was performed to develop a wide-pitch electrostatic precipitator. The study includes experimental and numerical work on the following : Particle collection characteristics for a bench-scale unit; gas flow characteristics( temperature and velocity distributions): other EP operating variables such as electric Power supply/control. The results are applied directly to design of wide-pitch-spacing EP and the developed numerical model was found to be a good argreement with the experimental results. The EHD simulation program is necessary to design the high efficiency EP.

  • PDF

MBR technology for textile wastewater treatment: First experience in Bangladesh

  • Saha, Pradip;Hossain, Md. Zakir;Mozumder, Md. Salatul I.;Uddin, Md. Tamez;Islam, Md. Akhtarul;Hoinkis, Jan;Deowan, Shamim A.;Drioli, Enrico;Figoli, Alberto
    • Membrane and Water Treatment
    • /
    • 제5권3호
    • /
    • pp.197-205
    • /
    • 2014
  • For the first time in Bangladesh, a bench scale membrane bioreactor (MBR) unit was tested in treating a textile wastewater in the industry premises of EOS Textile Mills LTD, Dhaka for three months. The performance of the unit was compared with that of the conventional activated sludge treatment plant, which is in operation in the same premises. The COD and BOD removal efficiency of the MBR unit reached to around 90% and 80% respectively in 20 days whereas the removal efficiency of the conventional treatment plant was as low as 40-50% and 38-40% respectively. The outlet COD and the BOD level for the MBR unit remained stable in spite of the fluctuation in the feed value, while the conventional effluent treatment plant (ETP) failed to keep any stabilized level. The performance of the MBR unit was much superior to that of the functional ETP and the water treated by the MBR system can meet disposal standard.

Datong탄에 대한 Bench Scale Unit급 분류층 석탄가스화 연구 (Gasification Study of Datong Coal in a Bench Scale Unit of Entrained Flow Gasifier)

  • Ryu, Si-Ok;Kim, Jae-Ho;Lee, Hyo-Jin;Lee, Jae-Goo;Park, Tae-Jun;An, Dal-Hong;Park, Ho-Young
    • 에너지공학
    • /
    • 제6권1호
    • /
    • pp.96-103
    • /
    • 1997
  • 0.5~1.0톤/일 용량의 BSU급 분류층 가스화기에서 중국산 Datong탄에 대한 석탄가스화 특성실험을 하였다. 가스화기의 반응온도는 1300~155$0^{\circ}C$를 유지하였으며, 실험에 사용된 슬러리농도는 62.5wt% ($H_2O$/Coal=0.6)였다. 산소 및 슬러리는 버너에 주입되기전 예일을 실시하였으며 $O_2$/Coal의 공급비는 0.8~l.2를 유지하였다. 또한 슬러리의 점도를 낮추고 유동성을 향상시키기 위하여 첨가제로서 CWM 1002와 NaOH를 각각 0.3%와 0.05% 추가하였다. 석탄가스화 실험에서 측정된 생성기체는 주로 수소, 일산화탄소 및 이산화탄소로 구성되어 있으며 미량의 메탄도 생성되었다. 생성된 가스는 반응온도가 증가함에 따라 H$_2$와 CO의 생성량은 증가하는 반면 $CO_2$의 양은 감소하였다. 산소의 공급량이 증가함에 따라 $CO_2$의 생성량은 지속적으로 증가하고 CO 및 H$_2$의 생성량은 $O_2$/Coal의 비가 약 0.9에서 최대치를 나타낸 후 감소하였으며, 생성가스 발열량은 1700~2400 kcal/N㎥을 나타내었다.

  • PDF