• Title/Summary/Keyword: behavior-test

Search Result 12,355, Processing Time 0.041 seconds

Experimental Study on Combined Failure Damage of Bi-directional Prestressed Concrete Panel under Impact-Fire Loading (충돌 후 화재에 대한 이방향 프리스트레스트 콘크리트 패널부재의 복합 파괴손상에 관한 실험적 연구)

  • Yi, Na-Hyun;Lee, Sang-Won;Choi, Seung-Jai;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.429-440
    • /
    • 2014
  • Since the World Trade Center and Pentagon attacks in 2001, terror, military attack, or man-made disaster caused impact, explosion, and fire accident have frequently occured on civil infrastructures. However, structural behavior researches on major Prestressed Concrete (PSC) infrastructures such as bridges, tunnels, Prestressed Concrete Containment Vessel (PCCVs), and LNG tanks under extreme loading are significantly lacking. Especially, researches on possible secondary fire scenarios after terror, bombing, collision of vehicles and vessels on concrete structures have not been performed domestically where most of the past researches related to extreme loadings on structures focused on an independent isolated extreme loading scenario. Due to the outcry of public concerns and anxiety of potential terrorist attacks on major infrastructures and structures, a study is urgently needed at this time. Therefore, in this study, the bi-directional prestressed concrete $1400{\times}1000{\times}300mm$ panels applied with 430 kN prestressing force using unbonded prestressing thread bars were experimentally evaluated under impact, fire, and impact-fire combined loadings. Due to test site restrictions, impact tests were performed with 14 kN impactor with drop heights of 10m and 3.5 m to evaluate impact resistance capacity. Also, fire and impact-fire combined loading were tested using RABT fire loading curve. The measured residual strength capacities of PSC and RC specimens applied with impact, fire, impact-fire combined loadings were compared with the residual strength capacity of undamaged PSC and RC specimens for evaluation. The study results can be used as basic research data for related research areas such as protective design and numerical simulation under extreme loading scenarios.

Effect of a 6-month Low Sodium Diet on the Salt Taste Perception and Pleasantness, Blood Pressure and the Urinary Sodium Excretion in Female College Students (6개월간의 저염식이 여자 대학생의 짠맛에 대한 인지와 기호, 혈압 및 뇨 나트륨 배설량에 미친 영향)

  • Chang, Soon-Ok
    • Journal of Nutrition and Health
    • /
    • v.43 no.5
    • /
    • pp.433-442
    • /
    • 2010
  • The study aim was to examine the effect of sensory responses of subjects after 6-month dietary sodium reduction with the aid of nutritional education. Fourteen female college students voluntarily restricted their sodium intake for 6 months, during which time they received nutritional education on the low sodium diet. As a control group, 10 students, whose anthropometric measurement, sodium intake behavior, and blood pressure were not different from those of the experimental group, were maintained on a normal diet. For the sensory responses of subjects, the salt taste perception and pleasantness for graded (0.15-1.3%) NaCl solutions were measured by a 9-point hedonic scale. The optimum sodium concentration, urinary sodium excretion, and blood pressure were measured. All the measurements were done at the beginning and end of the experiment. The sensory evaluation revealed an absence of any difference between the two groups in salt taste perception and pleasantness responses at the beginning. After 6-month adaptation, the experimental group subjects showed higher responses to low NaCl solution (0.15, 0.3, 0.5%) in salt taste perception and pleasantness evaluation while the control group subjects exhibited the opposite response. The optimum sodium concentration was reduced from 105.6 mmol to 80.7 mmol (p = 0.015) and the urinary sodium excretion was also reduced from 1,398 mg to 906 mg (p = 0.041) only in the experimental group. Systolic blood pressure was significantly reduced in the experimental group, although there was no correlation between the urinary sodium excretion and blood pressure. The optimum sodium concentration was negatively correlated with the urinary sodium excretion (r = 0.418, p = 0.053), indicating that adaptation to low sodium diet can reduce sodium intake. Further study on the individual responses of subjects on a low sodium diet by periodical evaluation may provide useful data for setting the duration needed to stabilize a lowered appetite for sodium.

Degradation Mechanisms of TCE in Cement/Fe(II) Systems (시멘트/Fe(II) 시스템에서의 TCE 분해 기작)

  • Lee, Yun-Mo;Kang, Wan-Hyup;Choi, Won-Ho;Hwang, In-Sung;Park, Joo-Yang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.778-782
    • /
    • 2007
  • This study investigated the dechlorination mechanisms of TCE by Fe(II) associated with cement. Batch slurry experiments were peformed to investigate the behaviors of selected ions; Fe(II), Fe(III), $Ca^{2+}$, $SO_4^{2-}$ in cement/Fe(II) system. The kinetic experiments of TCE in cement/Fe(II) systems showed that injected Fe(II) was mostly sorbed on cement within 0.5 day and 90% of injected 200 mM sulfate was sorbed on cement within 0.5 day when $[TCE]_0$ = 0.25 mM and $[Fe(II)]_0$ = 200 mM. The kinetic experiments of TCE in hematite/CaO/Fe((II) systems were conducted for simulation of cement/Fe(II) system. Calcium oxide that is one of the major components in cement hydration reactions or has a reactivity in limited conditions. Hematite assumed the ferric iron oxide component of cement. The reactivities observed in hematite/CaO/Fe(II) system were comparable to those reported for cement/Fe(II) systems containing similar molar amounts of Fe(II). The behavior of Fe(II) and $SO_4^{2-}$ sorbed on solid phase at an early stage of reaction in hematite/CaO/Fe(II) system was similar to that of cement/Fe(II) system. Ferric ion was released from hematite at an early period of reaction at low pH. The experimental evidence of kinetic test using hematite/CaO/Fe(II) system implies that the reactive reductant is a mixed-valent Fe(II)-Fe(III) mineral, which may be similar to green rust. Fe(II) sorbed on cement can be converted to new mineral phase having a reactivity such as Fe(II)-Fe(III) (hydr)oxides in cement/Fe(II) systems.

A Study on the Efficient Human-Robot Interaction Style for a Map Building Process of a Home-service Robot (홈서비스로봇의 맵빌딩을 위한 효율적인 휴먼-로봇 상호작용방식에 대한 연구)

  • Lee, Woo-Hun;Kim, Yeon-Ji;Kim, Hyun-Jin;Yang, Gyun-Hye;Park, Yong-Kuk;Bang, Seok-Won
    • Archives of design research
    • /
    • v.18 no.2 s.60
    • /
    • pp.155-164
    • /
    • 2005
  • Home-service robots need to have sufficient spatial information about the surroundings for interacting with human intelligently and performing services efficiently. It is very important to investigate the efficient interaction style that supports map building task through human-robot collaboration. We first analyzed map building task with a cleaning robot and drew 4 design factors and tentative solutions, including map building procedure (task-preferred procedure/space- preferred procedure), LCD display installation (robot/robot+remote control), navigation method (push type/pull type), feedback modality(GUI/GUI+TTS). The design factors and tentative solutions were defined as independent variables and levels. This research investigated how those variables affect to the human task performance and behavior in map building tast. 8 kinds of experiment prototypes were built and usability test among 16 house wives was conducted for acquiring empirical data. As the experiment result, in terms of map building procedure, space-preferred procedure indicated better task performance than task-proffered procedure as we expected. For the LCD display installation factor, remote control with LCD display indicated higher task performance and subjective satisfaction. In robot navigation method, it was very difficult to find a significant difference between push type and pull type which contrary to our expectation. In fact, push type indicated higher subjective satisfaction. Also in feedback modality, we have acquired negative feedback an additional TTS operation guidance. It seems that robot's autonomy before achieving spatial information is rudiment condition which means users are just interacting with a mobile appliance. Thus they prefer remote-control-based interaction style in robot map building process as they used in traditional appliance control.

  • PDF

Performance Evaluation of High Strength Lattice Girder by Structural Analyses and Field Measurements (구조해석과 현장계측에 의한 고강도 격자지보재의 성능 평가)

  • Lee, Jeo-Won;Min, Kyong-Nam;Jeong, Ji-Wook;Roh, Byoung-Kuk;Lee, Sang-Jin;Ahn, Tae-Bong;Kang, Seong-Seung
    • The Journal of Engineering Geology
    • /
    • v.30 no.3
    • /
    • pp.237-251
    • /
    • 2020
  • This study examined structural analysis of supports in tunnel and displacement and underground stress of tunnel by measurement, in order to evaluate the performance of high-strength lattice girders developed as a substitute for H-profiles. According to the three-dimensional nonlinear structural analysis results of the tunnel support, the load and displacement relationship between the H-profiles and the high-strength lattice girders showed almost the same behavior, and the maximum load of the high-strength lattice girders were 1.0 to 1.2 times greater than the H-profiles. By the results of the three-dimensional tunnel cross-section analysis of the supports, the axial force was occurred largely in the lower left and right sides of the tunnel, and showed a similar trend to the field test values. In the results of the measurement of the roof settlement and rod extension, the final displacement of the steel arch rib (H-profile) and high-strength lattice girder section in tunnel was converged to a constant value without significant difference within the first management standard of 23.5 mm. According to the results of underground displacement measurement, the final change amount of the two support sections showed a slight displacement change, but converged to a constant value within the first management standard of 10 mm. By the results of measurement of shotcrete stress and steel arch rib stress, the final change amount of the two support sections showed a slight stress change, but converged to a constant value within the first management standard of 81.1 kg/㎠ and 54.2 tonf.

Evaluation of Image Qualities for a Digital X-ray Imaging System Based on Gd$_2$O$_2$S(Tb) Scintillator and Photosensor Array by Using a Monte Carlo Imaging Simulation Code (몬테카를로 영상모의실험 코드를 이용한 Gd$_2$O$_2$S(Tb) 섬광체 및 광센서 어레이 기반 디지털 X-선 영상시스템의 화질평가)

  • Jung, Man-Hee;Jung, In-Bum;Park, Ju-Hee;Oh, Ji-Eun;Cho, Hyo-Sung;Han, Bong-Soo;Kim, Sin;Lee, Bong-Soo;Kim, Ho-Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.253-259
    • /
    • 2004
  • in this study, we developed a Monte Carlo imaging simulation code written by the visual C$\^$++/ programing language for design optimization of a digital X-ray imaging system. As a digital X-ray imaging system, we considered a Gd$_2$O$_2$S(Tb) scintillator and a photosensor array, and included a 2D parallel grid to simulate general test renditions. The interactions between X-ray beams and the system structure, the behavior of lights generated in the scintillator, and their collection in the photosensor array were simulated by using the Monte Carlo method. The scintillator thickness and the photosensor array pitch were assumed to 66$\mu\textrm{m}$ and 48$\mu\textrm{m}$, respertively, and the pixel format was set to 256 x 256. Using the code, we obtained X-ray images under various simulation conditions, and evaluated their image qualities through the calculations of SNR (signal-to-noise ratio), MTF (modulation transfer function), NPS (noise power spectrum), DQE (detective quantum efficiency). The image simulation code developed in this study can be applied effectively for a variety of digital X-ray imaging systems for their design optimization on various design parameters.

Bioequivalence of Burophil Capsule to Surfolase Capsule (Acebrophylline 100 mg) (설포라제 캡슐(아세브로필린 100 mg)에 대한 부로필 캡슐의 생물학적 동등성)

  • Cho, Hea-Young;Park, Eun-Ja;Kang, Hyun-Ah;Kim, Se-Mi;Park, Chan-Ho;Oh, In-Joon;Lim, Dong-Koo;Lee, Myung-Hee;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.3
    • /
    • pp.179-185
    • /
    • 2005
  • Acebrophylline is a compound produced by salifying ambroxol with theophylline-7 -acetic acid. After acebrophylline administration, the salt splits into these two components which feature a peculiar pharmacokinetic behavior, an adequate ambroxol and a low theophylline-7-acetic acid serum levels. The purpose of the present study was to evaluate the bioequivalence of two acebrophylline capsules, Surfolase (Hyundai Pharm. lnd. Co., Ltd.) and Burophil (Kuhnil Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of ambroxol from the two acebrophylline formulations in vitro was tested using KP VIII Apparatus II method with various dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty eight healthy male subjects, $23.25{\pm}1.43$ years in age and $64.82{\pm}6.77$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After two capsules containing 100 mg as acebrophylline were orally administered, blood was taken at predetermined time intervals and the concentrations of ambroxol in serum were determined using HPLC with electrochemical detector (ECD). The dissolution profiles of two formulations were similar at all dissolution media. In addition, the pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug Surfolase, were -1.64, -3.33 and -0.92% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 $(e.g., \;log\;0.93{\sim}log\;1.05\;and\;log\;0.88{\sim}log\;1.05$ for $AUC_t$, and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Burophil capsule was bioequivalent to Surfolase capsule.

Study of the corrosion effect of CO2 stream with SO2 and NO2 on a phosphate coated steel tube (SO2 및 NO2 포함 고압 CO2 스트림이 인산염 코팅 CO2 수송관 부식에 미치는 영향)

  • Cho, Meang-Ik;Kang, Seong-Gil;Huh, Cheol;Baek, Jong-Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.6973-6979
    • /
    • 2014
  • To mitigate global warming and climate change, many countries are investing massively on the development of CCS technology, which is assumed to be the key technology to reduce $CO_2$ emissions. CCS technology is comprised of the capture, transport, and storage processes. During the capture process, impurities other than $CO_2$ are inevitably flowed into the $CO_2$ stream. In the present study, corrosion characteristics of a phosphate coated tube for $CO_2$ transportation was investigated with a $CO_2$ stream composed of $CO_2$, $H_2O$, $SO_2$, and $NO_2$. The test specimen was a phosphate coated steel tube, which was filled with $CO_2$ stream with the impurities mentioned above. SEM-EDS analysis is conducted to investigate the corrosion behavior. The results showed that although the H2O concentration did not exceed the solubility limit, corrosion occurred in the specimen, which has an inflow of $SO_2$ or $NO_2$. This suggests that the $SO_2$, $NO_2$ and $H_2O$ concentration should be strictly controlled. These results suggest that the $SO_2$ and $NO_2$ concentration should be controlled below 175ppm and 65ppm, respectively.

A Study for Alexithymia in the Patients with Panic Disorder (공황장애환자에서 감정표현불능증에 대한 연구)

  • Choi, Young-Hee;Jang, Hyuck-Jin;Kim, Min-Sook
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.14 no.1
    • /
    • pp.53-61
    • /
    • 2006
  • Objectives: This study was designed to evaluate difference of the alexithymia between panic patients and normal controls by examination of the relationships between different components of the alexithymia construct and level of anxiety and depression in panic patients and normal controls. Methods The subjects were 167 patients who met DSM-IV criteria for panic disorder and 110 normal controls. They drew up symptom checklists and self-rating scales, and were measured by Anxiety Disorders Interview Schedule-Panic attack & Agoraphobia(ADIS-P & A), Korean version of Toronto Alexithymia Scale (TAS-20K), Spielberger State-Trait Anxiety Inventory-State & Trait (STAI-S & T), Beck Depression Inventory (BDI), and Revised Anxiety Sensitivity Index (ASI-R). For statistical analysis, we performed t-test to compare the sociodemographic characteristics and the scores of self reported scales between panic patients and normal controls. Pearson correlation was performed between TAS-20K and it's subfactors, STAI-S & T, ASI-R and BDI in panic patients and normal controls. And stepwise multiple regression analysis was preformed to explain results of correlation analysis for alexithymia. Results: The panic patients reported more significant alexithymic (p<0.001), more difficulty identifying feeling (p<0.001) and describing feeling (p=0.001) than normal controls. Futhermore, panic patients were more significant anxious, sensitive to anxious feeling and depressive than normal controls. Moreover, the alexithymia of panic patients was explained by trait-anxiety $({\Delta}R^2=0.255)$ and anxiety sensitivity $({\Delta}R^2=0.062)$, that of normal controls was predicted by depression $({\Delta}R^2=0.144)$ and anxiety sensitivity $({\Delta}R^2=0.033)$ Conclusion: The panic patients reported more anxious and sensitive to anxious feeling, and these symptoms predict alexithymia in panic patients. However, the alexithymia of normal controls was explained by depression more than anxiety sensitivity, and such a result isn't consistent with previous studies and this may be mainly due to difference of the homogeneity in object of the studies.

  • PDF

A Study of the Relation of Stress to Oral Health-Related of Life in Male High School Students of Chungnam (충남지역 일부 남자 고등학생들의 스트레스와 구강건강관련 삶의 질과의 관련성 연구)

  • Jung, Yu Yeon
    • Journal of dental hygiene science
    • /
    • v.14 no.2
    • /
    • pp.158-166
    • /
    • 2014
  • This study is trying to grasp the stress of the male high school students and the correlation between the stress according to the oral health important cognitive and self-rated oral health status and number of brushing, emphasizing the need for the education of oral health important, providing the basic data in order to accomplish correctly until the enhance of oral health-related quality of the oral health correct behavior. From May to July 2013, a self administered survey was conducted by the selected by convenience sampling from subjects of two high school located in Chungcheongnam-do 1, 2 grade. The SPSS PASW Statistics 18.0 and Amos 5.0 program had been used for the statistical data analysis. The study results were as follow: 1) Among five areas of stress, the stress of school life was the highest as 2.11 points and the stress of home problem was the lowest as 1.51 points; 2) The significance analysis results between the five areas of stress according to the stress of latent variable and the oral health-related quality of life all showed the significant difference (p<0.001). 3) Oral health-related quality of life was higher as oral health important and self-rated oral health status positive. Furthermore oral health-related quality of life was higher as number of brushing increased; 4) Fit Measures test result of stress, academic level, and family economic level model all showed more than 0.9 in goodness of fit index (GFI), adjusted GFI, normed fit index and root mean square residual and root mean square error of approximation values is all estimated less than 0.1, so it showed good model. From this study, it can be concluded that there is the correlation between stress and oral health-related quality of life.