• 제목/요약/키워드: bearing resistance

검색결과 599건 처리시간 0.019초

은 박막이 코팅된 베어링 표면의 구름 저항 거동 고찰 (An Experimental Study on the Rolling Resistance of Bearing Surfaces Covered by Pure Silver Film)

  • 양승호;공호성;윤의성;권오관
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1997년도 제25회 춘계학술대회
    • /
    • pp.101-110
    • /
    • 1997
  • An experimental study was performed to discover the tribological behaviors of pure silver coated 52100 bearing steel. Pure silver coatings ranging from 80 nm to several micrometers were produced by a thermal evaporation coating method. Experiments using a thrust ball bearing-typed rolling test-rig were performed for the investigations of the influence of coating thickness on the tribological rolling behavior. The existence of optimum film thickness which revealed minimum rolling resistance was discovered. A careful analysis on the contact surfaces for the optimum film thickness has been performed. The contact patches produced by the transferred silver films played an important role for the rolling resistance to keep low.

  • PDF

은 박막이 코팅된 베어링 표면의 구름 저항 거동 고찰 (An Experimental Study on the Rolling Resistance of Bearing Surfaces Covered by Pure Silver Film)

  • 양승호;공호성;윤의성;권오관
    • Tribology and Lubricants
    • /
    • 제13권3호
    • /
    • pp.85-92
    • /
    • 1997
  • An experimental study was performed to discover the tribological behaviors of pure silver coated 52100 bearing steel. Pure silver coatings ranging from 80 nm to several micrometers were produced by a thermal evaporation coating method. Experiments using a thrust ball bearing-typed rolling test-rig were performed for the investigations of the influence of coating thickness on the tribological rolling behavior. The existence of optimum film thickness which revealed minimum rolling resistance was discovered. A careful analysis on the contact surfaces for the optimum film thickness has been performed. The contact patches produced by the transferred silver films played an important role for the rolling resistance to keep low.

말뚝기초의 연적 방향 극한하중

  • 김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 기초기술위원회 워크샵
    • /
    • pp.209-236
    • /
    • 2002
  • Ultimate pile capacity - Point resistance - Frictional resistance - Determination of point and frictional resistances from field tests - Summary of recommendations from design Group effects Settlement analysis.

  • PDF

스핀들 모터용 유체베어링의 마찰 및 마멸 특성 (Friction and Wear Characteristics of Fluid Bearing for Spindle Motors)

  • 정성훈;박동신;이영제;정광섭;정대현
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제32회 추계학술대회 정기총회
    • /
    • pp.372-377
    • /
    • 2000
  • Recently, fluid bearing have been studied to apply to spindle motors for hard disk drive, printer and others. Since fluid bearing have excellent stiffness and good load carrying capacity, the bearing proved to be suitable for those devices related to computer industry. In this paper, the friction and wear characteristics of the bearing were studied. The bearing appears good performance at a high temperature and high wear resistance.

  • PDF

양방향말뚝 재하시험을 통한 현장타설말뚝의 연직지지력 설계정수 산정 (Evaluation of Design Parameters for Axial Bearing Capacity of Drilled Shafts by Bi-directional Loading Tests)

  • 정경자;조종석;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 추계 학술발표회
    • /
    • pp.574-584
    • /
    • 2006
  • Bi-directional loading test data are available to evaluate the design parameters which reflect the characteristics of a construction method and the variations of ground at the site where drilled shafts are installed. The method to obtain the design parameters of a real bridge by hi-directional loading test was introduced. The plans of multi-level testing and installation of measuring instruments should be made according to the rough estimation of axial bearing capacity, the length of pile, and the construction method. While the relationship between end bearing resistance and displacement was obtained directly from the hi-directional loading test, the relationship between unit side resistance and displacement was calculated through the measuring values. 1% displacement of pile diameter was adopted as the criteria of failure for ultimate resistance. As the settlement of pile head at the total ultimate bearing capacity obtained from these method was less than 1.5 % of pile diameter, this method was conservative to use in the field.

  • PDF

Performance of Rock-socketed Drilled Shafts in Deep Soft Clay Deposits

  • Kim, Myung-Hak
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 추계 학술발표회
    • /
    • pp.409-429
    • /
    • 2006
  • In designing rock-socketed drilled shaft, bearing capacity evaluation is very important because the maximum values of base and side resistance are not generally mobilized at the same value of displacement, FHWA and AASHTO code suggest different ultimate bearing capacity formular according to rock type and shaft settlement. In domestic code suggest base resistance and side resistance can be added on condition that after confirming the result of field load test with axial load transfer test. This paper shows that static load test and hi-directional load test result analysis of deep rock-socketed drilled shaft in three different sites. Load-settlement curve, t-z, and q-w curve in rock-socketed part were calculated and compared. t-z curve in weathered and soft rock showed no deflection softening behavior in pretty large strain (about 2-3% of diameter). Ultimate resistance could be the summation of side resistance and base resistance in rock-socketed drilled shaft in domestic sites.

  • PDF

기성말뚝의 지지력 거동해석과 시공관리방안 (Bearing Capacity and Control Method of Driven Piles)

  • 박영호;김경석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.249-258
    • /
    • 1999
  • Dynamic load and static load tests are performed on steel pipe piles and concrete piles at five construction sites in highway to compare the difference of load bearing mechanisms. At each site, one steel pile is instrumented with electric strain gages and dynamic tests are performed on the pile during installation. Damages of strain gages due to the installation are checked and static test is performed upon the same pile after two or seven days as well. It shows that load transfer from side friction to base resistance behaves somewhat differently according to the results of load-settlement analysis obtained from PDA and static load test. Initial elastic stage of load settlement curves of two load tests is almost similar. But after the yielding point, dynamic resistance of pile behaves more stiffer than static resistance, thus, dynamic load test result might overestimate the real pile capacity compared with static result. Analysis of gage readings shows that unit skin friction increases exponentially with depth. The skin friction is mobilized at the 1∼2m above the pile tip and contributes to the considerable side resistance. Comparison of side and base resistances between the measured value and the calculated value by Meyerhof's bearing capacity equation using SPT N value shows that the calculated base resistance is higher than the measured. Therefore, contribution of side resistance to total capacity shouldn't be ignored or underestimated. Finally, based upon the overall test results, a construction control procedure is suggested.

  • PDF

풍화암에 근입된 현장타설말뚝의 지지거동 분석 (Bearing Capacity of Cast-in-situ Concrete Piles Socketed in Completely Weathered Gneiss)

  • 전경수;김정환;김명모
    • 한국지반공학회논문집
    • /
    • 제15권6호
    • /
    • pp.155-165
    • /
    • 1999
  • 화강편마암으로 된 풍화암이 기반암인 암반에 소켓된 말뚝의 지지 거동을 알기 위하여 직경 40cm인 현장타설말뚝 8개를 시공하고 말뚝 재하 시험을 실시하였다. 지반 조사는 예비조사, 본조사, 그리고 시험후 조사 등 3차례에 걸쳐서 이루어 졌으며, 이 때 BX와 NX 보링(12개소) 조사와 탄성파 탐사 등이 시행되었다. 암반 소켓 말뚝의 지지 거동을 주면부와 선단부로 분리하여 평가하기 위하여 암반 소켓 깊이를 3m, 6m 그리고 9m등으로 다양하게 하고, 선단부 지지력의 영향을 배제하기 위하여 말뚝 선단부에 스타이로폼(styrofoam)을 매설하기도 하였다. 그리고 말뚝 깊이에 따른 하중 전이 해석을 위하여 말뚝 철근에 변형률 게이지 등을 설치하고 재하 시험을 수행하였다. 상기의 재하 시험 결과로부터 국내 화강 편마암으로 된 풍화암에 소켓된 현장타설말뚝의 허용 주면지지력과 허용 선단지지력을 각각 $8.6t/m^2 \;와 \;84t/m^2$로 제안하였으며, 일축압축강도를 이용한 풍화암의 탄성계수 산정식을 제안하였다.

  • PDF

풍화대소켓 대구경 현장타설말뚝의 선단보강그라우팅 사례 (A Case Study of Post-Grouted Drilled Shaft in Weathered Formation)

  • 권오성;이종성;정성민;이경준;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.415-426
    • /
    • 2010
  • Post-grouting for the drilled shaft is known to increase the end bearing capacity of pile 2~3 times higher by consolidating and reinforcing the disturbed ground containing slime around the pile end. However, the general design guideline for post-grouting has not been established yet in Korea. Especially in the domestic application, the post-grouting is employed just for repairing the pile with the unacceptable resistance rather than for increasing the design resistance of pile. Therefore, little is reported about the effect of post-grouting on the pile resistance itself. In this study, the effect of post-grouting on the resistance of drilled shafts installed in the weathered rock in Korea was estimated by performing the bi-directional load tests on the piles with and without the post-grouting. The test results presented that the initial slope of end bearing-base displacement curve in the pile with post-grouting was 4 times higher than that without post-grouting. At the acceptable settlement (1% of pile diameter), the end bearing capacities of piles with and without the post-grouting were estimated to be 12.0 MPa and 7.0 MPa, respectively, indicating that the post-grouting could increase the end bearing resistance of pile in weathered rock more than 70%.

  • PDF

피복 콘크리트의 균열 발생에 기인한 매크로셀 부식 환경하에서의 Cr강방식철근의 방식성 (Corrosion Resistance of Cr-bearing Rebar to Macrocell Corrosion Caused by Concrete with Crack)

  • 태성호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권4호
    • /
    • pp.79-86
    • /
    • 2006
  • 피복 콘크리트의 균열 발생에 기인한 매크로셀 부식 환경하에서의 Cr강방식철근의 방식성을 평가하기 위하여 10종류의 Cr강방식철근을 콘크리트에 매입 후 피복 콘크리트에 모사 균열을 발생시킨 공시체를 제작하였다. 그 후 염수 분무 촉진 양생 105사이클까지의 매크로셀 부식전류밀도의 경시변화와 아노드 캐소드 철근의 자연전위, 부식면적률, 부식감량률을 측정함으로써 Cr강방식철근의 방식성에 대하여 검토하였다. 그 결과, 염화물 이온 농도차 $3kg/m^3$ 이하의 매크로셀 부식 환경에 대하여 Cr함유율 9% 이상의 Cr강재에서 방식성이 확인되었으며 특히, Cr함유율 11% 이상의 Cr강재에서 뛰어난 방식성이 입증되었다.