• 제목/요약/키워드: beam-column connections

검색결과 492건 처리시간 0.024초

Effect of post weld treatment on cracking behaviors of beam-column connections in steel bridge piers

  • Jia, Liang-Jiu;Ge, Hanbin;Suzuki, Toshimitsu
    • Steel and Composite Structures
    • /
    • 제17권5호
    • /
    • pp.687-704
    • /
    • 2014
  • A great number of moment-resisting steel structures collapsed due to ductile crack initiation at welded beam-column connections, followed by explosive brittle fracture in the Kobe (Hyogoken-Nanbu) earthquake in 1995. A series of experimental and numerical studies on cracking behaviors of beam-column connections in steel bridge piers were carried out by the authors' team. This paper aims to study the effect of post weld treatment on cracking behaviors of the connections during a strong earthquake event. Experiments of three specimens with different weld finishes, i.e., as-welded, R-finish, and burr grinding, were conducted. The experimental results indicate that the instants of ductile crack initiation are greatly delayed for the specimens with R-finish and burr grinding finishes compared with the as-welded one. The strain concentration effect in the connection is also greatly reduced in the specimens with post weld treatment compared with the as-welded one, which was also verified in the tests.

Behaviour of bolted connections in concrete-filled steel tubular beam-column joints

  • Beena, Kumari;Naveen, Kwatra;Shruti, Sharma
    • Steel and Composite Structures
    • /
    • 제25권4호
    • /
    • pp.443-456
    • /
    • 2017
  • Many authors have established the usefulness of concrete filled steel tubular (CFST) sections as compression members while few have proved their utility as flexural members. To explore their prospective as part of CFST frame structures, two types of connections using extended end plate and seat angle are proposed for exterior joints of CFST beams and CFST columns. To investigate the performance and failure modes of the proposed bolted connections subjected to static loads, an experimental program has been executed involving ten specimens of exterior beam-to-column joints subjected to monotonically increasing load applied at the tip of beam, the performance is appraised in terms of load deformation behaviour of joints. The test parameters varied are the beam section type, type and diameter of bolts. To validate the experimental behaviour of the proposed connections in CFST beam-column joints, finite element analysis for the applied load has been performed using software ATENA-3D and the results of the proposed models are compared with experimental results. The experimental results obtained agree that the proposed CFST beam-column connections perform in a semi-rigid and partial strength mode as per specification of EC3.

Central angle effect on connection behavior of steel box beam-to-circular column

  • Hwang, Won-Sup;Kim, Young-Pil;Yoon, Tae-Yang
    • Structural Engineering and Mechanics
    • /
    • 제32권4호
    • /
    • pp.531-547
    • /
    • 2009
  • This paper presents the experimental results on the strength behavior and failure modes of box beam-to-circular column connections in steel piers. Previous research introduced parameters such as joint central angles, extension of horizontal stiffeners, and use of equivalent web depth, which ignored strength behavior and failure modes of box beam-to-circular column connections. The use of equivalent web depth $d_2$ is not reasonable when central angle ${\alpha}$ is closer to $90^{\circ}$; therefore, a monotonic loading test has been performed for eight connection specimens. From the test, it is identified that the connection with the circular column is stronger than the connection with the box-sectioned substitution column. Also, the strength of the beam-to-column connections with horizontal stiffeners is higher than the one of the no column stiffeners. The concrete-filled effect of box beam-to-circular column connection is also investigated, and the experimental yield strength of the connection is compared with the theoretical one. Also, more a reasonable equivalent web depth is suggested. The failure modes of connection are clearly defined.

Development of a Shear Strength Equation for Beam-Column Connections in Reinforced Concrete and Steel Composite Systems

  • Choi, Yun-Chul;Moon, Ji-Ho;Lee, Eun-Jin;Park, Keum-Sung;Lee, Kang Seok
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.185-197
    • /
    • 2017
  • In this study, we propose a new equation that evaluates the shear strength of beam-column connections in reinforced concrete and steel beam (RCS) composite materials. This equation encompasses the effect of shear keys, extended face bearing plates (E-FBP), and transverse beams on connection shear strength, as well as the contribution of cover plates. Mobilization coefficients for beam-column connections in the RCS composite system are suggested. The proposed model, validated by statistical analysis, provided the strongest correlation with test results for connections containing both E-FBP and transverse beams. Additionally, our results indicated that Architectural Institute of Japan (AIJ) and Modified AIJ (M-AIJ) equations should be used carefully to evaluate the shear strength for connections that do not have E-FBP or transverse beams.

Experimental seismic behavior of RC special-shaped column to steel beam connections with steel jacket

  • Hao, Jiashu;Ren, Qingying;Li, Xingqian;Zhang, Xizhi;Ding, Yongjun;Zhang, Shaohua
    • Steel and Composite Structures
    • /
    • 제45권1호
    • /
    • pp.101-118
    • /
    • 2022
  • The seismic performance of the reinforced concrete (RC) special-shaped column to steel beam connections with steel jacket used in the RC column to steel beam fabricated frame structures was investigated in this study. The three full-scale specimens were subjected to cyclic loading. The failure mode, ultimate bearing capacity, shear strength capacity, stiffness degradation, energy dissipation capacity, and strain distribution of the specimens were studied by varying the steel jacket thickness parameters. Test results indicate that the RC special-shaped column to steel beam connection with steel jacket is reliable and has excellent seismic performance. The hysteresis curve is full and has excellent energy dissipation capacity. The thickness of the steel jacket is an important parameter affecting the seismic performance of the proposed connections, and the shear strength capacity, ductility, and initial stiffness of the specimens improve with the increase in the thickness of the steel jacket. The calculation formula for the shear strength capacity of RC special-shaped column to steel beam connections with steel jacket is proposed on the basis of the experimental results and numerical simulation analysis. The theoretical values of the formula are in good agreement with the experimental values.

Effect of bolted splice within the plastic hinge zone on beam-to-column connection behavior

  • Vatansever, Cuneyt;Kutsal, Kutay
    • Steel and Composite Structures
    • /
    • 제28권6호
    • /
    • pp.767-778
    • /
    • 2018
  • The purpose of this study is to investigate how a fully restrained bolted beam splice affects the connection behavior as a column-tree connection in steel special moment frames under cyclic loading when located within the plastic hinge zone. The impacts of this attachment in protected zone are observed by using nonlinear finite element analyses. This type of splice connection is designed as slip-critical connection and thereby, the possible effects of slippage of the bolts due to a possible loss of pretension in the bolts are also investigated. The 3D models with solid elements that have been developed includes three types of connections which are the connection having fully restrained beam splice located in the plastic hinge location, the connection having fully restrained beam splice located out of the plastic hinge and the connection without beam splice. All connection models satisfied the requirement for the special moment frame connections providing sufficient flexural resistance, determined at column face stated in AISC 341-16. In the connection model having fully restrained beam splice located in the plastic hinge, due to the pretension loss in the bolts, the friction force on the contact surfaces is exceeded, resulting in a relative slip. The reduction in the energy dissipation capacity of the connection is observed to be insignificant. The possibility of the crack occurrence around the bolt holes closest to the column face is found to be higher for the splice connection within the protected zone.

철골 보-기둥 접합부의 내진성능 개선을 위한 실험적 연구 (An Experiemetal Study for Improvement of Seismic Performance of Steel Beam-to-Column Connections)

  • 이승준;김원기;이정웅
    • 한국지진공학회논문집
    • /
    • 제3권4호
    • /
    • pp.61-70
    • /
    • 1999
  • 1994년 Northridge 지진과 1995년 Kobe 지진에서 많은 철골구조물의 보-기둥 접합부에 발생한 규열은 내진성능이 우수한 것으로 알려진 모멘트 저항 철골골조의 내진성능 개선에 대한 연구필요성을 제시하였다 일반적으로 모멘트 저항 골조가 강한 지진을 받을 때 보-기둥 접합부는 강도의 저하없이 소성 회전변형능력이 0.015이면 만족할 수 있다고 한다. 본 연구의 목적은 강한 지진하중에서도 철골구조의 보-기둥 접합부에서 용접부의 균열이 방지되고 연성적으로 충분한 에너지를 흡수하고 소산할 수 있는 접합부의 형태를 제안하고 그 거동을 조사하는 것이다 본 연구에서는 접합부의 형태를 제안하였으며 실험을 통하여 그 거동을 분석하였다 제안된 접합부 시험체에 대한 실험결과는 용접부에 균열이 발생하지 않았으며충분한 변형능력을 나타냈다.

  • PDF

A Simplified Steel Beam-To-Column Connection Modelling Approach and Influence of Connection Ductility on Frame Behaviour in Fire

  • Shi, Ruoxi;Huang, Shan-Shan;Davison, Buick
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.343-362
    • /
    • 2018
  • A simplified spring connection modelling approach for steel flush endplate beam-to-column connections in fire has been developed to enable realistic behaviour of connections to be incorporated into full-scale frame analyses at elevated temperature. Due to its simplicity and reliability, the proposed approach permits full-scale high-temperature frame analysis to be conducted without high computational cost. The proposed simplified spring connection modelling approach has been used to investigate the influence of connection ductility (both axial and rotational) on frame behaviour in fire. 2D steel and 3D composite frames with a range of beam spans were modelled to aid the understanding of the differences in frame response in fire where the beam-to-column connections have different axial and rotational ductility assumptions. The modelling results highlight that adopting the conventional rigid or pinned connection assumptions does not permit the axial forces acting on the connections to be accurately predicted, since the axial ductility of the connection is completely neglected when the rotational ductility is either fully restrained or free. By accounting for realistic axial and rotational ductilities of beam-to-column connections, the frame response in fire can be predicted more accurately, which is advantageous in performance-based structural fire engineering design.

철골 모멘트 접합부에서 웨브의 모멘트 전달효율과 변형도 집중과의 관계에 관한 해석적 연구 (Analytical Study on Relationship Between Moment Transfer Efficiency of a Beam Web and Strain Concentration at Steel Moment Connections)

  • 김영주;오상훈;문태섭
    • 한국강구조학회 논문집
    • /
    • 제16권5호통권72호
    • /
    • pp.695-703
    • /
    • 2004
  • 본 논문에서는 4개의 철골 해석모델과 1개의 합성보 해석모델에 대한 단조가력 해석의 결과를 나타냈다. 철골 기둥-보 접합부에서 웨브의 모멘트 전달효율과 변형도 집중에 대해서 조사하였다. 해석결과 각형기둥을 가진 모델의 모멘트 전달효율은 각형기둥 플랜지의 면외변형 때문에 H-기둥을 가진 모델에 비해서 빈약했다. 스캘럽과 얇은 각형기둥 두께 및 슬래브도 또한 모멘트 전달효율의 저하를 가져오는 원인으로서, 이는 보-기둥 접합부의 파단을 초래할 가능성이 크다. 해석 결과는 실험결과와 비교하였다. 실험결과를 기초로 하면, 각형기둥 또는 슬래브가 있는 접합부의 변형능력은 빈약한 모멘트 전달효율과 이에 따른 플랜지의 변형도 집중에 의해 감소했다.

Layered finite element method in cracking and failure analysis of RC beams and beam-column-slab connections

  • Guan, Hong;Loo, Yew-Chaye
    • Structural Engineering and Mechanics
    • /
    • 제5권5호
    • /
    • pp.645-662
    • /
    • 1997
  • A nonlinear semi-three-dimensional layered finite element procedure is developed for cracking and failure analysis of reinforced concrete beams and the spandrel beam-column-slab connections of flat plates. The layered element approach takes the elasto-plastic failure behaviour and geometric nonlinearity into consideration. A strain-hardening plasticity concrete model and a smeared steel model are incorporated into the layered element formulation. Further, shear failure, transverse reinforcement, spandrel beams and columns are successfully modelled. The proposed method incorporating the nonlinear constitutive models for concrete and steel is implemented in a finite element program. Test specimens including a series of reinforced concrete beams and beam-column-slab connections of flat plates are analysed. Results confirm the effectiveness and accuracy of the layered procedure in predicting both flexural and shear cracking up to failure.