• 제목/요약/키워드: beam expander

검색결과 22건 처리시간 0.026초

산업용 SFF 시스템에서 Laser Beam Spot size 측정 메커니즘 개발 (Development of Measurement mechanism of Laser Beam Spot size for Industrial SFF system)

  • 배성우;김동수;최경현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1383-1388
    • /
    • 2007
  • Accuracy and processing time are very important factors when the desired shape is fabricated with Selective Laser Sintering (SLS), one of Solid Freeform Fabrication (SFF) systems. In a conventional SLS process, laser spot size is fixed during laser exposing on the sliced figure. Therefore, it is difficult to accurately and rapidly fabricate the desired shape. In this paper, to deal with those problems an SFF system having ability of changing spot size is developed. The system provides high accuracy and optimal processing time. Specifically, a variable beam expander is employed to adjust spot size for different figures on a sliced shape. Finally, Design and performance estimation of the SFF system employing a variable beam expander are achieved and the mechanism will be addressed to measure the real spot size generated from the variable beam expander.

  • PDF

1064 nm 레이저 관원용 2~8X 줌 빔 확대기 개발 (Development of the 2~8X Zoom Beam Expander for the 1064 nm Laser Source)

  • 이명하;이동희
    • 한국안광학회지
    • /
    • 제13권2호
    • /
    • pp.23-28
    • /
    • 2008
  • 목적: 1064 nm용 2.0~8.0X 줌 빔 확대기의 개발. 방법: 3군 줌 궤적에 대한 초기 설계 값을 신속하게 확보할 수 있는 프로그램을 개발하고, 이 프로그램과 Sigma 2000 상용프로그램을 활용하여 줌 빔 확대기를 설계 개발한다. 결과: 3군 줌 궤적에 대한 초기 설계 값을 신속하게 확보할 수 있는 프로그램을 개발하여, 이 프로그램과 상용프로그램 Sigma 2000을 활용하여 2배에서 8배까지 줌이 가능한 1064 nm용 줌 빔 확대기를 설계 개발하였다. 개발된 줌 빔 확대기는 입사측 유효경이 8 mm이고 출사측 유효경이 32 mm이며 유한광선 수차량이 0.0001 rad 이내인 성 능을 갖게 되었다. 전체 시스템의 렌즈 총 길이가 125 mm에서 135 mm 사이가 되도록 제한하였기 때문에 줌 구동의 변화로 인한 전체 경통의 길이 변화는 10 mm 이내로 되었다. 결론: 3군 줌 궤적에 대한 초기 설계 값을 신속하게 확보할 수 있는 프로그램을 개발하여 2배에서 8배까지 줌이 가능한 1064 nm용 줌 빔 확대기를 설계 개발하였다.

  • PDF

Assessment of Temporary Radioactivation for Tissue Expanders in Breast Radiation Therapy: Preliminary Study

  • Hwajung Lee;Do Hoon Oh;Lee Yoo;Minsoo Chun
    • Journal of Radiation Protection and Research
    • /
    • 제48권2호
    • /
    • pp.100-106
    • /
    • 2023
  • Background: As breast tissue expanders consist of metallic materials in the needle guard and ferromagnetic injection port, irradiation can produce radioactivation. Materials and Methods: A CPX4 (Mentor Worldwide LLD) breast tissue expander was exposed using the Versa HD (Elekta) linear accelerator. Two photon energies of 6 and 10 MV-flattening filter free (FFF) beams with 5,000 monitor units (MU) were irradiated to identify the types of radiation. Furthermore, 300 MU with 10 MV-FFF beam was exposed to the CPX4 breast tissue expander by varying the machine dose rates (MDRs) 600, 1,200, and 2,200 MU/min. To assess the instantaneous dose rates (IDRs) solely from the CPX4, a tissue expander was placed outside the treatment room after beam irradiation, and a portable radioisotope identification device was used to identify the types of radiation and measure IDR. Results and Discussion: After 5,000 MU delivery to the CPX4 breast tissue expander, the energy spectrum whose peak energy of 511 keV was found with 10 MV-FFF, while there was no resultant one with 6 MV-FFF. The time of each measurement was 1 minute, and the mean IDRs from the 10 MV-FFF were 0.407, 0.231, and 0.180 μSv/hr for the three successive measurements. Following 10 MV-FFF beam irradiation with 300 MU indicated around the background level from the first measurement regardless of MDRs. Conclusion: As each institute room entry time protocol varies according to the working hours and occupational doses, we suggest an addition of 1 minute from the institutes' own room entry time protocol in patients with CPX4 tissue expander and the case of radiotherapy vaults equipped with a maximum energy of 10 MV photon beams.

줌렌즈 광속확대기를 적용한 레이저 레이더용 송수광 내접형 광학계 설계 (Inscribed Transceiver Optical System Design for Laser Radar with Zoom-type Expander)

  • 고해석;옥창민;홍진석;이창재;박찬근;김현규
    • 한국광학회지
    • /
    • 제24권1호
    • /
    • pp.23-28
    • /
    • 2013
  • 송광광학계의 광원으로 사용되는 광섬유 레이저의 개구수, NA가 0.13~0.22의 범위에 있으면, 이 NA에 관계없이 1 km 전방에서 빔직경이 4.8 m 또는 6.8 m이 되도록 줌렌즈형 광속확대기를 적용한 송광광학계를 설계하였으며, 표적에서의 foot prints를 통하여 빔직경을 확인하였다. $16{\times}16$($100{\mu}m{\times}100{\mu}m$) 픽셀 검출기를 사용하는 수광광학계를 설계하였으며, 검출면의 픽셀 위치에 따른 spot diameter는 모두 $55{\mu}m$ 이하가 됨을 확인하였다. 스캔을 고려하여 송광광학계를 수광부 대물렌즈에 내접하도록 구성하였으며, 이때 송광부에 의하여 가려진 부분은 11%가 되었다.

연속파 Nd:YAG 레이저를 이용한 치아교정 급속 구개확장장치 용접특성 (Welding Characteristics of Rapid Palatal Expander for Teeth Calibration using a Continuous Wave Nd:YAG Laser)

  • 유영태;양윤석;신호준
    • 한국정밀공학회지
    • /
    • 제27권2호
    • /
    • pp.40-49
    • /
    • 2010
  • The Purpose of this paper is to weld a rapid palatal expander using a continuous wave Nd:YAG laser. The rapid palatal expander has become a useful treatment method for severe maxillary transverse deficiencies and posterior crossbites. Rapid maxillary expansion is a well-established method to correct transverse maxillary deficiency and arch length discrepancy. The major process parameters studied in the present laser welding experiment were the positions of focus, laser power and travel speed of laser beam. We measured the fusion zone size and its shape using an optical microscope for the observation of cross-sectional area and tension stress of a rapid palatal expander welded. Through the experimental investigation, the optimum speeds and power of laser without deficiencies of weld cross-sectional area were obtained.

Pattern of microimplant displacement during maxillary skeletal expander treatment: A cone-beam computed tomography study

  • Ney Paredes;Ausama Gargoum;Ramon Dominguez-Mompell;Ozge Colak;Joseph Bui;Tam Duong;Maya Giannetti;Fernanda Silva;Kendra Brooks;Won Moon
    • 대한치과교정학회지
    • /
    • 제53권5호
    • /
    • pp.289-297
    • /
    • 2023
  • Objective: To analyze the microimplant (MI) displacement pattern on treatment with a maxillary skeletal expander (MSE) using cone-beam computed tomography (CBCT). Methods: Thirty-nine participants (12 males and 27 females; mean age, 18.2 ± 4.2 years) were treated successfully with the MSE II appliance. Their pre- and post-expansion CBCT data were superimposed. The pre- and post-expansion anterior and posterior inter-MI angles, neck and apical inter-MI distance, plate angle, palatal bone thickness at the MI positions, and suture opening at the MI positions were measured and compared. Results: The jackscrew plate was slightly bent in both anterior and posterior areas. There was no significant difference in the extent of suture opening between the anterior and posterior MIs (P > 0.05). The posterior MI to hemiplate line was greater than that anteriorly (P < 0.05). The apical distance between the posterior MIs was greater than that anteriorly (P < 0.05). The palatal thickness at the anterior MIs was significantly greater than that posteriorly (P > 0.01). Conclusions: In the coronal plane, the angulation between the anterior MIs in relation to the jackscrew plate was greater than that between the posterior MIs owing to the differential palatal bone thickness.

갈바노미터 스캐너를 이용한 레이저 마킹 시스템 설계 제작에 관한 연구 (A study on the design of the laser marking system using galvanometer scanner)

  • 조태익;이건이
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.145-148
    • /
    • 1986
  • To perform the marking on metal with high speed and non-contact using the laser beam of high energy, laser marking system is designed and fabricated applying the galvanometer scanner capable of high speed-precise beam positioning controlled by microprocessor. Laser is a Q-switched Nd:YAG producing multi-mode, wavelength, 1060nm. Optical system is composed of beam expander, scanning mirror and flat field lens. Consequently, the laser marking is satisfactorily achieved regardless of kinds of metal.

  • PDF

비정질 칼코게나이드 박막에 Surface Relief 격자 형성 (The recording of surface relief grating on the chalcogenide thin film)

  • 박종화;장선주;박정일;여철호;이영종;정홍배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.299-302
    • /
    • 2000
  • In this study, we have made the large holographic surface relief gratings on amorphous chalcogenide $As_{40}$$Ge_{10}$$Se_{15}$$S_{35}$ films by two beam interference using a He-Ne laser(632.8nm) light. The film thickness was about 0.6$\mu\textrm{m}$, we could magnify beam size by using beam expander. We made use $90^{\circ}$ holder which was made of reflection mirror and sample. Formed the surface relief structures were investigated using optical microscope. The diffraction efficiency was obtained by measuring +lst order intensity. In addition we investigated grating formation and diffraction efficiency as a function of polarization states which is linear or circular polarization. The results indicate that the grating was formed by linear polarized beam is better clear than that by circular polarized beam.

  • PDF