• Title/Summary/Keyword: beam attenuation coefficient

Search Result 48, Processing Time 0.042 seconds

Derivation of Photon Energy Fluence and Mass Energy Absorption Coefficient for 1 Gy Absorbed Dose of Water in Brachytherapy using Ir192 Source (Ir192 선원을 이용한 근접치료에서 물 흡수선량 1 Gy에 대한 광자에너지 플루언스와 질량에너지흡수계수 유도)

  • Kim, Jong-Eon;Ahn, Il-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.61-66
    • /
    • 2022
  • The purpose of this study is to derive photon energy fluence and mass energy absorption coefficient for 1 Gy of absorbed dose of water in brachytherapy using an Ir192 source. From the radiotherapy physics written by Khan, the half-value of lead for the gamma ray beam of the Ir192 source was obtained. The linear attenuation coefficient and the mass attenuation coefficient were calculated from the obtained half-value layer of lead. By matching the calculated lead mass attenuation coefficient with the NIST mass attenuation coefficient data, the photon energy of the matching mass attenuation coefficient was determined as the effective energy. By matching the determined effective energy with the photon energy of the NIST data on the mass energy absorption coefficient of water, the mass energy absorption coefficient of water was obtained as 0.03273 cm2/g(32.73 cm2/kg). The photon energy fluence was calculated as 0.03055 J/cm2 by dividing the obtained mass energy absorption coefficient (32.73 cm2/kg) by the absorbed dose of water 1 Gy.

Evaluation of the Effect of Metal Artifacts Varying the Parameters of the Attenuation Map for the artificial Hip Joint in SPECT/CT (SPECT/CT에서 인공고관절에 대한 감쇠보정지도(Attenuation Map)의 매개변수 변화에 따른 금속 인공물(Metal Artifact)의 영향 평가)

  • Kim, Sang Gyu;Kim, Jung Yul;Park, Min Soo;Jo, Seung Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.3-7
    • /
    • 2014
  • Purpose SPECT/CT scan to be performed attenuation correction on the basis of CT induce an overestimation of the site due to the beam hardening artifact by metal cover and reduce the images quality. Therefore, this study using a phantom that has been inserted artificial hip joint investigated that effect on the SPECT/CT image causing by metal artifact for varying the parameters of the Attenuation Map. Materials and Methods Siemens Symbia T16 SPECT/CT equipment was used. Artificial hip joint was inserted to SPECT/PET phantom, 17 mm sphere of Bright Streak area in CT image was filled with Tc-99m so that the radiation activity was 8 times compared to background. And then Hot and Background was measured in varying Wide Beam Coefficient on Attenuation Map and RBR (Region to Background Ratio) of Metal and Non-Metal was calculated and analyzed depending on the presence or absence of the hip joint. Results It tended to hot count of Non-Metal and Metal to increase as the value of the manual mode is increased, hot count ratio with the group of both manual mode 0.5 and 0.4 is the best match. Also, in automatic mode, the ratio of RBRNon-Metal and RBRMetal was 1.135, statistically significant difference was not observed in the manual mode 0.5 and 0.4. Conclusion In the automatic mode of Wide Beam Coefficient in attenuation correction map, it was found that it is over-correction by 13.52%, it was possible to minimize the over-correction by the artifact in 0.5 and 0.4 of manual mode. Further studies should be performed in order to apply to a patient with the help of this and it is considered possible to reduce the over-correction by the metal artifact of an artificial hip joint for Hip-Resurfacing Arthroplasty patients, and to improve the diagnostic performance.

  • PDF

Characteristic of In Situ Suspended Particulate Matter at the Gwangyang bay Using LISST-100 and ADCP (LISST-100과 ADCP를 이용한 광양만 현장 부유입자물질 특성 연구)

  • Lee, Byoung-Kwan;Kim, Seok-Yun
    • Journal of Environmental Science International
    • /
    • v.18 no.11
    • /
    • pp.1299-1307
    • /
    • 2009
  • In order to measure in-situ suspended particle size, volume concentration of suspended particulate matter and current speed, mooring observation was performed at the Gwangyang Bay by using of an optical instrument, 'LISST-100' and an acoustic instrument, 'ADV'(St. S1). And the sediment flux was obtained based on the concentration of suspended particulate matter and current speeds measured at three lines of Gwangyang Bay during ebb and flood tide of August 2006. To investigate the spatial variation of suspended particulate matter, profiling observations were measured difference echo intensity and beam attenuation coefficient by using of ADCP and Transmissometer (Line A, B, C). The suspended sediment flux rate at the mouth of Gwangyang Bay was observed to be higher during asymmetrical than symmetrical of current speeds. The flux of suspended particulate matter concentration and current speeds were transported to southeastern direction of surface layer and northwestern direction of bottom layer at the western area at line A of Gwangyang Bay. Small suspended particles have been found to increase attenuation and transmission more efficiently than similar large particles using acoustic intensity (ADV/ADCP) or optical transmit coefficient (LISST-100/Transmissometer). The application and problems as using optical or acoustic instruments will be detected for use in time varying calibrations to account for non-negligible changes in complex environments in situ particle dynamics are poorly understood.

Hybrid model-based and deep learning-based metal artifact reduction method in dental cone-beam computed tomography

  • Jin Hur;Yeong-Gil Shin;Ho Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2854-2863
    • /
    • 2023
  • Objective: To present a hybrid approach that incorporates a constrained beam-hardening estimator (CBHE) and deep learning (DL)-based post-refinement for metal artifact reduction in dental cone-beam computed tomography (CBCT). Methods: Constrained beam-hardening estimator (CBHE) is derived from a polychromatic X-ray attenuation model with respect to X-ray transmission length, which calculates associated parameters numerically. Deep-learning-based post-refinement with an artifact disentanglement network (ADN) is performed to mitigate the remaining dark shading regions around a metal. Artifact disentanglement network (ADN) supports an unsupervised learning approach, in which no paired CBCT images are required. The network consists of an encoder that separates artifacts and content and a decoder for the content. Additionally, ADN with data normalization replaces metal regions with values from bone or soft tissue regions. Finally, the metal regions obtained from the CBHE are blended into reconstructed images. The proposed approach is systematically assessed using a dental phantom with two types of metal objects for qualitative and quantitative comparisons. Results: The proposed hybrid scheme provides improved image quality in areas surrounding the metal while preserving native structures. Conclusion: This study may significantly improve the detection of areas of interest in many dentomaxillofacial applications.

Distribution and Behaviors of In-Situ Suspended Particulate Matters of Gwangyang Bay (광양만내의 현장 부유입자물질 분포와 거동)

  • Lee, Byoung-Kwan;Kim, Seok-Yun;Cho, Hyun-Man
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.99-105
    • /
    • 2010
  • The concentration and size analysis of in-situ suspended particulate material were measured using an optical instrument, LISST-100, in the bottom layer at the three inlets of the Seomjin River Estuary, mouth of Gwangyang bay, and Gwangyang bay-side of the Namhae Bridge. In the Seomjin river estuary and mouth of Gwangyang bay-side of the Namhae Bridge, the in-situ mean grain size of the suspended material changed from a uni-modal distribution with a dominant peak at a coarse fraction to a bi-modal distribution with a secondary peak at the finer particles. Seomjin River. The interactions between suspended particulate concentration and beam attenuation coefficient of suspended particulate matters depended on the supply of finer and coarser particles in the mouth of Gwangyang Bay and Seomjin River. So, interactions reflected difference of the concentration, mean size and sorting of suspended particulate matters. The difference of interaction showed dynamic behaviors to the resuspension and deflocculation processes increased river discharge. This showed that it may be possible to use the interactions between the suspended particle concentration and beam attenuation coefficient to monitor the temporal and spatial distributions of in-situ particles.

An effect of the characteristics of incident laser beams on laser-induced incandescence signals (LII 신호에 대한 입사 레이저 특성의 영향)

  • Jurng, Jong-Soo;Lee, Gyo-Woo
    • 한국연소학회:학술대회논문집
    • /
    • 1997.06a
    • /
    • pp.45-50
    • /
    • 1997
  • An experimental study on LII signal images from soot particles in a flame has been carried out in order to investigate the effect of the incident laser characteristics. By changing the wavelength of the incident laser beam, the LII signal was saturated at smaller laser power with 532 nm than 1,064 nm. This implies that the larger absorption coefficient of soot particles at 532 nm would influence the LII signal characteristic. Using the deconvolution technique, the projected LII line images were coverted to reconstruct the local LII signals inside the beam. The results show that the LII images at ICCD camera result from the integration of LII signal across the laser beam.

  • PDF

Investigation of gamma radiation shielding properties of polyethylene glycol in the energy range from 8.67 to 23.19 keV

  • Akhdar, H.;Marashdeh, M.W.;AlAqeel, M.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.701-708
    • /
    • 2022
  • The mass attenuation coefficients (μm) of polyethylene glycol (PEG) of different molecular weights (1000-200,000) were measured using single-beam photon transmission. The X-ray fluorescent (XRF) photons from Zinc (Zn), Zirconium (Zr), Molybdenum (Mo), Silver (Ag) and Cadmium (Cd) targets were used to determine the attenuation of gamma radiation of energy range between 8.67 and 23.19 keV in PEG samples. The results were compared to theoretical values using XCOM and Monte Carlo simulation using Geant4 toolkit which was developed to validate the experiment at those certain energies. The mass attenuation coefficients were then used to compute the effective atomic numbers, electron density and half value layers for the studied samples. The outcomes showed good agreement between experimental and simulated results with those calculated theoretically by XCOM within 5% deviation. The PEG 1000 sample showed slightly higher μm value compared with the other samples. The dependence of the photon energy and PEG composition on the values of μm and HVL were investigated and discussed. In addition, the values of Zeff and Neff for all PEG samples behaved similarly in the given photon energy range, and they decreased as the photon energy increased.

Use of Beam Transmissometer as an Indirect Measure of Suspended Sediment Concentration in the Estuarine Environment: Application and Problems (강하구에서의 부유물질농도 결정을 위한 광전도측정기의 이용 및 문제점)

  • KIM Seok-Yun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.6
    • /
    • pp.771-781
    • /
    • 1994
  • Monthly measurements made at 15 stations along the axis of the upper Neuse River estuary show a highly variable degree of correlation between concentration of suspended particulate material (SPM) and attenuation coefficient (c) of light as measured by transmissometer. Coefficients of determination along transect lines ranged from $0.12{\sim}0.93$ and calibration slopes ranged from $0.50{\sim}5.63$. When examined on a station-by-station basis, coefficients of determination ranged from $0.21{\sim}0.96$ and calibration slopes ranged from $1.04{\sim}4.94$. Surface calibrations made at individual stations over the full 13-month period were the most consistent of all observations and were considerably better than calibrations made using all of the stations on a given day. Organic content, which can dominate the suspended sediment load during some months, does not appear to explain the variations in reliability of the calibrations. However, an abundance of large aggregates with time-varying size and shape distributions may be partly responsible for variations in optical properties of the sediments, and thus may confound the relationship between SPM and c in the Neuse River estuary Time-varying calibrations to account for non-negligible changes in optical properties may not suffice in complex estuarine environments where the in situ particle dynamics are poorly understood. However, the best use of Beam Transmissometer will continue to be for applications such as detecting water-column events or for use in situations where wide error bars in establishing SPM concentrations are acceptable.

  • PDF

Characteristics of 23 MV Photon Beam from a Mevatron KD 8067 Dual Energy Linear Accelerator (Mevatron KD 8067 선형가속기의 23 MV 광자선의 특성)

  • Kim, Ok-Bae;Choi, Tae-Jin;Kim, Young-Hoon
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.115-124
    • /
    • 1990
  • The characteristics of 23 MV photon beam have been presented with respect to clinical parameters of central axis depth dose, tissue-maxi mum ratios, scatter-maximum ratios, surface dose and scatter correction factors. The nominal accelerating potential was found to be $18.5\pm0.5$ MV on the central axis. The half-value layer (HVL) of this photon beam was measured with narrow beam geometry from central axis, and it has been showed the thickness of $24.5\;g/cm^2$. The tissue-maximum ratio values have been determined from measured percentage depth dose data. In our experimental dosimetry, the surface dose of maximum showed only $9.6\%$ of maximum dose at $10\times10\;cm^2$, 100 cm SSD, without blocking tray in. The TMR'S of $0\times0$ field size have been determined to get average $2.3\%$ uncertainties from three different methodis; are zero effective attenuation coefficient, non-ilnear least square fit of TMR's data and effective linear attenuation coefficient from the HVL of 23 MV photon beams of dual energy linear accelerator.

  • PDF

Attenuation Estimation of Soft Tissue by the Entropy Method and Statistical Averaging of Speckle Patterns (스펙클 패턴의 통계적 평균과 엔트로피 방식에 의한 초음파 감쇄계수 추정방법)

  • Song, T.K;Park, J.C;Park, S.B
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.253-260
    • /
    • 1989
  • The time domain methods of estimating the attenuation coefficient are generally based on the analysis of statisical properties of the reflected echoes form an attenuating medium. Hence, it is often required to have a large number of data samples in order to obtain a statistically stable estimation result. In the attenuation estimation problem, this means that many different speckle patterns are required in the spatial resolution volume of an attenLlation image. In this paper, by using the fact that the speckle pattern Is sensitive to the point spread function of the ultrasound beam, we suggest a method to generate the statiscally uncorrelated or slightly correlated data samples in a given region by rotating a linear transducer and carrying out lateral scans for all rotating angles. This technique is applied to the entropy method for attenuation estimation proposed recently by the authors where the performance is verified by experiments using a tissue equivalent phantom.

  • PDF