• Title/Summary/Keyword: basic structure

Search Result 4,451, Processing Time 0.026 seconds

A New Symmetric Cascaded Multilevel Inverter Topology Using Single and Double Source Unit

  • Mohd. Ali, Jagabar Sathik;Kannan, Ramani
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.951-963
    • /
    • 2015
  • In this paper, a new symmetric multilevel inverter is proposed. A simple structure for the cascaded multilevel inverter topology is also proposed, which produces a high number of levels with the application of few power electronic devices. The symmetric multilevel inverter can generate 2n+1 levels with a reduced number of power switches. The basic unit is composed of a single and double source unit (SDS-unit). The application of this SDS-unit is for reducing the number of power electronic components like insulated gate bipolar transistors, freewheeling diodes, gate driver circuits, dc voltage sources, and blocked voltages by switches. Various new algorithms are recommended to determine the magnitude of dc sources in a cascaded structure. Furthermore, the proposed topology is optimized for different goals. The proposed cascaded structure is compared with other similar topologies. For verifying the performance of the proposed basic symmetric and cascaded structure, results from a computer-based MATLAB/Simulink simulation and from experimental hardware are also discussed.

Basic Design of Deep Subsea Manifold Frame Structure for Oil Production (심해저 원유 생산용 매니폴드 프레임 구조 기본 설계)

  • Park, Se-Yung;Choung, Joonmo
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.3
    • /
    • pp.207-216
    • /
    • 2015
  • Amanifold is one of the essential subsea oil and gas production components to simplify the subsea production layout. It collects the production fluid from a couple of wellheads, transfers it to onshore or offshore storage platforms, and even accommodates water and gas injection flowlines. This paper presents the basic design procedure for a manifold frame structure with novel structural verification using in-house unity check codes. Loads and load cases for the design of an SIL 3 class-manifold are established from a survey of relevant industrial codes. The basic design of the manifold frame is developed based on simple load considerations such as the self weights of the manifold frame and pipeline system. In-house software with Eurocode 3 embedded, called INHA-SOLVER, makes it possible to carry out code checks on the yield and buckling unities. This paper finally proves that the new design of the manifold frame structure is effective to resist a permanent and environment load, and the in-house code is also adaptively combined with the commercial finite element code Nastran.

Analysis of Korean Fashion Design Seunghee Suh from the Viewpoint of Simulacre (시뮬라크르 관점에서의 한국적 패션디자인 분석)

  • Suh, Seunghee;Kim, Hanna
    • Journal of Fashion Business
    • /
    • v.23 no.5
    • /
    • pp.19-30
    • /
    • 2019
  • The aim of this study is to analyze the stage of image change in Korean fashion design in regards to the simulacre of Jean Baudrillard. The changing phases of Korean fashion design are as follows: First, the initial stage involved simple imitation, which replicated the original as much as possible, it expressed the basic composition of Hanbok, flat cut and rich silhouette, the color scheme of traditional colors, traditional patterns, materials, and traditional ornaments. In the second stage, the subject matter intervened to distort and transform from the original, the basic composition and structure of the Hanbok were barely maintained, they were either removed or part of the structure modified or expressed using modern materials and patterns. The third stage, were based on reality but differed from reality through subject and imagination, and only left a part of the basic composition of Hanbok, and were expressed through the partial modification of the elements of the Hanbok, for instance the silhouette, skirt waist, collar and breast-tie. The fourth stage of pure simulacre, which refers to a new image with complete independence regardless of the reality. This stage differed from the basic structure and composition of Hanbok, and showcased traditional Korean image of Korea's unique cultural elements, such as hanbok or crafts and artworks, in a modern fashion with a modern sense and practicality.

A Debate on the Use of Presaturation Method in NMR for Structure Determination of Polypeptides in $H_2O$

  • Lee, Chulhyun;Yi, Gwan-Su;Kim, Eun-Hee;Lee, Jo-Woong;Chagjoon Cheong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.1 no.1
    • /
    • pp.21-29
    • /
    • 1997
  • Three typical solvent suppression methods employed for measuring the NOE data that are used for structure determination of polypeptides by modeling were discussed and compared with one another. In the experiments with several peptides composed of 10 to 65 amino acids the presaturation method was found to give severely distorted signal intensities of exchangeable protons, thus making the results based on this method much less reliable.

  • PDF

Wage Structure in Hospitals (병원의 임금체계 실태 - 부산시내 병원을 중심으로 -)

  • Kim, Jung-Hwa;Park, Jun-Han;Lee, Key-Hyo
    • Korea Journal of Hospital Management
    • /
    • v.2 no.1
    • /
    • pp.162-182
    • /
    • 1997
  • This study was carried out to assess the current status of hospital wage structure and to find out the characteristics and problems in the current hospital wage structure. so as to provide empirical data for establishing a rational wage structure. The data were collected from administrative personnels in charge of wage management in 31 hospitals by using a structured questionnaire through direct visiting and mailing in Pusan Metropolitan City. The major findings in this study were as follows: First, the hospital wage structure applied differently to the basic wages between doctors and the other employees. The wage structure for doctors included performance rate of 51.6%, followed by a synthesis rate of 29.0%, while the wage for the other employees had the synthesis rate of 74.2%, followed by the seniority rate of 12.9%. Second, the wage consisted of a basic wage for 57.5%. the allowance for 21.1% and monthly installed bonus for 21.4%, and the basic wage comprised 68.3% of the total wage for doctors, as compared to 51.9% for nurses and medical technicians and 52.4% for administrative and managerial personnel. The annual rate of the bonus was average 460%, and 96.8% of the hospital did not consider personnel preformance appraisal when paying the bonus. Third, 80.6% of the hospitals applied the legal rate to the retirement allowance while 19.4% applying cumulative rates more than the legal rate, and all of university hospitals applied cumulative rates. Retirement reserves were practiced only in 54.9% of the hospitals. Forth, many hospitals seemed to be interested in applying graded wage system according to performance, by showing that 42.9% of the hospitals were planning to apply it in the future, despite only 9.7% practicing it. Fifth, the wage structure appeared to be complicated due to various kinds of allowances. The kind of the allowances varied among hospitals, ranging from 2 to 26 kinds, and increased as the size of hospital was larger. Sixth, the opinions leading to improve the basic wage structure favored the seniority rate for 51.6% either to maintain the present seniority rate(16.1%) or to apply the incentive pay in addition to the senior rate(35.5%). and also favored the performance rate for 35.5%, followed by the job rate for 12.9%. In conclusion, the current hospital wage structure seemed to be too complicated to reflect personal ability, contribution and performance and to become a big barrier to inducing worker's motivation and to strengthening in competitveness. Therefore it is suggested that the current wage structure should be revised to the one emphasizing on job and ability base with considering characteristics and situation of the hospital, rather than seniority factors.

  • PDF

Characteristics of Surface Micromachined Pyroelectric Infrared Ray Focal Plane Array

  • Ryu, Sang-Ouk;Cho, Seong-Mok;Choi, Kyu-Jeong;Yoon, Sung-Min;Lee, Nam-Yeal;Yu, Byoung-Gon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.1
    • /
    • pp.45-51
    • /
    • 2005
  • We have developed surface micromachined Infrared ray (IR) focal plane array (FPA), in which single $SiO_{2}$ layer works as an IR absorbing plate and $Pb(Zr_{0.3}Ti_{0.7})O_{2}$ thin film served as a thermally sensitive material. There are some advantages of applying $SiO_{2}$ layer as an IR absorbing layer. First of all, the $SiO_{2}$ has good IR absorbance within $8{\sim}12{\mu}m$ spectrum range. Measured value showed about 60% absorbance of incident IR spectrum in the range. $SiO_{2}$ layer has another important merit when applied to the top of Pt/PZT/Pt stack because it works also as a supporting membrane. Consequently, the IR absorbing layer forms one body with membrane structure, which simplifies the whole MEMS process and gives robustness Ito the structure.

Performance Analysis of Closed-type OTEC Cycle using Waste Heat (폐열 이용 폐쇄형 해양온도차발전 사이클의 성능)

  • Lee, Ho-Saeng;Jung, Dong-Ho;Hong, Seok-Won;Kim, Hyeon-Ju
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.80-84
    • /
    • 2011
  • The cycle performance of closed ocean thermal energy conversion (OTEC) system with 50 kW gross power was evaluated to obtain the basic data for the optimal design of OTEC using waste heat such as solar power, discharged heat from condenser of power plant. The basic thermodynamic model for OTEC is Rankine cycle, and the surface seawater and deep seawater were used for the heat source of evaporator and condenser, respectively. The cycle performance such as efficiency, heat exchanger capacity, etc. was analyzed on the variation of temperature increase by waste heat. The cycle efficiency increased and necessary capacity of evaporator and condenser decreased under 50kW gross power with respect to the temperature increase of working fluid. Also, when the temperature increase is about $13.5^{\circ}C$, the heat which can be used is generated. By generator with 0.9 effectiveness under the simulated condition, the cycle efficiency was improved approximately 3.0% comparing with the basic cycle.