• Title/Summary/Keyword: base isolation systems

Search Result 142, Processing Time 0.018 seconds

세포내의 물의 상태

  • 강사욱
    • Proceedings of the Botanical Society of Korea Conference
    • /
    • 1985.08b
    • /
    • pp.51-57
    • /
    • 1985
  • In order to evlauate feasibility of the gene tagging by the maize transposable element Ac in heterologous plant systems, we have investigated physical distances and directions of transposition of the element in Arabidopsis thaliana and tobacco cultured cell line BY-2. We prepared a T-DNA construct that carried a non-autonomous derivative of Ac with a site for cleavage by endonuclease I-Scel (designated dAc-I-RS element). Another cleavage site was also introduced into the T-DNA region outside dAc-I-RS. A number of transgenic Arabidopsis plants were generated, each of which had a single copy of the T-DNA at a different chromosomal location. To examine the pattern of transposition, three out of these transgenic plants were crossed with the Arabidopsis plant that carried the gene for Ac transposase and progeny in which dAc-I-RS had been transposed were isolated. After digestion of the genomic DNA of these progeny with I-SceI, sizes of segment of DNA were determined byd pulse-field gel electrophoresis. We also performed linkage analysis for the transposed elements and sites of mutations near the elements. Our results with three transgenic lines showed that 50% of all transposition events had occurred within 1, 700 kilo-base pairs (kb) on the same chromosome, with 35% within 200 kb, and that the elements transposed in both directions on the chromosome with roughly equal probability. The data thus indicate that the Ac-Ds system is most useful for tagging of genes that are present within 200 kb of the chromosomal site of Ac in Arabidopsis. In addition, determination of the precise localization of the transposed dAc-I-RS element should definitely assist in map-based cloning of genes around insertion sites. In the present paper, we report typical examples of such gene isolation studies.

  • PDF

Seismic Performance Evaluation of Multi-Story Piping Systems using Triple Friction Pendulum Bearing (지진격리장치를 적용한 복층구조파이핑 시스템의 내진성능평가)

  • Ryu, Yonghee;Ju, Buseog;Son, Hoyoung
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.4
    • /
    • pp.450-457
    • /
    • 2018
  • Purpose: The evaluation of seismic performance of critical structures has been emerging a key issue in Korea, since a magnitude 5.8 earthquake, the worst in Koran history, struck Gyeongju, southern area in Korea on september 12th, 2016. In particular, the catastrophic failure of nonstructural components such as sprinkler piping systems can cause significant economic loss or loss of life during and after an earthquake. The nonstructural components can be more fragile than structural components in seismic behavior. Method: This study presents the seismic performance evaluation of fire protection piping system, using coupled building-piping system installed with Triple Friction Pendulum Bearings (TPBs). Kobe (Japan), Kocaeli (Turkey), and GyeongJu (Korea) were selected to consider the uncertainty of ground motions in this study. Result: In the simulation results, it was observed that the reduction of maximum displacements of the piping system with the TPBs' system was significant: Kobe, Kocaeli, and Gyeongju cases were 49%, 14.4% and 21.5%, respectively. Conclusion: Therefore, using seismically isolated system in a building-piping system can be more effective to reduce the seismic risk than a normally installed building-piping systems without TPBs in strong earthquakes.