• Title/Summary/Keyword: band pressure

Search Result 509, Processing Time 0.024 seconds

Elastic-plastic Contact Stress Analysis of CRT Glass Bulb (CRT 글래스 벌브의 탄소성 접촉 응력 해석)

  • Kang, Dae Jin;Shin, Woon Seo;Song, Chang Seop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.2
    • /
    • pp.145-151
    • /
    • 1997
  • In this paper, we discuss the cathode ray tube(CRT) glass bulb stress and sagging recovery by the contact band pressure using finite element method. We analyzed the band pressure and stress using contact element method between band and bulb before and after banding process which was conducted to decrease the stress concentration using finite element method, and calculated sagging recovery. The analysis results were confirmed by experiments using strain gauge and sagging recovery test apparatus.

  • PDF

SAMPLING BASED UNCERTAINTY ANALYSIS OF 10 % HOT LEG BREAK LOCA IN LARGE SCALE TEST FACILITY

  • Sengupta, Samiran;Dubey, S.K.;Rao, R.S.;Gupta, S.K.;Raina, V.K
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.690-703
    • /
    • 2010
  • Sampling based uncertainty analysis was carried out to quantify uncertainty in predictions of best estimate code RELAP5/MOD3.2 for a thermal hydraulic test (10% hot leg break LOCA) performed in the Large Scale Test Facility (LSTF) as a part of an IAEA coordinated research project. The nodalisation of the test facility was qualified for both steady state and transient level by systematically applying the procedures led by uncertainty methodology based on accuracy extrapolation (UMAE); uncertainty analysis was carried out using the Latin hypercube sampling (LHS) method to evaluate uncertainty for ten input parameters. Sixteen output parameters were selected for uncertainty evaluation and uncertainty band between $5^{th}$ and $95^{th}$ percentile of the output parameters were evaluated. It was observed that the uncertainty band for the primary pressure during two phase blowdown is larger than that of the remaining period. Similarly, a larger uncertainty band is observed relating to accumulator injection flow during reflood phase. Importance analysis was also carried out and standard rank regression coefficients were computed to quantify the effect of each individual input parameter on output parameters. It was observed that the break discharge coefficient is the most important uncertain parameter relating to the prediction of all the primary side parameters and that the steam generator (SG) relief pressure setting is the most important parameter in predicting the SG secondary pressure.

Effects of Yohimbine and Atipamezole in Dogs Anesthetized with Xylazine-Ketamine Combination on EEG (Yohimbine과 Atipamezole이 Xylazine-Ketamine 병용 마취견의 뇌파에 미치는 영향)

  • 장환수;장광호;이만기;장인호
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.174-185
    • /
    • 2002
  • We investigated the effects of yohimbine and atipamezole in dogs anesthetized with xylazine-ketamine combination on electroencephalography (EEG) . Experiment groups were divided into three according to antagonists . Saline (1 ml) was used as an antagonist in group C, yohimbine (0.1 mg/kg) in group Y and atipamezole (50 ug/kg) in group A. Each group consisted of 5 dogs. Glycopyrrolate was injected 15 minutes prior to xylazine injection. Xylazine (1.1 mg/kg, IM) and ketamime (10 mg/kg, IV) were injected with the interval of 10 minutes. After 15 minutes, antagonists were administered intravenously. For EEG measurements, a recording electrode was positioned at Cz, which was applied to International 10-20 system. Heart rates, body temperature, respiratory rates, arterial blood pressure, $PaO_2$$PaCO_2$$PaCO_2$ at S4 in group Y was significantly decreased(p<0.05). Changes of electrolytes were not significant, except value of $Cl^-$ at S3 in group A. Mean head-up time (the time dogs showing head-up movement after antagonist injection, minutes) was $38.23^{\circ}$ae6.46 in group C, 2.54 $\pm$ 0.93 in group Y and 2.12$\pm$ 1.32 in group A. Mean sternal recumbent time (the time dogs showing sternal recumbency after antagonist injection, minutes) was 45.93$\pm$ 10.27 in group C, 11.91 $\pm$ 7.19 in group Y and 9.88$\pm$ 3.38 in group A. Mean walking time (minutes) was 53.49$\pm$ 9.21 in group C, 22.10$\pm$ 11.10 in group Y and 18.48$\pm$ 4.39 in group A. In group Y all dogs showed excitation and muscle rigidity in emergence. In group A, two dogs were also showed excitation and muscle rigidity, but were weaker than those of group Y.

Surgical Treatment of Double Chambered Right Ventricle: A Case Report (이강 우심실: 1례 보고)

  • 안광필
    • Journal of Chest Surgery
    • /
    • v.11 no.1
    • /
    • pp.65-68
    • /
    • 1978
  • The unusual congenital anomaly, double chambered right ventricle due to aberrant muscle band with intact ventricular septum in 10 years old female patient is presented. The pressure gradient is 70mmHg between inflow tract and outflow tract of right ventricle and the aberrant muscle band is 2X4.5cm arising below the infundibulum and traverses the right ventricular cavity, extending from its anterior wall to the crista supraventricularis forming broad triangular base in parietal anterior wall. By resecting out this muscle band clearly, the outflow tract obstruction is completely relieved.

  • PDF

GlSPD Analysis Using UHF Dual-Band Method (UHF 이중대역법을 이용한 GIS PD 분석)

  • Yi, Sang-Hwa;Choi, Jae-Gu;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.63-66
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD defecting system in which PD signals are defected into the dual UHF band. Thc UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High hand to Full band increases with gas pressure.

  • PDF

Investigation of the heavy-weight floor impact sound field in a testing building with bearing wall structure (벽식구조 표준시험동에서 중량충격음장에 관한 연구)

  • Yoo, Seung-Yup;Lee, Sin-Young;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.969-973
    • /
    • 2007
  • The heavy-weight floor impact sound field of the receiving room in a testing building with bearing wall structure was investigated using bang machine and impact ball. The sound field was investigated through the impact sound pressure level distribution by the field measurement and computational analysis. Predicted sound field using the computational analysis agree with measurement result in the low frequency band. Result shows that standard deviations of the single number rating value are about 2dB in each impact source. Particularly, impact sound pressure level at 120cm height in 63Hz octave band was 5dB lower than spatial averaging value. It was found that receiving positions in the ministry of construction and transportation notice should be reconsidered.

  • PDF

Optical Characteristics of Oxygen-doped ZnTe Thin Films Deposited by Magnetron Sputtering Method

  • Kim, Seon-Pil;Pak, Sang-Woo;Kim, Eun-Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.253-253
    • /
    • 2011
  • ZnTe semiconductor is very attractive a material for optoelectronic devices in the visible green spectral region because of it has direct bandgap of 2.26 eV. The prototypes of ZnTe light emitting diodes (LEDs) have been reported [1], showing that their green emission peak closely matches the most sensitive region of the human eye. The optoelectronic properties of ZnTe:O film allow to expect a large optical gain in the intermediate emission band, which emission band lies about 0.4-0.6 eV below the conduction band of ZnTe [2]. So, the ZnTe system is useful for the production of high-efficiency multi-junction solar cells [2,3]. In this work, the ZnTe:O thin films were deposited on Al2O3 substrates by using the radio frequency magnetron sputtering system. Three sets of samples were prepared using argon and oxygen as the sputtering gas. The deposition chamber was pre-pumped down to a base pressure of 10-7 Torr before introducing gas. The deposition pressure was fixed at 10-3 Torr throughout this work. During the ZnTe deposition, the substrate temperature was 300 oC. The optical properties were also investigated by using the ultraviolte-visible (UV-Vis) spectrophotometer.

  • PDF

Filament Band Winding Simulation for Fiber Reinforced Cylindrical Pressure Vessels (FRP의 원통형 압력 용기제작을 위한 필라멘트 밴드의 감김 시뮬레이션)

  • Yun, Jaedeuk;Fu, Jianhui;Jung, Yoongho
    • Korean Journal of Computational Design and Engineering
    • /
    • v.19 no.1
    • /
    • pp.19-28
    • /
    • 2014
  • The filament winding method is widely used to manufacture products of fiber reinforced plastics (FRP), such as high pressure vessels, launch tubes and pipes. For reducing winding time, the method of winding by filament band which consists of several filament fibers is used. NC winding machine is used for precise winding and NC path is needed. Before filament winding, users should verify that winding path which presented by a line is appropriate by filament winding simulation. Also, the used length of each filament is different. So, if the peak filament exhausted, it causes to stop manufacturing. In this research, we developed software which visualizes 3D graphic of filament band winding path and simulates winding process on real time. And we proposed algorithm about calculation of each filament usage. We use geodesic equation for generating filament band surface and calculating the usage length of each filament.

Plastic Deformation Analysis of Rotating Band by Three-Dimensional Finite Element Method Using Recurrent Boundary Condition (반복경계조건을 도입한 3차원 유한요소법에 의한 회전탄대의 소성변형 공정해석)

  • 양동열;이영규;박용복;조용찬;한만준
    • Transactions of Materials Processing
    • /
    • v.5 no.2
    • /
    • pp.122-129
    • /
    • 1996
  • The main objective of the study is to offer some basic information in relation to optimal shape and dimensions of the rotating band through the development of three-dimensional finite element method for metal forming analysis of the rotating band whose primary function is to impart spin to the projectile. The three-dimensional metal forming analysis of the rotating band has perfor-med by using recurrent boundary conditions. Such design factors as the outside diameter the total length and the profile of the rotating band must be considered carefully in order to design an optimal rotating band. Above design factors can be determined from such available analysis results as the deformed shape and the deformation load. of the rotating band and the normal pressure of the rotating band on a projectile shell. The remeshings are needed to carry out plastic deformation analysis with severe deformation through which the complete process analysis gets possible. The results can be utilized effectively in determining the optimal shape and size of the rotating band.

  • PDF

Effects of foot pressure using the elastic band with rings during sit-to-stand in persons with stroke

  • Hwang, Young-In;Kim, Ki-Song
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.4
    • /
    • pp.159-163
    • /
    • 2017
  • Objective: Persons with stroke have a tendency to exhibit asymmetric weight-bearing during sit-to-stand because due to the attempt to support themselves with the non-paretic foot. However, there are few devices that can assist with sit-to-stand (STS) performance. This study was designed to investigate the use of the elastic band with rings (EBR) in improving weight-bearing effectively in persons with stroke during STS training. Design: Cross-sectional study. Methods: Thirteen stroke survivors participated in the study. An EBR was applied onto the patient during STS activity. The foot pressure was measured before and after wearing the EBR, with a 5-minute rest period between measurements. Subjects were asked to perform each test twice with and without the EBR. Bilateral feet pressures were measured with standing posture being divided into the forward and backward aspects. The foot contact pressure during STS activity was measured with the CONFORMat System. Results: With EBR, the forward pressure of the affected foot significantly increased while the less-affected forward foot pressure significantly decreased (p=0.015 and p=0.023, respectively). The backward foot pressure did not differ significantly in the two limbs, and there was no difference with and without the EBR in terms of the total pressure of the affected foot. There was a significant difference with and without the EBR in the total pressure of the less-affected foot (p<0.05). Conclusions: STS training with the EBR has been shown to improve weight-bearing of both feet while decreasing the total pressure of the less-affected foot in stroke survivors. Therefore, we suggest that the EBR is a useful tool for STS training for persons with stroke in the clinic.