• Title/Summary/Keyword: balancing control

Search Result 636, Processing Time 0.024 seconds

Cost-Effective Converters for Micro Wind Turbine Systems using PMSG

  • Park, Hong-Geuk;Lee, Dong-Choon;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.156-162
    • /
    • 2008
  • This paper proposes a low-cost power converter for micro wind turbine systems using permanent magnet synchronous generators (PMSG). The proposed converter consists of a two-leg three-phase PWM inverter for the generator control and a single-phase half-bridge PWM converter which is connected to the utility grid. For the two separate DC-link voltages, a balancing control is added and the adverse effect of the DC-link voltage ripples on the inverter output voltage is compensated. The control performance of the proposed converter topology for the micro wind turbine system is shown by the simulation results using PSIM software.

RCGA-Based State Feedback Control for Seesaw Systems (시소 시스템을 위한 RCGA 기반의 상태피드백 제어)

  • Oh, Sea-June;So, Myung-Ok;Jung, Byung-Gun;Ryu, Ki-Tak;Lee, Yun-Hyung;Lee, Sang-Tae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.974-980
    • /
    • 2008
  • Generally. most of the physical systems affected by disturbance or incomplete knowledge are complex and highly nonlinear. To control under these circumstances. many researches are ongoing in modern control theory recently. But the researches need apparatuses. which can verify the controller for being not damaged the real plant. In this paper. therefore. a seesaw system is considered control system to analyze and apply the control theory. A seesaw system consists of a moving cart on the rail and seesaw frame made to demonstrate the effectiveness of the control theory. The system has balancing and positioning problems. and the driving force is applied on the DC motor of cart. but not on the pivot. The purpose of control is to maintain an equilibrium of seesaw frame in spite of an allowable disturbance. Computer simulations are given to illustrate the control performance of the proposed scheme.

Slip Ratio Reduction and Moving Balance Control of a Ball-bot using Mecanum Wheel (메카넘 휠을 이용한 볼-봇의 슬립률 감소와 균형 및 주행제어)

  • Park, Young Sik;Kim, Su Jeong;Byun, Soo Kyung;Lee, Jang Myung
    • The Journal of Korea Robotics Society
    • /
    • v.10 no.4
    • /
    • pp.186-192
    • /
    • 2015
  • This paper proposes a robust balance and driving control for omni-directional ball robot(generally called ball-bot) with two axis mecanum wheel. Slip between ball and mecanum wheel actuator inevitably occurs along diagonal axis due to its instantaneous strong torque. In order to reduce and saturate slip, exact distance calculation scheme especially for rotational movement is essential. So this research solved Euler-Lagrange dynamics for proposed two axis ball robot based on practical mechanical modeling. Robust balance control was carried out by PID controller according to the pitch and roll angles of ball robot by using sensor fusion between AHRS and wheel encoder. Proposed PID controller enhances stability by reducing steady state error and settling time. Proposed slip control algorithm for omni-directional ball robot has been demonstrated by experiments for balance control and arbitrary driving control.

A Scheduling Algorithm using The Priority of Broker for Improving The Performance of Semantic Web-based Visual Media Retrieval Framework (분산시각 미디어 검색 프레임워크의 성능향상을 위한 브로커 서버 우선순위를 이용한 라운드 로빈 스케줄링 기법)

  • Shim, Jun-Yong;Won, Jae-Hoon;Kim, Se-Chang;Kim, Jung-Sun
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.1
    • /
    • pp.22-32
    • /
    • 2008
  • To overcome the weakness of the image retrieval system using the existing Ontology and the distributed image based on the database having a simple structure, HERMES was suggested to ensure the self-control of various image suppliers and support the image retrieval based on semantic, the mentioned framework could not solve the problems which are not considered the deterioration in the capacity and scalability when many users connect to broker server simultaneously. In this paper the tables are written which in the case numerous users connect at the same time to the supply analogous level of services without the deterioration in the capacity installs Broker servers and then measures the performance time of each inner Broker Component through Monitoring System and saved and decides the ranking in saved data. As many Query performances are dispersed into several Servers User inputted from the users Interface with reference to Broker Ranking Table, Load Balancing system improving reliability in capacity is proposed. Through the experiment, the scheduling technique has proved that this schedule is faster than existing techniques.

Improvement of the Detection of LOB through Reconstruction of an Internal Model (내부 모델의 재구성에 의한 균형상실 검출성능 개선)

  • Kim, Kwang-Hoon;Park, Jung-Hong;Son, Kwon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.9
    • /
    • pp.827-832
    • /
    • 2010
  • Many researchers have tried to detect the falling and to reduce the injury associated with falling. Normally the method of detection of a loss of balance is more efficient than that of a compensatory motion in order to predict the falling. The detection algorithm of the loss of balance was composed of three main parts: parts of processing of measured data, construction of an internal model and detection of the loss of balance. The internal model represented a simple dynamic motion balancing with two rear legs of a four-legged chair and was a simplified model of a central nervous system of a person. The internal model was defined by the experimental data obtained within a fixed time interval, and was applied to the detecting algorithm to the end of the experiment without being changed. The balancing motion controlled by the human brain was improved in process of time because of the experience accruing to the brain from controlling sensory organs. In this study a reconstruction method of the internal model was used in order to improve the success rate and the detecting time of the algorithm and was changed with time the same as the brain did. When using the reconstruction method, the success rate and the detecting time were 95 % and 0.729 sec, respectively and those results were improved by about 7.6 % and 0.25 sec in comparison to the results of the paper of Ahmed and Ashton-Miller. The results showed that the proposed reconstruction method of the internal model was efficient to improve the detecting performance of the algorithm.

Service Restoration In Distribution Networks Using Cyclic Best-First Search (순환적 최적우선탐색을 이용한 배전계통의 정전복구)

  • Choi, Sang-Yule
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.162-168
    • /
    • 2004
  • Service restoration is an emergency control in distribution control centers to restore out-of-service area as soon as possible when a fault occurs in distribution networks. Therefore, it requires fast computation time and high quality solutions for load balancing. In this paper, a load balance index and heuristic guided best-first search are proposed for these problem. The proposed algorithm consists of two parts. One is to set up a decision tree to represent the various switching operations available. Another is to identify the most effective the set of switches using proposed search technique and a feeder load balance index. Test results on the KEPCO's 108 bus distribution system show that the performance is efficient and robust.

A Study on the Chattering under Cryogenic Flow Test of a Oxidizer Shutoff Valve (산화제 개폐밸브의 극저온 유동시험에서 채터링의 고찰)

  • Lee, JoongYoup;Han, SangYeop;Lee, SooYong
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.108-117
    • /
    • 2013
  • The oxidizer shutoff valve of a gas generator controls the mass flow rate of the propellant of a rocket engine using pilot pressure and spring the force of the valve. The developing oxidizer shutoff valve can be shut off if the pilot pressure is removed from the actuator. Therefore, force balancing is necessary to analyze the characteristics of the forces with respect to the opening and closing of the valve in order to evaluate its performance. In light of this, the valve has been designed to adjust the control pressure required to open the poppet and to determine the working fluid pressure at which the valve starts to close. Under cryogenic flow test as a tests level of C.R.T(Control Random Test), the chattering phenomena occurred due to much leakage of a metal seat section. The pressure for chattering of the oxidizer valve is predicted at about 11 bar using force balancing analysis.

A Study on Apply of Smart Sensors for Wheelchair Balancing Control (휠체어 균형 조정을 위한 스마트 센서의 적용에 관한 연구)

  • Ma, Linh Van;Cho, Young-bin;Kim, Jinsul
    • Journal of Digital Contents Society
    • /
    • v.19 no.8
    • /
    • pp.1585-1592
    • /
    • 2018
  • Due to un-balancing weight allocation on the wheelchair the existing wheelchair system are faced with the risk of flipping or falling when a wheelchair goes up to a hill. In to order to be safer during riding the wheelchair, in this paper, we proposed a real-time new solution using the integrated Gyro Sensor and Tilt Sensor for controlling the balance. Because the typical property of wheelchair is for the special user who meets the difficulty in moving on foot the maintain the balance of wheel-chair systems have become important and helpful. In our method, we calculate the seat angle using information from Tilt Sensor. However, due to the law of inertia when a wheelchair is moving there is a deviation in the output value of Tilt Sensor. Therefore, we have to optimize the value of the angle by utilizing the acceleration that is the output of the Gyro Sensor. We took the advantages by using the combination of Gyro and Tilt sensors. Moreover, we also solved the consumption issue of the whole system. Through various experimentations with usage of ZigBee sensor module, the power consumption for the balancing system is reduced significantly.

A Seamless Transfer Method of Bidirectional DC-DC Converter for ESS in DC Micro-grids (DC 마이크로그리드에서 에너지 저장장치를 위한 양방향 DC-DC컨버터의 무순단 절체 제어기법)

  • Kwon, Min-Ho;Park, Jung-Sung;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.194-200
    • /
    • 2014
  • In DC micro-grid system energy storage systems (ESS) are responsible for storing energy and balancing power. Also, control target of the bidirectional DC-DC converter(BDC) for ESS should be changed depending on the operating mode. During the grid connected mode, the BDC controls the battery current or voltage. When a grid fault occurs, the BDC should change the control target to regulate the DC-bus. The BDC with conventional control method may experience large transient state during the mode change. This paper proposes a control method of BDC for ESS. The proposed control method is able to provide autonomous and seamless mode transfer by a variable current limiter. To validate the proposed concept, simulation results using PSIM and experimental results from a 2kW prototype are provided.

Finite State Model-based Predictive Current Control with Two-step Horizon for Four-leg NPC Converters

  • Yaramasu, Venkata;Rivera, Marco;Narimani, Mehdi;Wu, Bin;Rodriguez, Jose
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1178-1188
    • /
    • 2014
  • This study proposes a finite-state model predictive controller to regulate the load current and balance the DC-link capacitor voltages of a four-leg neutral-point-clamped converter. The discrete-time model of the converter, DC-link, inductive filter, and load is used to predict the future behavior of the load currents and the DC-link capacitor voltages for all possible switching states. The switching state that minimizes the cost function is selected and directly applied to the converter. The cost function is defined to minimize the error between the predicted load currents and their references, as well as to balance the DC-link capacitor voltages. Moreover, the current regulation performance is improved by using a two-step prediction horizon. The feasibility of the proposed predictive control scheme for different references and loads is verified through real-time implementation on the basis of dSPACEDS1103.