• Title/Summary/Keyword: balance measurement system

Search Result 180, Processing Time 0.034 seconds

Construction of Ultrasonic Power Measurement System and Its Performance Evaluation (초음파 파워 측정 시스템 구성 및 성능평가)

  • Jho Moon Jae;Kim Yong Tae;Yun Yong Hyeon;Jung Suug Soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.8
    • /
    • pp.431-440
    • /
    • 2005
  • The precise measurement of ultrasonic power is important to the qualify assurance and the safety of medical ultrasonic equipments In the Present work, a brier theory was introduced to determine the ultrasonic Power from the time valving balance-indication due to the radiation force acting on an absorbing target and/or other causes such as buoyancy during the repetition of on/off behavior of ultrasonic irradiation. The developed automated system measuring the ultrasonic power was described in detail with the precise mechanical alignment tool , the electric signal generation network, the control and measurement network and the appropriate procedure. The ultrasonic power measured by the developed system was compared to the reference data calibrated by the other national metrology institute at 1 MHz, 5 MHz, 10 MHz, and 15 MHz over the range 10 mW to 10 W. Their relative differences are within $5\%$.

Development for a method of measurement in equilibrium sense (평형감각 측정기술의 개발)

  • 이문영;정영자;김규겸;이성호;박병림
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.03a
    • /
    • pp.3-6
    • /
    • 1999
  • The study was performed to evaluate the sense of equilibrium by means of rotary chair system in middle school girls with dance learning. Control of equilibrium, which is the most important function in dancing, is maintained by vestibular, visual, and proprioceptive inputs. Experimental groups were divided into trained group with dance (experimental group, 13~14 ys, n=15) and untrained group (control group, 13~14 ys, n=15). experimental group was trained by programmed dancing for 12 weeks, 45 min/day and 5 day/week. Gain of eye movement was measured for vestibulocular reflex (VOR), visual vestibular stimulation (VVOR), optokinetic stimulation(OKN), and visual fixation (VFX). The gain of eye movement at higher than 0.08 hz was significant decrease in experimental group, and VVOR showed the similar fashion to VOR. The gain in OKN and VFX was not significant difference between experimental and control groups. These results suggest that programmed training of dancing improves control of balance by adaptation of the vestibular function, and rotary chair system would be useful to evaluate the sense of equilibrium ability.

  • PDF

The Effects of a Functional Movement Screen on Pain and Performance Ability in Professional Fencing Players (펜싱선수에서 통증과 수행 능력이 기능적 동작 검사에 미치는 영향)

  • Kim, Seong-Yeol;Lee, Je-Hoon;An, Seung-Heon
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.21-28
    • /
    • 2011
  • Purpose: The aim of this study was to investigate correlations between the Functional Movement Screen (FMS), pain, and performance ability in professional fencing players. Methods: Fifty-six athletes participated in this study. The pain group included those who had a score on a pain-related Visual Analogue Scale (VAS) of ${\geq}$20 and an Oswestry Disability Index (ODI) score ${\geq}$10). In the non-pain group, these scores were: VAS(<20), ODI(<10). The VAS and ODI were used to measure pain throughout the study. Performance ability included motor function of the lower extremities (as assessed by a Modified Functional Index Questionnaire, MFIQ), dynamic balance (Balance system, BS and Posture med, PM), flexor and extensor muscle strength of the lumbar region was recorded as maximal isometric strength. Results: Among athletes who had pain, 5 of 15(33.33%) showed impaired functional movement. Conversely, only 2 of 41(4.88%) of those who had no pain showed such impairment (FMS ${\leq}$14score). The athletes who had pain and who had an FMS score above 14 (10/56; 17.86%) showed a significantly higher score for extensor muscle strength of the lumbar compared with those with pain and an FMS score below 14 (5/56; 8.93%) were significant correlations between the FMS and pain (r=-0.40 to -0.42, p<0.01), the MFIQ (r=-0.33, p<0.05), dynamic balance (r=-0.27 to -0.40, p<0.05-0.01), muscle strength of the lumbar (r=0.27 to 0.29, p<0.05). Stepwise multiple regression analysis showed that the dynamic balance score (${\beta}{\beta}$=-0.41) had slightly more power in predicting FMS score than pain, motor function of lower extremity, or muscle strength. Conclusion: The FMS was significantly associated with values of pain, motor function of the lower extremities, dynamic balance, and muscle strength of the lumbar. However the FMS appears to lack relevance and reasonable evidence to suggest that it is an acceptable measurement tool for functional movement analysis.

Balancing air flow at terminal in CAV duct system with DPM method (정풍량방식 덕트에서 이중압력측정방법을 이용한 취출구 풍량조정)

  • 이대우;박명식;박영우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.66-78
    • /
    • 1998
  • Adequate ventilation with the proper amount of air to the right place is important factor to achieve a good Indoor air climate. Thus it is of prime importance that the ventilation system is working properly. This requires reliable pressure loss calculation to balance the air flow through duct systems. So a computer program for balancing CAV duct system is developed In this study. The results of CAV duct system is compared with the "Balans" code developed by Larsen from Norway. To obtain the pressure drop characteristics of damper at duct terminal, some experiments are performed using DPM(Dual Pressure Measurement) system. To adjust the resistance of damper, present study suggests that some special diffusers should be designed and damper producers should give the data of air flow vs. pressure drop to the customs when they manufacture the damper. One of the results concludes that the working time can be reduced from several minutes to several seconds per damper in the present experimental site, if the DPM system and the air volume adjusting process are used.

  • PDF

A Study of Sensing Locations for Self-fitness Clothing base on EMG Measurement (셀프 피트니스 의류 개발을 위한 근전도 센싱 위치 연구)

  • Cho, Hakyung;Cho, Sangwoo
    • Fashion & Textile Research Journal
    • /
    • v.18 no.6
    • /
    • pp.755-765
    • /
    • 2016
  • Recently, interest in monitoring health and sports is growing because of the emphasis on wellness, which is accelerating the development and commercialization of smart clothing for biosignal monitoring. In addition to exerciseeffect monitoring clothing that tracks heart rate and respiration, recently developed clothing makes it possible to monitor muscle balance using electromyogram (EMG). The electrode for EMG have to attached to an accurate location in order to obtain high-quality signals in surface EMG measurement. Therefore, this study develops monitoring clothing suitable for different types of human bodies and aims to extract suitable range of EMG according to movements in order to develop self-fitness monitoring clothing based on EMG measurement. This study identified and attached electrodes on six upper muscles and two lower muscles of ten males in their 20s. After selecting six main motions that create a load on muscles, the 8-ch wireless EMG system was used to measure amplitude value, noise, SNR and SNR (dB) in each part and statistical analysis was conducted using SPSS 20.0. As a result, the suitable range for EMG measurement to apply to clothing was identified as four parts in musculus pectoralis major; three parts in muscle rectus abdominis, two parts each in shoulder muscles, backbone erector, biceps brachii, triceps brachii, and musculus biceps femoris; and four part in quadriceps muscle of thigh. This was depicted diagrammatically on clothing, and the EMG-monitoring sensing locations were presented for development of self-fitness monitoring.

Measurement of Soil CO2 Efflux Using a Closed Dynamic Chamber System (폐회로 역학 챔버 시스템을 이용한 토양 이산화탄소 플럭스 관측)

  • Chae, Nam-yi;Kim, Joon;Kim, Dong-gill;Lee, Do-won;Kim, Rae-Hyun;Ban, Ji-yeon;Son, Yo-whan
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.2
    • /
    • pp.94-100
    • /
    • 2003
  • Soil $CO_2$ emission is one of the primary components in carbon balance of terrestrial ecosystems. To accurately assess their net ecosystem exchange of $CO_2$ and net primary production, measurement of soil $CO_2$ efflux is required along with that of canopy $CO_2$ flux. In this paper, soil $CO_2$ flux measurement technique using closed dynamic chamber systems is briefly reviewed. Preliminary results on soil $CO_2$ exchange and inter-comparison of different measurement systems currently used in Korean regional network of tower flux measurement sites (KoFlux) are also reported.

Effects of Vibratory Stimulus on Postural Balance Control during Standing on a Stable and an Unstable Support (안정판과 불안정판에서 자세 균형 조절에 대한 진동자극의 영향)

  • Yu, Mi;Eun, Hey-In;Kim, Dong-Wook;Kwon, Tae-Kyu;Kim, Nam-Gyun
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.5
    • /
    • pp.647-656
    • /
    • 2007
  • The purpose of this study was to analyze the effects of vibratory stimulus as somatosensory inputs on the postural control in human standing. To study these effects, the center of pressure(COP) was observed while subjects were standing on a stable and an unstable support with co-stimulated mechanical vibrations to flexor ankle muscles(tibialis anterior tendon, achilles tendon) and two plantar zones on both foot. The COP sway measurement was repeated twice in four conditions: (1) with visual cue and vibration, (2) without visual cue and vibration, (3) with visual cue and without vibration, (4) without visual cue and with vibration. The calculated parameters were the COP sway area and the distance, the median frequency and the spectral energy of COP sway in three intervals $0.1{\sim}0.3,\;0.3{\sim}1,\;1{\sim}3Hz$. The results showed that vibratory stimulus affect postural stability. The reduction rate of the COP sway with vibratory stimulus were higher on the unstable support because the effect of postural stability increases when afferent nervous flow is more activated by vibration on unstable support. If unclear visual or vibratory information is received, one type of information is compared with the other type of sensory information. Then the input balance between visual and vibratory information is corrected to maintain postural stability. These findings are important for the rehabilitation system of postural balance control and the use of vibratory information.

The methodology on the application of EEG as a diagonostic measures in Korean Traditional Medicine (뇌파의 한의학적 진단 지표로의 활용 방안에 대한 연구초안)

  • Seo, Young-Hyo;Kim, Gyeong-Cheol;Kim, Bo-Kyung
    • Journal of Oriental Neuropsychiatry
    • /
    • v.18 no.1
    • /
    • pp.37-61
    • /
    • 2007
  • Objective : By examining EEG status in Korean Traditional Medicine (KTM) from the viewpoint of 'form-qi theory(形氣論)', We wish to prepare for the fundamentals of applicability of KTM diagnoses to EEG. In addition, through reinterpretation of existing Western Medicine reports from the viewpoint of KTM, We tried to find out interrelationship between them. Method : In this paper, a methodology applicable to KTM diagnoses of EEG is presented from the EEG features in waveform characteristics, personalized diversity, and cognitive activity reflection. Results : Frequency bands are assigned to corresponding one of the eight trigrams in terms of yin/yang balance, which is analogous with EEG spectrum analysis mostly used in EEG quantification. The amplitude ratio of each EEG for each frequency band gives meaningful index numbers which can be used in EEG data interpretation, and every index number is named after the sixty four hexagrams. These approaches are adopted through both '4-band classification system and '6-band classification system', and applied to pre-existing reported EEG data obtained from normal adults. These analyses show that changes and distribution pattern in the index numbers are observed as a whole on both left-right line and front-back line connecting EEG measurement cephalic electrodes. And differences in distribution pattern of three index numbers deduced from '6-band classification system' are discussed according to constitution. Conclusion : The index numbers introduced here, which are the spectral power ratio for each EEG, are based on KTM yin/yang balance. These index numbers vary according to cephalic location, so its application in terms of traditional meridian theory is strongly expected. The index number distribution also shows different patterns according to constitution.

  • PDF

A Technique for Fast Sampling Measurement of Digital Frequency Relay (디지털주파수계전기의 고속 샘플링추정기법)

  • Nam, S.B.;Lee, H.G.;Ma, S.B.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.185-190
    • /
    • 2006
  • Frequency and phasor are the most important quantities in power system operation because they can reflect the whole power system situation. Frequency reflects the dynamic energy balance between load and generating power, while operators use phasor to constitute the state of system and, moreover, phasor based line relays are currently used in most power systems. So frequency and phasor are regarded as indices for the operating power systems in practice. The proposed technique is suitable for estimation near-nominal, nomina), and off-nominal frequencies. It is useful in designing microprocessor-based relays and meters that need to measure power system frequency. Performance test results, using signals from EMTP source and Excel program, indicate that the proposed technique can provide accurate estimates within 16ms. Maximum estimation errors observed during testing are of the order of 0.006Hz for nominal, near-nominal, and off-nominal frequencies. The proposed technique provides accurate estimates in presence of noise and harmonics and in case ground fault. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

Experimental investigation of two-phase natural circulation loop as passive containment cooling system

  • Lim, Sun Taek;Kim, Koung Moon;Kim, Haeseong;Jerng, Dong-Wook;Ahn, Ho Seon
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.3918-3929
    • /
    • 2021
  • In this study, we experimentally investigate of a two-phase natural circulation loop that functions as a passive containment cooling system (PCCS). The experimental apparatus comprises two loops: a hot loop, for simulating containment under severe accidents, and a natural circulation loop, for simulating the PCCS. The experiment is conducted by controlling the pressure and inlet temperature of the hot loop in the range of 0.59-0.69 MPa (abs) and 119.6-158.8 ℃, respectively. The heat balance of the hot loop is established and compared with a natural circulation loop to assess the thermal reliability of the experimental apparatus, and an additional system is installed to measure the vapor mass flow rate. Furthermore, the thermal-hydraulic characteristics are considered in terms of a temperature, mass flow rate, heat transfer coefficient (HTC), etc. The flow rate of the natural circulation loop is induced primarily by flashing, and a distortion is observed in the local HTC because of the fully develop as well as subcooled boiling. As a result, we present the amount of heat capacity that the PCCS can passively remove according to the experimental conditions and compared the heat transfer performance using Chen's and Dittus-Boelter correlation.