• Title/Summary/Keyword: baffle angle

Search Result 33, Processing Time 0.02 seconds

A Study on the Optimization of Sedimentation Efficiency through Controlling Stirring Speed and Baffle Angle (교반속도 및 Baffle 각도 조절에 따른 침전지 효율 최적화 연구)

  • Kwak, Sung-Keun;Kim, Choong-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.4
    • /
    • pp.69-75
    • /
    • 2020
  • This study was conducted to improve the solid-liquid separation efficiency of clarifiers. To do so, the study did a bio-flocculation experiment simply by controlling the stirring speed (rpm) and baffle angle of a clarifier on a lab scale, but without using a coagulant. For the purpose of the experiment, the feed wall of a clarifier was so improved that a baffle could be installed on the clarifier. Then, it was ensured to change its stirring speed (to 0.0rpm, 0.6rpm, and 1.2rpm), with the angle fixed at 10°. As a result, it was found that concentration efficiency increased by 2.0%, and effluent removal efficiency (SS concentration) by 7.8%, at a stirring speed of 0.6ppm. This indicates the bio-coagulation efficiency of sludge increased with changing stirring speeds. Then, the baffle angle of the sedimentation unit was changed to analyze how the changed baffle angle would affect the sedimentation of sludge. As a result, it was found that the compression of sludge interface was very effective at a baffle angle of 20°. It is hoped that these experimental findings will be useful in improving the sedimentation efficiency of circular clarifiers.

Thermo-hydraulic Effect of Tubular Heat Exchanger Fitted with Perforated Baffle Plate with Rectangular Shutter-type Deflector

  • Md Atiqur Rahman
    • Korean Chemical Engineering Research
    • /
    • v.62 no.2
    • /
    • pp.191-199
    • /
    • 2024
  • A study was conducted on a tubular heat exchanger to improve its heat transfer rate by using a novel baffle plate design with discontinuous swirling patterns. The design consisted of perforated baffle plates with rectangular air deflectors positioned at varying angles. The tubes in the heat exchanger were arranged in a consistent alignment with the airflow direction and exposed to a uniform heat flux on their surfaces. Each baffle plate included sixteen deflectors inclined at the same angle and arranged in a clockwise pattern. This arrangement induced a swirling motion of the air inside a circular duct where the heated tubes were located, leading to increased turbulence and improved heat transfer on the tube surfaces. The spacing between the baffle plates was adjusted at different pitch ratios, and the Reynolds number was controlled within a range of 16,000 to 29,000. The effects of pitch ratios and inclination angles on the heat exchanger's performance were analyzed. The results indicated that using a baffle plate with rectangular deflectors inclined at 30° and a pitch ratio of 1.2 resulted in an average increase of 1.29 in the thermal enhancement factor.

Study on the Performance Improvement according to Arrangement Angle of Baffle and Location of Air Duct in the Cold Air Dryer (냉풍 건조 시스템의 배플 배열각도 및 공기공급관 위치 변화에 따른 성능 향상에 관한 연구)

  • Yun, Chung-Kug;Yu, Ki-Tae;Park, Chul;Song, Hee-Geun;Bae, Kang-Youl;Chung, Han-Shik;Jeong, Hyo-Min
    • Journal of Power System Engineering
    • /
    • v.21 no.4
    • /
    • pp.62-69
    • /
    • 2017
  • Because the moist foods like anchovy were appeared lower quality by hot air that occurred the lipid oxidation, the drying system by using the cold air has been used widely. This study has been carried out on the performance improvement according to arrangement angle of baffle and location of air duct in the cold air dryer. The main parameters in this study are the arrangement angles which are without, $0^{\circ}$, $10^{\circ}$, $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$, and the locations of air duct are without, front, center and back. For this study we have conducted the numerical analysis method using fluent in order to obtain the optimal condition of the drying performance. As the arrangement angle of baffle is increased, the relative humidity is proportionally decreased, the value at $40^{\circ}$ is 42.2% that indicate the reduction of about 4% than without it. After the air duct was installed, the decreased relative humidity is showed within 1%, therefore, the effect of air duct for improving the dry capacity is more large than the arrangement angle of baffle. Finally, we have obtained the optimal conditions that the arrangement angle is $40^{\circ}$ with the air duct for a cold air dryer.

Heat Transfer and Friction Factors in the Channel with an Inclined Square Diamond Type Perforated Baffle (정 다이아몬드 형 구멍이 있는 배플을 가진 채널에서의 열전달과 마찰계수)

  • Oh, S.K.;Putra, A.B.K.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.12 no.3
    • /
    • pp.26-31
    • /
    • 2008
  • This experimental study investigates the local heat transfer enhancement characteristics and the associated frictional head loss in the rectangular channel with a single inclined baffle. Four different types of the baffle are used. The inclined baffles have the width of 19.8 cm, the square diamond of $2.55cm{\times}2.55cm$, and the inclination angle of 5o, and number of holes of up to 9. Reynolds number is varied between 23,000 and 57,000. Results show that the heat transfer and friction factor depend significantly on the number of baffle holes and Reynolds number. The friction factor decreases with increasing Reynolds number and the number of holes on the baffle. It is found that the heat transfer performance of baffle type II(3 hole baffle) has the best values.

  • PDF

A BAFFLE DESIGN FOR AN AIRGLOW PHOTOMETER ON BOARD THE KOREA SOUNDING ROCKET-III

  • LEE YOUNG SUN;KIM YONG HA;YI YU;KIM JHOON
    • Journal of The Korean Astronomical Society
    • /
    • v.33 no.3
    • /
    • pp.165-172
    • /
    • 2000
  • A baffle system for an airglow photometer, which will be on board the Korea Sounding Rocket-III(KSR-III), has been designed to suppress strong solar scattered lights from the atmosphere below the earth limb. Basic principles for designing a baffle system, such as determination of baffle dimensions, arrangement of vanes inside a baffle tube, and coating of surfaces, have been reviewed from the literature. By considering the constraints of the payload size of the KSR-III and the incident angle of solar light scattered from the earth limb, we first determined dimensions of a two-stage baffle tube for the airglow photometer. We then calculated positions and heights of vanes to prohibit diffusely reflected lights inside the baffle tube from entering into the photometer. In order to evaluate performance of the designed baffle system, we have developed a ray tracing program using a Monte Carlo method. The program computed attenuation factors of the baffle system on the order of $10^{-6}$ for angles larger than $10^{\circ}$, which satisfies the requirements of the KSR-III airglow experiment. We have also measured the attenuation factors for an engineering model of the baffle system with a simple collimating beam apparatus, and confirmed the attenuation factors up to about $10^{-4}$. Limitation of the apparatus does not allow to make more accurate measurements of the attenuation factors.

  • PDF

Heat Transfer and Friction Behaviour in a Channel with an Inclined Perforated Baffle

  • Krishna Putra, Ary Bachtiar;Ahn, Soo-Whan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.2
    • /
    • pp.70-76
    • /
    • 2008
  • The effects of the inclined perforated baffles on the distributions of the local heat transfer coefficients and friction factors for air flows in a rectangular channel were determined for Reynolds numbers from 23,000 to 57,000. Four different types of the baffle are used. The inclined baffles have the width of 19.8cm, the square diamond type hole having one side length of 2.55cm, and the inclination angle of $5^{\circ}$, whereas the corresponding channel width-to-height ratio was 4.95. Results show that the heat transfer and friction factor depend significantly on the number of baffle holes and Reynolds number. The friction factor decreases with increasing Reynolds number and the number of holes on the baffle, and the heat transfer performance of baffle type II (3 hole baffle) has the best value.

Numerical Analysis of the Effect of a Three-Dimensional Baffle Structure with Variable Cross-Section on the Parallel Flow Field Performance of PEMFC

  • Xuejian Pei;Fayi Yan;Jian Yao;He Lu
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.333-348
    • /
    • 2023
  • In this study, a 3D model of the proton exchange membrane fuel cell is established, and a new 3D baffle structure is designed, which is combined with the parallel flow field and then optimized by numerical simulation methods. The number of baffles and the cross-sectional trapezoidal base angle are taken as the main variables, and their impacts on the performance indexes of the cathode side are analyzed. The results show that the 3D baffle can facilitate the convection and diffusion mass transfer of reactants, improve the uniformity of oxygen distribution, enhance the drainage capacity, and make the cell performance superior; however, too small angle will lead to excessive local convective mass flux, resulting in the decrease of the overall uniformity of oxygen distribution and lowering the cell performance. Among them, the optimal number of baffles and angle are 9 and 58°, respectively, which improves the net output power density by 10.8% than conventional flow field.

Effects of Baffle Structure Variation on Heat Transfer Performance in a Shell-Tube Heat Exchanger (배플 구조변경이 Shell-Tube 열교환기의 열전달성능에 미치는 영향)

  • Hou, Rong-Rong;Cho, Joeng-Kwon;Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3014-3021
    • /
    • 2015
  • Shell-tube heat exchanger is widely applied in industrial field by easily manufacturing as to various size and flow patterns. In this study, by changing baffle's cut direction, tilt angle and rotational angle as well as by using SST (Shear Stress Transport) $k-{\omega}$ turbulence model in ANSYS FLUENT v.14, the heat transfer rate and pressure drop characteristics of inner shell will be analyzed to improve heat transfer ability. As a result of analysis, heat transfer performance according to cut direction of baffle has been improved with vertical model B and angle $45^{\circ}$ model C than horizontal model A. In addition, the tilt $10^{\circ}$ of the baffle and rotational angle $0^{\circ}-90^{\circ}-180^{\circ}-270^{\circ}$ of model D showed better result in heat transfer rate and pressure drop.

Numerical Analysis of Flow Phenomena in Cylindrical Shell with Baffle according to the Position of Inlet and Outlet (출.입구 위치에 따른 배플을 갖는 원통내 유동특성에 대한 수치해석)

  • Shin, Y.H.;Sayeed, S.M.;Jean, Y.C.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.15 no.6
    • /
    • pp.22-26
    • /
    • 2011
  • A numerical simulation on the flow field was carried out on the cylindrical shell with baffles. The steady incompressible 3-D Navier-Stokes solution is obtained with the actual operational condition and geometry of the heat exchanger. The effect of the location of inlet and outlet on the cylindrical shell with baffle is investigated by varying flow rate. The angle between the location of In/Outlet and baffle cutting part is $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$, $120^{\circ}$, $150^{\circ}$ and $180^{\circ}$. The present results show that the pressure drop is dependent on Reynolds number in the inlet area and position of inlet and outlet; i.e., the pressure drop increases with increasing Reynolds number and the pressure drop decreases with increasing angle between baffle cutting part and position of inlet and outlet.

Performance and flow field assessment of settling tanks using experimental and CFD modeling

  • Nouri, Alireza Zamani;Heydari, Mohammad Mehdi
    • Membrane and Water Treatment
    • /
    • v.8 no.5
    • /
    • pp.423-435
    • /
    • 2017
  • Settling Basins are one of the most important and popular methods for removal of suspended sediments irrigation and drainage networks or power canals taking off from an alluvial river and wastewater treatment plant. Improving the performance and so increasing sediment removal efficiency of settling basins by an alternative method is necessary. In the present work, the effect of baffle and its angle of attack with the flow (${\theta}$) on the sediment removal efficiency is investigated by conducting a series of experiments on a straight canal with 8 m length, 0.3 m width and 0.5 m height and 3 m length of basin equipped with an adjustable glass baffle. A numerical analysis has been carried out using ANSYS Fluent 3D software (a general purpose computational fluid dynamics simulation tool) for three Froude numbers from the experiments. The numerical and experimental results were found to match reasonably well.