• Title/Summary/Keyword: backward magnetic field

Search Result 12, Processing Time 0.027 seconds

The Analysts of PerformaneeCharacterlstics of a L.I.M. with taken into Conslderatlon of End Effects(l) (단부효과를 고려한 L.I.M.의 동작특성 해석 (1))

  • 임달호;이은웅;장석명
    • 전기의세계
    • /
    • v.31 no.4
    • /
    • pp.288-295
    • /
    • 1982
  • In this study, the characteristic equation of a double sided short stator linear induction motor, referred to as LIM excited by equivalent current sheet having linear current density was derived using Maxwell's electromagnetic field theory with its entry and exit, end effects taken into consideration. According to the treatment of several physical phenomena in the air-gap i.e. the magnetic flux density distributions, thrust-force, forward and backward travelling wave with decay, normal field, the fundamental data in this study are made reference to improve the characteristics of LIM, effectual electro-magnetic energy conversion devices.

  • PDF

Experimental Study of Quality Factor on Slot Slow Waveguide (스롯형 지파도파관의 Q치의 실험적 연구)

  • Kim, Won-Sop
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.585-587
    • /
    • 2009
  • A large diameter slot waveguide made backward wave oscillator is investigated experimentally. The parameters of slow wave structure are chosen so that the oscillation frequency is about 20 GHz. Plasma is produced by the beam and it has favorable effects on beam propagation and Cherncov oscillation. The output power strongly enhanced when the guiding magnetic field approaches to the fundamental electron cyclotron resonance.

Research about design and manufacture of Crossing High-Amplitude Magneto-Therapy own nerve system for Muscuoskeltal tissue rehalibitation treatment (근조직 재활치료를 위한 자계신경 자극시스템의 설계 및 구현)

  • Kim, Whi-Young
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.855-856
    • /
    • 2006
  • Magnetic nerve stimulation treatment is much backward real condition than other field. Specially, successful medical treatment introduction of magnetic field (MF) can was refered long ago in Avicenna's work, and is thought as age of medicine magnetology development recently. These development is achieved through biologist and biophysicist and clinician's joint effort, but, new mountings and relationship air tassel are developed steadily. Magnetic nerve stimulation treatment field designs treatment system by each function during long wave high-amplitude (traditional magneto therapy of greatly great that strong that) short time that CMF, VMF, PMF field etc. are representative but are HPMT technology in this research and manufacture and special quality did comparative analysis.

  • PDF

Frequency Tracking of Resonance Frequency Variation of L-C Circuits for Wireless Energy Transmission to Medical Devices in Human Organs

  • Gimm, Yoon-Myoung;Ju, Young-Jun;Lee, Yu-Ri;Lee, Dong-Yeol;Wang, Jong-Wook
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.4
    • /
    • pp.298-303
    • /
    • 2011
  • A capsular endoscope (CE) for inspection of the large intestine requires a motor for backward navigation against the autonomous travel in the intestine. This study proposes an HF power system for generating a magnetic field and for delivering wireless power to the internal or implanted medical devices. The magnetic field is generated by a wound coil (L) around a wooden frame, and the current is driven to the coil through a resonating capacitor (C). The characteristics of the resonance frequency shifting of the L-C series circuit are analyzed. A stable magnetic field intensity in the field coil is maintained by a specially designed frequency tracking system that automatically follows the L-C resonance frequency. Testing confirmed that the oscillation system tracks well the parameter changes of the electric components caused by the operating conditions or environmental variations.

The Study On Analysis Of The Characteristics For Capacitor Motor Having Space Harmonics In Its Magnetic Field (공간고주파자속을 가진 콘덴서 전동기의 특성해석에 관한 연구)

  • Keung Yul Oh
    • 전기의세계
    • /
    • v.24 no.1
    • /
    • pp.29-42
    • /
    • 1975
  • In this paper, the electrical angle between two winding axes in the stator of the capacitor motor is put optional angle, deviding the space harmonics in its magnetic field of two windings and the leakage flux into the forward revolving field and the backward one by the revolving-field theory, its equivalent circuit which consider mutual induction between two windings is depicted. In the depicted equivalent circuit, the rotor resistance for the fundamental flux is devided into the resistance for the rotor bar and endring, and the rotor leakage reactance for the fundamental is devided into the skew leadage reactance and the other, and each circuit constants for each harmonics is expressed in terms of the circuit constants for the fundamental, so it mades easy to determine the characteristics for the capacitor motor. As the circuit constant ratios to the magnetizing reactance of the fundamental are used, motors which have same circuit constant ratios should be resembled in their characteristics.

  • PDF

Implementation of a High Power Backward Wave Oscillator on Electron Beam Diode Structure Improvement (전자빔 다이오드 구조개선에 의한 대전력 후진파발진기의 구현)

  • Kim, Won-Sop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.897-903
    • /
    • 2009
  • We have designed the backward wave oscillator. A power-pulsed generator oscillated at 24 GHz has higher frequency than current one. It is very inportant to prevent microwave from going into the beam diode, since intence microwave will harmfully affect beam generation. Due to the axial mode operation, there exist a critial value of beam energy for the oscillation. By changing the condition at the SWS end, an enhanced performance of the K-band oversized BWO is observed in a low magnetic field region about 0.8T.

Research about design and manufacture of own nerve system for core formation rehalititation treatment (근조직 재활치료를 위한 자기신경 시스템의 설계 및 제작에 관한 연구)

  • Kim, Whi-Young;Choe, Jin-Yeong;Park, Seong-Jun;Kim, Jin-Yeong;Park, Seong-Jun;Kim, Hui-Je
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2171-2172
    • /
    • 2006
  • Magnetic nerve stimulation treatment is much backward real condition than other field. Specially, successful medical treatment introduction of magnetic field (MF) can was refered long ago in Avicenna's work, and is thought as age of medicine magnetology development recently. These development is achieved through biologist and biophysicist and clinician's joint effort, but, new mountings and relationship air tassel are developed steadily. Magnetic nerve stimulation treatment field designs treatment system by each function during long wave high-amplitude (traditional magneto therapy of greatly great that strong that) short time that CMF, VMF, PMF field etc. are representative but are HPMT technology in this research and manufacture and special quality did comparative analysis.

  • PDF

Research about design and manufacture of Crossing High-Amplitude Magneto-Therapy own nerve system for nervous tissue rehalibitation treatment (신경조직 재활치료를 위한Crossing High-Amplitude Magneto-Therapy 자기신경 시스템의 설계 및 제작에 관한 연구)

  • Kim Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.3
    • /
    • pp.263-270
    • /
    • 2006
  • Magnetic nerve stimulation treatment is much backward real condition than other field. Specially, successful medical treatment introduction of magnetic field (MF) can was refered long ago in Avicenna's work, and is thought as age of medicine magnetology development recently. These development is achieved through biologist and biophysicist and clinician's joint effort, but, new mountings and relationship air tassel are developed steadily. Magnetic nerve stimulation treatment field designs treatment system by each function during long wave high-amplitude (traditional magneto therapy of greatly great that strong that) short time that CMF, VMF, PMF field etc. are representative but are HPMT technology in this research and manufacture and special quality did comparative analysis.

  • PDF

A Study of High Power Microwave Output by K-band Waveguide (K-band 도파관을 이용한 대전력 마이크로파 출력장치 연구)

  • Kim, Won-Sop
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.588-591
    • /
    • 2009
  • We had experimental studies of microwave output generator. We experimented with a corrugate-shped K-band slow wave guide in the backward wave oscillator. It generated output 표 interaction between electron beam's generation and magnetic field. We estimated oscillation frequency at 24GHz by changing propagation velocity and group velocity. We identified movement by second harmonic of Cherencov interaction and slow cyclotron mode. In our study we achieved oscillation stabilization, generation of long pulse, improvement of oscillation efficiency and output.

Study of Losses segregation for Capacitor-Run Single phase Induction Motor (커패시터 구동형 단상 유도전동기의 손실분리 연구)

  • Kim, Kwang-Soo;Kim, Ki-Chan;Lee, Sang-Hoon;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.16-18
    • /
    • 2008
  • Several methods are proposed in the literature for losses segregation of single phase induction motor. Generally we could divide two methods for experimental determination of losses segregation for single phase induction motor. The one is relatively complicated method based on Parameter estimation of single phase induction motor. The other is simple method based on IEEE Standard 114. Segregation of losses in single phase induction motor is more complicated than that in three phase induction motor, because of the backward magnetic field component in the motor and multiplicity of different single phase type. In this paper, therefore, we studied losses segregation of capacitor-run single phase induction motor.

  • PDF