Residual Stress and Displacement Analysis of Thick Plate for Partial Penetration Multi-Pass Weldment (후판의 부분용입 다층용접에 대한 잔류음력 및 변형해석)

  • Kim, Seok;Bae, Sung-In;Song, Jung-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1813-1819
    • /
    • 2001
  • Partial penetration welding Joint defines that groove welds without steel backing, welded from on side, and groove weeds welded from both sides but without back gouging, that is. it has an unwelded portion at the root of the weld. In this study we analysed fur residual stress and displacement distribution on partial penetration welding condition of thick plate metal. For 25.4mm thick plate, theoretical residual stress and displacement analysis by finite element method using ABAQUS was carried out and compared with the experimental result using hole-drilling method. In results of the condition of partial penetration, it appeared that longitudinal stress at welding area was a little difference and transverse stress did not have any effect by partial penetration multi-pass welding. From a point of welding distortion in partial penetration multi-pass welding, it seemed to be better to control root face smaller than 6.35mm.

Factors Related to Fall in Elderly Patients with Osteoporosis (골다공증 노인 환자의 낙상 관련요인에 관한 연구)

  • Kim, Ju-Yeun;Lee, Young-Whee;Ham, Ok-Kyung
    • Korean Journal of Adult Nursing
    • /
    • v.21 no.2
    • /
    • pp.257-267
    • /
    • 2009
  • Purpose: The purpose of this study was to identify risk factors of fall and to examine its results among patients aged 60 and over diagnosed with osteoporosis. Methods: A retrospective descriptive survey was conducted with 91 patients admitted in a university hospital in a city. Data were collected using an interview method with a structured questionnaire, and were analyzed using descriptive statistics and multiple logistic regression. Results: In patients with osteoporosis, the intrinsic risk factors of falls were aging (OR = 3.742), gait disturbance (OR = 12.565), taking one or fewer medicine (OR = 7.873), and having two or more diseases (OR = 5.173). The extrinsic risk factors included the use of a bed (OR = 3.093), slippery floors (OR = 12.130), bathroom mat without anti-slip rubber backing (OR = 3.564), and presence of a night light on the passage from the bedroom to the bathroom (OR = 2.980). Conclusion: For the elderly aged over 70 who are most vulnerable to falls, screening tests such as bone mineral density (BMD) should be conducted in health examinations and the risk of fracture caused by osteoporosis should be communicated to the vulnerable elderly. Besides, development of new exercise programs combining weightbearing exercise is needed to prevent bone loss and increase functional activities.

  • PDF

A Study on an Ultrasonic Circular Array Transducer for Intra-vascular Ultra-sound Diagnosis (혈관 내부 진단용 원형 배열 초음파 트랜스듀서에 대한 연구)

  • 김희원;이수성;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.4
    • /
    • pp.329-336
    • /
    • 2003
  • Intra-Vascular Ultra-Sound (IVUS) transducers were developed for the application to diagnose coronary diseases. The transducer consists of 32 piezoelectric elements with a front insulation layer and a polymeric acoustic backing layer on a hollow alumina tube. The optimal geometrical structure of the transducer was designed through theoretical analysis of radiation patterns of the transducer. Samples of the IVUS transducers of the diameter of 3㎜ were fabricated to illustrate the design scheme. For the piezoelectric elements, 2-2 mode piezocomposite materials were employed. Experimental performance of the transducers showed good agreement with the design results, which verified feasibility of the transducer for IVUS applications.

Time-Delayed and Quantized Fuzzy Systems: Stability Analysis and Controller Design

  • Park, Chang-Woo;Kang, Hyung-Jin;Kim, Jung-Hwan;Park, Mignon
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.2 no.4
    • /
    • pp.274-284
    • /
    • 2000
  • In this paper, the design methodology of digital fuzzy controller(DFC) for the systems with time-delay is presented and the qualitative effects of the quantizers in digital implementation of a fuzzy controllers are investigated. We propose the fuzzy feed-back controller whose output is delayed with unit sampling period and period and predicted. the analysis and the design problem considering time-delay become very easy because the proposed controller is syncronized with the sampling time. The stabilization problem of the digital fuzzy system with time-delay is solved by linear matrix inequality(LMI) theory. Furthermore, we analyze the stability of the quantized fuzzy system. Our results prove that when quantization os taken into account, one only has convergence to some small neighborhood about origin. We develop a fuzzy control system for backing up a computer-simulated truck-trailer with the consideration of time-delay and quantization effect. By using the proposed method, we analyze the quantization effect to the system and design a DFC which guarantees the stability of the control system in the presence of time-delay.

  • PDF

Emission Characteristics of Volatile Organic Compounds (VOCs) from a Carpet (카페트에서 방출되는 VOCs의 방출특성)

  • 신동민;김창녕;김동술
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.40-49
    • /
    • 2003
  • This study has been conducted to identify and quantify the emissions of Volatile Organic Compounds (VOCs) from a new carpet. The carpet sample consists of polypropylene cushion and latex backing. The VOCs have been sampled on sorbent tubes and analyzed by thermal desorption unit and GC/MSD. For over 240 hours, concentration of VOCs has been measured in a small chamber made of stainless steel. With the measured data, emission factor and mass balance have been considered. The experiments have been conducted in accordance with ASTM D5116-97. The carpet has emitted a variety of VOCs, but in this study, 7 VOCs compounds have been considered: chlorobenzene, ethylbenzene, styrene, isopropylbenzene, bromobenzene, 2-chlorotoluene, and 1,2,3-trimethylbenzene. The results show that the concentrations of VOCs and the emission factors have exponentially decayed from relatively high level to low level with time. The gradients of the concentration of VOCs and emission factors are different for various components. It is found that styrene, 2-chlorotoluene are emitted more than others with higher concentrations.

Phonological Process of Children with Cleft Palate (구개파열 아동의 음음변동에 관한 연구)

  • Choi, Jae-Nam;Sung, Soo-Jin;Nam, Do-Hyun;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.16 no.1
    • /
    • pp.49-52
    • /
    • 2005
  • Background and Objectives : Children with cleft palate children may be imparied in articulation and resonance. This study examined the phonological process usage of 3-, 4- and 5- year old children with cleft palate. Materials and Method : Twenty seven children with cleft palat participated 3-, 4- and 5-year old children with cleft palate. The authors performed speech evaluation using picture consonants test for children with cleft palate. Percentage of consonants correct(PCC), mean value of each phoneme depends on articulation site and manner were evaluated. Results : In place of articulation, ommission of velar consonants were the most frequent. In manner of articulation, ommission of nasal consonants were the most frequent. Backing, glottal stop, was the most prominent phonological process children with cleft palate. Conclusion : These results may indicate that articulation disorder with cleft palate. and other articulation disorders differences should be considered in the interpretation of speech evaluations.

  • PDF

Residual Stress and Fracture Analysis of Thick Plate for Partial Penetration Multi-pass Weldment (후판 부분용입 다층용접의 잔류음력 및 파괴 해석)

  • Kim, Seok;Shim, Yong-Lae;Bae, Sung-In;Song, Jung-Il
    • Journal of Welding and Joining
    • /
    • v.19 no.6
    • /
    • pp.636-642
    • /
    • 2001
  • Partial penetration welding joint defines the groove welds that applies the one side welding which does not use steel backing and both side welding without back gouging, that is, the partial penetration welding joint leaves an unwelded portion at the root of the welding area. In this study, we analyzed the residual stress and fracture on the thick metal plates that introduced the partial penetration welding method. As results of using above mentioned welding method, we could draw a conclusion that longitudinal stress and traverse stress occurred around the welding area was so minimal and did not affect any influence. We also performed the fracture behavior evaluation on the partial penetration multi-pass welding with 25.4mm thick plate by using theJ-integral, which finally led us the conclusion that the partial penetration multi -pass welding method is more applicable and effective in handling the root face with less than 6.35mm.

  • PDF

KS 규격 안에 따른 터보분자펌프의 성능시험

  • 박미영;인상렬
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.46-46
    • /
    • 1999
  • 터보분자펌프(turbomolecular pump, TMP)는 각종 연구장비, 반도체 제조장치, 가속기, 핵융합 실험 장치 등 여러 분야에서 가장 널리 쓰이는 고진공 펌프로서 자리잡고 있다. 이런 TMP의 광범위한 사용에도 불구하고 성능평가에 관한 통일된 규격이 마련되어 있지 않다. 국제 규격협회(ISO)의 터보분자펌프 성능평가방법 시안을 토대로 제정중인 KS 규격은 아직 실험적인 근거를 자체적으로 가지고 있지 못하므로 앞으로 각 항목들에 대한 많은 실험이 수행되어야 한다. TMP의 성능을 나타내 주는 항목들 중 배기속도(pumping speed)와 압축비(compression ratio)는 가장 중요한 것들로서 다른 고진공 펌프 및 TMP 상호간의 성능을 비교할 수 있는 기본 항목이라 할 수 있다. 본 실험에서는 종래의 단순 TMP와 큰 기체유량에서도 안정된 배기속도를 유지하는 복합터보분자펌프(compound molecular pump, CMP)의 배기속도와 압축비 및 임계배압(critical backing pressure)을 KS 규격안대로 시험 평가하여 안의 평가방법과 기준의 타당성을 검토하고, 두 가지 다른 방식의 펌프에 적용할 수 있는지를 검토하였다. TMP 및 CMP 흡기구에 표준용기를 부착하고 수소 및 질소 기체를 사용하여 흡기구 압력을 변화시키면서 배기속도 및 압축비를 측정하고 배기구 압력을 변호시키면서 최대압축비 및 임계배압을 측정하였다. 흡기구의 압력측정에는 인출형 전리진공계(EG)를 사용하였고, 배기구의 압력측정은 전기용량의 격막진공계(CDG)와 피라니 진공계로 측정하였다. 진공계는 모두 회전식 점성진공계(SRG)로 교정한 후 사용하였다.

  • PDF

Design and Implementation of a Backup System for Digital Contents (디지털콘텐츠의 특성을 고려한 백업 시스템의 설계 및 구현)

  • Lee Seok Jae;Yun Jong Hyun;Hwang Sok Choel;Yoo Jae Soo
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.2
    • /
    • pp.105-116
    • /
    • 2006
  • With the development of IT technology, the amount of digital contents used in various environments of wired/wireless networks have been increased hugely and rapidly To protect the loss of the digital contents from the sudden accident, continuous data backup is required. In this paper, we design and implement the backup system that stores digital contents in backup storage by objectifying the contents with a unit of I/O size and giving them the unique E using the properties of digital contents to avoid duplicated store of the same data. The backup system reduces the amount of backup data efficiently by backing up the only one copy of the duplicated data. as a result, the backup system can back up the digital contents more efficiently in a constrained storage space.

  • PDF

Change of Surface and Electrical Characteristics of Silicon Wafer by Wet Etching(1) - Surface Morphology Changes as a Function of HF Concentration - (습식 식각에 의한 실리콘 웨이퍼의 표면 및 전기적 특성변화(1) - 불산 농도에 따른 표면형상 변화 -)

  • Kim, Jun-Woo;Kang, Dong-Su;Lee, Hyun-Yong;Lee, Sang-Hyeon;Ko, Seong-Woo;Roh, Jae-Seung
    • Korean Journal of Materials Research
    • /
    • v.23 no.6
    • /
    • pp.316-321
    • /
    • 2013
  • The electrical properties and surface morphology changes of a silicon wafer as a function of the HF concentration as the wafer is etched were studied. The HF concentrations were 28, 30, 32, 34, and 36 wt%. The surface morphology changes of the silicon wafer were measured by an SEM ($80^{\circ}$ tilted at ${\times}200$) and the resistivity was measured by assessing the surface resistance using a four-point probe method. The etching rate increased as the HF concentration increased. The maximum etching rate 27.31 ${\mu}m/min$ was achieved at an HF concentration of 36 wt%. A concave wave formed on the wafer after the wet etching process. The size of the wave was largest and the resistivity reached 7.54 $ohm{\cdot}cm$ at an 30 wt% of HF concentration. At an HF concentration of 30 wt%, therefore, a silicon wafer should have good joining strength with a metal backing as well as good electrical properties.