• Title/Summary/Keyword: back-fire control

Search Result 29, Processing Time 0.025 seconds

A Study on the Fire Safety Measure of Pumped Storage Power Plant (양수발전소의 화재안전 대책에 관한 연구)

  • Kim, Yoo-Shik
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.125-130
    • /
    • 2006
  • Pumped storage power plant is a system of generating electricity with hydroelectric power, in which at times of low electrical demand such as during nights, excess generation capacity of many power plants is used to pump water into the higher reservoir, and when there is higher demand, water is released back into the lower reservoir through a turbine, generating electricity. As pumped storage power plants across the nation are not on building registry under "the Article 6 of the Special Act by the Development of Power Resources", they are classified as a structure, not as a building. As a result, permit of fire protection facility is unnecessary, and fire protection administration is excluded from approval to completion of construction. Therefore, this study is to improve problems in accordance with the application of "he Article 6 of the Special Act by the Development of Power Resources", repair of facilities and problems with safety control to effectively prevent similar damages from repeatedly happening to pumped storage power plants in operation or under construction nationwide during a fire.

The Development of the Ignition Spark Timing Conversion System for LPG/Gasoline Bi-fuel Vehicle (LPG 및 Gasoline 겸용 차량의 엔진 점화시기 변환 제어시스템 개발)

  • 전봉준;양인권;김재국;김성준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.117-123
    • /
    • 2003
  • In a bi-fuel engine using gasoline and LPG fuel, with the current ignition timing for gasoline being used, the effective performance could not be taken in LPG fuel supply mode. The ignition timing in LPG fuel mode must be advanced much more than that of gasoline mode for the compensation of its lower flame speed, due to engine torque drop. This study aims to develop the control system for ignition spark timing conversion which is composed of hardwares and control algorithm for gasoline/LPG engine. We propose the control system which can advance the ignition spark timing in LPG fuel mode more than used in gasoline fuel mode. The advance of ignition timing is achieved by change of the ignition dwell time of coil igniter. The engine torque and F/E(Fuel-Economy) in LPG fuel mode are measured to evaluate the difference of engine performance between before and alter changing ignition spark timings. The engine torque and F/E are increased respectively, which proves the developed control system is effective so much for gasoline and LPG bi-fuel engine.

Design and Control of a Quad-Rotor (쿼드로터 비행체의 설계 및 제어)

  • Shim, Sanghyun;Kim, Ji-Chul;Yang, Sungwook;Cheon, Dong-Ik;Lee, Sangchul;Oh, Hwa-Suk;Kang, Min-Young;Keum, Dong-Kyo
    • Journal of Aerospace System Engineering
    • /
    • v.3 no.1
    • /
    • pp.36-41
    • /
    • 2009
  • Quad-rotor is one kind of a rotorcraft in Unmanned Aerial Vehicle (UAV), which consists of four rotors in total and fixed-pitch blades located at the four corners. This vehicle is emerging as popular platform for UAV research due to the simplicity of its construction, the ability of hovering and the vertical take-off and landing (VTOL) capability, etc. Because of those specific capabilities, this vehicle can be applied to many fields: search and rescue, mobile sensor networks, fire observation, etc. However a quad-rotor is much affected by the disturbance due to the characteristics of structure. So this vehicle needs attitude control for stabilizing. In this paper, we design the control law for automatic stabilization. The PID controller is used to control a brushless DC motor. And an accelerometer is used to measure the roll and pitch angles of a quad-rotor.

  • PDF

A Case Study for SMRT Train Open Doors Control System (도시철도의 열차출입문제어에 관한 연구)

  • Won, Yu-Duck;Shim, Won-Sub
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.941-946
    • /
    • 2006
  • It followed in system development and SMRT(Seoul Metropolitan Rapid Transit Co)System reached to an automatic train operation(ATO) and driverless operation(DLM) from the manual operation due to the train driver. The train like the general bus or the car vehicle was not serial riding in a car and the Parallel concept which the numerous passenger rides in a car simultaneously occur frequently the charge of the train driver unmanned bitterly from existing manual handling was a possibility of doing, train open door control(ODM) which bites also ATO, it handles it minimized. Like this ATO/DLM, the control system which bites being a Wayside to Train communication for immediacy, it is a system of the Vital concept the immediacy of the citizen Data evil the radio information transmission and the train of the interface which is accurate from unmanned operation and, will decipher, will accomplish it will guarantee. It respects the passenger accident prevention and an air question environment improvement from subway platform and phul leys the screen door of Platform(PSD) with the fire tube frost it refers and part it treats and to sleep it does, ODM which bites is accuracy and immediacy of altitude and when seeing from the viewpoint which demands the trust of altitude, ODM system the trust of car incest interface in the equipment construction which is safe and the comparative analysis back of the system analysis against the control which bites and case study and other subway system it leads from the research which it sees and signal - train in base grudge to sleep it contributes it does.

  • PDF

A Study of Backfire Control in a Hydrogen-Fueled Engine with External Mixture Using Changes of Valve Overlap Period (밸브오버랩기간 변화에 의한 흡기관 분사식 수소기관의 역화억제에 관한 연구)

  • Kang, J.K.;Cong, Huynh Thanh;Noh, K.C.;Lee, J.T.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3311-3316
    • /
    • 2007
  • To analyze the influence of valve overlap period on a backfire occurrence, the single cylinder research engine with MCVVT(Mechanical Continuous Variable Valve Timing) system is developed and backfire limit equivalence ratio defined as fuel-air ratio equivalence ratio at which backfire occurs is examined according to various valve overlap period. The MCVVT is the system to control valve overlap period by mechanical device. It is estimated that the lower valve overlap period has the higher backfire limit equivalence ratio though the same energy is supplied. When the valve overlap period is changed from 30$^{circ}$ CA to 0$^{circ}$ CA, backfire limit equivalence ratio is increased 74%, approximately. It means that valve overlap period is concern in backfire occurrence, and may be one of the methods for controlling back fire occurred in a $H_2$ engine.

  • PDF

Some Effects on AT Vehicle's Sudden Acceleration due to Stepping Motor for Compensation of Idle Speed (공회전속도 조절용 스텝모터가 AT차량의 급발진 현상에 미치는 영향)

  • Kim, Jong-Il;Cha, Jeong-Yeun;Son, Joeong-Bae
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.879-885
    • /
    • 2000
  • This study is carried out to make clear the reason of occurrence of sudden acceleration incident of AT vehicle. The stepping motor is used to control the engine speed at idle by compensating the volume of air. By the way it's valve is contaminated by blow-by gas, deposit and back fire etc. This contamination could occur the load of motor at low temperature. This plays an important role in damaging the motor's coil with the motor's performance interfered. If it's coil is damaged the ISC could malfunction. If these phenomena occur, the speed of engine may increase or the engine may stall with hunting.

  • PDF

Development of PLC by using micro controller for the distributed fire alarm system (마이크로 콘트롤러를 이용한 분산형 방재 시스템용 중계기 개발)

  • Han, Kyong-Ho;Lee, Ki-Sik;Hwang, Seok-Yong;Kim, Jong-Chol
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1243-1247
    • /
    • 1996
  • In this paper, a small PLC system is designed and developed for the distributed building control and fire control system. It uses 8031, a 8-bit micro controller from Intel Inc. The size of the PLC is $7cm{\times}8cm$ and the PLC can accept 4 sensor inputs and drive 4 relay outputs, which operates at 24V. Multiple access of PLC by one host computer is implemented by assigning a unique 10 to each PLC, which ranges from 0 to 126. The operation starts by sending a command packet from host computer to a PLC and the PLC of the same 10 fetches the command packet by comparing the first byte of the command packet with its own 10. The PLC is programmed to perform a various functions and the function is selected by the content of the command byte, which is the second byte of the command packet. The third byte, which is the last byte, is a checksum byte. The checksum byte is the sum of the first byte and the second byte and is used to detect the communication error. Depending on the content of the command byte, PLC performs the desired function and returns the response packet back to the host computer. The response packet is also a three-byte packet, 10 byte, response byte and checksum byte. For the independent operation of PLC without being controlled by the host computer, variable length RULE data packet is sent to PLC. In case the communication line is broken, the PLC perform the independent operation by referencing the RULE data. The applicable areas are; building automation system, distributed factory automation, measurement of temperature of toxic or dangerous area.

  • PDF

A Study on the Development of ICT-based Disaster Prevention Monitoring System for Shipbuilding Safety (선박 안전 건조를 위한 ICT 기반 재해방지 감시시스템 개발에 관한 연구)

  • Kim, Gi-Back;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.785-788
    • /
    • 2014
  • Even though Korea is No.1 shipbuilding country around the world, there have been a lot of accident and man-made calamity incurring in shipyards these days. Therefore most of Korea major shipyard and mid-small size shipyard deeply agonize about safety management countermeasure. As a result of it, many shipyards pour their effort on developing man watching system, PF wireless communication system, portable measuring system to prevent from accident such as fire, suffocation incurring. In this paper, analyze conventional accident & man-made calamity preventing system adopted by most of shipyard and enable the user to watch accident for 24 hours and notify it to user when it is incurring through state of the art ICT technology. And as a result of it the user can prevent the accident and man-made calamity at the beginning.

  • PDF

Study for Failure Cases on Engine Electronic Control Computer in Liquid Petroleum Gas vehicle (액화석유가스 자동차 엔진의 전자제어 컴퓨터의 고장사례 연구)

  • Lee, Il-Kwon;Kim, Young-Gyu;Kook, Chang-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.28-33
    • /
    • 2011
  • The purpose of this paper analyzes and studies to improve the failure cases on the computer that one of electronic control elements for engine in liquified petroleum gas vehicle. The first case, it certified the non-starting phenomenon of engine that it's electronic control unit didn't control the fuel for idle speed actuator because of no given action signal in slow-cut solenoid valve. The second case, it knew the bad condition phenomenon of engine and back-fire by the wire melting of ignition coil and firing of transistor being inside ECU. The third case, it certified the action stoping phenomenon of engine and malfunctioning signal for engine ECU because of leakage of current and an excess current by moisture inflowing inside ECU curcuit plate. Therefore, it is thought that will elevate the durability and reliability of engine computer throughout procure of quality.

A Study on the Performance Improvement Plan of Inflowing Air Emission (유입 공기의 배출 성능 개선방안에 관한 연구)

  • Lee, Hye-Young
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.241-251
    • /
    • 2022
  • Purpose: In the event of a fire in a high-rise building, if the smoke control area is not effectively protected, smoke or flames enter the stairwell, making it difficult to evacuate. When inflowing air is discharged from a closed corridor, a negative pressure is formed in the corridor, the pressure in the smoke control area becomes excessively high, and the force required to open the door during evacuation is exceeded. Also, if the air introduced into the hallway is not exhausted, the smoke may flow back into the smoke control area. This paper tried to identify the problems caused by the inflowing air and to find out how to improve the performance. Method: Using the CONTAM program, simulations were performed with the basic conditions and the modified conditions. Result: If the inflowing air was discharged from the sealed corridor, overpressure occurred in the Smoke Control Area and exceeded the opening force, and the prevent smoke backflow was insufficient in the layer where the inflowing air was not discharged. Conclusion: "Differential pressure exhaust damper" application, simultaneous opening of two exhaust dampers, and automatic window installation between corridors and outdoors improved the exhaust performance of inflowing air.