• Title/Summary/Keyword: back titration

Search Result 22, Processing Time 0.024 seconds

Synthesis, Characterization and Application of Poly(4-Methyl Vinylpyridinium Hydroxide)/SBA-15 Composite as a Highly Active Heterogeneous Basic Catalyst for the Knoevenagel Reaction

  • Kalbasi, Roozbeh Javad;Kolahdoozan, Majid;Massah, Ahmadreza;Shahabian, Keinaz
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.9
    • /
    • pp.2618-2626
    • /
    • 2010
  • In this paper poly (4-methyl vinylpyridinium hydroxide)/SBA-15 composite was prepared as a highly efficient heterogeneous basic catalyst by in situ polymerization method for the first time. It was characterized by XRD, FT-IR, BET, TGA, SEM and back titration using NaOH. This catalyst exhibited the excellent catalytic activities for the Knoevenagel condensation of various aldehydes with ethyl cyanoacetate. Over this catalyst, ${\alpha},{\beta}$-unsaturated carbonyl compounds were obtained in the reasonable yield at $95^{\circ}C$ in 10 - 30 min in $H_2O$ as a solvent with a 100% selectivity to the condensation products. Catalyst could be easily recycled after the reaction and it could be reused without the significant loss of activity/selectivity performance. No by-product formation, high yields, short reaction times, mild reaction conditions and operational simplicity with reusability of the catalyst were the salient features of the present synthetic protocol. Presence of $H_2O$ as a solvent was also recognized as a "green method".

Formation of Complex Between Polyelectrolytes and pH/Temperature Sensitive Copolymers (고분자전해질과 pH/온도감응성 고분자 사이의 복합체 형성에 관한 연구)

  • Yoo, Mi Kyong;Sung, Yong Kiel
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.1
    • /
    • pp.84-91
    • /
    • 1998
  • Random copolymers of N-isopropyl acrylamide (NIPAAm) and acrylic acid (AAc) which exhibit temperature- and pH-responsive behavior were synthesized by free-radical polymerization. The copolymers were characterized by means of FT-IR spectrometry and titration. The influence of polyelectrolyte on the lower critical solution temperature (LCST) of pH/temperature-sensitive polymers was investigated in the pH range of 2-12. The LCSTs of PNIPAAm/water in poly(NIPAAm-co-AAc) were determined by cloud-point measurements. A polyelectrolyte complex was prepared by mixing poly(NIPAAm-co-AAc) with poly(allylamine) (PAA) or poly(L-lysine) (PLL) solutions as anionic and cationic polyelectrolytes, respectively. Back titration was performed to determine the content of AAc and to study the effect of comonomer ionization on the LCST. The LCSTs of PNIPAAm/water in the copolymers were strongly affected by pH, presence of polyelectrolyte, AAc content, and charge density on the polymer. The polyelectrolyte complexes were formed at neutral condition. The influence of more hydrophobic PLL as polyelectrolyte on the cloud-point of PNIPAAm/water in the copolymer was stronger than that of poly(allylamine) (PAA).

  • PDF

Chemical Analysis and Thermoelectric Properties of the PbSnTe Semiconductors (화학조성에 따른 PbSnTe계 반도체의 열전특성조사)

  • Oh, Kyu-Whan;Oh, Seung-Mo
    • Applied Chemistry for Engineering
    • /
    • v.1 no.1
    • /
    • pp.83-90
    • /
    • 1990
  • The semiconducting $(Pb_1\;_xSn_x)_1$ $_yTe_y$, one of the low - temperature thermoelectric materials, has been prepared and its chemical composition and nonstoichiometry has been analyzed. The content of Pb in the specimens was determined by the complexometric back - titration method with EDTA and Pb(II) standard solutions. Te - content was analyzed with the redox titration method. The electrical conductivity and the thermoelectric power have also been measured by the DC 4 - probe and the heat-pulse technique, respectively. All of the specimens showed a nonstoichiometric behavior in their chemical compositions (Te excess), thus gave rise to a p - type semiconducting property, and the nonstoichoimetry became bigger as the Sn - content increased. The thermoelectric power vs. temperature results have been analyzed upon the basis of the Fermi level vs. temperature profiles in the saturation regime. The specimen of x=0.1 evolved a transition from p - to n - type property at about 670K, which has been explained by the fact that the mobility of electrons is bigger than that of holes in the temperature range of the intrinsic regime.

  • PDF

Absorption Properties of $CO_2$ in Aqueous Solutions of Piperazine, Piperidine, Cyclohexylamine (Piperazine, Piperidine, Cyclohexylamine 수용액에 대한 이산화탄소의 흡수특성)

  • Song Ho-Jun;Lee Seoungmoon;Song Hocheol;Ahn Se-Woong;Park Jin-won
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.219-225
    • /
    • 2005
  • for the removal of carbon dioxide in flue gas, which is the main cause of the global warming, chemical absorption methods were widely used for years. Alkanolamines such as MEA, AMP, MDEA are mainly used as an absorbent. In this study, cyclic amines - Piperazine, Piperidine and Cyclohelylamine are investigated to compare the chemical solubilities, absorption capacities and rate ot reaction. In conclusion, Piperazine is the most effective absorbent of $CO_2$ and ran be the excellent alternative to the former absorbents. Experiments were performed at 5, 10, 15 weight percent, 30, 40, $50^{\circ}C$, and the gas solubilities are determined by back-titration method, and using Gas Chromatography the absorption rate was compared.

The Effects of Laundering Conditions on Calcium Deposition on the Fabric (세척조건이 직물에의 Calcium 침착에 미치는 영향)

  • Moon Young Ae;Kahng He Won;Kim Sung Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.5 no.1
    • /
    • pp.9-14
    • /
    • 1981
  • The influence of laundering conditions on calcium deposition on the fabric was studied by repeated laundering the cotton fabric with soap in the hard water of 200 P.P.M. $CaCO_3$. The experimental variables were: 1) soap concentrations ($0.06\%$, $0.13\%$, $0.25\%$), 2) water contents in the fabric after hydroextraction. ($65\%$, $150\%$, $315\%$), 3) builders (Na-EDTA, sodium carbonate, sodium metasilicate), 4) washing cycle (5, 10, 15, 20 cycles). The fabric was washed for 15 minutes at $23\pm1^{\circ}C$ in a washing machine (Model; Gold Star Wp-2005) under the similar conditions with those of home laundering, and rinsed 5 times for 5 minutes. The amount of calcium deposits on the fabric was determined by the EDTA-Back titration method described by Wasserman and Basch. Results of this study were follows: 1) The amount of calcium deposits on the fabric increased with increasing wash cycles. 2) During the rinsing process, residual calcium content on the fabric increased with water content in the fabric after hydroextraction. 3) The amount of calcium deposits on the fabric decreased with the increasing soap concentration above the equivalent amount of calcium ion content in the water. 4) Sequestering agents and alkaline builders influenced the amount of calcium deposits on the fabric. The amount of calcium deposits on the fabric was in the order of sodium metasilicate, sodium carbonate, nonbuilder, and EDTA.

  • PDF

Fabrication of Endothelial Cell-Specific Polyurethane Surfaces co-Immobilized with GRGDS and YIGSR Peptides

  • Choi, Won-Sup;Bae, Jin-Woo;Joung, Yoon-Ki;Park, Ki-Dong;Lee, Mi-Hee;Park, Jong-Chul;Kwon, Il-Keun
    • Macromolecular Research
    • /
    • v.17 no.7
    • /
    • pp.458-463
    • /
    • 2009
  • Polyurethane (PU) is widely used as a cardiovascular biomaterial due to its good mechanical properties and hemocompatibility, but it is not adhesive to endothelial cells (ECs). Cell adhesive peptides, GRGDS and YIGSR, were found to promote adhesion and spreading of ECs and showed a synergistic effect when both of them were used. In this study, a surface modification was designed to fabricate an EC-active PU surface capable of promoting endothelialization using the peptides and poly(ethylene glycol) (PEG) spacer, The modified PU surfaces were characterized in vitro. The density of the grafted PEG on the PU surface was measured by acid-base back titration to the terminal-free isocyanate groups. The successful immobilization of pep tides was confirmed by amino acid analysis, following hydrolysis, and contact angle measurement. The uniform distribution of peptides on the surface was observed by scanning electron microscopy (SEM) and atomic force microscopy (AFM). To evaluate the EC adhesive property, cell viability test using human umbilical vein EC (HUVEC) was investigated in vitro and enhanced endothelialization was characterized by the introduction of cell adhesive peptides, GRGDS and YIGSR, and PEG spacer. Therefore, GRGDS and YIGSR co-immobilized PU surfaces can be applied to an EC-specific vascular graft with long-term patency by endothelialization.

The Effects of Builders on Calcium Deposition on the Fabric (세척시 조제의 종류가 직물에의 Calcium 침착에 미치는 영향)

  • Park Moon He;Kahng Hewon;Kim Sung Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.6 no.1
    • /
    • pp.9-15
    • /
    • 1982
  • The influence of builders on calcium deposition on the fabric was studied by laundering the cotton fabric with sodium carbonate, sodium metasilicate, sodium tripolyphosphate and built detergents in hard water. The laundry variables were: 1) Washing cycles: 5, 10, 20, 30 and 40 cycles. 2) Water hardness: 100 ppm, 150 ppm, 200 ppm and 300 ppm. 3) Builders: $Na_2\;CO_3,\;Na_2\;SiO_3$ and STPP. 4) Detergents: Na-DBS, $Na-DBS+Na_2CO_3,\;Na-DBS+Na_2\;SiO_3,\;Na-DBS+STPP,\;Na-DBS+Na_2\;CO_3+STPP$, and $Na-DBS+Na_2\;SiO_3+STPP$. The fabric was washed for 15 minutes at 23+$1^{\circ}C$ in a washing machine(Gold Star WP 3007) under the similar condition with those of home laundering, and rinsed 3 times in the same water hardness for 5 minutes. The calcium deposits on the fabric was determined by EDTA-BACK titration methods. The results of this study were as follows: 1) The amount of calcium deposits on the fabric was increased with increasing wash cycles. This deposit was due to the build up of insoluble calcium carbonate. 2) As the water hardness increased, the amount of calcium deposits on the fabric was increased. 3) Alkaline builders, such as, $Na_2CO_3$ and $Na_2SiO_3$, promoted calcium deposition on the fabric, however STPP prevented calcium deposition on the fabric. 4) Fabric laundered with $Na-DBS+Na_2CO_3$ showed the highest calcium deposits on the fabric, and decreased with the order of $Na_2CO_3$, $Na-DBS+Na_2SiO_3$, and Na-DBS. And fabrics washed with phosphate-built detergents showed a small amount of calcium deposition.

  • PDF

A Comparison Study of Alkalinity and Total Carbon Measurements in $CO_2$-rich Water (탄산수의 알칼리도 및 총 탄소 측정방법 비교 연구)

  • Jo, Min-Ki;Chae, Gi-Tak;Koh, Dong-Chan;Yu, Yong-Jae;Choi, Byoung-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.1-13
    • /
    • 2009
  • Alkalinity and total carbon contents were measured by acid neutralizing titration (ANT), back titration (BT), gravitational weighing (GW), non-dispersive infrared-total carbon (NDIR-TC) methods for assessing precision and accuracy of alkalinity and total carbon concentration in $CO_2$-rich water. Artificial $CO_2$-rich water(ACW: pH 6.3, alkalinity 68.8 meq/L, $HCO_3^-$ 2,235 mg/L) was used for comparing the measurements. When alkalinity measured in 0 hr, percent errors of all measurement were 0~12% and coefficient of variation were less than 4%. As the result of post-hoc analysis after repeated measure analysis of variance (RM-AMOVA), the differences between the pair of methods were not significant (within confidence level of 95%), which indicates that the alkalinity measured by any method could be accurate and precise when it measured just in time of sampling. In addition, alkalinity measured by ANT and NDIR-TC were not change after 24 and 48 hours open to atmosphere, which can be explained by conservative nature of alkalinity although $CO_2$ degas from ACW. On the other hand, alkalinity measured by BT and GW increased after 24 and 48 hours open to atmosphere, which was caused by relatively high concentration of measured total carbon and increasing pH. The comparison between geochemical modeling of $CO_2$ degassing and observed data showed that pH of observed ACW was higher than calculated pH. This can be happen when degassed $CO_2$ does not come out from the solution and/or exist in solution as $CO_{2(g)}$ bubble. In that case, $CO_{2(g)}$ bubble doesn't affect the pH and alkalinity. Thus alkalinity measured by ANT and NDIR-TC could not detect the $CO_2$ bubble although measured alkalinity was similar to the calculated alkalinity. Moreover, total carbon measured by ANT and NDIR-TC could be underestimated. Consequently, it is necessary to compare the alkalinity and total carbon data from various kind of methods and interpret very carefully. This study provide technical information of measurement of dissolve $CO_2$ from $CO_2$-rich water which could be natural analogue of geologic sequestration of $CO_2$.

Chromium(VI) Removal from Aqueous Solution using Acrylic Ion Exchange Fiber (아크릴계 이온교환섬유를 이용한 수중 크롬(VI) 제거)

  • Nam, Aram;Park, Jeong-Ann;Do, Taegu;Choi, Jae-Woo;Choi, Ungsu;Kim, Kyung Nam;Yun, Seong-Taek;Lee, Sanghyup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.3
    • /
    • pp.112-117
    • /
    • 2017
  • Ion exchange fiber, PADD was synthesized by the reaction between PAN based acrylic fiber and DETA with $AlCl_3{\cdot}6H_2O$, and was analyzed by FT-IR and SEM to investigate its characteristics. The experimental results of Cr(VI) removal by PADD were better fitted with Langmuir adsorption isotherm, and the maximum uptake value ($Q_{max}$) was calculated to be 6.93 mmol/g. The kinetic data can be well described by Lagergen pseudo-second order rate model. The Cr(VI) adsorption capacity of PADD was 4.11 mmol/g at pH 2, which shows the effect of pH changes on the removal of Cr(VI). The adsorption selectivity of Cr(VI) was higher than phosphate and As(V). Total ion exchange capacity of PADD was 4.70 mmol/g, which was measured by acid-base back titration.

A Study on the Removal of Deposited Calcium on the Cotton Fabric. (직물에 침착된 Calcium의 제거에 관한 연구)

  • Han Hae Won;Kahng He Won;Kim Sung Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.7 no.2
    • /
    • pp.19-25
    • /
    • 1983
  • The purpose of this study was to investigate the effects of laundry variables and additives on the removal of deposited calcium on the cotton fabric. Samples of calcium deposited fabric was made by treating fabric with $CaC1_2$ and $Na_2CO_3$ solution subsequently. The experimental variables were: 1) NaOH concentration ($0.0001\%$, $0.0005\%$, $0.001\%$, $0.005\%$, $0.01\%$) 2) Alkaline builders(sodium carbonate, sodium meta silicate) 3) Sequestering agents(STPP and EDTA concentration: $0.02\%$, $0.04\%$, $0.06\%$, $0.08\%$, $0.1\%$, $0.15\%$, $0.2\%$) 4) Temperatures($25\pm1^{\circ}C$, $40\pm1^{\circ}C$, $60\pm1^{\circ}C$) 5) Edge-abrasion to the removal of deposited calcium on the cotton fabric. The fabric was washed for 15 minutes in a washing machine(Model: Gold Star WP-3007) or Launder-0-meter(40$\~$45 r.p.m., Toyo Rika Instrument Inc.) and rinsed 3 times per every rinsing time. The amount of calcium deposits on the fabrics was determined by EDTA-back titration methods and edge-abrasion was evaluated by ASTM D 3886 method. The results of this study were as follows: 1) pH of surfactant solution(NaOH concentration) did not influence on the removal of deposited calcium on the cotton fabric. 2) Added alkaline builders did not influence on the removal of deposited calcium on the cotton fabric. 3) It was shown that STPP and EDTA were effective to remove deposited calcium. The removal of deposited calcium on the cotton fabric was proportionally increased with increasing concentration of STPP and EDTA. At high concentration, however, the rate was rather decreased with increasing concentration. 4) The temperature of washing solution did not influence on the removal of dedosited calcium on the cotton fabric. 5) As the removal of deposited calcium on the cotton fabric was increased, the rate of edge-abrasion of the fabric was gradually increased.

  • PDF