• 제목/요약/키워드: average force

검색결과 954건 처리시간 0.021초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

곡성 동악산 청류구곡(淸流九曲)의 형태 및 의미론적 특성 (Characteristic on the Layout and Semantic Interpretation of Chungryu-Gugok, Dongaksan Mountain, Gokseong)

  • 노재현;신상섭;허준;이정한;한상엽
    • 한국전통조경학회지
    • /
    • 제32권4호
    • /
    • pp.24-36
    • /
    • 2014
  • 동악산 청류구곡 일원은 아름다운 계류를 따라 와폭(臥瀑)과 담(潭), 소(沼), 대(臺) 등의 암반경관과 성리문화의 전형으로 향유되어온 구곡문화가 실증적으로 대입된 사례로, 1872년 곡성현 지방도에서 "삼남제일암반계류 청류동(三南第一巖盤溪流 淸流洞)"으로 명기된 바와 같이 풍치가 탁월한 승경처임을 보여준다. 경물(景物)과 경구(警句)가 육로와 수로에 쌍으로 설정되어 차별성을 갖는 청류구곡은 일제강점기인 1916년 이전, 정순태와 조병순의 주도로 설정된 것으로 판단되지만 성리학자들은 물론 불교지도자, 독립운동가 등 선현들의 장구처 등이 다수 발견되는 것으로 볼 때 오래전부터 명인(名人)들의 산수탐방과 은일처로 활용된 것으로 추정된다. 도림사계곡의 기반암 암상에 구성된 청류구곡은 산지형 하천으로 총 길이 약 1.2km, 평균 곡거리 149m로 국내 여타 구곡에 비해 짧은 것으로 나타났다. 전남지역에서 유일하게 확증된 동악산 3개 구곡의 바위글씨는 총 165건으로 국내에서 가장 많은 바위글씨의 집결지로 판단된다. 특히 112개소로 집계된 청류구곡 바위글씨의 내용 분석결과, '수신(修身)'의 의미가 49점(43.8%)으로 가장 많았으며 다음으로 '인명' 21건(18.8%), '경물' 16건(14.2%), 장구처 등 장구지소' 12건(10.6%) 등이었고 '시구(詩句)'가 차지하는 비율은 6건(3.6%)으로 나타났다. 육로상의 제1곡 쇄연문과 수로상의 제9곡 제시인간별유천(除是人間別有天)은 박세화(朴世和)가 충북 제천에 설정한 용하구곡(用夏九曲)의 제1곡 홍단연쇄(虹斷烟鎖) 및 제9곡 제시인간별유천과 일치하는 것으로 동일한 시원(始原)을 갖는 구곡명으로 유추된다. 또한 육로상 제6곡 대은병(大隱屛)은 주자 무이구곡의 제7곡과 일치하는 것으로 구곡원림의 거점으로 인식되며, 7곡과 8곡 사이의 '암서재(巖棲齋)'와 '포경재(抱經齋)' 바위글씨와 석축 흔적 등은 무이구곡 은병봉 아래 무이정사와 비견되는 것으로, 기호사림의 청류동 활동거점으로 파악된다. 선사어제(鮮史御帝), 보가효우(保家孝友, 고종), 사무사(思無邪, 명나라 의종), 백세청풍(百世淸風, 주자), 청류수석 동악풍경(흥선 대원군) 등 명인들의 명구들이 망라된 동악산 구곡은 높은 유가미학적 가치를 표출함은 물론 의미론적 상징문화경관의 보고라 할 수 있다. 아울러 청류구곡은 수심양성을 위한 유가적 가치체계와 불교 및 도교적 관념 등이 공존하는 유불선(儒彿仙) 3교 문화경관의 결집체로 특성이 부각된다. 청류구곡은 최익현(崔益鉉), 전우(田愚), 기우만(奇宇萬), 송병선(宋秉璿), 황현(黃玹) 등으로 대변되는 조선 후기 사림계층이 성리학의 도통의식을 계승하고 '위정척사'와 '존왕양이(尊王攘夷)', '항일의지 고취' 등의 수단으로 설정되고 활용하는 과정에서 배태(胚胎)된 항일 역사문화 항쟁의 거점으로서 장소성과 의미론적 특성에 충일하다.

노폐계(老廢鷄)를 이용(利用)한 육제품(肉製品) 개발(開發)에 관한 연구(硏究) (A Study on Development of New Products by Old Chicken Meat)

  • 한성욱;이규승;장규섭;전창기
    • 농업과학연구
    • /
    • 제7권2호
    • /
    • pp.87-102
    • /
    • 1980
  • 노폐계(老廢鷄)의 이용성(利用性) 증대방안(增大方案)의 하나로 White Leghorn(WL)종(種)과 Rhode Island Red(RIR)종(種) 노폐계(老廢鷄)의 도체성적(屠體成績)을 조사(調査)하고 아울러 노폐계육(老廢鷄肉)을 이용(利用)하여 건조육제품(乾燥肉製品)을 제조(製造)하여 개발(開發) 가능성(可能性)을 검토(檢討)한 결과(結果) 다음과 같은 결론(結論)을 얻었다. 1. 노폐계(老廢鷄)의 생체중(生體重)은 WL종(種)이 1,635.40g, RIR종(種)이 2,289.29g이었고 도체율(屠體率)과 정육율(精肉率)은 WL종(種)에서 각각(各各) 58.73%와 43.95%였으며, RIR종(種)에서는 각각(各各) 60.34%와 41.98%였다. 2. WL종(種)과 RIR종(種)의 도체(屠體) 각(各) 부위(部位)의 구성비율(構成比率)은 경부(頸部) 4.13%와 3.94%, 익부(翼部) 9.97%와 8.62%, 흉부(胸部) 32.54%와 29.04%, 배부(背部) 11.35%와 9.75%, 대퇴부(大腿部) 30.75%와 31.34%, 피부(皮膚) 및 피하지방(皮下脂肪) 11.37%와 17.34%였다. 3. 정육(精肉)의 각(各) 부위별(部位別) 구성비율(構成比率)은 WL종(種)과 RIR종(種)에서 각각(各各) 경부(頸部) 4.03%와 3.95%, 익부(翼部) 9.47%와 9.79%, 흉부(胸部) 39.37%와 38.14%, 배부(背部) 11.24%와 9.40%, 대퇴부(大腿部) 36.16%와 38.74%였다. 4. 노폐계육(老廢鷄肉)의 화학적(化學的) 조성(組成)은 WL종(種)에서 수분(水分) 68.18%, 조단백질(粗蛋白質) 22.80%, 조지방(粗脂肪) 2.70%, 추출물(抽出物) 5.15%, 조회분(粗灰分) 1.18%였고, RIR종(種)에서는 수분(水分) 68.04%, 조단백질(粗蛋白質) 22.18%, 조지방(粗脂肪) 3.13%, 추출물(抽出物) 5.45%, 조회분(粗灰分) 1.21%였다. 5. 노폐계육(老廢鷄肉)을 $121^{\circ}C(1kg/cm^2)$에서 30분(分), 60분(分) 및 90분간(分間)을 증자(蒸煮)했을 때의 감율(減率)은 WL종(種)에서 각각(各各) 54.91%, 56.43% 및 58.42%였으며 RIR종(種)에서는 각각(各各) 45.23%, 47.68% 및 49.68%였다. 6. 노폐계(老廢鷄) 마리당(當) 건조계육제품(乾燥鷄肉製品)의 수량(收量)은 WL(種)에서 253.01g, RIR종(種)에서는 368.64g이었으며, 정육중(精肉重)과 도체중(屠體重)에 대(對)한 비율(比率)은 WL중종(種)에서 각각(各各) 35.47%와 26.34%였고, RIR종(種)에서는 각각(各各) 38.25%와 26.83%였다. 7. 건조육제품(乾燥肉製品)의 화학적(化學的) 조성(組成)은 WL종(種)에서 수분(水分) 16.69%, 조단백질(粗蛋白質) 66.16%, 조지방(粗脂肪) 12.81%, 조회분(粗灰分) 4.35%였고, RIR종(種)에서는 수분(水分) 16.11%, 조단백질(粗蛋白質) 65.95%, 조지방(粗脂肪) 13.78%, 조회분(粗灰分) 4.57%였다. 8. 제품(製品)의 품질(品質)을 결정(決定)하는 중요(重要)한 인자(因子)중의 하나인 물리적(物理的) 성질(性質)을 검토하기 위하여 인장강도(引張强度), 인열강도(引裂强度) 및 신장율(伸張率)을 측정(測定)하여 본 결과(結果) 압착(壓搾)조건을 $70kg/cm^2$로 하였을 때는 표준구(標準區)인 쥐포의 결착력(結着力)과 비교(比較)하여 노폐계육제품(老廢鷄肉製品)도 이와 유사(類似)하게 나타났다. 9. 각(各) 부위별(部位別) 제품(製品)의 색택측정(色澤測定)에서 명도(明度)는 압착(壓搾)조건이 $70kg/cm^2$인 제품(製品)이 $35kg/cm^2$인 제품(製品)보다 더 좋았으며 쥐포가 16.4%인 경우 가슴살의 $70kg/cm^2$ 조건에서의 제품(製品)은 16.7%로 유사(類似)하였고, Dominant wavelength도 이와 같은 경향이었으며 따라서 쥐포의 색택(色澤)과 아주 근사(近似)한 황갈색이었다. 10. 노폐계육(老廢鷄肉)의 부위(部位)에 따라 제조(製造)된 제품(製品)과 표준구(標準區)인 쥐포와의 맛, 색깔, 조직(組織) 및 냄새를 비교(比較)한 식미시험(食味試驗) 결과(結果)는 쥐포가 지수(指數) 100일 때 가슴살제품이 118.4로 쥐포보다 높았고 다음이 이보다 낮은 기타살 제품(製品)이 99.7, 다리살이 96.2 였다. 11. 이상(以上)의 결과(結果)를 종합적(綜合的)으로 검토(檢討)하여 볼 때 노폐계(老廢鷄)를 이용(利用)하여 제조(製造)된 육제품(肉製品)은 영양면(營養面)에서나 물성면(物性面)에서 이와 유사(類似)한 기존식품(旣存食品)에 결코 손색이 없는 고단백질식품(高蛋白質食品)으로서의 가치(價値)가 인정되었으며 따라서 공업화(工業化)의 타당성이 높다고 사료(思料)된다.

  • PDF

완도지역 성인 및 노인의 혈청지질 수준에 관한 연구(I) - 연령, 신체 계측치를 중심으로 - (A Study on Serum Lipid Levels in Elderly People in Wando Area - Based on Age, BMI, WHR -)

  • 차복경
    • 한국식품영양과학회지
    • /
    • 제35권1호
    • /
    • pp.68-77
    • /
    • 2006
  • 본 연구의 조사대상자는 전남 신안군 완도면 지역의 46세에서 83세사이의 남자 88명과 여자 99명 총 187명을 대상으로 한 연구결과를 요약하면 다음과 같다. 조사대상자의 남녀 평균 연령은 각각 65.14세, 64.92세 였고 평균 신장은 161.16cm, 151.64 crn, 평균 체중은 63.03 kg, 56.46 kg, 평균 BMI는 $24.33 kg/m^2,\;24.48 kg/m^2$, 평균 WHR은 0.94, 0.94였다. 조사 대상자 남녀 평균 총 섭취에너지는 1869.06 kcal, 1943.95 kcal로 남녀 모두 연령 증가에 따른 차이는 없었지만 남자는 60대까지는 증가하였고 70대 이후에 감소하였다. 여자는 60대가 가장 적게 섭취하는 것으로 조사되었다. 탄수화물 섭취량의 평균은 남녀 각각 368.26 g, 391.36 g로 유의적 차이는 없었으나 여자가 남자보다 많이 섭취하였고 연령증가에 따른 차이는 보이지는 않았다. 단백질 섭취량의 평균은 남녀 각각 28.08 g, 30.45 g으로 성별에 따른 차이는 없었고 연령이 증가함에 따라서 남녀 모두 증가하는 경향을 보였고 권장량에 비해 적게 섭취하는 것으로 조사되어 계절적인 요인도 관련이 있는 것으로 보이나 앞으로 이 지역에 대한 세밀한 연구가 필요할 것으로 생각된다. 지방 섭취량은 각각 31.57g, 28.51 g으로 성별과 연령에 따른 차이가 없는 것으로 조사되었다. Vit. A, Vit. $B_1$, Vit. $B_2$, Vit. D는 성별과 연령 증가와는 관련이 없는 것으로 조사되었다. Vit. C는 성별에 따른 차이는 없었고 연령이 증가함에 따라 남자는 유의적으로 감소하였고 여자는 유의성은 없지만 증가하는 경향을 보였다. Vit. E는 여자가 유의적으로 많이 섭취하였다. 엽산, 인, 철분 섭취는 남자가 유의적으로 많이 섭취하였으며 남자는 연령 증가에 따라 감소하는 경향을 보였으며 남녀 모두 한국인의 영양권장량을 상회하였다. 식사 중 콜레스테롤은 성별과 연령 증가에 따른 차이는 없었다. 조사대상자의 혈청 중성지방 농도의 남녀 각각 평균은 $149.53{\pm}8.22 mg/dL$, $143.83{\pm}5.07mg/dL$로 남녀간에 유의적인 차이는 없었으며, 남자의 경우 59세 이하, 60대, 70대 이상군에서 각각 129.6 mg/dL, 159.7 mg/dL, 157.4 mg/dL, 여자의 경우 각각 133.4 mg/dL, 149.4 mg/dL, 150.0 mg/dL로 59세 이하에서만 여자가 높고 다른 연령 군에서는 남자가 높았으며 연령증가와 함께 유의성은 없으나 증가하는 경향을 보였다. 혈청 총 콜레스테롤농도의 평균은 $189.53{\pm}4.73 mg/dL$, $157.93{\pm}4.96 mg/dL$이었고 남자가 유의적으로 높았다(p<0.05). 남녀 각각 59세 이하, 60대, 70대 이상군에서 185.0 mg/dL, 199.3 mg/dL, 180.9 mg/dL과 161.4 mg/dL, 180.9 mg/dL, 164.8 mg/dL였다. $40\~50$대는 남자가 유의적으로 높았으며 (p<0.05) 유의성은 없지만 남녀 모두 식사중의 콜레스테롤 섭취량이 가장 많은 것으로 조사된 60대의 혈청 총 콜레스테롤 농도가 가장 높은 것으로 나타나 식사중의 콜레스테롤이 혈청 총콜레스테롤에 영향을 미치는 것을 알 수 있었다. 혈청 LDL-콜레스테롤 농도의 평균은 $120.63{\pm}2.70 mg/dL$, $112.23{\pm}3.03 mg/dL$로 남녀 모두정상범위에 속하였으며 남자가 여자에 비해 유의적으로 높았고(p<0.05)남녀 각각 59세 이하, 60대, 70대 이상군에서 118.4 mg/dL, 118.8 mg/dL, 125.5 mg/dL과 108.6 mg/dL, 112.5 mg/dL, 112.9 mg/dL로 연령증가와 함께 증가하는 경향을 보였다. 혈청 HDL-콜레스테롤 농도의 평균은 $52.98{\pm}1.42 mg/dL$, $50.36{\pm}1.51 mg/dL$로 성별, 연령간에 유의적인 차이는 없었다. 심혈관 질환 예측 인자인 atherogenic index는 남녀 각각 평균 $2.13{\pm}0.08$, $2.49{\pm}0.11$로 여자가 유의적으로 높았고(p<0.05) 또한 여자는 유의성은 없지만 연령 증가와 함께 증가하는 경향을 보였고 $70\~80$대는 여자가 유의 적으로 높게 나타나(p<0.05) 여자는 연령증가와 함께 호르몬의 영향으로 심혈관계질환 위험성이 높은 것을 확인할 수 있었다. 공복시 혈당농도는 평균 $86.51{\pm}3.25 mg/dL$, $91.16{\pm}2.89 mg/dL$로 모두 정상 범위에 있었으며 $70\~80$대는 여자가 유의적으로 높게 나타났다(p<0.05). 본 연구에서는 2000년 International Obesity Task Force(IOTF)가 아시아인을 대상으로 제시한 기준에 따라 3단계(저체중 BMI<19, 정상체중 $19{\leq}BMI<25$, 과체중 $BMI\geq25$)로 분류한 결과 혈청 중성 지방은 남자 저체중군, 상체중군, 과체중군이 각각 114.1 mg/dL, 134.8 mg/dL, 176.5 mg/dL, 여자는 각각 106.7 mg/dL, 140.2 mg/dL, 157.1 mg/dL로 모든 연령 군에서 200 mg/dL보다는 낮았으나 과체중군이 다른 두 군에 비해 유의적으로 높은 것으로 조사되었다(p<0.05). 혈청 총콜레스테롤의 남녀 저체중군, 정상체중군, 과체중군이 각각 114.5mg/dL, 192.0 mg/dL, 203.4 mg/dL과 112.9 mg/dL, 156.7 mg/dL, 193.7 mg/dL로 BMI가 높을수록 두군 모두 유의적으로 증가하였다(p<0.05). LDL-Cholesterol은 남녀 저체중군, 정상체중군, 과체중군이 각각 104.6 mg/dL, 123.2 mg/dL, 120,8 mg/dL과 79.8 mg/dL, 105.9 mg/dL, 123.7 mg/dL로 BMI가 높을수록 유의적으로 높아졌다(p<0.05). 동맥경화지수는 남녀 각각 저체중군, 정상체중군과 과체중군이 2.48, 1.98, 2.23과 1.66, 2.22, 2.98로 저체중군에서는 남자가 높았으나 정상체중군과 과체중군에서는 여자가 높았고 BMI가 증가함에 따라 남자는 뚜렷한 경향을 보이지 않았으나 여자는 유의적으로 증가하여 (p<0.05) 동맥경화를 비롯한 심혈관계질환의 위험도가 여자가 높다는 것을 알 수 있었다. 혈당은 남자는 저체중군, 정상체중군과 과체중군이 각각 68.1 mg/dL, 96.0 mg/dL, 78.4 mg/dL로 정상체중일 때 다른 두 군에 비해 유의적으로 높았는데(p<0.05)여자는 87.5 mg/dL, 88.5 mg/dL, 94.8 mg/dL로 유의성은 없지만 BMI가 증가할수록 혈당이 높아졌다. 본 조사대상자의 연령을 보정한 후 WHR에 따른 혈청 지질 및 혈당 수준은 남자는 WHR이 높을수록 혈청 중성 지방과 혈당은 유의적으로 증가 하였고(p<0.05) 혈청 총 콜레스테롤, LDL-cholesterol, 동맥경화지수는 유의성은 없지만 증가하는 경향을 보였다. 여자는 WHR이 높을수록 혈중 중성지방, 혈당, 혈청 총 콜레스테롤, LDL-cholesterol, 동맥 경화지수가 유의적으로 높아졌다(p<0.05). HDL-Cholesterol은 WHR이 높을수록 남자는 유의성은 없지만 낮아지는 경향을 보였고 여자는 유의적으로 낮아졌다(p<0.05). 이상의 결과에서 연령, BMI, WHR이 높을수록 심혈관계 질환의 위험인자인 혈청 중성지방, 혈청 총콜레스테롤, LDL-cholesterol의 수준이 높아졌지만 혈청 지질의 평균이 대부분 한국인의 정상수준에 속하였고 비정상자의 비율도 다른 지역에 비해서 낮은 편으로 조사되어 앞으로 도서지역의 식생활과 만성질환 위험인자와의 관련성에 대한 지속적인 연구가 필요할 것으로 보인다.