• Title/Summary/Keyword: average discharge

Search Result 734, Processing Time 0.03 seconds

Synthesis of $LiCoO_2$ by solution route and its behaviour as a cathode material in lithium ion secondary battery (액상반응에 의해 합성한 $LiCoO_2$ 를 정극활물질로 이용한 Li ion 2차전지의 특성)

  • 김상필;조정수;박정후;심윤보;윤문수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.143-146
    • /
    • 1998
  • The $LiCoO_2$ powder was synthesized at >$700^{\circ}C$, >$850^{\circ}C$ by solution route. In this paper, we investigated X-ray diffraction, and charge-discharge performance for $LiCoO_2$/Li and $LiCoO_2$/MPCF cell. The $LiCoO_2$/Li ceSl exhibited a high avmge discharge potential of 38-3% and a good cycle life performance at 5(hnA/g during chargedischarge cycling between 43-3.0V. And, the $LiCoO_2$MPCF cell showed a high average discharge voltage of 3.6-3.W and a excellent cycle life prfomam during chargedischarge cycling b&wm 4 2-2.W. As a result, the $LiCoO_2$ powdm syd-eizd by solution route is a good cathode material for lithium ion secondary battery.

  • PDF

Application of Flux Average Discharge Equation to Assess the Submarine Fresh Groundwater Discharge in a Coastal Aquifer (연안 대수층의 해저 담지하수 유출량 산정을 위한 유량 평균 유출량 방정식의 적용)

  • Il Hwan Kim;Min-Gyu Kim;Il-Moon Chung;Gyo-Cheol Jeong;Sunwoo Chang
    • The Journal of Engineering Geology
    • /
    • v.33 no.1
    • /
    • pp.105-119
    • /
    • 2023
  • Water supply is decreasing due to climate change, and coastal and island regions are highly dependent on groundwater, reducing the amount of available water. For sustainable water supply in coastal and island regions, it is necessary to accurately diagnose the current condition and efficiently distribute and manage water. For a precise analysis of the groundwater flow in the coastal island region, submarine fresh groundwater discharge was calculated for the Seongsan basin in the eastern part of Jeju Island. Two methods were used to estimate the thickness of the fresh groundwater. One method employed vertical interpolation of measured electrical conductivity in a multi depth monitoring well; the other used theoretical Ghyben-Herzberg ratio. The value using the Ghyben-Herzberg ratio makes it impossible to accurately estimate the changing salt-saltwater interface, and the value analyzed by electrical conductivity can represent the current state of the freshwater-saltwater interface. Observed parameter was distributed on a virtual grid. The average of submarine fresh groundwater discharge fluxes for the virtual grid was determined as the watershed's representative flux. The submarine fresh groundwater discharge and flux distribution by year were also calculated at the basin scale. The method using electrical conductivity estimated the submarine fresh groundwater discharge from 2018 to 2020 to be 6.27 × 106 m3/year; the method using the Ghyben-Herzberg ratio estimated a discharge of 10.87 × 106 m3/year. The results presented in this study can be used as basis data for policies that determine sustainable water supply by using precise water budget analysis in coastal and island areas.

Annual Changes in the Distribution of Bolboschoenus planiculmis in the Eulsuk-Island, Nakdong River Estuary (낙동강하구 을숙도 새섬매자기(Bolboschoenus planiculmis) 군락 변화 연구)

  • Hee Sun Park;Gea-Jae Joo;Wonho Lee;Ji Yoon Kim;Gu-Yeon Kim
    • Korean Journal of Ecology and Environment
    • /
    • v.56 no.3
    • /
    • pp.259-267
    • /
    • 2023
  • This study analyzed the relationship between distribution of Bolboschoenus planiculmis which is main food source of swans (national monument species) with environmental factors, discharge, rainfall, and salinity in Eulsuk-do from 2020 to 2023. The distribution area of B. planiculmis in Eulsuk tidal flat was 103,672m2 in 2020, 95,240 m2 in 2021, 88,163 m2 in 2022, and 110,879 m2 in 2023, and represents a sharp decrease compared to the 400,925 m2 area recorded in 2004. From 2020 to 2023, the growth densities of B. planiculmis were 243.6±12.5 m-2, 135.45±7.38 m-2, 51.10±2.54 m-2, and 238.20±16.36 m-2, respectively, and the biomass was 199.89±28.01 gDW m-2, 18.57±5.12 gDW m-2, 6.55±1.12 gDW m-2, and 153.53±25.43 gDW m-2 in 2020, 2023, 2021, and 2022, respectively. Based on discharge during May~July, which affects plant growth, the left gate discharge of the estuary barrage from 2020 to 2023 was 62,322 m3 sec-1, 33,329 m3 sec-1, 6,810 m3 sec-1, and 93,641 m3 sec-1, respectively; rainfall was 1,136 mm, 799 mm, 297 mm, and 993 mm, respectively; and average salinity was 14.7±9.4 psu, 21.1±4.7 psu, 26.1±2.7 psu, and 14.5±11.1 psu, respectively. In 2022, cumulative rainfall (978 mm, about 70% of the 30-year average) and discharge (43,226 m3 sec-1) decreased sharply, resulting in the highest mean salinity (25.46 psu), and the distribution area, density, and biomass of the B. planiculmis decreased sharply. In 2023, there was a rise in discharge with an increase in rainfall, leading to a decrease in salinity. Consequently, this environmental change facilitated the recovery of B. planiculmis growth.

Characteristics of Pollutant Loading from Paddy Field Area with Groundwater Irrigation (지하수 관개지역 논에서의 배출부하 특성)

  • 윤춘경;김병희;전지홍;황하선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.5
    • /
    • pp.116-126
    • /
    • 2002
  • Discharge pattern and water quality were investigated in the drainage water from about 10 ha of groundwater-irrigated paddy field in the growing season of 2001. Total discharge quantity was about 1,117.2 mm in which about 75% was caused by management drainage due to cultural practice of paddy rice farming and the rest by rainfall runoff where total rainfall was about 515 mm. Dry-day sampling data showed wide variations in constituent concentrations with average of 26.14 mg/L, 0.37 mg/L, 3.54 mg/L at the inlet, and 43.60 mg/L, 0.34 mg/L, 3.58 mg/L at the outlet for CO $D_{cr}$ , T-P, and T-N, respectively. Wet-day sampling data demonstrated that generally CO $D_{cr}$ followed the discharge pattern and T-P was in opposite to the discharge pattern, but T-N did not show apparent pattern to the discharge. Discharge and load are in strong relationship. And based on regression equation, pollutant loads from groundwater irrigation area are estimated to be 288.34, 1.17, and 5.45 kg/ha for CO $D_{cr}$ , T-P, and T-N, respectively, which was relatively lower than the literature value from surface water irrigation area which implies that groundwater irrigation area might use less irrigation water and result in less drainage water, Therefore, total pollutant load from paddies irrigation with groundwater could be significantly lower than that with surface water. This study shows that agricultural drainage water management needs a good care of drainage outlet as well as rainfall runoff. This study was based on limited monitoring data of one year, and further monitoring and successive analysis are recommended for more generalized conclusion.

The estimation of river discharge by using the mean velocity equation in a unsteady condition (평균유속공식을 이용한 부정류 하천유량 산정)

  • Choo, Tai Ho;Chae, Soo Kwon;Yoon, Hyeon Cheol;Yun, Gwan Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6558-6564
    • /
    • 2013
  • As the average indicator for amount of water flowing in any cross section of a river, the mean discharge has been reported to be a very important factor for examining water circle constructions in a river basin, the design and construction of a hydraulic structure, and water front area use and management. The stage-discharge curve based on discharge and stage data measured in a normal season were basically derived. Using this derivation, the necessary discharge data was obtained. The values produced in this manner corresponded to the measured data in a uniform flow state well, but showed limited accuracy in a flood season (unsteady flow). In the present paper, the mean velocity in unsteady flow conditions, which exhibited loop form properties, was estimated using the new mean velocity formula derived from Chiu's 2-D velocity. The results of RMSE and Polar graph analyses showed that the proposed equation exhibited approximately nineteen times the accuracy compared to the Manning and Chezy equations.

Outcomes of Home Care Service for Coronary Artery Bypass Graft (관상동맥우회술 환자의 가정간호 효과)

  • Baek, Hee-Chong
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.10 no.2
    • /
    • pp.123-131
    • /
    • 2003
  • This study was to compare the functional status. complication and readmission rates. and client satisfaction with nursing care of home-based care and hospital-based care for clients with Coronary Artery Bypass Graft. Raw data were collected by interviewing and reviewing charts of 41 clients with Coronary Artery Bypass Graft between June 2001 and July 2002 at an university hospital located in Seoul. Korea. Out of 41 clients. 15 were in home care group and 26 were in hospitalization group. The baseline characteristics of the groups were almost identical. Mean age was 61.7 and 75.6% of clients being male. For home care group. the data collection was made at discharge and at termination of home care. and for hospitalization group. at discharge and at the first visit of outpatient department. Complication and readmission rates were investigated at one month after operation. Collected data were then analysed by conducting Chi-square test. Wilcoxon rank sum test. and Wilcoxon signed ranks test with SPSS program. The level of significance was .05. The results of the study are summarized as follows: 1. Postoperative length of stay of the home care group was shorter than that of hospitalization group by 1. 14 days(8.45 days vs. 9.59 days). On average. 1.8 home visits per client were observed. 2. The functional status (Barthel Index) at the termination of home care was significantly increased from that at discharge. For hospitalization group. a significant increase was observed between the functional status at the discharge and that at the first visit of outpatient department. The differencies in incremental of the scores. between the groups. were however not significant. 3. Complication and readmission rates; no statistically significant difference between the groups was observed. 4. The client satisfaction with nursing care (CSS) at termination of home care was significantly higher than that at hospital discharge. In conclusion. the outcomes of the analysis suggest that the home care benefits clients with Coronary Artery Bypass Graft. Client satisfaction with nursing care rises at termination of home care as compare to that measured at hospital discharge. Meanwhile. there was no significant differences in functional status. and complication and readmission rates. Further. home care reduced the length of stay in hospital.

  • PDF

Effects of Thermal Effluents from Wolseong Nuclear Power Plant on Macroalgal Composition and Community Structure (월성원자력발전소 온배수가 해조류 종조성 및 군집구조에 미치는 영향)

  • Choi, Han-Gil
    • ALGAE
    • /
    • v.23 no.2
    • /
    • pp.151-162
    • /
    • 2008
  • Marine algal flora and community structure were seasonally examined at three sites in the vicinity of the Wolseong nuclear power plant in Korea from February to November 2006. A total of 126 seaweeds including 25 green, 31 brown, 70 red algae, and 1 marine plant were identified. The greatest number of species occurred at Jeonchonri (101 species) followed by intake (88 species) and discharge (29 species) during the study period. Of 126 seaweeds, 76 annuals and 13 warm tolerance species were recorded. Dominant species based on important value (IV > 10) were Ulva pertusa and Enteromorpha linza at intake, U. pertusa and Padina arborescens at discharge, and Sargassum horneri and Corallina pilulifera at Jeonchonri shore. Annual average biomass exhibited a wide range of variations, from 40.67g m-2 in dry weight at discharge to 133.69g m-2 at Jeonchonri. Among six functional groups, dominant group was coarsely-branched form at intake and Jeonchonri, but it was different at discharge site as filamentous form. Seaweed community structures of discharge site were distinguishable in decreasing species richness, biomass, species diversity index (H’), richness index (R), and evenness index (J’). Also, the ratios of green algae, warm tolerance species, annual algae, filamentous form and dominance index (DI) remarkably increased. Such phenomenons of discharge site are usually found under environmentally stressful conditions such as high disturbance. Thus, I can conclude that the heated effluents of nuclear power plant act as environmental stress influencing seaweed community structures and it can be detected with various community indices.

The Effect of Discharge Loading at Sewage Treatment Plants on Water Quality in Kyoungan Stream (경안천 수질에 대한 환경기초시설 방류부하량의 영향)

  • Kim, Ho-Sub;Lee, Su-Woong;Rhew, Doug-Hee;Kong, Dong-Soo
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.3
    • /
    • pp.452-458
    • /
    • 2009
  • This study was carried out to assess the effect of discharge loading at sewage treatment plants (STP) on water quality in Kyoungan stream. The seasonal variations of water quality (BOD, COD, SS, TN, and chl.a) at site 1(Mesanribo) were similar with those at site 2(Sehabo). BOD, COD, SS, and chl.a concentration were also similar except for TN and TP concentration which were lower than those at site 1. The BOD, COD, TN, TP and chl.a concentration at site 2 in dry period were higher than that of wet period. The ratios of BOD, TP, COD, SS discharge loading at all STP in Kyoungan stream watershed to delivery loading at site 2 were 0.69, 0.54, 0.48, 0.31, and 0.26 on average, respectively. Both site 1 and site 2, the seasonal variations of discharge loading at STP did not showed any relationship with those of water quality. The mean ratios of inflow loading at site 1 to delivery loading at site 2 were relatively high that ranged from 0.43 to 0.61. In dry period, the ratios of discharge loading at STP in Sehabo watershed to delivery loading at site 2 were below 0.2 except for BOD (0.24), and decreased <0.1 in wet period. While, SS loading from watershed between site 1 and site 2 to delivery loading at site 2 ratios increased in wet period.

Efficacy of mid-upper arm circumference in identification, follow-up and discharge of malnourished children during nutrition rehabilitation

  • Mogendi, Joseph Birundu;De Steur, Hans;Gellynck, Xavier;Saeed, Hibbah Araba;Makokha, Anselimo
    • Nutrition Research and Practice
    • /
    • v.9 no.3
    • /
    • pp.268-277
    • /
    • 2015
  • BACKGROUND/OBJECTIVES: Although it is crucial to identify those children likely to be treated in an appropriate nutrition rehabilitation programme and discharge them at the appropriate time, there is no golden standard for such identification. The current study examined the appropriateness of using Mid-Upper Arm Circumference for the identification, follow-up and discharge of malnourished children. We also assessed its discrepancy with the Weight-for-Height based diagnosis, the rate of recovery, and the discharge criteria of the children during nutrition rehabilitation. SUBJECTS/METHODS: The study present findings from 156 children (aged 6-59 months) attending a supplementary feeding programme at Makadara and Jericho Health Centres, Eastern District of Nairobi, Kenya. Records of age, weight, height and mid-upper arm circumference were selected at three stages of nutrition rehabilitation: admission, follow-up and discharge. The values obtained were then used to calculate z-scores as defined by WHO Anthro while estimating different diagnostic indices. RESULTS: Mid-upper arm circumference single cut-off (< 12.5 cm) was found to exhibit high values of sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio at both admission and discharge. Besides, children recorded higher rate of recovery at 86 days, an average increment of 0.98 cm at the rate of 0.14mm/day, and a weight gain of 13.49gm/day, albeit higher in female than their male counterparts. Nevertheless, children admitted on basis of low MUAC had a significantly higher MUAC gain than WH at 0.19mm/day and 0.13mm/day respectively. CONCLUSIONS: Mid-upper arm circumference can be an appropriate tool for identifying malnourished children for admission to nutrition rehabilitation programs. Our results confirm the appropriateness of this tool for monitoring recovery trends and discharging the children thereafter. In principle the tool has potential to minimize nutrition rehabilitation costs, particularly in community therapeutic centres in developing countries.

Performance of the RI Exhaust Filter at Chosun University Cyclotron Facility and 18F Emission Reduction (조선대학교 사이클로트론 시설의 RI 배기필터 성능평가 및 18F 배출저감 연구)

  • Jeong, Cheol-Ki;Jang, Han;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • Recently, the number of PET cyclotrons has increased in Korea. A cyclotron mainly produces $^{18}F$, which is used for the production of [$^{18}F$]FDG, a cancer diagnostic radiopharmaceutical. For radiation protection, the discharge control standard under the Nuclear Safety Act limits the radioactive concentration of $^{18}F$ in the exhaust discharged from a nuclear power utilization facility to below $2,000Bq\;m^{-3}$. However, the radioactive concentration of $^{18}F$ discharged during [$^{18}F$]FDG production at the cyclotron facility at Chosun University is maintained at about $1,500Bq\;m^{-3}$ on average, which is 75% of the concentration limit of the discharge control standard, and temporarily exceeds the standard as per the real-time monitoring results. This study evaluated the performance of the exhaust filter unit of the cyclotron facility at Chosun University by assessing the concentration of $^{18}F$ in the exhaust, and an experiment was conducted on the discharge reduction, where $^{18}F$ is discharged without reacting with the FDG precursors during [$^{18}F$]FDG synthesis and is immediately captured by the [$^{18}F$]FDG automatic synthesis unit. Based on the performance evaluation results of the exhaust filter at the cyclotron facility of Chosun University, the measured capture efficiency before and after the filter was found to be 92%. Furthermore, the results of the discharge reduction experiment, where the exhaust $^{18}F$ was immediately captured by the [$^{18}F$]FDG synthesizer, showed a very satisfactory 94.3% reduction in the concentration of discharge compared to the existing discharge concentration.