• 제목/요약/키워드: autoclave test

검색결과 113건 처리시간 0.029초

급성폐혈증형 돼지단독예에서 분리한 Erysipelothrix rhusiopathiae의 혈청형 및 병원성 (Serotype and pathogenicity of Erysipelothrix rhusiopathiae isolated from the cases of acute septicemic swine erysipelas)

  • 백영숙;김봉환
    • 대한수의학회지
    • /
    • 제31권1호
    • /
    • pp.63-69
    • /
    • 1991
  • The serotypes and pathogenicity of 47 isolates of Erysipelothrix rhusiopathiae from pigs with acute septicemic swine erysipelas were investigated. The serotypes were determiend by agar gel precipitation test using autoclave extracted antigens. All of the 47 isolates(42 strains from Youngnam and fi fotrains from Kyunggi province) were serotype lao Five field isolates of Erhusiopathiae serovar la were tested for pathogenicity in mice. All of 5 selected isolates were pathogenic for mice and $LD_{50}$ was $3.7{\times}10^3$ viable cells. Mice immunized subcutaneously with live vaccine did not die after challenge with virulent isolates of E rhusiopathiae.

  • PDF

전자석 구조물용 적층 유리섬유강화 복합재료의 기계적 특성 (Mechanical Properties of the Laminated Glass Fiber-Reinforced Plastic Composites for Electromagnet Structure System)

  • 박한주;김학근;송준희
    • 대한금속재료학회지
    • /
    • 제49권8호
    • /
    • pp.589-595
    • /
    • 2011
  • Laminated glass fiber-reinforced plastic (GFRP) composites were applied to an insulating structure of a magnet system for a nuclear fusion device. Decreased inter-laminar strength by a strong repulsive force between coils which is induced a problem of structural integrity in laminated GFRPs. Therefore, it is important to investigate the inter-laminar characteristics of laminated GFRP composites in order to assure more reliable design and better structural integrity. Three types of the laminated GFRP composites using a high voltage insulating materials were fabricated according to each molding process. To evaluate the grade of the fabricated composites, mechanical tests, such as hardness, tensile and compressive tests,were carried out. The autoclave molding composites satisfied almost of the mechanical properties reguested at the G10 class standard, but the vacuum impregnation (VPI) and Prepreg composites did not.

테이프래핑 구조물의 구조 해석 및 파단 예측 (Structural Analysis and Failure Prediction of Tape-Wrapped Structures)

  • 구남서;박훈철;윤광준;이열화
    • 한국항공우주학회지
    • /
    • 제32권3호
    • /
    • pp.17-21
    • /
    • 2004
  • 테이프래핑 구조물은 유도무기의 노즐 구조에 많이 사용되고 있는데 주로 주자직 복합재료를 띠모양으로 이은 다음 이를 맨드럴에 경사각을 가지게 감는 방법으로 제작된다. 적층된 구조물은 고압의 오토클레이브나 하이드로 클레이브에서 성형된다. 테이프래핑 구조물은 적층 형태가 일방향 복합재료의 경우와는 다르며, 제작 시 주어진 경사각을 고려한 해석이 필요하다. 본 연구에서는 테이프래핑 구조물에 대한 해석 기법을 고찰하였다. 먼저 4점 굽힘 실험에 대한 유한요소 해석 결과와 실험 결과를 비교함으로써 테이프래핑 구조물의 모델링 기법의 타당성을 검증하였다. 4점 굽힘 실험의 파단 하중과 이방성 파단 판정식의 결과를 비교함으로써 최적의 이방성 파단 판정식을 확인하였다.

편향각과 전단각이 탄소섬유/에폭시 평직 복합재료의 압축특성에 미치는 영향 (The Effect of Bias and Shear Angles on Compressive Characteristics of Carbon/Epoxy Plain Weave Fabrics)

  • 김성집;장승환
    • 대한기계학회논문집A
    • /
    • 제30권7호
    • /
    • pp.857-864
    • /
    • 2006
  • Various compressive specimens were fabricated using autoclave do-gassing moulding to find out the compressive characteristics of the carbon/epoxy plain weave fabric composites with respect to the bias and shear angles. The stacking angles of the bias specimens are $[0]_{10T,}\;[3]_{10T,}\;[6]_{10T,}\;[9]_{10T,}\;[12]_{10T,}\;[15]_{10T,}\;[30]_{10T,}\;[45]_{10T}$ and those of the sheared specimens are $[{\pm}37]_{10T,}\;[{\pm}32]_{10T,}\;[{\pm}28]_{10T,}\;[{\pm}22]_{10T,}$ respectively. In order to verify the effect of micro-tow structures on compressive strength and modulus of the composites, compressive test specimens of uni-directional carbon/epoxy composites with the same materials and the same stacking conditions were fabricated. The modulus and strength of both types of composite specimens were compared with the prediction results based on the CLPT and a proposed strength formula. The tow deformation and fracture modes were investigated by microscopic observation.

PWR환경에서 CF8M, CF8A 배관재의 부식피로특성 연구 (Corrosion Fatigue Characteristics of CF8M and CF8A on the PWR Condition)

  • 정일석;이용성;김상재;송택호;조선영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1062-1067
    • /
    • 2003
  • In this study, corrosion fatigue characteristics of CF8M and CF8A steel were investigated on the simulated PWR condition(Temp.:$316^{\circ}C$, Pres.: 15:MPa). To make the simulated PWR condition. the special test machine consisted of INSTRON, Autoclave, LOOP and Measurement system was developed. As ${\Delta}K$ is ranged from 11 to $20MPa{\sqrt{m}}$, Crack growth rate of PWR condition is faster than air condition. Above $20MPa{\sqrt{m}}$, the crack growth rate of PWR and air condition is similar. Corrosion fatigue characteristics regardless of the ferrite contents($10{\sim}25wt.%$) is not different. After the test, the fracture surface of specimens was examined. It was difficult to verify the fracture modes such as striation, intergranular crack and cleavage and so on. As the ferrite content of CF8M is increased, the more particles covered fracture surface were peeled.

  • PDF

해수 열화 및 원공 손상 CF/Aramid 복합재의 패치 부착이 굽힘거동에 미치는 영향 (The Patch Attachment Effect for Bending Behavior on the CF/Aramid Composites with Seawater Aging and Hole Damage)

  • 권우덕;권오헌;윤유성
    • 한국안전학회지
    • /
    • 제38권3호
    • /
    • pp.20-26
    • /
    • 2023
  • Fiber-reinforced composite materials with carbon, glass, and aramid fibers are widely applied to industrial field structures due to their excellent properties. However, carbon fibers are vulnerable to external impacts, whereas aramid fibers degrade when exposed to water. This study evaluated carbon/aramid fiber composites degraded and damaged by high-temperature saline environments using acoustic emission (AE). The test specimen was molded using an autoclave and immersed in seawater at 70 ℃ for 224 days. In order to imitate the damage, a 3-mm-diameter hole was drilled using a diamond drill. Additionally, the specimen with the perforation was repaired by patch attachment processing. Three-point bending was used to conduct the flexural experiment, and an AE sensor with a 150-kHz resonance frequency was attached to evaluate the damage and the effect of patch attachment. AE accumulative counts obtained at the maximum load were 69.2, 67.1, and 91.2 for a high-temperature seawater deteriorated condition, a hole specimen, and a repaired patch specimen, respectively. Furthermore, the maximum amplitude of AE was detected at low values of 28 dB, 31.3 dB, and 30.3 dB.

열멸균과정이 nickel titanium호선의 기계적 성질과 표면상태에 미치는 영향 (The Effect of Heat Sterilization on the Surface Topography and the Tensile Properties in Various Nickel Titanium Wires Including a Korean Product)

  • 김병호;남동석;양원식
    • 대한치과교정학회지
    • /
    • 제28권6호
    • /
    • pp.927-935
    • /
    • 1998
  • 본 연구의 목적은 수종의 nickel titanium 호선을 열멸균 처리 하였을 때 나타나는 물리적성질과 표면상태의 변화를 정량적으로 평가하고자 하는 것이다. 연구에 사용된 재료는 국산제품을 포함한 4종의 .$016\times.22$ 각형 nickel-titanium호선이며, 이들을 건열소독($180^{\circ}C$, 60분)군과 가압증기멸균($121^{\circ}C$, 15-20 psi, 30분)군, 그리고 아무런 처리를 하지 않은 대조군으로 구분하였다. 인정특성은 Inston (Model 4466, load cell capacity:1000kg)을 이용하여 표점거리 40mm, cross head는 분당 5mm의 속도, 실온의 조건에서 평가하였으며 쳐대인장강도와 연신율, 그리고 탄성률을 측정 및 계산하였다. 표면상태는 주사전자현미경과 profilometer로써 평가하였고, 1-test를 이용하여 통계적 분석을 하였다. 결과는 다음과 같다. 1. 실험에 사용된 nickel-titanium호선들은 모두 두가지 열멸균 처리에 의해 인장특성에 있어서 유의할 만한 변화를 보이지 않았다/ 2. 대조군에서 NiTi가 가장 높은 펴ㅛ면거칠기를 보였고, Align과 Sentalloy는 동일한 정도의 값을, Optimalloy는 가장 낮은 값을 지니고 있었다. 3. Align과 Optimalloy는 두가지 열멸균처리 후에 모두 유의할 만한 표면상태의 변화를 보이지 않았다. 그러나 NiTi는 건열소독후에 표면거칠기의 증가를 보였으며 Sentalloy는 두가지 열멸균후에 표면상태의 변화와 표면거칠기의 유위한 증가를 보였다.

  • PDF

탄소섬유 및 탄소복합재의 물리적/기계적 특성에 대한 고온열처리의 영향 연구 (A Study on the Effents of High Temperature Heat Treatment on the Physical and Mechanical Properities of Carbon Fiber and Carbon Composites)

  • 김동규;하헌승;박인서;임연수;윤병일
    • 한국재료학회지
    • /
    • 제4권3호
    • /
    • pp.287-294
    • /
    • 1994
  • PAN계 탄소섬유 roving 및 fabric을 $2170^{\circ}C$에서 열처리 하였다. 열처리를 행하지 않은 탄소섬유 fabric과 행한 것을 사용하고, Autoclave를 이용하여, CFRP와 CFRP의 성형체를 제조하였다. 열처리를 행한 탄소섬유 roving과 행하지 않은것 및 두종류의 성형체의 분석을 통하여, 열처리에 따른 탄소섬유 및 탄소복합재의 물리적. 기계적 특성변화를 연구하였다. 열처리 후 성유의 단면을 주사전자현미경으로 관찰한 결과 탄소섬유의 직경이 6.8$\mu \textrm{m}$에서 6.4$\mu \textrm{m}$으로 감소하였으며, 열중량분석을 행한 결과 내산화성이 증진되었음을 알았다. 단섬유인장실험 결과 인장강도는 탄소섬유의 (3.11$\pm 0.32)\times 10^3$ MPa 에서 열처리 섬유의 (1.87$\pm 0.26)\times 10^3$MPa으로 감소되었으나, 탄성율은 탄소섬유의 (1.94$\pm 0.06)\times 10^5$ MPa에서 열처리 섬유의 (2.02$\pm 0.11)\times 10^5$MPa으로 증가하였다. 층간전단강도 측정 실험을 한 결과 그 값이 CFRP(148.8$\pm$1.6Mpa)가 CFRP(82.2$\pm$1.1Mpa)에 비하여 높음을 알 수 있었고, torch test 결과 CFRP는 층간분리 없이 매끄러운 삭마가 일어나나, GFRP는 층간분리가 발생함을 알 수 있었다.

  • PDF

차아염소산나트륨 처리와 멸균법이 근관 치료용 파일의 부식에 미치는 영향에 관한 연구 (THE EFFECT OF NAOCL TREATMENT AND STERILIZATION PROCEDURES ON THE CORROSION OF ENDODONTIC FILES)

  • 양원경;라윤식;이영규;손호현;김미리
    • Restorative Dentistry and Endodontics
    • /
    • 제30권2호
    • /
    • pp.121-127
    • /
    • 2005
  • 근관 치료시 많이 사용되고 있는 $K-flex^{(R)}$ S-S 파일 (Maillefer, USA)과 $Profile^{(R)}$ Ni-Ti 파일 (Maillefer, USA), $K-3^{(R)}$ Ni-Ti파일 (SybronEndo, USA)의 부식 정도를 보기 위하여 총 360개의 20번 file을 1) 멸균소독 방법 (고압가열멸균소독, E-O gas 소독) ,2) 근관세척 액 ($5,25\%$ 차아염소산나트륨, 생리식염수) ,3) 멸균소독 횟수 (1, 5, 10회 ) 에 따라 36개 실험군으로 나누었다. 각각의 파일을 각 군별로 처리한 뒤, 세 명의 검사자가 광학 현미경 하에서 25배의 배율로 검사하여 0; 부식 없음, 1; 경도의 부식, 2; 중등도의 부식, 3; 심한 부식으로 점수화 하였다. 심한 부식을 보이는 파일의 표면은 SEM으로 관찰하였고 Kruskal-Wallis test (p < 0.05)를 이용하여 통계 분석 처리하여 차아염소산나트륨 접촉 여부와 멸균소독 방법의 차이에 의한 부식 정도를 평가하였다. 그 결과 고압가열멸균소독을 10회 시행한 파일은 통계적으로 유의한 차이를 보여 부식 정도가 심하였고, 1회나 5회 고압가열멸균소독을 시행한 파일과 E-O 가스로 소독한 파일들은 부식의 정도가 경미하여 통계적으로 유의하지 않았다. 차아염소산나트륨 접촉 여부와 제조사 혹은 파일 재료에 따른 유의성 있는 차이는 없었다

RFI 공정시 적정 수지필름 두께에 관한 연구 (A Study on the Proper Resin Film Thickness in RFI Process)

  • 윤성현;이정완;김정수;김위대;엄문광
    • Composites Research
    • /
    • 제31권1호
    • /
    • pp.23-29
    • /
    • 2018
  • RFI 공정은 수지 점도에 제한이 없어 매우 두꺼운 구조물에도 적용이 가능하다. 수지필름 두께를 설정할 때 수지필름의 두께가 얇은 경우 미함침 구간이 발생하여 기계적 물성이 저하되고, 수지필름 두께가 두꺼운 경우 필요이상의 여분 수지가 발생하게 된다. 따라서 본 연구에서는 RFI 공정에서 수지필름 두께 설정을 위한 방법을 제시하였다. 적정 수지필름 두께를 설정하는 방법으로 섬유압착거동 시험을 제시하였고, 제시된 방법의 검증을 위해 숏빔전단강도시험, 압축시험, 기공률 측정을 통해 복합재 물성을 평가하였다. 복합재 물성 평가 결과, 섬유압착거동시험 결과를 바탕으로 적정 수준의 수지필름 두께를 찾을 수 있었다.