• Title/Summary/Keyword: atrial

Search Result 1,156, Processing Time 0.029 seconds

The Effects of Acupuncture by Needle Manipulation at $LR1{\cdot}KI1$ on the Blood Pressure in Hypertensive Rat induced by Two Kidney One Clip (2K1C). (대돈(大敦)${\cdot}$용천(湧泉) 염전(捻轉) 및 영수(迎隨) 보사수기법(補瀉手技法)이 2K1C에 의하여 유발(誘發)된 고혈압(高血壓) 백서(白鼠)에 미치는 영향(影響))

  • Youn, Dae-Hwan;Han, Jeong-Hee;Kim, Suhn-Hee;Na, Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.24 no.3
    • /
    • pp.165-177
    • /
    • 2007
  • Objectives : The purpose of this study was to examine effects of acupuncture by needle manipulation at $LR1{\cdot}Kl1$ on the blood pressure, plasma levels of ANP(atrial natriuretic peptide), renin and cardiomegalic index in hypertensive rat Induced by two kidney one clip(2K1C). Material and methods : The groups divided into 7 groups; Control, no treatment. Acu-1,acupuncture at $LR1{\cdot}Kl1$ bilaterally and the needle was twirled and rotated forward with the thumb of the right hand 6 times. Acu-2, acupuncture at $LR1{\cdot}Kl1$ bilaterally and the needle was twirled and rotated forward with the forefinger of the right hand 6 times. Acu-3, acupuncture at $LR1{\cdot}Kl1$ bilaterally and the needle was inserted in the opposite direction(body direction) as the channel runs, Acu-4, acupuncture at $LR1{\cdot}Kl1$ bilaterally, the needle was inserted in the opposite direction(body direction) as the channel runs and the needle was twirled and rotated forward with the forefinger of the right hand 6 times. The acupuncture executed 5times for 2 weeks. Results : Systolic blood pressure was decreased significantly in Acu-2, Acu-3 and Acu-4. Plasma renin was decreased significantly in Acu-2 and Acu-4. Plasma ANP was increased significantly in Acu-2, however was decreased significantly in Acu-4. Cardiac hypertrophy index was decreased significantly in Acu-1, Acu-2, Acu-3 and Acu-4. Conclusions : These results suggest that acupuncture by needle manipulation at $LR1{\cdot}Kl1$ is effective in hypertension by renal blood problem.

  • PDF

Microstructure of Spider Booklung as Bio-indicator for Monitoring Environmental Asbestos Exposure (거미 서폐의 미세구조와 석면노출 환경의 모니터링을 위한 생물지표적 유용성 평가에 관한 연구)

  • Kim, Chang-Mo;Moon, Myung-Jin
    • Korean Journal of Environmental Biology
    • /
    • v.32 no.1
    • /
    • pp.49-57
    • /
    • 2014
  • Orb-web spiders can be considered as an effective bio-indicative animal to monitor the ecological air pollution of certain habitat since they have limited shifting ability during their life spans. In this study we revealed the fine structural characteristics of booklung in the orb-web spider Nephila clavata, and its bio-indicative significance in the monitoring environmental asbestos exposure. The high resolution scanning electron microscopy results suggest that the cuticular spikes near the atrium could be act as an effective filtering structure for dust materials. Furthermore, inner cuticular spikes which protruded across the air sacs, have the functions not only sustaining appropriate respiratory volume of each air sac but also help to enhance respiratory capacity by maximizing the gross surface area for gas exchange. Interestingly, in spite of short exposure, the asbestose fibrils were effectively captured on the surface of the atrial cuticular spikes. Furthermore, histologic damages were observed due to penetration of asbestos fibrils through air sacs and fixed on the hemolymph space. In addition, although accumulated mass of hemocytes were observed near the fibrils, there were no asbestos bodies or coagulated hemocytes were found on the surface of the fibrils, This could be mainly due to the short exposure period towards asbestos. Briefly, these results indicate the spider's booklung could be valuable tool in the detection ecological air pollutants.

Development of a Korean Type Totally Implantable TAH (한국형 완전이식 인공심장의 개발)

  • Min, B.G.;Choi, W.W.;Ahn, J.M.;Park, S.K.;Park, C.Y.;Chang, J.K.;Kim, J.W.;Kim, H.C.;Kim, W.K.;Roh, R.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.199-202
    • /
    • 1996
  • Artificial hearts are intended for use in patients with severe forms of heart disease for which no surgical repair is possible. The moving-actuator pump was developed to decrease the overall volume size of the electromechanical total artificial heart (TAH) by eliminating the occupied space of the fixed-actuator in the conventional pusher-plate type pump. In our pump, the actuator moves back and forth for alternative ejections of left and right ventricles. The problem of fitting the TAH to atrial remnants and arterial vessels could also be improved by circular or penduluous mot ion of the actuator instead of linear mot ion of the pusher-plate in the conventional pumps. We have evaluated two types of moving- actuator pump; one is a rolling cylinder type, and the other a pendulum type pump. In the rolling cylinder pump, frictional energy loss exists between the pump housing's guide bars and the actuator's end caps, while the bottom rack under the cylindrical actuator increases the height of the pump, the pump is therefor not implantable inside the small chest of human-sized animals with a body weight of less than 70kg. The new human type pump has a penduluous mot ion actuator to correct the above problems while maintaining the advantage of the moving- actuator's small total volume. The totally implantable TAH is composed of a blood pump, a control system and pheriperal equipments. The blood pump, which is constructed by a moving actuator, a right and left blood sac, and four artificial valves, is implanted in the thoracic. In 1988, the first implantation of the rolling cylinder TAH was performed into a female calf weighing 100kg, and the cal f recovered to the degree of voluntary standing and eat ing and survived to 100 hrs. We then survived two female sheep weighing about 63kg with the new human type TAH for three days.

  • PDF

Respiratory Assist by Use of Electrical Diaphragmatic Pacing (전기자극에 의한 횡격막 조율을 이용한 호흡보조장치)

  • 오중환;김은기;서재정;박일환;김부연;이상헌;이종국;이영희
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.441-446
    • /
    • 2001
  • Background: Electrical breathing pacing has many advantages over mechanical ventilation. However, clinically permanent diaphragmatic pacing has been applied to limited patients and few temporary pacing has been reported. Our purpose is to investigate the feasibility of temporary electrical diaphragm pacing in explothoracotomy canine cases. Methods: Five dogs were studied under the general anesthesia. Left 5th intercostal space was opened. Self designed temporary pacing leads were placed around the left phrenic nerve and connected to the myostimulator. Chest wall was closed after tube insertion with underwater drainage. Millar catheter was introduced to the aorta and right atrium. Swan-Ganz catheter was introduced to the pulmonary artery. When the self respiration was shallow with deep anesthesia, hemodynamic and tidal volume were measured with the stimulator on. Results: Tidal volume increased from 143.3$\pm$51.3 ml to 272.3$\pm$87.4 ml(p=0.004). Right atrial diastolic pressure decreased from 0.7$\pm$4.0 mmHg to -10.5$\pm$4.7 mmHg(p=0.005). Pulmonary arterial diastolic pressure decreased from 6.1+2.5 mmHg to 1.2$\pm$4.8 mmHg(p<0.001). The height of water level in chest tube to show intrathoracic pressure change was from 10.3$\pm$6.7cmH$_{2}$O to 20.0$\pm$5.3 cmH$_{2}$O. Conclusion: Temporary electrical diaphragmatic pacing is a simple method to assist respiration in explothoracotomy canine cases. Self designed pacing lead is implantable and removable. Negative pressure ventilation has favorable effects on the circulatory system. Therefore, clinical application of temporary breathing pacing is feasible in thoracotomy patients to assist cardiorespiratory function.

  • PDF

Animal Experiment of the Pneumatic Ventrivular Assist Device (공압식 심실 보조기의 동물실험)

  • Park, Seong-Sik;Kim, Sam-hyun;Seo, Pil-won;Choi, Chang-hyu;Lee, Sang-hoon;Lee, Hyuk-soo;Hwang, Seung-ok;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.32 no.12
    • /
    • pp.1065-1077
    • /
    • 1999
  • Background : Ventricular assist devices(VADs) are being used for patients in postcvardiotomy cardiogenic shock status bridge to cardiac transplant settings and in post-myocardial infarction cardiogenic shock. The VAD which was developed at the Deparment of medical engineering in Dankook University College of Medicine was a pneumatically driven device and can maintain pulsatile flow. The goal of this study is to develop animal experimental models using the VAD and to clarify the reliability and hemodynamic property adequacy of end organ perfusion durability and severity of thrombotic-hemolytic tendency of the device. Material and Method : The pneumatic VAD was applied to 8 adult female lambs, We examined some hemodynamic parameters such as arterial blood pressure pulmonary capillary wedge pressure(pcwp) pulmonary artery pressure(PAP) left atrial pressure hour urine output cardiac index VAD flow EKG to determine the reliability of the VAD and hemodynamic compatibility of the experimental animals within 24 hours of experiment. We also observed the end organ perfusion durability of the VAD and thrombotic-hemolytic property of the VAD after 24 hours of VAD insertion. Result: We could monitor all hemodynamic parameters including pcwp PAP cardiac index EKG, adn hour urine as true clinical settings. We observed that the reliability of the VAD was excellent and the hemodynamic property of the experimental animal and end organ perfusion were adequate within 24 hours of experiment. In four lambs surviving 24 hours after insertion the reliability of the VAD and end organ perfusion were excellent and no thrombotic-hemolytic tendency was noted. However after 15 days of experiment the diaphragm of the VAD was torn and it was recommende that the durability of the VAD should be extended. Conclusion : e conclude that the pneumatic VAD developed at Dankook University Biomedical Engineering has good hemodynamic property and low thromboembolic tendency and presents adequate end organ perfusion but we noted that the durability of the device should be expanded further. It will be possible to do more reliable experiment in the future according to the animal experimental method developed in this study especially with the heart failure models.

  • PDF

First Successful Dynamic Cardiomyoplasty in Korea (심근 성형술 1례 보고)

  • ;;;;;;;;Igor Dubrovski, Ph.D.
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.393-397
    • /
    • 1998
  • A 25-year-old man with viral cardiomyopathy and chronic active hepatitis successfully underwent dynamic cardiomyoplasty for the first time in Korea on July 30, 1996. The patient had been intermittently dyspneic for 5 years and was admitted to our center twice because of heart failure. For the past 2 years, he was NYHA functional class III status with a left ventricular ejection fraction(LVEF) of around 30%. The patient was born with scoliosis and showed a short stature. The liver function showed elevated liver enzymes, and hepatitis B antigen was positive. The liver biopsy revealed chronic active hepatitis. The preoperative echocardiogram showed decreased left ventricular function with grade II mitral and grade II tricuspid regurgitation with dilated left and right atrium. Recently his symptoms worsened and we decided to perform a dynamic cardiomyoplasty. The left latissmus dorsi muscle(LDM) was mobilized and tested with lead placement on his right lateral decubitus position. The patient was positioned into supine and, after median sternotomy, the heart was wrapped with the mobilized muscle. The Russian made cardiomyostimulator(EKS-445) and leads (Myocardial PEMB for heart and PEMP-1 for LDM) were used. The total operation time was 8 hours and there were no perioperative episodes. Postoperatively the LDM had been trained for a 10 week period and currently the stimulation ratio is maintained at 1:4. The postoperative LVEF did not increase with the value of 30-35%. However, the patient feels better postoperatively with slightly increased activity.

  • PDF

Operation of Ascending Aorta and/or Aortic Arch (상행대동맥 및 대동맥궁의 수술)

  • 구본원;허동명;전상훈;장봉현;이종태;김규태;이응배
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1212-1217
    • /
    • 1996
  • From Dec. 1993 to May 1995, 9 male and 5 female patients ranging in age from 25 to 65 years, were operated on for ascending aorta and/or aortic arch diseases. Six patients had acute aortic dissection, type A(ruptured in 4 cases); four had ruptured ascending aortic aneurysm; three had annuloaortic ectasia(ruptured in 1 cases); one had aortic arch aneurysm. The diagnostic procedures were echo cardiography and dynamic CT scan in all patients having acute dissection or rupture. The aortic angiography was performed in two cases. Indications for operations were rupture in five cases, acute aortic dissection in five cases, severe congestive heart failure in two cases, progressive aortic insufficiency in one case and impending rupture in one case. The emergent repair was performed in ten cases(71%). The surgical treatment consisted of 6 Cabrol operations, a Cabrol operation combined with arch replacement, a modified Bentall operation, 4 replacement of ascending aorta, a replacement of aortic arch, and a replacement of ascending aorta and aortic arch. Complications were a hypoxic encephalopathy, two atrial fibrillations, a sternal deheiscence, and a mediastinitis. Two early mortality(14%) were due to intractable bleeding and multiple organ failure, and one late mortality(7%) was due to ventricular arrhythmia. In eleven survivors, follow-up period was from 2 months to 12 months and the course was uneventful.

  • PDF

Does Additional Aortic Procedure Carry a Higher Risk in Patients Undergoing Aortic Valve Replacement?

  • Kim, Tae-Hun;Park, Kay-Hyun;Yoo, Jae Suk;Lee, Jae Hang;Lim, Cheong
    • Journal of Chest Surgery
    • /
    • v.45 no.5
    • /
    • pp.295-300
    • /
    • 2012
  • Background: With growing attention to the aortopathy associated with aortic valve diseases, the number of candidates for accompanying ascending aorta and/or root replacement is increasing among the patients who require aortic valve replacement (AVR). However, such procedures have been considered more risky than AVR alone. This study aimed to compare the surgical outcome of isolated AVR and AVR combined with aortic procedures. Materials and Methods: A total of 86 patients who underwent elective AVR between 2004 and June 2010 were divided into two groups: complex AVR (n=50, AVR with ascending aorta replacement in 24 and the Bentall procedure in 26) and simple AVR (n=36). Preoperative characteristics, surgical data, intra- and postoperative allogenic blood transfusion requirement, the postoperative clinical course, and major complications were retrospectively reviewed and compared. Results: The preoperative mean logistic European System for Cardiac Operative Risk Evaluation (%) did not differ between the groups: $11.0{\pm}7.8%$ in the complex AVR group and $12.3{\pm}8.0%$ in the simple AVR group. Although complex AVR required longer cardiopulmonary bypass ($152.4{\pm}52.6$ minutes vs. $109.7{\pm}22.7$ minutes, p=0.001), the quantity of allogenic blood products did not differ ($13.4{\pm}14.7$ units vs. $13.9{\pm}11.2$ units). There was no mortality, mechanical circulatory support, stroke, or renal failure requiring hemodialysis/filtration. No difference was found in the incidence of bleeding (40% vs. 33.3%) which was defined as red blood cell transfusion ${\geq}5$ units, reoperation, or intentional delayed closure. The incidence of mediastinitis (2.0% vs. 0%), ventilator ${\geq}24$ hours (4.0% vs. 2.8%), atrial fibrillation (18.0% vs. 25.0%), mean intensive care unit stay (34.5 hours vs. 38.8 hours), and median hospital stay (8 days vs. 7 days) did not differ, either. Conclusion: AVR combined with additional aortic or root replacement showed an excellent outcome and recovery course equivalent to that after isolated AVR.

N-Terminal Pro-B-type Natriuretic Peptide Is Useful to Predict Cardiac Complications Following Lung Resection Surgery

  • Lee, Chang-Young;Bae, Mi-Kyung;Lee, Jin-Gu;Kim, Kwan-Wook;Park, In-Kyu;Chung, Kyung-Young
    • Journal of Chest Surgery
    • /
    • v.44 no.1
    • /
    • pp.44-50
    • /
    • 2011
  • Background: Cardiovascular complications are major causes of morbidity and mortality following non-cardiac thoracic operations. Recent studies have demonstrated that elevation of N-Terminal Pro-B-type natriuretic peptide (NT-proBNP) levels can predict cardiac complications following non-cardiac major surgery as well as cardiac surgery. However, there is little information on the correlation between lung resection surgery and NT-proBNP levels. We evaluated the role of NT-proBNP as a potential marker for the risk stratification of cardiac complications following lung resection surgery. Material and Methods: Prospectively collected data of 98 patients, who underwent elective lung resection from August 2007 to February 2008, were analyzed. Postoperative adverse cardiac events were categorized as myocardial injury, ECG evidence of ischemia or arrhythmia, heart failure, or cardiac death. Results: Postoperative cardiac complications were documented in 9 patients (9/98, 9.2%): Atrial fibrillation in 3, ECG-evidenced ischemia in 2 and heart failure in 4. Preoperative median NT-proBNP levels was significantly higher in patients who developed postoperative cardiac complications than in the rest (200.2 ng/L versus 45.0 ng/L, p=0.009). NT-proBNP levels predicted adverse cardiac events with an area under the receiver operating characteristic curve of 0.76 [95% confidence interval (CI) 0.545~0.988, p=0.01]. A preoperative NT-proBNP value of 160 ng/L was found to be the best cut-off value for detecting postoperative cardiac complication with a positive predictive value of 0.857 and a negative predictive value of 0.978. Other factors related to cardiac complications by univariate analysis were a higher American Society of Anesthesiologists grade, a higher NYHA functional class and a history of hypertension. In multivariate analysis, however, high preoperative NT-proBNP level (>160 ng/L) only remained significant. Conclusion: An elevated preoperative NT-proBNP level is identified as an independent predictor of cardiac complications following lung resection surgery.

Intra-aortic Balloon Pump Therapy for Hemodynamic Instability during Off-pump Coronary Artery Bypass Surgery (심폐바이패스를 사용하지 않는 관상동맥우회술 중 발생한 혈역학적 불안정에 대한 대동맥내 풍선펌프 치료)

  • Jeong, Dong-Seop;Kim, Ki-Bong;Choi, Eun-Seok
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.704-709
    • /
    • 2009
  • Background: We assessed the efficacy of intraoperative intra-aortic balloon pump therapy for achieving hemodynamic instability during off-pump coronary artery bypass surgery. Material and Method: We studied seven hundred ninety-six patients who underwent off-pump coronary artery bypass between January 2000 and December 2006. The patient were divided into group I (n=39), which received intraoperative intra-aortic balloon pump therapy, and group II (n=757), which did not receive intraoperative intra-aortic balloon pump therapy. Result: There were no differences in the operative mortalities (2.6%, 1/39 vs 0.8%, 6/757; p=0.195) and morbidities such as atrial fibrillation (p=0.691), stroke (p=0.908) and mediastinitis (p=0.781) between the 2 groups, although the ventilator support time, the length of the intensive care unit stay and the length of the hospital stay were longer in group I than in group II (p<0.05). Multivariate analysis failed to prove that group I was a high risk group for operative mortality (p=0.549). There were 3 intraoperative intra-aortic balloon pump-related complications in group I (7.9%). However, no longer complications occurred after 2003, when the surgeons began using a smaller sized 8 F catheter that was inserted using a sheathless technique. Conclusion: Intraoperative intra-aortic balloon pump therapy for achieving hemodynamic instability during off-pump coronary artery bypass surgery can be performed safely and it showed comparable clinical results to that of not using intraoperative intra-aortic balloon pump therapy.