• Title/Summary/Keyword: atrial

Search Result 1,132, Processing Time 0.034 seconds

Treatment of Atrial Fibrillation with Microwave (Microwave를 이용한 심방세동의 치료)

  • 조광현;최강주;강도균;전희재;윤영철;이양행;황윤호
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.329-334
    • /
    • 2003
  • Backgound: Cryoablation and radiofrequency ablation have been used to treat the atrial fibrillation. Some reports insisted that the microwave ablation Is a better method for a deep and extensive lesion. Material and Method: From December 2001 to July 2002, we peformed 8 microwave ablations in patients who needed mitral valve surgery (7 MVR, 1 MVR+AVR). There were 3 men and 5 women, and their mean age was 43.4$\pm$8.3 years and mean follow up period was 5.6$\pm$2.4 months respectively. The microwave was applied on endocardium or epicardium by Lynx (Afx, inc.) using a power of 45 watts for 25 seconds. We studied the left atrial dimension, the left atrial function and the sinus conversion with echocardiography and electro-cardiography at three times; 1) before the operation, 2) immediately after the operation, and 3) 6 months after the operation. Result: There was no complication and no mortality. The mean aortic clamping time was 104.6$\pm$25.0 minutes, and the mean total bypass time was 130.5$\pm$28.7 minutes. The rate of sinus conversion was 75%, A wave across the mitral valve was a mean of 77.0$\pm$24.8 cm/sec, and the AVE was a mean of 0.46$\pm$0.17 at 5.6 months postoperatively Conclusion: There was no difference in the early result of microwave ablation compared to other methods. The microwave ablation was an acceptable method due to its convenient application especially in beating heart.

$Na^{+}/Ca^{2+}$ Exchange System in Atrial Trabeculae and Vascular Smooth Muscle of the Rabbit (토끼 심방근 및 혈관 평활근에서의 $Na^{+}/Ca^{2+}$ 교환기전에 관한 연구)

  • Kim, Hee-Ju;Moon, Hyung-Ro;Earm, Yung-E;Ho, Won-Kyung
    • The Korean Journal of Physiology
    • /
    • v.22 no.1
    • /
    • pp.13-29
    • /
    • 1988
  • In order to elucidate the regulatory mechanism of intracellular calcium ion concentrations, contractions or contractures induced by $Na^{+}-removal$, calcium-application or ouabain-treatment as an index of $Na^+/Ca^{2+}$ exchange activity were studied in atrial muscle or vascular smooth muscle (aorta and renal artery) of the rabbit. The magnitude of low sodium contractures in atrial trabeculae increased with sigmoid shape when external sodium concentrations were reduced to sodium-free condition, whereas that of calcium contracture intensified in a parabolic pattern when external calcium concentrations were elevated to 8 mM. $Na^{+}-removal$ contractures were induced in a duration-dependent manner to $K^{+}-free$ exposure and same findings were observed with ouabain treatment. $Na^{+}-free$ contractures were not affected by verapamil treatment, but stimulated by $100{\mu}M\;Mn^{2+}$ and inhibited by high concentrations of $Mn^{2+}\;(2{\sim}8mM)$ in a dose-dependent manner. Ryanodine which is known to suppress the release of calcium from internal store abolished spontaneous twitch contractions induced by $K^{+}-free$ solution, but had no effect on the development $Na^{+}-free$ contractures. Na-free contractures were not always induced in vascular smooth muscle preparations. Contractures by $O\;mM\;Na^+$ were usually seen in aorta, but not often in renal artery.$50\;mM\;K^+$, noradrenaline (NA) and angiotensin II (AII) always evoked very large contraction in all preparations of vascular smooth muscle. Contractures developed by $O\;mM\;Na^+$ were not sensitive to verapamil treatment as in atrial trabeculae, but were abolished by $100{\mu}M\;Mn^{2+}$. In contrast to $Na^{+}-free$ contractures, $Mn^{2+}(100{\mu}M)$ had no effect on the contractures induced by NA or 50 mM$K^+$. Caffeine in the concentration of 10 mM evoked transient contracture in the distal renal artery. The rate of spontaneous relaxation in caffeine contracture was dependent upon the concentrations of external sodium, and had double component of relaxation when the rate of relaxation was plotted in the semilogarithmic scale of relative tension versus time. Especially late components of relaxation had more direct relation to $Na^+$ concentrations. It could be concluded that $Na^+/Ca^{2+}$ exchange mechanism in the heart has a large capacity, inhibited by $Mn^{2+}$ but not by verapamil and ryanodine, while $Na^+/Ca^{2+}$ exchange system in vascular smooth muscle has a very low capacity especially in small artery, inhibited by low concentration of $Mn^{2+}\;(100{\mu}M)$ but not affected by verapamil and ryanodine.

  • PDF

Spatial reproducibility of complex fractionated atrial electrogram depending on the direction and configuration of bipolar electrodes: an in-silico modeling study

  • Song, Jun-Seop;Lee, Young-Seon;Hwang, Minki;Lee, Jung-Kee;Li, Changyong;Joung, Boyoung;Lee, Moon-Hyoung;Shim, Eun Bo;Pak, Hui-Nam
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.5
    • /
    • pp.507-514
    • /
    • 2016
  • Although 3D-complex fractionated atrial electrogram (CFAE) mapping is useful in radiofrequency catheter ablation for persistent atrial fibrillation (AF), the directions and configuration of the bipolar electrodes may affect the electrogram. This study aimed to compare the spatial reproducibility of CFAE by changing the catheter orientations and electrode distance in an in -silico left atrium (LA). We conducted this study by importing the heart CT image of a patient with AF into a 3D-homogeneous human LA model. Electrogram morphology, CFAE-cycle lengths (CLs) were compared for 16 different orientations of a virtual bipolar conventional catheter (conv-cath: size 3.5 mm, inter-electrode distance 4.75 mm). Additionally, the spatial correlations of CFAE-CLs and the percentage of consistent sites with CFAE-CL<120 ms were analyzed. The results from the conv-cath were compared with that obtained using a mini catheter (mini-cath: size 1 mm, inter-electrode distance 2.5 mm). Depending on the catheter orientation, the electrogram morphology and CFAE-CLs varied (conv-cath: $11.5{\pm}0.7%$ variation, mini-cath: $7.1{\pm}1.2%$ variation), however the mini-cath produced less variation of CFAE-CL than conv-cath (p<0.001). There were moderate spatial correlations among CFAE-CL measured at 16 orientations (conv-cath: $r=0.3055{\pm}0.2194$ vs. mini-cath: $0.6074{\pm}0.0733$, p<0.001). Additionally, the ratio of consistent CFAE sites was higher for mini catheter than conventional one ($38.3{\pm}4.6%$ vs. $22.3{\pm}1.4%$, p<0.05). Electrograms and CFAE distribution are affected by catheter orientation and electrode configuration in the in-silico LA model. However, there was moderate spatial consistency of CFAE areas, and narrowly spaced bipolar catheters were less influenced by catheter direction than conventional catheters.

Correct Closure of the Left Atrial Appendage Reduces Stagnant Blood Flow and the Risk of Thrombus Formation: A Proof-of-Concept Experimental Study Using 4D Flow Magnetic Resonance Imaging

  • Min Jae Cha;Don-Gwan An;Minsoo Kang;Hyue Mee Kim;Sang-Wook Kim;Iksung Cho;Joonhwa Hong;Hyewon Choi;Jee-Hyun Cho;Seung Yong Shin;Simon Song
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.647-659
    • /
    • 2023
  • Objective: The study was conducted to investigate the effect of correct occlusion of the left atrial appendage (LAA) on intracardiac blood flow and thrombus formation in patients with atrial fibrillation (AF) using four-dimensional (4D) flow magnetic resonance imaging (MRI) and three-dimensional (3D)-printed phantoms. Materials and Methods: Three life-sized 3D-printed left atrium (LA) phantoms, including a pre-occlusion (i.e., before the occlusion procedure) model and correctly and incorrectly occluded post-procedural models, were constructed based on cardiac computed tomography images from an 86-year-old male with long-standing persistent AF. A custom-made closed-loop flow circuit was set up, and pulsatile simulated pulmonary venous flow was delivered by a pump. 4D flow MRI was performed using a 3T scanner, and the images were analyzed using MATLAB-based software (R2020b; Mathworks). Flow metrics associated with blood stasis and thrombogenicity, such as the volume of stasis defined by the velocity threshold ($\left|\vec{V}\right|$ < 3 cm/s), surface-and-time-averaged wall shear stress (WSS), and endothelial cell activation potential (ECAP), were analyzed and compared among the three LA phantom models. Results: Different spatial distributions, orientations, and magnitudes of LA flow were directly visualized within the three LA phantoms using 4D flow MRI. The time-averaged volume and its ratio to the corresponding entire volume of LA flow stasis were consistently reduced in the correctly occluded model (70.82 mL and 39.0%, respectively), followed by the incorrectly occluded (73.17 mL and 39.0%, respectively) and pre-occlusion (79.11 mL and 39.7%, respectively) models. The surfaceand-time-averaged WSS and ECAP were also lowest in the correctly occluded model (0.048 Pa and 4.004 Pa-1, respectively), followed by the incorrectly occluded (0.059 Pa and 4.792 Pa-1, respectively) and pre-occlusion (0.072 Pa and 5.861 Pa-1, respectively) models. Conclusion: These findings suggest that a correctly occluded LAA leads to the greatest reduction in LA flow stasis and thrombogenicity, presenting a tentative procedural goal to maximize clinical benefits in patients with AF.

Complications of transcatheter closure of atrial septal defects using the amplatzer septal occluder (심방 중격 결손의 경피적 폐쇄술 후 발생한 합병증에 관한 연구)

  • Jea, Seo Jin;Kwon, Hyo Jin;Jang, Gi Young;Lee, Jae Young;Kim, Soo Jin;Son, Chang Sung;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.401-408
    • /
    • 2008
  • Purpose : Transcatheter closure of atrial septal defects (ASD) is currently established therapy as an alternative to surgery. But rarely, complications are reported in some studies. We report early and intermediate term complications associated with transcatheter closure of atrial septal defects using the Amplatzer septal occluder (ASO). Methods : From June 2003 to May 2006, 64 patients underwent transcatheter closure of secundum ASD or patent foramen ovale using the ASO. The ratio of male to female was 1:2.4, the median age was 17 years (range: 2.6-64 years) and their median weight was 47.5 kg (range: 2.6-64 kg). Results : The median diameter of ASD measured with transthoracic or transesophageal echocardiography was 15 mm (range: 6-28 mm), the median balloon stretched diameter was 18 mm (range: 6.5-34 mm), and the median size of device was 19.5 mm (range: 6-36 mm), was little difference with balloon stretched diameter. There were 10 cases of complications: arrhythmia (2), device malformation (2), aorta to right atrial fistula (1), hemolytic anemia (1), mitral valve encroachment (1), malposition (1), residual shunt (1), and inferior vena cava perforation (1). Conclusion : Transcatheter closure of ASD using ASO is effective and safe therapy. However, significant complications such as aorta to atrial fistula, atrial erosion, or device embolization can happen, so an appropriate selection of patient and device in relevance to size and anatomy of ASD is important for successful closure.

Analysis of risk factors of atrial fibrillation after coronary artery bypass grafting (관상동맥 우회로 조성수술후 발생하는 심 방세동의 위험요인 분석)

  • Yu, Gyeong-Jong;Go, Yeong-Ho;Im, Sang-Hyeon;Gang, Myeon-Sik
    • Journal of Chest Surgery
    • /
    • v.29 no.6
    • /
    • pp.599-605
    • /
    • 1996
  • A total of 249 patients undergoing isolated coronary revascularization were studied for the occurrence of postoperative atrial fibrillation(AF). Possible associations of this arrhythmia with various preoperative, intraoperative and postoperative factors were studied by univariate and multivariate analysis. The overall incidence of postoperative AF was 15%, with the median time occurence of 48 hours(mean time : 59.1 $\pm$ 56.9 hours) after arrival to the intensive care unit. Cardiac index decreased significantly after occurence of AF(p=0.001). There were no in-hospital complications in those patients with AF. Univariate studies indicated preoperative ejection fract on(EF), triglyceride level, postoperative peak CKMB isoenzpme and atrial pacing to be the dominant factor promoting postoperative AF, with an increasing prevalence in lower EF(p=0.025), triglyceride(p=0.006) and peak CKMB isoenzyme(p=0.002), and in patients with atrial pacing(p=0.001). Hospital stay(p=0.001) and late mortality(p=0.003) were significantly increased in patients with postoperative AF Multivariate analysis showed that body weight and postoperative atrial pacing to be the dominant factor promoting postoperative AF, with an increasing prevalence in over- weight patients(p=0.011) and patients with atrial pacing(p=0.001). Both univariate and multivariate analy- sis showed that the age was not a significant factor but tended to promote postoperative AF respectively (p=0.053, 0.064). After 30.1 $\pm$ 11.4 months gfollow-up, those patients with AF had sinus rhythm. We think that we must try to prevent postoperative AF after ccoronary artery bypass grafting because of its deleterio s hemodynamic effect, prolonged hospital stay, and increased late mortality.

  • PDF