• Title/Summary/Keyword: atmospheric property

Search Result 145, Processing Time 0.029 seconds

Property Analysis of Municipal Solid Waste and Estimation of CO2 Emissions from Waste Incinerators (생활폐기물 특성 분석 및 소각시설의 CO2 배출량 평가)

  • Kim, Byung-Soon;Kim, Shin-Do;Kim, Chang-Hwan;Lee, Tae-Jung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.657-665
    • /
    • 2010
  • Carbon dioxide ($CO_2$) is known to be a major greenhouse gas partially emitted from waste combustion facilities. According to the greenhouse gas emission inventory in Korea, the quantity of the gas emitted from waste sector in 2005 represents approximately 2.5 percent of all domestic greenhouse gas emission. Currently, the emission rate of greenhouse gas from the waste sector is relatively constant partly because of both the reduced waste disposal in landfills and the increased amounts of waste materials for recycling. However, the greenhouse gas emission rate in waste sectors is anticipated to continually increase, mainly due to increased incineration of solid waste. The objective of this study was to analyze the property of Municipal Solid Waste (MSW) and estimate $CO_2$ emissions from domestic MSW incineration facilities. The $CO_2$ emission rates obtained from the facilities were surveyed, along with other two methods, including Tier 2a based on 2006 IPCC Guideline default emission factor and Tier 3 based on facility specific value. The $CO_2$ emission rates were calculated by using $CO_2$ concentrations and gas flows measured from the stacks. Other parameters such as waste composition, dry matter content, carbon content, oxidation coefficient of waste were included for the calculation. The $CO_2$ average emission rate by the Tier 2a was 34,545 ton/y, while Tier 3 was 31,066 ton/y. Based on this study, we conclude that Tier 2a was overestimated by 11.2 percent for the $CO_2$ emission observed by Tier 3. Further study is still needed to determine accurate $CO_2$ emission rates from municipal solid waste incineration facilities and other various combustion facilities by obtaining country-specific emission factor, rather than relying on IPCC default emission factor.

Photocatalytic Property of Nano-Structured TiO$_2$ Thermal Sprayed Coating - Part II: TiO$_2$ -WO$_3$ Coating - (나노구조 TiO$_2$용사코팅의 미세조직 제어 공정기술 개발과 광촉매 특성평가 - Part II: TiO$_2$- WO$_3$ 코팅 -)

  • 이창훈;최한신;이창희;김형준;신동우
    • Journal of Welding and Joining
    • /
    • v.21 no.4
    • /
    • pp.46-55
    • /
    • 2003
  • TiO$_2$-WO$_3$(8.2wt%) coatings were prepared by the APS (Atmospheric Plasma Spraying) process to clarify the relationship between the process parameters(H$_2$ gas flow rate of plasma 2nd gas and spraying distance) of the APS coating and photo-decomposition efficiency kinetics of the MB(methylene blue) aqueous solution decomposition and to understand the effect of addition of WO$_3$ on photocatalytic properties of TiO$_2$ sprayed coating. Further, the temperature and velocity of flying particles were measured by DPV-2000 to investigate the relationship between microstructure of coatings and process parameters. Properties of coatins were investigated by XRD, SEM, XPS, RAMAN, UV/VIS spectrometer. In case of the TiO$_2$-WO$_3$(8.2wt%) coating, it had a lower anatase fraction than that of pure-TiO$_2$ coatings because of flying in the higher temperature plasma plume by the heavy weight of TiO$_2$, WO$_3$. And, when WO$_3$ added powders were spayed, the doping effects of W ions substituted into the Ti ion sites was not occured during melting and solidification cycles of spraying. It was found that the addition of WO$_3$ was ineffective effective on increasing photo-decomposition efficiency of TiO$_2$ sprayed coating.

Fabrication of a Film Coated with Conducting Polymer Using One Atmospheric Pressure Plasma (대기압 플라즈마를 이용한 전도성 고분자 코팅 필름 제조)

  • Jung, Jin-Suk;Yang, In-Young;Myung, Sung-Woon;Choi, Ho-Suk;Kim, Jong-Hoon
    • Polymer(Korea)
    • /
    • v.31 no.4
    • /
    • pp.308-314
    • /
    • 2007
  • A composite film of polyurethane(PU)-graft-poly(acrylic acid) (PAAc)/polyaniline (PU-g-AAc/PANI) was successfully fabricated for the purpose of adding conductivity on the surface of a general purpose polymer and improving adhesive property between the general purpose polymer and conducting polymer layer. The results from ATR-FTIR and XPS analyses also supported the successful synthesis of the composite film by showing characteristic peaks for every step. A low surface resistivity of $2{\times}10^3\;ohm/sq$ proved the surface conductivity of synthesized PU-g-AAc/PANI film and the surface resistance decreased with increasing the amount of grafted AAc, which acted as a dopant for PANI film.

Analysis of An Outflow Boundary Induced Heavy Rainfall That Occurred in the Seoul Metropolitan Area (수도권에서 유출류 경계(Outflow Boundary)를 따라 발생한 집중호우 분석)

  • Lee, Ji-Won;Min, Ki-Hong
    • Atmosphere
    • /
    • v.27 no.4
    • /
    • pp.455-466
    • /
    • 2017
  • In Korea, property and human damages occur annually due to heavy precipitation during the summer. On August 8, 2015, heavy rainfall occurred in the Seoul metropolitan area due to an outflow boundary, and $77mmhr^{-1}$ rainfall was recorded in Gwangju, Gyeonggi Province. In this study, the simulation of the WRF numerical model is performed to understand the cause and characteristics of heavy rainfall using the Conditional Instability of the Second Kind (CISK), potential vorticity (PV), frontogenesis function, and convective available potential energy (CAPE) analyses, etc. Convective cells initiated over the Shandong Peninsula and located on the downwind side of an upper level trough. Large amounts of water vapor were supplied to the Shandong Peninsula along the southwestern edge of a high pressure system, and from the remnants of typhoon Soudelor. The mesoscale convective system (MCS) developed through CISK process and moved over to the Yellow Sea. The outflow boundary from the MCS progressed east and pushed cold pool eastward. The warm and humid air over the Korean Peninsula further enhanced convective development. As a result, a new MCS developed rapidly over land. Because of the latent heat release due to convection and precipitation, strong potential vorticity was generated in the lower atmosphere. The rapid development of MCS and the heavy rainfall occurred in an area where the CAPE value was greater than $1300Jkg^{-1}$ and the fronto-genesis function value of 1.5 or greater coincided. The analysis result shows that the MCS driven by an outflow boundary can be identified using CISK process.

Adsorption Characteristics of Benzene and MEK on Surface Oxidation Treated Adsorbent -Surface Oxidation by HNO3, H2SO4 and (NH4)2S2O8- (표면산화 처리된 흡착제의 Benzene 및 MEK 흡착 특성 - HNO3, H2SO4 및 (NH4)2S2O8에 의한 표면산화-)

  • Shim, Choon-Hee;Lee, Woo-Keun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.25-33
    • /
    • 2006
  • The objective of this research is to improve the adsorption capacity of adsorbent made from MSWI (Municipal Solid Waste Incinerator) fly ash by surface oxidation. Used oxidation agents were $HNO_{3}$, $H_{2}SO_{4}$ and $(NH_{4})_{2}S_{2}O_{8}$. These agents can modify the surface property of an adsorbent such as specific surface area, pore volume, and functional group. The surface structure was studied by BET method with $N_{2}$ adsorption. The acid value and base value were determined by Boehm's method. The adsorption properties were investigated with benzene and MEK (Methylethylketone). According to the results, the specific surface area of the adsorbent was increased from 309.2 $m^{2}$/g to 553.2 $m^{2}$/g by $HNO_{3}$ oxidation. But $H_{2}SO_{4}$ and $(NH_{4})_{2}S_{2}O_{8}$ oxidation was decreased slightly. After Oxidation, surface acid value increased, but base value decreased. FAA-N shows the highest acid value. The content of oxygen increased greatly and oxygen group was created on the adsorbent surface. The surface oxidation improved the adsorbing capacity for MEK. The amount of adsorbing MEK was increased from 189 $m^{2}$/g to 639 $m^{2}$/g by $HNO_{3}$ oxidation.

Chemical Properties of Indoor Individual Particles Collected at the Daily Behavior Spaces of a Factory Worker

  • Ma, Chang-Jin;Kang, Gong-Unn;Sakai, Takuro
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.122-130
    • /
    • 2017
  • The main purpose of the study was to clarify the properties of individual particles collected at each behavior space of a factory worker. The samplings of size-segregated ($PM_{2.1-1.1}$ and $PM_{4.7-3.3}$) indoor particles were conducted at three different behavior spaces of a factory worker who is engaged in an auto parts manufacturing plant (i.e., his home, his work place in factory, and his favorite restaurant). Elemental specification (i.e., relative elemental content and distribution in and/or on individual particles) was performed by a micro-PIXE system. Every element detected from the coarse particulate matters of home was classified into three groups, i.e., a group of high net-counts (Na, Al, and Si), a group of intermediate net-counts (Mg, S, Cl, K, and Ca), and a group of minor trace elements (P, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, and Pb). The results of EF for $PM_{4.7-3.3}$ in home indicated that several heavy metals were generated from the sources within the house itself. An exceptional feature shown in the individual particles in workplace is that Cr, Mn, and Co were clearly detected in both fine and coarse particles. Cluster analysis suggested that the individual coarse particles ($PM_{4.7-3.3}$) collected at the indoor of factory were chemically heterogeneous and they modified with sea-salt, mineral, and artificially derived elements. The principal components in individual coarse particles collected at restaurant were sea-salt and mineral without mixing with harmful trace elements like chromium and manganese. Compared to the indoor fine particles of home and restaurant, many elements, especially, Cl, Na, Cr, Mn, Pb, and Zn showed overwhelmingly high net-counts in those of factory.

Identification of triacylglycerols in coix seed extract by preparative thin layer chromatography and liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry

  • Sim, Hee-Jung;Lee, Seul gi;Park, Na-Hyun;Kim, Youna;Cho, Hyun-Woo;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.102-111
    • /
    • 2017
  • Here we reported a methodology for identification of triacylglycerols (TAGs) and diacylglycerols (DAGs) in coix seed by preparative thin layer chromatography (prep-TLC) and non-aqueous reversed-phase liquid chromatography (NARP LC)-atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (MS/MS). Lipid components were extracted from coix seed by reflux extraction using n-hexane for 3 hr. TAGs and DAGs in coix seed extract were effectively purified and isolated from matrix interferences by prep-TLC and then analyzed by LC-APCI-MS and MS/MS for identification. TAGs were effectively identified taking into consideration of their LC retention behavior, APCI-MS spectra patterns, and MS/MS spectra of $[DAG]^+$ ions. In MS/MS spectra of TAGs, diacylglycerol-like fragment $[DAG]^+$ ions were useful to identify TAGs with isobaric fragment ions. Based on an established method, 27 TAGs and 8 DAGs were identified in coix seed extract. Among them, 15 TAGs and 8 DAGs were for the first time observed in coix seed. Interestingly, some of TAGs isolated by prep-TLC were partly converted into DAGs through probably photolysis process during storing in room temperature. Thus, degradation phenomenon of TAGs should be considered in the quality evaluation and nutritional property of coix seed. LC-APCI-MS/MS combined with prep-TLC will be practical method for precise TAG and DAG analysis of other herbal plants.

Seasonal Variations of Chemical Composition and Optical Properties of Aerosols at Seoul and Gosan (서울과 고산의 에어로졸 화학성분과 광학특성의 계절변화)

  • Lee, S.;Ghim, Y.S.;Kim, S.W.;Yoon, S.C.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.4
    • /
    • pp.470-482
    • /
    • 2008
  • Seasonal variations of chemical composition and optical properties of aerosols at Seoul and Gosan were investigated using the ground-based aerosol measurements and an optical model calculation. The mass fraction of elemental carbon was $8{\sim}17%$, but its contribution on light absorption was high up to $29{\sim}48%$ in Seoul. In Gosan, the contribution of water soluble aerosols on aerosol extinction was $83{\sim}94%$ due to the high mass fraction of these particles in the range of $56{\sim}88%$. Model calculation showed that the water holding capacity of aerosols was larger in Gosan than in Seoul because of higher relative humidity and temperature along with abundant water soluble aerosols. Difference between measured and calculated aerosol optical depths was the highest in summer. This was because aerosol optical depth calculated from ground-based measurements could not consider aerosol loadings at high altitude in spite of high column-integrated aerosol loadings observed by Sun photometer. Although hygroscopic growth was expected to be dominant in summer, the mass concentration of water soluble aerosols was too low to permit this growth.

Thermal and Hygroscopic Properties of Indoor Particulate Matter Collected on an Underground Subway Platform

  • Ma, Chang-Jin;Lee, Kyoung-Bin;Zhang, Daizhou;Yamamoto, Mariko;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • In order to clarify the thermal and hygroscopic properties of indoor particulate matter (PM) in a semiclosed subway space, which is critically important for understanding of the distinctive particle formation processes as well as the assessment of their health effects, the size-resolved PMs (i.e., $PM_{2.5}$ and $PM_{10-2.5}$) were intensively collected on the platform of Miasageori station on the Seoul Subway Line-4. The elemental concentrations in soluble and insoluble fractions were determined by PIXE from the bulkily pretreated $PM_{2.5}$. The thermal and hygroscopic characteristics of individual particles were investigated via a combination of the unique pretreatment techniques (i.e., the high-temperature rapid thermal process and the water dialysis) and SEM-EDX analysis. Iron and calcium were unequaled in insoluble and soluble $PM_{2.5}$ fractions, respectively, with overwhelming concentration. The SEM-EDX's elemental net-counts for the pre- and post-pyrolyzed PMs newly suggest that magnesium and several elements (i.e., silica, aluminum, and calcium) may be readily involved in the newly generated subway fine PM by a high-temperature thermal processing when trains are breaking and starting. Through the water dialysis technique, it turned out that calcium has meaningful amount of water soluble fraction. Furthermore, the concentrations of the counter-ions associated with the calcium in subway $PM_{10-2.5}$ were theoretically estimated.

Characteristics of Molecular Band Energy Structure of Lipid Oxidized Mammalian Red Blood Cell Membrane by Air-based Atmospheric Pressure Dielectric Barrier Discharge Plasma Treatment

  • Lee, Jin Young;Baik, Ku Youn;Kim, Tae Soo;Jin, Gi-Hyeon;Kim, Hyeong Sun;Bae, Jae Hyeok;Lee, Jin Won;Hwang, Seung Hyun;Uhm, Han Sup;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.262.1-262.1
    • /
    • 2014
  • Lipid peroxidation induces functional deterioration of cell membrane and induces cell death in extreme cases. These phenomena are known to be related generally to the change of physical properties of lipid membrane such as decreased lipid order or increased water penetration. Even though the electric property of lipid membrane is important, there has been no report about the change of electric properties after lipid peroxidation. Herein, we demonstrate the molecular energy band change in red blood cell membrane through peroxidation by air-based atmospheric pressure DBD plasma treatment. Ion-induced secondary electron emission coefficient (${\gamma}$ value) was measured by using home-made gamma-focused ion beam (${\gamma}$-FIB) system and electron energy band was calculated based on the quantum mechanical Auger neutralization theory. The oxidized lipids showed higher gamma values and lower electron work functions, which implies the change of surface charging or electrical conductance. This result suggests that modified electrical properties should play a role in cell signaling under oxidative stress.

  • PDF