• Title/Summary/Keyword: atmospheric pressure plasma source

Search Result 36, Processing Time 0.025 seconds

Micro-Spot Atmospheric Pressure Plasma Production for the Biomedical Applications

  • Hirata, T.;Tsutsui, C.;Yokoi, Y.;Sakatani, Y.;Mori, A.;Horii, A.;Yamamoto, T.;Taguchi, A.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.44-45
    • /
    • 2010
  • We are currently conducting studies on culturing and biocompatibility assessment of various cells such as neural stem cells and induced pluripotent stem cells(IPS cells) on carbon nanotube (CNT), on nerve regeneration electrodes, and on silicon wafers with a focus on developing nerve integrated CNT based bio devices for interfacing with living organisms, in order to develop brain-machine interfaces (BMI). In addition, we are carried out the chemical modification of carbon nanotube (mainly SWCNTs)-based bio-nanosensors by the plasma ion irradiation (plasma activation) method, and provide a characteristic evaluation of a bio-nanosensor using bovine serum albumin (BSA)/anti-BSA binding and oligonucleotide hybridization. On the other hand, the researches in the case of "novel plasma" have been widely conducted in the fields of chemistry, solid physics, and nanomaterial science. From the above-mentioned background, we are conducting basic experiments on direct irradiation of body tissues and cells using a micro-spot atmospheric pressure plasma source. The device is a coaxial structure having a tungsten wire installed inside a glass capillary, and a grounded ring electrode wrapped on the outside. The conditions of plasma generation are as follows: applied voltage: 5-9 kV, frequency: 1-3 kHz, helium (He) gas flow: 1-1.5 L/min, and plasma irradiation time: 1-300 sec. The experiment was conducted by preparing a culture medium containing mouse fibroblasts (NIH3T3) on a culture dish. A culture dish irradiated with plasma was introduced into a $CO_2$-incubator. The small animals used in the experiment involving plasma irradiation into living tissue were rat, rabbit, and pick and are deeply anesthetized with the gas anesthesia. According to the dependency of cell numbers against the plasma irradiation time, when only He gas was flowed, the growth of cells was inhibited as the floatation of cells caused by gas agitation inside the culture was promoted. On the other hand, there was no floatation of cells and healthy growth was observed when plasma was irradiated. Furthermore, in an experiment testing the effects of plasma irradiation on rats that were artificially given burn wounds, no evidence of electric shock injuries was found in the irradiated areas. In fact, the observed evidence of healing and improvements of the burn wounds suggested the presence of healing effects due to the growth factors in the tissues. Therefore, it appears that the interaction due to ion/radicalcollisions causes a substantial effect on the proliferation of growth factors such as epidermal growth factor (EGF), nerve growth factor (NGF), and transforming growth factor (TGF) that are present in the cells.

  • PDF

Development of an Atmospheric Pressure Plasma Source for Resist Removal on 12 Inch Si Wafers

  • Yu, Seung-Yeol;Seok, Dong-Chan;Park, Jun-Seok;Yu, Seung-Min;No, Tae-Hyeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.488-488
    • /
    • 2012
  • 상압에서 12인치 실리콘 웨이퍼 표면처리가 가능한 장치를 개발하였다. 배치타입 공정으로 플라즈마 발생 전극은 직경 340 mm의 대면적 원형 형태을 가지고 있다. 시스템은 탈부착이 가능한 플라즈마 모듈부와 공정챔버로 나누어지며 균일도를 높이기 위해 웨이퍼스테이지는 가열, 회전 및 축간 조절이 가능하게 설계하였다. 플라즈마발생은 DBD 전극방식을 채용하고 있으며 공정가스흐름 및 전극배열 등을 연구하였다. 또한, 기판 온도, 가스 조합 등의 공정파리미터를 변화시켜가며 높은 애슁 속도 및 균일도를 얻기 위한 실험이 진행되었다. 주파수 15 kHz, 인가 파워 7 kW, 시편 가열 온도 95도, 60 rpm, 80 spm에서 분당 200 nm의 PR제거율을 확인하였다.

  • PDF

Optical Diagnostics of Nanopowder Processed in Liquid Plasmas

  • Bratescu, M.A.;Saito, N.;Takai, O.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.17-18
    • /
    • 2011
  • Plasma in liquid phase has attracted great attention in the last few years by the wide domain of applications in material processing, decomposition of organic and inorganic chemical compounds and sterilization of water. The plasma in liquid is characterized by three main regions which interact each - other during the plasma operation: the liquid phase, which supply the plasma gas phase with various chemical compounds and ions, the plasma in the gas phase at atmospheric pressure and the interface between these two regions. The most complex region, but extremely interesting from the fundamental, chemical and physical processes which occur here, is the boundary between the liquid phase and the plasma gas phase. In our laboratory, plasma in liquid which behaves as a glow discharge type, is generated by using a bipolar pulsed power supply, with variable pulse width, in the range of 0.5~10 ${\mu}s$ and 10 to 30 kHz repetition rate. Plasma in water and other different solutions was characterized by electrical and optical measurements. Strong emissions of OH and H radicals dominate the optical spectra. Generally water with 500 ${\mu}S/cm$ conductivity has a breakdown voltage around 2 kV, depending on the pulse width and the repetition rate of the power supply. The characteristics of the plasma initiated in ultrapure water between pairs of different materials used for electrodes (W and Ta) were investigated by the time-resolved optical emission and the broad-band absorption spectroscopy. The deexcitation processes of the reactive species formed in the water plasma depend on the electrode material, but have been independent on the polarity of the applied voltage pulses. Recently, Coherent anti-Stokes Raman Spectroscopy method was employed to investigate the chemistry in the liquid phase and at the interface between the gas and the liquid phases of the solution plasma system. The use of the solution plasma allows rapid fabrication of the metal nanoparticles without being necessary the addition of different reducing agents, because plasma in the liquid phase provides a reaction field with a highly excited energy radicals. We successfully synthesized gold nanoparticles using a glow discharge in aqueous solution. Nanoparticles with an average size of less than 10 nm were obtained using chlorauric acid solutions as the metal source. Carbon/Pt hybrid nanostructures have been obtained by treating carbon balls, synthesized in a CVD chamber, with hexachloro- platinum acid in a solution plasma system. The solution plasma was successfully used to remove the template remained after the mesoporous silica synthesis. Surface functionalization of the carbon structures and the silica surface with different chemical groups and nanoparticles, was also performed by processing these materials in the liquid plasma.

  • PDF

Physical and Chemical Characteristics of Waste Automotive Catalysts (자동차 폐촉매의 물리 화학적 특성)

  • Seo, Seong-Gyu;Moon, Joung-Sun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.819-825
    • /
    • 2000
  • The physico-chemical characteristics and the combustion activities of a waste automotive catalyst were carried out in this study. The physico-chemical characteristics of waste automotive catalyst was examined by EA(Elemental analysis), ICP-AES (Inductively coupled plasma-atomic emission spectrophotometer), and XRD(X-ray diffraction) analysis. Carbon deposit amount was higher in front brick than rear brick of catalyst, and increased with mileage. The content of Pt. Pd and Rh in waste automotive catalyst was different from the car manufacturing company. The combustion activities of waste automotive catalyst were investigated for acetaldehyde as a model VOC in a fixed bed reactor at atmospheric pressure. The catalytic activity of rear brick for acetaldehyde combustion was better than front brick of waste automotive catalyst. The catalytic activity of waste automotive catalyst for acetaldehyde combustion decreased with mileage. The linear relationship between catalytic activity and mileage was negative and has a very excellent correlation. Finally, the waste automotive catalyst has a good catalytic activity for acetaldehyde combustion. and can be used to control of small emission source.

  • PDF

Evaluation of the Potential of Nitrogen Plasma to Cosmetics (질소 플라즈마의 화장품 가능성 평가)

  • Lee, So Min;Jung, So Young;Brito, Sofia;Heo, Hyojin;Cha, Byungsun;Lei, Lei;Lee, Sang Hun;Lee, Mi-Gi;Bin, Bum-Ho;Kwak, Byeong-Mun
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.3
    • /
    • pp.189-196
    • /
    • 2022
  • Plasma refers to an ionized gas that is often referred to as "the fourth phase of matter", following solid, liquid, and gas. Plasma has traditionally been utilized for industrial applications such as welding and neon signs, but its promise in biomedical fields such as cancer treatment and dermatology has lately been recognized. Indeed, due to its beneficial effects in promoting collagen production, improving skin tone, and eliminating harmful bacteria in the skin, plasma treatment constitutes an important target for dermatological research. In this study, a plasma device for cosmetic manufacturing based on nitrogen, the main component of the atmosphere, was designed and assembled. Moreover, nitric oxide (NO) was selected since is easier to follow and evaluate than other nitrogen plasma active species, and its contents were measured to perform a quantitative and qualitative evaluation of plasma. First, an injection method, using different proximities labeled "sinking" and "non sinking" treatments, was performed to test the most efficient plasma treatment method. As a result, it was observed that the formulation obtained by a non sinking treatment was more effective. Furthermore, toner and ampoule were selected as cosmetics formulations, and the characteristics of the formulation and changes in the injected plasma state were observed. In both formulations, the successful injection of NO plasma was 2 times higher in toner formulation than ampoule formulation, and it gradually decreased with time, having dissipated after a week. It was confirmed that the nitrogen plasma used did not affect the stability of the toner and ampoule formulations at low temperature (4 ℃), room temperature (25 ℃), and high temperature (37 ℃ and 50 ℃) conditions. The results of this study demonstrate the potential of plasma cosmetics and highlight the importance of securing the stability of the injected plasma.

대기압 유전체 배리어 방전을 이용한 폴리머 박막의 증착과 특성 분석에 대한 연구

  • Kim, Gi-Taek;Suzaki, Yoshifumi;Kim, Yun-Gi
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.38.2-38.2
    • /
    • 2011
  • 폴리머 박막은 그 고유한 특성으로 인해 여러 산업적으로 널리 사용되고 있는 재료이다 예로 의약품이나 식품 포장지의 배리어, 전자부품의 절연체, 반도체 공정에서의 사용, 혹은 부식방지를 위해 사용 되어지기도 한다. 이 폴리머 박막을 증착 하기 위한 방법으로 이전부터 CVD (Chemical Vapor Deposition) 방법이 많이 사용되었고 지금까지도 가장 많이 사용되는 방법이다. CVD를 사용하여 $SiO_2$-like 필름의 증착은 전구체(precursor)로 Silane ($SiH_4$)을 사용하였으며, 플라즈마 발생 소스(source)로 열 혹은 전기장 등을 사용 하며 공정 시 압력 또한 대부분 저압 하에서 실시 하였다. 이와 같은 이전 CVD 방법의 문제는 사용되는 Silane 자체가 인체에 해로울 정도로 독성이 있으며 폭발성도 같이 가지고 있어 작업환경의 위험성이 높으며 열을 사용한 CVD의 경우 높은 공정 온도로 인해 증착 할 수 있는 대상이 제한 되어 지며 높은 열의 발생을 위해 많은 에너지의 소비가 필요하다. 저압 플라즈마를 사용한 CVD 는 공정상 높은 열의 발생이 일어나지 않아 기판 운용상 문제가 되지 않지만 저압 환경에서 해당 공정이 이루어기 때문에 인해 필수적으로 고가의 진공 챔버가 필수적이며 저압을 유지할 고가의 진공 펌프나 추가 장비들이 필요하게 된다, 또한 챔버 내에서 이루어지는 공정으로 인해 공정의 연속성이 떨어져 시잔비용 또한 많이 잡아 먹는다. 이러한 열 혹은 저압 플라즈마등을 사용한 공정의 단점을 해결하기 위해 여러 연구자들이 다양한 방법을 통해 연구를 하였다. 대기압 유전체 배리어 방전(AP-DBD: Atmospheric Pressure-Dielectric Barrier Discharge)을 사용한 폴리머 박막의 증착은 이전 전통적인 방법에 비해 낮은 장비 가격과 낮은 공정 온도 그리고 연속적인 공정 등의 장점이 있는 폴리머 박막 증착 방법 이다. 대기압 유전체 배리어 방전 공정 변수로 공급 전압 및 주파수 그리고 공급 전압의 영향, 전구체를 유전체 배리어 방전 전극으로 이동 시키기 위해 사용된 캐리어 가스의 종류 및 유량, 화학양론적 계수를 맞추기 위해 같이 포함되는 산소 가스의 유량, DBD 전극의 형태에 따른 증착 박막의 균일성 등 이 존재하며 이런 많은 변수 들에 대한 연구가 진행 되었지만 아직 이 대기압 DBD를 이용한 폴리머 박막의 증착에 대한 명확한 이해는 아직 완전 하다 할 수 없다. 본 연구에서는 이러한 대기압 DBD를 이용하여 폴리머 박막의 증착시 영향을 미치는 많은 공정 변수 등이 박막생성에 미치는 영향과 증착된 박막의 성질에 대한 연구를 진행 하였다.

  • PDF