• Title/Summary/Keyword: asymmetry ratio

Search Result 199, Processing Time 0.021 seconds

A study on the stability analysis for asymmetry parallel tunnel with rock pillar (암반 필라를 포함한 비대칭 근접 병설터널의 안정성 평가에 관한 연구)

  • Kim, Do-Sik;Kim, Young-Geun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.4
    • /
    • pp.387-401
    • /
    • 2007
  • Recently, because of the restriction of land for construction and interference of adjacent structure, parallel tunnels with small clearance have been planned and constructed in many sites. In this case, the stability of pillar at center part is very important factor to satisfy the stability of tunnel structure under the construction. In this paper, numerical analyses for the asymmetry parallel tunnels with a narrow width of pillar have been carried out to search for the optimum reinforcement measure for rock pillar and verify the stability of tunnel. Rock pillar between each single tunnel is supposed to be under heavy load by rock mass. The analysis of stress state at rock pillar at various cases for construction conditions is required to investigate the structural behaviour of tunnels and stability of the pillar. Strength-stress ratio is calculated based on the failure theory of rock and the safety factor of tunnel is computed with strength reduction technique. Through these numerical results, reasonable reinforcement measures for rock pillar at parallel tunnel were established and recommended.

  • PDF

A Novel Asymmetric Vertical Directional Coupler Switch (비대칭 수직 방향성 결합기 스위치)

  • Jo, Seong-Chan;Jeong, Byeong-Min;Kim, Bu-Gyun;Choe, Ji-Yeon;Hwang, Hyeong-Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.5
    • /
    • pp.31-40
    • /
    • 2002
  • We propose a novel ultra-short asymmetric vertical directional coupler switch (VDCS) with high extinction ratios larger than 30㏈ composed of switching operation induced section (SOIS), extinction ratio adjusted section (ERAS), and extinction ratio enhanced section (ERES). In this VDCSs, switching operation is achieved by changing the refractive index of one core in SOIS. The improvement of extinction ratios larger than 30㏈ for both cross and bar states is achieved by controlling the asymmetry of refractive indices between both cores in ERES. After propagating through ERAS with symmetry in the structure, different extinction ratios between cross and bar states at the end of SOIS are changed to the same value. For this reason, the optimum asymmetry of the refractive indices of cores to have the maximum extinction ratios and the lengths of ERES are the same for cross and bar states. Design guidelines to achieve high extinction ratios with large tolerances are presented.

Synthesis and Photoluminescence Properties of CaWO4:Eu3+ Phosphors (CaWO4:Eu3+ 형광체의 합성과 발광 특성)

  • Cho, Shin-Ho;Cho, Seon-Woog
    • Korean Journal of Materials Research
    • /
    • v.22 no.5
    • /
    • pp.215-219
    • /
    • 2012
  • Red phosphors $Ca_{1-1.5x}WO_4:{Eu_x}^{3+}$ were synthesized with different concentrations of $Eu^{3+}$ ions by using a solid-state reaction method. The crystal structure of the red phosphors was found to be a tetragonal system. X-ray diffraction (XRD) results showed the (112) main diffraction peak centered at $2{\theta}=28.71^{\circ}$, and the size of crystalline particles exhibited an overall decreasing tendency according to the concentration of $Eu^{3+}$ ions. The excitation spectra of all the phosphors were composed of a broad band centered at 275 nm in the range of 230-310 nm due to $O^{2-}{\rightarrow}W^{6+}$ and a narrow band having a peak at 307 nm caused by $O^{2-}{\rightarrow}Eu^{3+}$. Also, the excitation spectrum presents several strong lines in the range of 305-420 nm, which are assigned to the 4f-4f transitions of the $Eu^{3+}$ ion. In the case of the emission spectrum, all the phosphor powders, irrespective of $Eu^{3+}$ ion concentration, indicated an orange emission peak at 594 nm and a strong red emission spectrum centered at 615 nm, with two weak lines at 648 and 700 nm. The highest red emission intensity occurred at x = 0.10 mol of Eu3+ ion concentration with an asymmetry ratio of 12.5. Especially, the presence of $Eu^{3+}$ in the $Ca_{1-1.5x}WO_4:{Eu_x}^{3+}$ shows very effective use of excitation energy in the range of 305-420 nm, and finally yields a strong emission of red light.

VERTICAL STRUCTURE OF NGC 4631

  • Ann, Hong-Bae;Seo, Mi-Ra;Baek, Su-Ja
    • Journal of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.23-32
    • /
    • 2011
  • We present a deep CCD imaging in B and V bands which allows us to analyze the vertical structure of NGC 4631. We derive the scale heights of the thin and thick disks at a variety of positions along the major axis of the disk. The scale heights of the thin disk are nearly constant while those of the thick disk tend to increase with increasing galactocentric distance. The mean scale heights of the thin disk derived from B and V images are similar to each other (~ 450 pc). Instead, those of the thick disk show a strong east-west asymmetry which is caused by the diffuse stellar emission that is most prominent in the north west regions above the disk plane. The ratio of scale heights ($z_{thick}/z_{thin}$) is about 2.5 in the east side of the disk. However, this ratio is greater than 4 for the thick disk above the disk plane in the west side of the galaxy.

Bluff body asymmetric flow phenomenon - real effect or solver artefact?

  • Prevezer, Tanya;Holding, Jeremy;Gaylard, Adrian;Palin, Robert
    • Wind and Structures
    • /
    • v.5 no.2_3_4
    • /
    • pp.359-368
    • /
    • 2002
  • This paper describes a CFD investigation into the flow over the cab of a bluff-fronted lorry. Several different simulations were undertaken, using the commercial codes: CFX, Fluent and PowerFLOW. Using the $k-{\varepsilon}$ turbulence model, the flow over the cab was symmetric, however, using more accurate turbulence models such as the RNG $k-{\varepsilon}$ model or the Reynolds Stress Model, the flow was asymmetric. The paper discusses whether this phenomenon is a real effect or whether it is a solver artefact and the study is supported by experimental evidence. The findings are preliminary, but suggest that it has a physical origin and that it may be aspect ratio-dependent.

The Effect of the Y-jet Nozzle Exit Orifice Shape on Asymmetric Spray (Y-jet 노즐의 출구오리피스 형상이 비대칭 분무에 미치는 영향)

  • Baik, Gwang Yeol;Hong, Jung Goo
    • Journal of ILASS-Korea
    • /
    • v.26 no.1
    • /
    • pp.33-39
    • /
    • 2021
  • Y-jet nozzle has a wide fuel flow rate range and turn-down ratio, thus, it is used in industrial boilers, furnace and agricultural atomizer. However, it has asymmetrical spray characteristics due to the nozzle design factors. Therefore, in this study, asymmetric spraying characteristics of the elliptical Y-jet nozzle was studied by using the lab-scale spray apparatus. As a result, the elliptical Y-jet nozzle had lower gas mass flow rate than circular Y-jet nozzle at same gas pressure, because of bigger shear stress due to the wider inner surface at the elliptical Y-jet nozzle. Larger SMD was measured on the elliptical Y-jet nozzle than the circular Y-jet nozzle. When SMD was measured in the X_Axis direction at the same gas mass flow rate, the elliptical Y-jet nozzle with an aspect ratio of 2:1 showed greater asymmetry than the others.

Dynamic Characteristics of Composite Thin-Walled Beams with a Chord wise Asymmetric Cross-Section: I. Single-Cell (시위 방향 비대칭 단면의 복합재료 박벽보의 동특성 연구: I. 단일-셀)

  • Kim, Keun-Taek
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.6
    • /
    • pp.41-49
    • /
    • 2018
  • In this study, the theoretical dynamic characteristics of a thin-walled composite beam with a single-cell of chordwise asymmetric cross-section was studied. Mathematical modeling was done by considering the transverse shear effects, the warping restraint effects, the constant taper ratio in the longitudinal direction of the beam, and the geometrical cross-section ratio. The mass coefficients, stiffness coefficients, and Eigen frequencies of the selected section were investigated. In particular, the effects of the taper ratio and cross-section ratio of the model on the Eigen frequencies were analyzed and compared when the asymmetry of the section was considered and the warping function was not corrected.

Comparative Evaluation of the Lateral Ventricles with Computed Tomography in Yorkshire Terrier, Maltese, and Shih-Tzu Dogs (시쮸, 말티즈, 요크셔테리어 견에서 컴퓨터단층촬영을 이용한 뇌실 크기의 비교 평가)

  • Choi, Ho-Jung;Lee, Ki-Ja;Ahn, Se-Joon;Kwon, Young-Hang;Jung, Ki-Young;Lee, Hee-Chun;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.1
    • /
    • pp.7-12
    • /
    • 2011
  • This study was performed to evaluate the size and asymmetry of the lateral ventricles in CT images of three different small breed dogs. CT examinations were performed on thirty Yorkshire terriers, malteses, and shihtzu dogs, respectively. The size and asymmetry of their lateral ventricles were evaluated at three different levels of brain, and dogs were categorized on the basis of the percentage of their ventricular height (Vh) to brain height (Bh). Degree of asymmetry was also categorized based on the rVh (ratio of right and left ventricular heights) as normal (rVh < 1.5), mild (1.5 < rVh < 2.0), or severe (2.0 < rVh). Clinically insignificant ventricular dilation was common in these breed dogs. However, severe asymmetry was not presented in clinically normal dogs. We suggested 11 mm as an upper limit of ventricular size in normal small breed dogs.

An Experimental Study on Blasting Collapse Behavior of Asymmetry Structure with High Aspect Ratio (고종횡비 비대칭 구조물의 발파붕괴 거동에 관한 연구)

  • Song, Young-Suk;Jung, Min-Su;Jung, Dong-Wol;Hur, Won-Ho
    • Explosives and Blasting
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • In blasting demolition, a method would be chosen among many depends on shape and system of a structure and its surround. To demolish using explosives a structure, which is asymmetric and with high aspect ratio, pre-weakening, explosive locations, detonating delay, and surround conditions are needed to be considered in front to design blasting demolition plan. In this study, to over turn asymmetric and high aspect ratio structure in safe, a simulation using a software named Extreme Loadings for Structures, ELS, had performed. In results, it is achieved optimized pre-weakening shapes and locations, which prevent kick back motion of the structure when it collapse, by analyzing moment distribution caused by pre-weakening. And of structural collapse and by minimizing asymmetric structure's torsional moment. Also, after the demolition, simulation results are also compared with actual collapse behavior. In results, it is confirmed the accuracy of collapse behaviour simulation results, and in blasting demolition, kick back motion can be controled by adjusting pre-weakening shape and location, and the torsional moment of an asymmetric structure also can be solved by optimizing detonation locations and its time intervals.

A Study on the Relationship between the Disclosure of the Company's Internal Control System and the Agency Costs -Focused on SSE Listed Companies (기업 내부통제시스템 도입과 기업 대리 비용과의 관계연구 - SSE 상장기업을 중심으로)

  • Kim, Dong-Il;Choi, Seung-Il
    • Journal of Digital Convergence
    • /
    • v.18 no.8
    • /
    • pp.111-118
    • /
    • 2020
  • This study conducted an empirical analysis of SSE-listed companies to verify the effects of evaluation and disclosure of internal control systems on the agency costs management and controlling shareholders. Agency costs can affect the valuation of accounting information as asymmetry of information in the relationship between a company and its stakeholders, or induce financial costs as an adverse selection. If the firm's agency costs are reasonable, the valuation of the company can also move in a relatively positive direction. In this study, the evaluation information of the internal control system was analyzed through sales management ratio and equity ratio as substitute variables to analyze the relationship between management and agent costs of the controlling shareholders. In addition, independent control ratio, capital balance ratio, and company scale were used as control variables, as a result of the analysis, the evaluation information of internal control was found to be related to the agency costs of managers and governance structure. This study can be conducted to positive factors in evaluating the reliability and corporate value of accounting information according to the evaluation of internal control of SSE-listed companies and helps to understand the financial reporting environment.